Omega | UWBT Series | Owner Manual | Omega UWBT Series Owner Manual

Omega UWBT Series Owner Manual
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
5
6
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects
in materials and workmanship for a period of 13 months from date
of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover
handling and shipping time. This ensures that OMEGA’s customers
receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized
Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it
will be repaired or replaced at no charge. OMEGA’s WARRANTY does
not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation
outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having
been tampered with or shows evidence of having been damaged as a
result of excessive corrosion; or current, heat, moisture or vibration;
improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear
is not warranted, include but are not limited to contact points, fuses,
and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use if its products in accordance
with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by
the company will be as specified and free of defects. OMEGA
MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF
ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT
THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING
ANY WARRANTY OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set
forth herein are exclusive, and the total liability of OMEGA
with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise,
shall not exceed the purchase price of the component upon
which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used,
nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC),
used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with
any nuclear installation or activity, medical application, used on humans,
or misused in any way, OMEGA assumes no responsibility as set forth
in our basic WARRANTY/DISCLAIMER language, and, additionally,
purchaser will indemnify OMEGA and hold OMEGA harmless from any
liability or damage whatsoever arising out of the use of the Product(s)
in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA
Customer Service Department.
BEFORE RETURNING ANY
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER
SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the
outside of the return package and on any correspondence.
FOR WARRANTY RETURNS,
please have the following
information available BEFORE
contacting OMEGA:
1. Purchase Order number
under which the product
was PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or
specific problems relative
to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair
charges. Have the following
information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover
the COST of the repair or
calibration,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes,
whenever an improvement is possible. This affords our customers
the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved.
This document may not be copied, photocopied, reproduced,
translated, or reduced to any electronic medium or machine-readable
form, in whole or in part, without the prior written consent of OMEGA
ENGINEERING, INC.
MQS5417/0717
Hardware
Transmitter Diagram
RED/YELLOW LED
POWER SWITCH
Wiring Diagrams
UWBT-TC-M12 Wiring
The TC models use standard pin connections, as shown
below:
I
O
–
TC#1
–
+
TC#1
+
TC#2
(OPTIONAL)
TC#2
(OPTIONAL)
MINI-B USB
Rear Label
The rear label is marked with international safety and
hazard symbols in accordinance with IEC standards.
UWBT-RTD-M12 Wiring
PIN #4
PIN #1
IEC SYMBOL:
EU’s WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT
COMPLIANCE
IEC SYMBOL:
CAUTION, REFER TO
ACCOMPANYING
DOCUMENTATION
NOTE:
It is recommended that you recharge your transmitter when
you reach 20% battery level or lower.
Transmitter LED Indication Table
(The red & yellow colors
come from one LED)
Red LED Yellow LED
State
State
Green
LED
Transmitter Status
Blinking
-
Blinking
Sensor Out of Range
Blinking
-
Blinking
Sensor Open
Red LED blinks twice every 2 seconds.
Blinking
-
-
Low or High Alarm
Red LED blinks every 5 seconds.
Blinking
-
-
Low Battery
Green LED blinks every second.
-
-
Blinking
Downloading data from probe
Green LED blinks 3 times every 3 seconds.
-
-
Blinking
Device Paired/ Data being sent
Green LED blinks twice every 3 seconds.
-
-
Blinking
Internal logging on
Green LED blinks once every 3 seconds.
-
-
Blinking
The transmitter is on and connected
to a sensor, but is not paired
with a smart device.
Blinking
-
-
Device unpaired
Red LED blinks every second for 2
minutes, then stops.
Blinking
-
-
Transmission enabled (searching
to pair)
Red & Green LEDs blink twice together,
then go off.
Blinking
-
Blinking
-
On
-
Battery Charging
Battery Fully Charged
Yellow LED blinks every second.
-
Blinking
-
Green & Red LEDs turn on for ½ second,
then go off.
On
-
On
Red LED turns on for ½ of a second, then
goes off.
On
-
-
-
-
Blinking
Blinking
Blinking
-
Green LED blinks 3 times, then the
transmitter turns off.
Yellow & Red LEDs blink alternatively.
PIN #2
PIN #3
diagram below:
UWBT-RTD-TB Terminal Block Wiring
The UWBT-RTD-TB comes with a 3-wire terminal
block. The terminal block can be unplugged from the
handle, allowing for easier handling of the wires. See
below:
ANSI & IEC: RED
Handheld Bluetooth® Wireless Temperature,
Humidity and pH Transmitter Series
UWBT-TC
UWBT-RTD
UWBT-RH
UWBT-PH
ANSI: BLACK (IEC: WHITE)
Red & Green LEDs blink alternatively.
Yellow LED is on continuously.
UWBT SERIES
ANSI: BLACK (IEC: WHITE)
Red & Green LEDs blink alternatively.
Red LED blinks every second for 2
minutes, then unit switches off.
PIN #1
PIN #2
PIN #3
R
RoHS 2 Compliant
GREEN LED
PAIR BUTTON
LED Action
For complete product manual:
www.omega.com/manuals/manualpdf/M5417.pdf
Factory Settings have been
successfully re-installed on the
transmitter.
3-WIRE RTD
ANSI & IEC: RED
ANSI: BLACK (IEC: WHITE)
2-WIRE RTD
Additional Information
Please visit the Omega website and download the
full-length UWBT manual for more information on the
UWBT transmitter and its applications.
www.omega.com/uwbt
®
omega.com info@omega.com
Transmitter has been powered up
successfully
Transmitter has failed to power
up successfully
Transmitter has
successfully poweredoff
Transmitter internal memory is full.
The Bluetooth® word mark is a registered trademark owned by Bluetooth SIG, Inc. and
any use of such marks by OMEGA is under license.
iOS is a trademark or registered trademark of Cisco in the U.S. and other countries and is
used by Apple under license.
Android is a trademark of Google, Inc.
Other trademarks and trade names are those of their respective owners.
U.S.A.
Headquarters:
Servicing North America:
Omega Engineering, Inc.
Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only)
Tel: (203) 359-1660
Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
START HERE
2
3
Software Notes For (iOS & Android™)
NOTE:
Having the transmitter paired with the UWBT app does
not mean that transmission is active. You must either be
in the “Display” or “Settings” screens, or be logging
data, for the Bluetooth® wireless transmission to be
active. Otherwise, the transmitter will unpair after 2
minutes.
NOTE:
Pairing Within the UWBT App:
1. M
ake sure your UWBT transmitter is switched on
and that the Bluetooth wireless communication to
the smart device has already been established. See
“Pairing within smart device Settings menu (iOS
operating system only)” in the previous section for
details on this process.
2. Open the UWBT app.
3. I n the UWBT app, go to the ‘Transmitter Pairing’
settings.
Software For (Android)
Initial Pairing Instructions
In order to start communicating with the UWBT
transmitter, you need to pair it with your smart device
via Bluetooth wireless communication.
Pairing within the UWBT App:
1. Make sure your UWBT transmitter is switched on.
2. Open the UWBT app.
3. In the UWBT app, go to the ‘Transmitter Pairing’
settings
4. Hold down the transmitter’s ‘Pair’ button for 2
seconds – this will put the sensor in discovery mode.
4. I n the ‘Discovered Devices’ list, select the transmitter
you would like to pair with.
5. In the ‘Discovered Devices’ list, select the transmitter
you would like to pair with.
6. Click on the ‘Pair’ button.
7. The smart device will create a prompt asking if you
would like to pair with the specific transmitter. Click
‘Yes’. (Please note that this prompt only pops up
during your first time pairing with a transmitter.)
You cannot pair the same transmitter with multiple
smartphones or tablets. In order to view a transmitter’s
information on a different tablet, you will need to unpair
the transmitter from the UWBT app.
Software For (iOS)
Initial Pairing Instructions
In order to start communicating with the UWBT
transmitter, you need to pair it with your smart
device via Bluetooth wireless communication. For
devices that work with the iOS operating system,
you must pair within the iOS settings before
pairing within the UWBT app. Devices for Android
only require pairing from within the UWBT app.
Pairing within smart device Settings menu (iOS
only):
1. Switch on your UWBT transmitter.
2. Hold down the transmitter’s ‘Pair’ button for 2
seconds – this will put the sensor in discovery
mode.
3. Go to the Settings page of your smart device
4. Select the Bluetooth wireless section
5. Make sure your Bluetooth wireless functionality
is turned on – the Bluetooth wireless slider
should be showing a green background.
6. Tap the device to be paired via Bluetooth wireless
communication.
ARTWORK/PRODUCT ART/
DWGS/START HERE ARROW
4
Software (PC)
Installing the PC Application
To install the UWBT PC application on your
computer follow these steps:
1. Download the latest UWBT PC application
release from our website at ftp://ftp.omega.
com/public/DASGroup/products/
2. After download is completed, open the
directory where the download was saved
3. Click and run the UWBT PC app executable
file (.exe). The application and its drivers will be
installed automatically.
4. After application is fully installed, a shortcut is
created on your computer desktop and “UWBT
Libusb” directory is created in the C: drive of
your PC. This directory contains the drivers for
all UWBT transmitter models.
Discover Transmitter:
Clicking the “Discover Transmitter” button
searches for UWBT transmitters connected to
USB ports of the PC. The maximum number of
UWBT transmitters that can be discovered is four.
After being discovered, only one UWBT
transmitter can be connected with the PC app at a
time.
• You can connect to any of the discovered
transmitters by clicking the “Select” button next
to the transmitter’s name.
• You can also switch the transmitter you are
connected to by clicking on the “Select” button
next to the new transmitter of your choice. The
application will automatically disconnect from
the previous transmitter, and connect to the new
one.
5. Click on the ‘Pair’ button.
6. You are ready to display and log data!
NOTE:
8. You are ready to display and log data!
The “Discover Transmitter” button’s name changes
to “Disconnect Transmitter” after a UWBT device is
connected.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising