Gefen | EXT-ADA-LAN-TX | Gefen EXT-ADA-LAN-TX Manual | Gefen EXT-ADA-LAN-RX Digital and Analog Audio over IP - Receiver Package Manual

Gefen EXT-ADA-LAN-RX Digital and Analog Audio over IP - Receiver Package Manual
Gen 2.0
Digital & Analog Audio
over IP
EXT-ADA-LAN-TX
EXT-ADA-LAN-RX
User Manual
Version A2
Important Safety Instructions
1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this product near water.
6.
Clean only with a dry cloth.
7.
Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8.
Do not install or place this product near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two blades
and a third grounding prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11.
Only use attachments/accessories specified by the manufacturer.
12. To reduce the risk of electric shock and/or damage to this product, never handle or touch
this unit or power cord if your hands are wet or damp. Do not expose this
product to rain or moisture.
13.
Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped.
15.
Batteries that may be included with this product and/or accessories should never be
exposed to open flame or excessive heat. Always dispose of used batteries
according to the instructions.
2
Warranty Information
For the latest warranty coverage information, refer to the Warranty and Return Policy under
the Connect section of the Gefen website at http://www.gefen.com/connect/warranty-andreturn-policy
3
Contact Us
Technical Support
1-707-283-5900
1-800-472-5555
8:00 AM to 5:00 PM Monday - Friday, Pacific Time
Email
support@gefen.com
Web
http://www.gefen.com
Mailing Address
Gefen
Nortek Security & Control, LLC
c/o Customer Service
1800 S McDowell Blvd
Petaluma, CA 94954 USA
© 2018 Nortek Security & Control, LLC. All Rights Reserved.
All trademarks are the property of their respective owners.
Gefen and Nortek Security & Control, LLC reserve the right to make changes in the hardware,
packaging, and any accompanying documentation without prior notice.
4
Operating Notes
Important
•
When connecting through a Local Area Network, a managed gigabit switch is required.
Jumbo Frame Support (8k or greater) and IGMP Snooping must be enabled.
•
A dedicated LAN is not required but highly recommended.
•
In a Multi-Format system, when using HDCP-encrypted content, only HDMI &
DisplayPort™ inputs & outputs can accept or display content.
•
We recommend that Sender and Receiver are first connected directly and functionality/
performance is fully verified before integrating them into a Local Area Network.
•
Always make sure that all units within a system are running the latest firmware.
•
This product has been specifically designed for use with the Gefen Syner-G™ Software
Suite, available for download at www.gefen.com. The Gefen Syner-G™ Discovery and
Show-Me features simplify initial IP configuration
•
Gefen highly recommends the Gefen EXT-CU-LAN Matrix Controller for setting up and
controlling the operation of an AV-over-IP network using these products. Alternatively,
the Syner-G™ software can be used for IP configuration and firmware updates.
•
Shielded CAT-5e (or better) cables used between the Sender and the Receiver unit or
between each unit and the IP switch, should not exceed 330 feet (100 meters).
•
By default, all Sender and Receiver units are set to channel 0.
•
If terminating network cables in the field, please adhere to the TIA/EIA568B
specification. See the Network Cable Diagram (page 123) for details.
This product uses UL-Listed power supplies
5
Operating Notes
Licensing
This product uses software that is subject to open source licenses, including one or more of
the General Public License Version 2 and Version 2.1, Lesser General Public License Version 2.1
and Version 3, BSD, and BSD-style licenses. Distribution and use of this product is subject
to the license terms and limitations of liability provided in those licenses. Specific license
terms and Copyright Notifications are provided in the source code. For three years from
date of activation of this product, any party may request, and we will supply, for software
covered by an applicable license (e.g. GPL or LGPL), a complete machine-readable copy of the
corresponding open source code on a medium customarily used for software interchange.
The following software and libraries are included with this product and subject to their
respective open source licenses:
•
•
jQuery
Linux
6
Features
Features
•
Extends digital and analog audio, RS-232, and IR, using a Gigabit Local Area Network
•
Independent audio, RS-232, and IR routing**
•
Supports 2 channels of PCM (Analog L/R and Coaxial/Optical Digital outputs) and up to 5.1 channels
(Coaxial/Optical Digital outputs) of Bitsream audio when connected to HDMI sources on HDMI
capable Gefen AV over IP products.
•
Backward-compatible with first generation Gefen AV over IP products
•
Analog L/R, Coaxial Digital, and Optical Digital Inputs and Outputs
•
MFU (Mass-Firmware-Update), quick and automated configuration, and enhanced control
capabilities and system security when used with the Gefen EXT-CU-LAN Matrix Controller
•
Enhanced API for added functionality with third-party control systems
•
Built-in web interface, Telnet, and UDP
•
Compatible with the Gefen Keyboard Switching Controller software, available for download at www.
gefen.com
•
Supports 39,900 Senders and a combination of over 65,000 Sender and Receiver units, depending
on the network bandwidth and number of ports on your network switch
•
802.3af standard Power-over-Ethernet allows the new Sender and Receiver units to be powered
through a standard PoE-enabled IP network switch, without the need for external power supplies
•
Two-port Gigabit Ethernet switch built into the Receiver unit
•
Field-updatable firmware via EXT-CU-LAN controller or the built-in web server interface
•
Locking power supply connectors
•
Low-profile, half-rack width Sender and Receiver enclosures are rack-mountable using EXT-RACK1U-GRY
•
Sender and Receiver can also be surface-mounted using the included L-brackets
•
Low profile Receiver enclosure features an IR Extender port and can be hidden away
* Features and specifications are subject to change without notice.
7
Packing List
Packing List - Sender unit
The following items are included in the Sender Unit package. If any of these items are not
present in the box when you first open it, please contact Gefen Technical Support as soon as
possible.
(1)
(1)
(1)
(1)
(4)
(2)
(4)
(2)
(1)
Sender unit (EXT-ADA-LAN-TX)
5V 2.6A Power Supply
3.5mm-to-DB-9 Adaptor, M-F (ADA-MP-2-DB9-MF-AB)
IR Emitter (EXT-IREMIT)
Self-Adhesive Rubber Feet
L-Shaped Mounting Brackets
Machine screws for L-Shaped Mounting Brackets
Machine screws for EXT-RACK-1U-GRY (sold separately)
Quick-Start Guide
Packing List - Receiver unit
The following items are included in the Receiver Unit package. If any of these items are not
present in the box when you first open it, please contact Gefen Technical Support as soon as
possible.
(1)
(1)
(1)
(1)
(4)
(2)
(4)
(2)
(1)
Receiver unit (EXT-ADA-LAN-RX)
5V 2.6A Power Supply
3.5mm-to-DB-9 Adaptor, M-M (ADA-MP-2-DB9-MM-AB)
IR Extender Module (EXT-RMT-EXTIRN)
Self-Adhesive Rubber Feet
L-Shaped Mounting Brackets
Machine screws for L-Shaped Mounting Brackets
Machine screws for EXT-RACK-1U-GRY (sold separately)
Quick-Start Guide
8
Table of Contents
Introduction.....................................................................................................................11
Sender Unit..............................................................................................................................11
Receiver Unit.......................................................................................................................... 13
Installation..................................................................................................................... 16
Local Area Network (LAN) Connection................................................................................. 16
Using a Direct Connection.................................................................................................... 20
Supplementary Connections.................................................................................................22
Sample Wiring Diagram........................................................................................................23
LED Status.......................................................................................................................24
Link2.
Power2.
42
42
Setting the Audio Channel............................................................................................ 25
Setting the Channel using the Web Interface......................................................................25
Setting the Channel using the Front Panel...........................................................................26
Muting Audio..................................................................................................................28
Unicast & Multicast Modes...........................................................................................30
Configuring Unicast Mode.....................................................................................................30
Switching between Sender units in Unicast mode...............................................................32
Configuring Multicast Mode................................................................................................. 35
Discovery Mode.............................................................................................................. 37
Gefen Syner-G Discovery....................................................................................................... 37
Finding Your Device...............................................................................................................38
RS-232 Control................................................................................................................40
RS-232 under Unicast Mode..................................................................................................42
RS-232 under Multicast Mode...............................................................................................42
Audio Connections.........................................................................................................43
Sender Unit.............................................................................................................................43
Receiver Unit..........................................................................................................................43
Audio Port Priority.................................................................................................................44
Changing the Password.................................................................................................46
Utilities............................................................................................................................47
Reset using the Web Interface..............................................................................................47
Reboot using the Web Interface...........................................................................................49
Reboot using the Front Panel................................................................................................50
9
Table of Contents
Telnet Access....................................................................................................................51
Commands...................................................................................................................... 52
Discovery Service....................................................................................................................52
Help5.
25
Network5.
25
Routing5.
35
RX Specific..............................................................................................................................54
Serial5.
55
System5.
55
TX Specific.............................................................................................................................. 55
Web Interface......................................................................................................................... 55
Network Cable Diagram...............................................................................................123
Rack Tray Installation.................................................................................................. 124
Specifications*...............................................................................................................125
10
Introduction
EXT-ADA-LAN-TX
EXT-ADA-LAN-TX
Sender Unit
2
1
3
4
Reset
Prog
5
On
Power
Link
Power
6
Link
Reset
7
Off
Prog Sel
On
Prog
Off
Prog Sel
8
9
10
11
12
13
EXT-ADA-LAN-TX
EXT-ADA-LAN-TX
5V DC
LAN (PoE)
RS-232
IR In/Ext
IR Out
Line In
Opt In
Coax In
5V DC
LAN (PoE)
RS-232
IR In/Ext
IR Out
Line In
Opt In
Coax In
ID
Name
Description
1
Power
This LED indicator glows solid blue when the
unit is powered.
2
Link
This LED glows solid green when a link
is established between the Sender and
Receiver.
3
Reset
Press this button, using the end of a paper clip
or other pointed object, to perform a soft reset.
4
Prog
This button is used for device recovery
5
Prog Sel
For normal operation, this switch should be in
the Off position. Setting this switch to the On
position, places the unit in the ready-state for
firmware recovery or debug operations.
Digital and Analog
Audio
- Sender
operations,
in theover
event ofIP
a firmware
update
or other
failure. over IP - Sender
Digital and Analog
Audio
11
Introduction
ID
Name
Description
6
5V DC
This power receptacle is used to connect the
included 5V DC power supply. An external
power supply is not required when connecting
to a PoE-enabled switch using the LAN (PoE)
port.
7
LAN (PoE)
Connect a CAT-5e or better cable up to 330
feet/100 meters, from this port to a PoEcapable network switch. If a PoE switch is
not available or the Sender and Receiver are
connected directly, then the included 5V DC
power supply must be connected to the Sender
unit.
8
RS-232
Using the included 3.5mm-to-Female-DB-9
adapator, connect an DB-9 cable from this port
to a RS-232 automation control unit. See RS232 Control (page 40) for more information.
9
IR In/Ext
Connect an IR Extender (Gefen part no.
EXT-RMT-EXTIRN) to this port. Alternatively,
connect a 3.5mm mini-stereo connector
from this port to the electrical IR output of
an automation control system.
10
IR Out
Connect an IR Emitter (Gefen part no. EXTIREMIT) from this port to the IR sensor of the
device to be controlled.
11
Line In***
Connect a 3.5mm mini-stereo cable from this
port to the analog audio source.
12
Opt In***
Connect a digital audio cable with TOSLINK®
connectors from this port to the digital audio
output of a source.
13
Coax In***
Connect a digital audio cable with RCA
connectors from this port to the digital audio
output of a source.
*** Please note that when Line In on Sender is plugged in, it takes priority over the two digital inputs. If Line In is
not connected, the two digital ports have the same priority. First one connected will be active. If both digital
ports are connected and then the unit is powered on, Opt In will be active. To avoid inconsistent and/or
confusing user experience, we recommend that only one type of input is connected at a time.
12
EXT-ADA-LAN-RX
EXT-ADA-LAN-RX
Introduction
Receiver Unit
2
1
3
4
5
6
On
Off
Power
Link
Reset
Prog
Prog Sel
On
Off
Power
Link
Reset
Prog
Prog Sel
7
8
9
10
11
–
CH
+
–
CH
+
12
13
14
15
EXT-ADA-LAN-RX
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
ID
Name
Description
1
Power
This LED indicator glows solid blue when the
unit is powered.
2
Link
This LED glows solid green when a link
is established between the Sender and
Receiver.
3
Reset
Press this button, using the end of a paper clip
or other pointed object, to perform a soft reset.
4
Prog
This button is used for device recovery
operations, in the event of a firmware update
or other failure.
5
Digital and Analog Audio over IP - Receiver
Digital and Analog Audio over IP - Receiver
Prog Sel
For normal operation, this switch should be in
the Off position. Setting this switch to the On
position, places the unit in the ready-state for
firmware recovery or debug operations.
13
Introduction
ID
Name
Description
6
CH -/+
Press the - / + buttons button to decrement /
increment, respectively, the current channel
number. See Setting the Audio Channel (page
25) for more information.
7
Coax Out****
Connect a digital audio cable with RCA
connectors from this port to the digital audio
input of an AV receiver or amplifier.
8
Opt Out****
Connect a digital audio cable with a TOSLINK®
connectors from this port to the digital audio
input of an AV receiver or amplifier.
9
Line Out****
Connect a 3.5mm mini-stereo cable from this
port to an amplifier or other audio output
device.
10
RS-232
Using the included 3.5mm-to-Male-DB-9
adapator, connect a DB-9 cable from the
Receiver to the display or another device
to be controlled. See RS-232 Control (page
40) for more information.
11
IR In/Ext
Connect an IR Extender (Gefen part no.
EXT-RMT-EXTIRN) to this port. Alternatively,
connect a 3.5mm mini-stereo connector
from this port to the electrical IR output of
an automation control system.
12
IR Out
Connect an IR Emitter (Gefen part no. EXTIREMIT) from this port to the IR sensor of the
device to be controlled.
13
LAN 1
Use this port to connect IP-enabled devices,
or to daisy-chain additional Receiver units
(only when a single source is used, otherwise
bandwidth may be compromised). CAT-5e or
better cables up to 330 feet/100 meters. This
port is NOT PoE -capable.
**** All three audio outputs of the Receiver can be used simultaneously, but if the signal
format is Bitstream, the analog output will not work.
14
Introduction
ID
Name
Description
14
LAN 2 (PoE)
Connect a CAT-5e or better cable up to 330
feet/100 meters, from this port to a PoEcapable network switch. If a PoE switch is
not available or the Sender and Receiver are
connected directly, then the included 5V
DC power supply must be connected to the
Receiver unit.
15
5V DC
This power receptacle can be used to connect
the included 5V DC power supply. An external
power supply is not required when connecting
to a PoE-enabled switch using the LAN 2 (PoE)
port.
15
Installation
The Gen 2.0 AV and KVM over IP Sender and Receiver units can be connected directly or
through a Local Area Network (LAN). Both installations will be covered.
Local Area Network (LAN) Connection
When connecting the Sender and Receiver units to a Local Area Network (LAN), DHCP, static,
or APIPA (Automatic Private IP Addressing) IP modes can be used. DHCP mode will use the
EXT-ADA-LAN-TX
DHCP server to automatically assign an IP address for each Sender and Receiver unit that
is connected to the network. Static IP mode will allow the IP address for each Sender and
Receiver unit to be configured manually. Contact your network administrator if necessary.
APIAP mode assigns a class-B IP address, in the 169.254.x.x range, to the Sender and
Receiver units, if a DHCP server is not available.
1.
Connect a CAT-5e (or better) cable between
On
Off the LAN (PoE) port on the Sender unit and a
Power Link
Reset
Prog
Prog Sel
Gigabit PoE-enabled
IP switch.
2.
Connect LAN 2 (PoE) on the Receiver unit to the same network switch. Each cable run can
be up to 330 feet (100 meters).
Sender unit
EXT-ADA-LAN-TX
5V DC
LAN (PoE)
RS-232
IR In/Ext
IR Out
Line In
Opt In
Coax In
to PoE-compatible switch
3.
If NOT USING A PoE-compliant switch, then connect the included 5V DC power supplies
to the Sender and Receiver units.
Important
If the IP switch is PoE-compliant and the Sender and Receiver are connected
through their PoE ports, external power supplies will not be required. However,
additional Receivers or other devices connected to the LAN 1 port of a Receiver will
require an external power supply.
Digital and Analog Audio over IP - Sender
16
Installation
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
Receiver unit
Connect to LAN
4.
Launch the Gefen Syner-G™ app to discover the IP address of the Sender/Receiver unit.
See the Gefen Syner-G™ User Manual for more information.
5.
Click the desired unit from the list. The currently selected unit will be highlighted in red.
6.
Use the fields in the Device Settings section to change the IP settings, as necessary.
Digital and Analog Audio over IP - Receiver
Device Settings
Selected Unit
17
Installation
7.
Once all IP settings have been adjusted, click the Apply button.
8.
Click the Reboot button to apply changes.
9.
Repeat steps 4 - 8 for each Sender and Receiver unit as necessary.
10. Open your Web browser and enter the IP address of the desired Sender or Receiver unit
in the address bar.
11.
The Login screen will be displayed.
12. In order to change network settings, you must login as “Administrator”. Select the
“Administrator” username from the drop-down list.
13.
Type the password in the Password field. The default password for “Administrator”
is admin. The password is case-sensitive and will be masked as it is entered.
Note
Passwords and operating features can be changed when logged in as Administrator.
The User option has limited access. To change password credentials, see Changing
the Password (page 60) for more information.
18
Installation
14. Click the Login button.
15.
The Network will automatically be selected. The current IP Mode will be highlighted
within the IP Setup window group.
16. Click the desired IP Mode button.
•
If Static mode is selected, then enter the IP Address, Subnet Mask, and Default Gateway.
Contact your system administrator if necessary.
•
If DHCP mode is selected, then the IP address, subnet mask, and default gateway will be
specified by the DHCP server.
17.
Click the Apply button to save the changes. This operation will require a reboot.
18. Click the Reboot button near the bottom of the page.
19. Repeat steps 12 - 21 for each Sender and Receiver to be configured.
After the desired IP settings have been applied, set the audio channel for each Sender
unit. See Setting the Audio Channel (page 25) for more information.
Important
The use of a Managed Gigabit switch with “Jumbo Frame” and “IGMP Snooping”
capability is required when connecting the Gefen AV over IP products to a network.
The switch should be set to greater than 8K and IGMP Snooping must be enabled.
19
Installation
Using a Direct Connection
By default, all Senders and Receivers are shipped in APIPA (Auto) mode. This network mode
is used for directly connecting Sender and Receiver units to one another. APIAP mode assigns
a class-B IP address, in the 169.254.x.x range, to the Sender and Receiver units, if a
DHCP server is not available. When using a direct connection, each unit can remain in Auto
mode and can be assigned a static or DHCP IP address using the Gefen Syner-G sofrware, or
manually
through the built-in web interface.
EXT-ADA-LAN-TX
1.
Connect an HDMI cable to connect the source to the HDMI In port on the Sender unit.
2.
Connect an HDMI cable from the display to the HDMI Out port on the Receiver unit.
3.
On the
OffLAN (PoE) port on the Sender unit to the
Connect a CAT-5e (or better) cable from
Power Link
Reset
Prog Sel
LAN 1 or LAN
2 (PoE) port
onProgthe Receiver
unit. The other LAN port can then be used for
connecting (daisy-chaining) an additional Receiver unit. Each cable run can be up to 330
feet (100 meters). Please note that PoE is not active in direct connection. The Sender and
all connected Receivers will need to be powered using their external power supplies.
EXT-ADA-LAN-RX
–
On
Power
5V DC
Link
Reset
Prog
+
EXT-ADA-LAN-TX
Prog Sel
RS-232
LAN (PoE)
CH
Off
IR In/Ext
IR Out
Line In
Opt In
Coax In
Sender unit
EXT-ADA-LAN-RX
Coax Out
Receiver unit
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
to IP-enabled devices
4.
Connect the included 5V DC locking power supplies to both the Sender unit and Receiver
unit. Do not overtighten the locking connectors. Plug the power supplies to available
electrical outlets.
5.
See Local Area Network (LAN) Connection (page 16) and follow steps 4 - 19,
in order to access the built-in Web interface.
Digital and Analog Audio over IP - Sender
6.
Make note of both IP addresses. These IP addresses can be entered in a Web browser to
access the built-in Web interface.
20
Digital and Analog Audio over IP - Receiver
Installation
7.
Set the audio channel. By default, both the Sender and Receiver unit are set
to channel 0. See Setting the Audio Channel (page 25) for more information.
8.
Once both Sender and Receiver units are configured using the built-in Web
interface, the shielded CAT-5e cable, between the PC and the Receiver unit,
can be disconnected.
9.
See Supplementary Connections (page 22) for instructions on connecting IR, RS-232,
and audio cables.
21
Installation
►► IR
Supplementary Connections
1.
Connect an IR Emitter (Gefen part no. EXT-IREMIT) to the IR Out port on the Sender unit
and attach it to the IR sensor on the device to be controlled.
2.
Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to the IR In/Ext port on the
Sender unit to control the AV receiver.
3.
Connect an IR Emitter (Gefen part no. EXT-IREMIT) to the IR Out port on the Receiver unit
and attach it to the IR sensor on the device to be controlled.
4.
Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to the IR In/Ext port on the
Receiver unit to control the audio source.
►► Audio
See Audio Connections (page 43) for more information on connections and port
priorities.
5.
Connect a 3.5mm mini-stereo cable from the Line In*** port on the Sender unit to the
analog audio source.
6.
Connect a optical audio cable from the Opt In*** port on the Sender unit to the TOSLINK®
connector on the audio source.
7.
Connect a digital audio coaxial cable from the Coax In*** port on the Sender unit, to the
digital audio source.
8.
Connect a 3.5mm mini-stereo cable from the Line Out**** port on the Receiver unit to
the analog audio amplifier.
9.
Connect a optical audio cable from the Opt Out**** port on the Receiver unit to the
TOSLINK® input port on the audio amplifier.
10. Connect a digital audio coaxial cable from the Coax Out**** port on the Receiver unit to
the digital audio input port on the audio amplifier.
►► RS-232
12. Connect an RS-232 cable from the PC or automation system to the RS-232 port on the
Sender unit.
13.
Connect an RS-232 cable from the Receiver unit to the RS-232 device to be controlled.
*** Please note that when Line In on Sender is plugged in, it takes priority over the two digital inputs. If Line
In is not connected, the two digital ports have the same priority. First one connected will be active. If both
digital ports are connected and then the unit is powered on, Opt In will be active. To avoid inconsistent and/
or confusing user experience, we recommend that only one type of input is connected at a time.
**** All three audio outputs of the Receiver can be used simultaneously, but if the signal format is Bitstream, the
analog output will not work.
22
Installation
Sample Wiring Diagram
Blu-ray
Player
IR Emitter
Automation
Control Device
CAT-5e CABLE
RS-232 CABLE
3.5MM AUDIO CABLE
OPTICAL DIGITAL AUDIO
COAXIAL DIGITAL AUDIO
IR IN
IR OUT
To
PoE
IP Switch
EXT-ADA-LAN-TX
5V DC
LAN (PoE)
RS-232
IR In/Ext
IR Out
Line In
Opt In
Coax In
EXT-ADA-LAN
Sender
Blu-ray
Player
OR OR
IR Extender
for remote amplifier control
RS-232
Controlled Device
IR Extender
for source control
Analog
Audio Source
To
PoE
IP Switch
Powered Speakers
or Audio Amplifier
w/analog L/R input
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
EXT-ADA-LAN
Receiver
Audio Amplifier
w/ S/PDIF digital input
Audio Amplifier
w/ optical digital input
IR Emitter
All three audio outputs of the Receiver can be used simultaneously, but if the signal format is Bitstream, the analog output will not work.
EXT-ADA-LAN
Note
The wiring diagrams above show an additional IR Emitter (Gefen part no. EXTIREMIT), an additional IR Extender Module (Gefen part no. EXT-RMT-EXTIRN),
and various interconnect cables that are not included with the products. The
Emitter, Extender Module, and select cables are available for purchase from your
Gefen dealer or distributor.
23
LED Status
The Power and Link LED indicators on the Sender and Receiver unit provide basic information
on their current status.
The information, in the tables below, applies to both the Sender and Receiver unit.
Link
Status
Description
Off
•
Connection is not established.
•
Check the cable between the Sender and Receiver
unit.
On
•
Connection is established and audio is streaming.
Blinking
•
System is in a state of transition. Connection is
established but streaming has not started.
•
No audio source detected.
•
Check that the Receiver unit is connected to the
host.
Power
Status
Description
Off
•
No power.
On
•
Power is on and the system is ready.
Blinking
•
System is booting (not ready).
24
Setting the Audio Channel
In order for a Sender and Receiver unit to communicate with one another, they must both be
set to the same channel. This is similar to changing the channel on a set-top box in order to
view a different program. Pressing and releasing either the CH + or CH - buttons on the front
of the Receiver unit can also be used to change the channel. Both methods will be covered in
this section. By default, all Sender and Receiver units are set to channel 0 (zero).
Setting the Channel using the Web Interface
1.
Access the Web interface by entering the IP address of the desired Sender or Receiver
unit.
2.
Login as “Administrator” or “User”.
3.
Click the Functions tab. The current channel is displayed within the Channel Setup
window group.
4.
Type the desired channel number. Channel numbers can range from 0 to 39900.
5.
Click the Apply button on the right-hand side of Channel Setup window group.
6.
The following message will be displayed, at the top of the page, indicating that the
selected channel has been applied.
If the entered value is invalid, then the following message will be displayed:
7.
Access the Web interface of the next unit (Sender or Receiver) by entering its
IP address.
8.
Repeat steps 1 - 5 for each Sender and Receiver to be changed.
25
Setting the Audio Channel
EXT-ADA-LAN-RX
Setting the Channel using the Front Panel
1.
Press the CH - or CH + change the current channel number. Channel numbers range from
0 to 39900 and can be viewed in the Web interface.
–
On
Power
Link
Reset
Prog
CH
+
Off
Prog Sel
Receiver unit
To set the audio channel on a Sender unit, use the Web interface. See Setting the Channel using the Web Interface (page 25) for more information.
EXT-ADA-LAN-RX
The illustration below shows one Receiver unit and three Sender units. The numbers indicate Coax
theOut
audioOptchannel
for each
unit. IRHere,
theIR Out
ReceiverLAN
unit
is currently
set
to channel
Out
Line Out
RS-232
In/Ext
1
LAN 2 (PoE)
5V DC
2 and is receiving the signal from the Sender unit, set to channel 2.
Receiver unit
Out
LAN
2
Sender unit
2
Sender unit
1
In
Sender unit
5
In
Digital and Analog Audio over IP - Receiver
In
To switch the channel, and view the source that is connected to the Sender on channel
5, press and release the CH + button to increment the channel. The web interface will
reflect the current channel change.
26
Setting the Audio Channel
2.
The Receiver unit, on channel 5, is now receiving the signal from the Sender unit on
channel 5.
Receiver unit
Out
LAN
5
Sender unit
2
Sender unit
1
In
Sender unit
5
In
In
27
Muting Audio
Use the Mute Audio option on a Sender unit to prevent audio from being transmitted to each
of the connected Receiver units (multicast mode only). Use the Mute Audio option on the
Receiver units, to selectively block audio on each Receiver unit.
►► Receiver Units
1.
Access the Web interface of a Receiver unit by entering the IP address in the address bar
of the browser.
2.
Login as “Administrator”.
3.
Click the Functions tab.
4.
Under the Audio over IP window group, check the Audio Mute box to block the audio
output on the Receiver unit. Deselect this check box to re-enable audio.
5.
Click the Apply button within the Audio over IP group.
6.
Repeat steps 1 through 5 for each Receiver unit in the system.
28
Muting Audio
►► Sender Units
Note
The Mute Audio option on Sender units is only applicable in multicast mode.
1.
Access the Web interface of a Sender unit by entering the IP address in the address bar of
the browser.
2.
Login as “Administrator”.
3.
Click the Functions tab.
4.
Under the Audio over IP window group, check the Audio Mute box to prevent audio from
being transmitted to each of the connected Receiver units. Deselect this check box to
re-enable audio output on all connected Receiver units..
5.
Click the Apply button within the Audio over IP group.
6.
Repeat steps 1 through 5 for each Sender unit in the system.
29
Unicast & Multicast Modes
Configuring Unicast Mode
The term unicast is used to describe a configuration where information is sent from one point
to another point. It is possible to have multiple Sender and Receiver units connected in a
system. However, in unicast mode a Sender unit can communicate with only one Receiver unit
at a time. In unicast mode, the Gefen AV over IP products function similar to an audio switcher.
Note
The Gefen Audio over IP Sender and Receiver units are shipped from the factory in
unicast mode.
The illustration, below, shows 3 Sender units (S1, S2, and S3) and 2 Receiver units
(R1 and R2) on a network, operating in unicast mode. The audio channels are notated
in blue.
Figure 2.1 - Unicast mode: A Sender unit can communicate with only one Receiver unit at a time.
Receiver unit
Out
2
LAN
R
2
Sender unit
Receiver unit
1
S
2
R
3
Out
1
Sender unit
In
S
2
1
Sender unit
S
In
1
5
In
1.
Access the Web interface for each Sender and Receiver unit that will be using unicast
mode. In this example, we will start with Receiver unit R1.
2.
Login as “Administrator”.
Tip
In unicast mode, the Gefen AV over IP Senders and Receivers function as an audio
switcher.
30
Unicast & Multicast Modes
3.
Click the Network tab.
4.
Click the Unicast button under the Network Mode window group. When selected,
the Unicast button will be highlighted in red.
5.
Click the Apply button in the lower-right corner of the Network Mode group.
6.
The following message will be displayed, at the top of the page, indicating that the
casting mode has been applied to the Sender or Receiver unit.
7.
Click the Reboot button at the bottom of the page. If the Reboot button is not clicked,
the following message will be displayed, indicating that the unit must be rebooted.
8.
Repeat steps 1 - 7 in order to configure the Sender unit for unicast mode.
Important
When switching between unicast and multicast modes, both Sender and Receiver
units must be set to the same mode.
31
Unicast & Multicast Modes
Switching between Sender units in Unicast mode
When multiple Sender and Receiver unit are used in unicast mode, the Gefen Audio over IP
Sender and Receivers behave as a switcher. In unicast mode, a Sender unit can communicate
with only one Receiver unit at a time.
In the example below, Receiver unit R1 will be switched to receive the source connected to
Sender unit S1. To do this, simply change the audio channel.
Figure 2.2 - Unicast mode: Receiver unit R1 is connected to Sender unit S2.
Receiver unit
Out
2
LAN
R
2
Sender unit
Receiver unit
1
S
2
R
3
Out
1
Sender unit
In
S
2
1
Sender unit
S
In
1
5
In
1.
Access the Web interface for Receiver unit R1.
2.
Login as “Administrator”.
3.
Click the Network tab and change the audio channel. Refer to Setting the Audio
Channel (page 25) if necessary.
4.
Click the Apply button.
5.
The following message will be displayed, at the top of the page, indicating that the
new channel has been applied to the Sender or Receiver unit.
6.
Receiver unit R1 is now receiving the audio source connected to Sender unit S1, as
shown on the next page.
32
Unicast & Multicast Modes
Figure 2.3 - Unicast mode: Receiver unit R1 is now connected to Sender unit S1.
Receiver unit
Out
2
LAN
R
Sender unit
2
Out
Receiver unit
3
Sender unit
1
5
S
2
R
In
S
2
1
Sender unit
In
S
1
5
In
Now, observe the result when both Sender S1 and S2 are set to channel 5:
Figure 2.4 - Unicast mode violation: Two Sender units (S1 and S2) using the same audio channel.
Receiver unit
Out
2
LAN
R
Sender unit
2
Out
Receiver unit
2
S
3
R
Sender unit
1
5
In
5
2
S
Sender unit
In
S
1
5
In
In this example, Receiver R1 will continue to receive audio data from Sender S1,
even though Sender S2 is set to the same audio channel. The reason for this is
because Receiver R1 and Sender S1 were already set to the same audio channel
and communicating (as depicted in Figure 2.3). However, this scenario violates the
unicast mode rule: A Sender unit can communicate with only one Receiver unit
at a time.
33
Unicast & Multicast Modes
When using unicast mode, each of the Sender units must be assigned a unique
audio channel and should never be changed. Use the Receiver unit to switch (channels)
between Sender units.
Note
In unicast mode, if an additional Sender unit is introduced into a system with the
same channel as another Sender unit, then the Receiver unit will continue to receive
audio data from the Sender unit which was connected first.
34
Unicast & Multicast Modes
Configuring Multicast Mode
The term multicast is used to describe a configuration where information is sent from one or
more points to a set of other points. For example, a single Sender unit can transmit data to
multiple Receiver units. In addition, if multiple Sender units are used, each Sender unit can
transmit data to any Receiver that is not already receiving data from another Sender unit.
In multicast mode, the Senders and Receivers function similar to a KVM matrix.
The illustration, below, shows 3 Sender units (S1, S2, and S3) and 2 Receiver units
(R1 and R2) on a network, operating in multicast mode. The audio channels are shown
in blue.
Figure 2.5 - Multicast mode: A Sender unit can communicate with multiple Receiver units.
Receiver unit
Out
1
LAN
R
2
Sender unit
Receiver unit
1
2
R
S
3
Out
1
Sender unit
In
1
2
S
Sender unit
In
S
1
5
In
1.
Access the Web interface for each Sender and Receiver unit that will be using multicast
mode. In this example, we will start with Receiver S2.
2.
Login as “Administrator”.
Note
In multicast mode, the Gefen AV over IP Senders and Receivers function as an audio
matrix.
35
Unicast & Multicast Modes
3.
Click the Network tab.
4.
Click the Multicast button under the Network Mode window group. When selected,
the Multicast button will be highlighted in red.
5.
Click the Apply button in the lower-right corner of the Network Mode group.
The following message will be displayed, at the top of the page, indicating that the
casting mode has been applied to the Sender or Receiver unit.
6.
Click the Reboot button at the bottom of the page. If the Reboot button is not clicked,
the following message will be displayed, indicating that the unit must be rebooted.
7.
Repeat the steps above in order to configure the Sender unit to multicast mode.
Important
When switching between unicast and multicast modes, both Sender and Receiver
units must be set to the same mode.
36
Discovery Mode
Gefen Syner-G Discovery
Enabling the Gefen Syner-G Discovery feature allows the Gefen Syner-G Software Suite or
Gefen Discovery Tool App to locate a Sender and/or Receiver on a network. Once the software
is able to locate the unit, IP settings can be changed as desired.
1.
Access the Web interface by entering the IP address of a Receiver or Sender unit.
2.
Login as “Administrator”.
3.
Click the Network tab.
4.
Under the IP Setup window group, check the Gefen Syner-G Discovery box to
allow the Gefen Syner-G software to locate the unit. If you do not want the unit to be
discoverable, then un-check this box.
5.
Click the Apply button.
6.
Click the Reboot button at the bottom of the page to restart the unit and apply
the change.
37
Discovery Mode
Finding Your Device
If several Sender and Receiver unit pairs are connected on a network, you may need to
physically identify a particular Sender and/or Receiver unit. In such a case, use the Find Your
Device feature.
1.
Access the Web interface by entering the IP address of a Receiver or Sender unit.
2.
Login as “Administrator”.
3.
Click the Network tab.
4.
Under the IP Setup window group, click the Show Me button. By default, the Hide Me
button will be selected.
Although shown, below, it is not necessary to have the Gefen Syner-G Discovery
option enabled in order to use the Find Your Device feature.
38
Discovery Mode
5. The following message will be displayed, at the top of the page, indicating that the
EXT-ADA-LAN-RX
LED indicators on the unit are blinking.
6.
The Power and Link LED indicators will continue to blink until the Hide Me button is
clicked.
–
On
Power
Link
Reset
Prog
CH
+
Off
Prog Sel
Receiver unit (shown)
7.
Click the Hide Me button to stop both LED indicators from blinking.
EXT-ADA-LAN-RX
Coax Out
8.
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
The Power and Link LED indicators will stop blinking and the following message will
be displayed at the top of the page.
Digital and Analog Audio over IP - Receiver
39
RS-232 Control
The Gefen Audio over IP Senders and Receivers support RS-232 pass-through, allowing the
control of remote RS-232 devices. The Sender and Receiver unit which are being used to passthrough the RS-232 data must be set to the same baud rate as the RS-232 host and client.
In the example below, an RS-232 device has been connected to Receiver R1. We want to control
this product from Sender unit S3, using an automation control device. The channel numbers
are listed in blue.
Figure 2.6 - Basic RS-232 connection
Receiver unit
Out
R
02
2
Sender unit
Receiver unit
1
R
S
12
3
Out
Automation
Control Device
LAN
Sender unit
12
In
2
S
Sender unit
09
S
In
1
RS-232 device
05
In
Table 2.1 - RS-232 settings for an arbitrary RS-232 device.
Description
Setting
Baud rate
19200
Data bits
Parity
Stop bits
Hardware flow control
8
None
1
None
Confirm that the same RS-232 settings are assigned to both the Sender and Receiver units. To
do this, access the Web interface on both the required Sender unit and Receiver unit to set the
proper RS-232 settings. Follow the instructions on the next page.
40
RS-232 Control
1.
Access the Web interface for the Sender unit and login as “Administrator”.
2.
Click the Functions tab.
3.
Locate the Serial over IP group and change the RS-232 settings to match the
settings of the RS-232 device that is being used. In this case, we need to use the settings
from Table 2.1 (see previous page).
4.
Make sure that the Enable Serial over IP box is checked.
5.
Click the Apply button in the lower-right corner of the Serial over IP group.
Important
If Enable Serial over IP is not checked, then RS-232 pass-through will be disabled.
6.
The following message will be displayed, at the top of the page, indicating that the new
Serial over IP options have been applied.
7.
Click the Reboot button at the bottom of the page. If the Reboot button is not clicked,
the following message will be displayed, indicating that the unit must be rebooted.
8.
Repeat steps 1 - 7 for the Receiver unit.
41
RS-232 Control
RS-232 under Unicast Mode
In unicast mode, a Sender unit will be able to communicate with only one Receiver unit
at a time.
Figure 2.7 - In unicast mode, the host can talk to only one RS-232 device at a time.
RS-232 device
Receiver unit
Out
R
02
2
Out
Automation
Control Device
LAN
Sender unit
Receiver unit
S
3
R
1
12
Sender unit
12
S
2
RS-232 device
In
Sender unit
09
In
1
S
05
In
RS-232 under Multicast Mode
In multicast mode, a Sender unit can communicate with multiple Receiver units
simultaneously.
Figure 2.8 - In multicast mode, the host can talk to multiple RS-232 devices.
RS-232 device
Receiver unit
Out
R
12
2
Sender unit
Receiver unit
1
R
12
S
3
Out
Automation
Control Device
LAN
Sender unit
12
S
2
RS-232 device
Sender unit
09
1
S
05
In
42
In
In
Audio Connections
Audio works in both unicast and multicast modes. However, audio connections have different
priorities, based on the type and the order in which they are connected.
Sender Unit
1.
EXT-ADA-LAN-TX
Connect a 3.5mm mini-stereo cable from the Line In*** port on the Sender unit to the
analog audio source.
2.
Connect a optical audio cable from the Opt In*** port on the Sender unit to the TOSLINK®
connector on the audio source.
3.
Connect a digital audio coaxial cable from
the Coax In*** port on the Sender unit, to the
On
Off
Power Link
Prog Sel
digital audio
source. Reset Prog
Connect to Line Out on analog source
EXT-ADA-LAN-TX
5V DC
LAN (PoE)
RS-232
IR In/Ext
IR Out
Line In
Opt In
Coax In
Sender unit
Connect to optical audio output
on source
Connect to digital audio output
on source
*** See Audio Port Priority section.
Receiver Unit
1.
Connect a 3.5mm mini-stereo cable from the Line Out**** port on the Receiver unit to
powered speakers or an audio amplifier.
2.
Connect a optical digital audio cable with TOSLINK® connectors from the Opt Out****
Digital and Analog Audio over IP - Sender
port on the Receiver unit to the digital input of an audio amplifier.
3.
Connect a coaxial digital audio cable from the Coax Out**** port on the Receiver unit to
the digital input port of an audio amplifer.
43
–
On
Power
Link
Reset
Prog
CH
+
Audio Connections
Off
Prog Sel
Connect to powered speakers or
audio amplifier
Receiver unit
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
Connect to optical audio input
on audio amplifier
Connect to digital audio input
on audio amplifier
**** See Audio Port Priority section.
Digital and Analog Audio over IP - Receiver
Audio Port Priority
When the Line In port on the Sender unit is connected, it takes priority over both digital inputs
(Opt In and Coax In). If Line In is not connected, then the two digital ports have the same
priority. The first digital port that receives a connection will become the active audio input
port. If both digital ports are connected, after the unit is powered-on, then the Opt In port
always has priority and will become the active audio input port.
All three audio ports (Line Out, Opt Out, and Coax Out) output the same audio signal.
See the table on the following page for a summary of audio port priorities.
44
Audio Connections
Audio Port Priority Summary
Transmitter
Line In
Opt In
Receiver
Coax In
Line Out
Opt Out
Coax Out
Line In
Line In
Line In
Opt In
Opt In
Opt In
Coax In
Coax In
Coax In
Line In
Line In
Line In
Line In
Line In
Line In
First
Second
Opt In
Opt In
Opt In
Second
First
Coax In
Coax In
Coax In
Line In
Line In
Line In
45
Changing the Password
1.
Access the Web interface for the Sender / Receiver unit.
2.
Login as “Administrator”.
3.
Click the System tab.
4.
Under the Password Change window group, enter the new password for the desired
username. Note that the new password will not be masked when it is entered.
5.
Click the Change button.
46
Utilities
Reset using the Web Interface
All Senders and Receivers can be reset using the web interface or using the buttons on the
front panel. When using the Web interface, the Sender / Receiver units will automatically be
reset to Auto IP mode. When using the front-panel buttons, the Sender / Receiver can be reset
to either Auto IP or Static IP mode.
Note
Once a unit has been reset to Auto IP mode, the connection to the Web interface
will be terminated. To reestablish a connection to the Web interface, from your
computer, see Installation (page 17).
1.
Access the Web interface for the desired Sender / Receiver unit. It does not matter which
unit is reset first.
2.
Login as “Administrator”.
3.
Click the System tab.
4.
Click the Utilities rollout.
5.
Click the Factory Default button.
47
Utilities
5.
Both the Power and Link LED indicators will begin to flash.
–
On
Power
Link
Reset
Prog
CH
+
Off
Prog Sel
Receiver unit (shown)
6.
After both LED indicators stop flashing, the unit will be reset.
7.
Repeat the process for each unit.
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
Digital and Analog Audio over IP - Receiver
48
Utilities
Reboot using the Web Interface
The Sender and Receiver units can be rebooted in three different ways: Using the Web
interface, the Reset button on the front panel, or simply disconnecting and reconnecting the
power.
1.
Access the Web interface for the Sender / Receiver unit.
2.
Login as “Administrator”.
3.
Click the System tab.
4.
Click the Utilities rollout.
5.
Click the Reboot button.
6.
After a few moments, the Power LED indicator will flash.
7.
Several seconds later, the Power LED indicator will glow solid blue and the Link LED
indicator will begin to flash.
8.
After both LED indicators stop flashing, the reboot process will be complete.
49
Utilities
Reboot using the Front Panel
1.
Press the Reset button, on the desired Sender or Receiver unit, using the end
of a paper clip or other sharp pointed object.
2.
After a few moments, the Power LED indicator will flash.
3.
Several seconds later, the Power LED indicator will glow solid blue and the Link LED
indicator will begin to flash.
4.
After both LED indicators stop flashing, the reboot process will be complete.
EXT-ADA-LAN-TX
Reset button
EXT-ADA-LAN-RX
On
Power
Link
Reset
Prog
Off
Prog Sel
Sender unit
Reset button
EXT-ADA-LAN-TX
–
5V DC
Power
Off
RS-232 On IR In/Ext
LAN (PoE)
Link
Reset
Prog
CH
IR Out
+
Line In
Opt In
Coax In
Prog Sel
Receiver unit
EXT-ADA-LAN-RX
Coax Out
Opt Out
Line Out
RS-232
IR In/Ext
IR Out
LAN 1
LAN 2 (PoE)
5V DC
Digital and Analog Audio over IP - Sender
50
Telnet Access
Note
By default, the Telnet login credentials are disabled. This setting is required when
using the Matrix controller (Gefen part no. EXT-CU-LAN) but can be enabled for
security purposes. Use the #use_telnet_login command to enable or
disable this feature.
1.
Launch the desired terminal application (e.g. Windows Hyperterminal, etc).
2.
Within the terminal program, enter the IP address of the Sender or Receiver unit that you
wish to control.
3.
Enter the TCP listening port. The default listening port is 23.
4.
After the correct settings have been used in the terminal program, information similar to
the following will be displayed.
In the example, below, we are connected to the client (Receiver unit) and Telnet login has
been enabled:
------------- Welcome to the Gefen Telnet Server ---------ast2-client001C9103C8B3 login:
5.
Login as “Administrator”. The default password is “admin”. To change the Telnet password, see the #set_telnet_pass command.
6.
Type #help for a list of commands or refer to the tables on the following pages.
51
Commands
Important
Commands that are limited to a Sender or Receiver unit are marked as “Tx only”
and “Rx only”, respectively. Unless otherwise noted, commands can be used when
connected to either a Sender or Receiver unit.
Discovery Service
Command
Description
#get_device_desc
Displays the device description
#get_discovery
Displays the current state of the discovery service
#get_discovery_mode
Displays the discovery read/write mode
#get_showme
Displays the status of the showme state
#set_device_desc
Sets the device description
#set_discovery
Enables or disables the discovery service
#set_discovery_mode
Sets the discovery mode
#set_showme
Enables or disables the “show me” feature
Help
Command
Description
#help
Displays a list of available commands
Network
Command
Description
#get_gateway
Displays the gateway IP address
#get_ip_address
Displays the IP address
#get_ip_mode
Displays the IP mode
#get_ipconfig
Displays the IP configuration information
#get_net_mode
Displays the network casting mode
#get_netmask
Displays the subnet mask address
#get_remote_udp_access
Displays the remote UDP access state
#get_remote_udp_ip
Displays the remote UDP IP address
#get_remote_udp_port
Displays the remote UDP listening port
#get_telnet_access
Displays the Telnet access state
52
Commands
Command
Description
#get_telnet_login
Displays the status of the Telnet login
#get_telnet_port
Displays the Telnet listening port
#get_telnet_welcome
Displays the Telnet welcome message
#get_udp_access
Displays the UDP access state
#get_udp_port
Displays the UDP listening port
#get_web_port
Displays the HTTP listening port
#set_gateway
Sets the gateway address
#set_ip_address
Sets the IP address
#set_ip_mode
Sets the IP mode
#set_net_mode
Sets the network casting mode
#set_netmask
Sets the subnet mask address
#set_remote_udp_access
Enables or disables remote UDP access
#set_remote_udp_ip
Sets the remote UDP IP address
#set_remote_udp_port
Sets the remote UDP listening port
#set_telnet_access
Enables or disables Telnet access
#set_telnet_login
Enables or disables the Telnet login
#set_telnet_pass
Sets the Telnet password
#set_telnet_port
Sets the Telnet listening port
#set_telnet_welcome
Sets the Telnet welcome message
#set_udp_access
Enables or disables UDP access
#set_udp_port
Sets the UDP listening port
#set_web_port
Sets the HTTP listening port
Routing
Command
Description
#get_rx_channel
Displays the channel of the Receiver unit (Rx only)
r
Routes an input to a Receiver unit (Rx only)
53
Commands
RX Specific
Command
Description
#get_clk_lock
Displays the audio clock lock
#get_rx_id
Displays the ID of the Receiver unit
#get_rx_mute
Displays the audio mute feature state
#set_clk_lock
Sets the audio clock lock
#set_rx_id
Sets the ID of the Receiver unit
#set_rx_mute
Sets the audio mute feature
54
Commands
Serial
Command
Description
#get_serial_allow
Displays the Serial-over-IP state
#get_serial_baud
Displays the serial baud rate setting
#get_serial_bits
Displays the serial data bits setting
#get_serial_parity
Displays the serial parity setting
#get_serial_stop
Displays the serial stop bits setting
#set_serial_allow
Enables or disables Serial-over-IP mode
#set_serial_baud
Sets the baud rate for the serial port
#set_serial_bits
Sets the data bits for the serial port
#set_serial_parity
Sets the parity setting for the serial port
#set_serial_stop
Sets the number of stop bits for the serial port
System
Command
Description
#get_firmware_version
Displays the firmware version
#factory_reset
Resets the unit to factory-default settings
#fw_upgrade
Upgrades firmware using external file
#reboot
Reboots the unit
TX Specific
Command
Description
#get_tx_channel
Displays the audio channel
#set_tx_channel
Sets the audio channel
Web Interface
Command
Description
#set_webui_ad_pass
Sets the administrator password for the web UI
#set_webui_user_pass
Sets the user password for the web UI
55
Commands
#help
Displays a list of available commands. The commands listed are specific to either the Sender
or Receiver unit.
Syntax
#help
Parameters
None
Example
#help
#HELP
#FACTORY_RESET
#FW_UPGRADE
#GET_CLK_LOCK
#GET_DEVICE_DESC
#GET_DISCOVERY
#GET_DISCOVERY_MODE
#GET_EDID_COPY
#GET_FIRMWARE_VERSION
#GET_GATEWAY
#GET_HDCP
#GET_IP_ADDRESS
#GET_IP_MODE
#GET_IPCONFIG
#GET_NET_MODE
#GET_NETMASK
#GET_REMOTE_UDP_ACCESS
#GET_REMOTE_UDP_IP
#GET_REMOTE_UDP_PORT
#GET_RX_CHANNEL
...
...
56
Commands
#factory_reset
Resets the unit to factory-default settings. param1 must be included and set to 1.
Syntax
#factory_reset param1
Parameters
param1
Integer1
Example
#factory_reset 1
RESET TO FACTORY DEFAULTS
Related Commands
#reboot
57
Commands
#fw_upgrade
Upgrades the firmware from the command.
Syntax
#fw_upgrade filename
Parameters
filename String
Example
#fw_upgrade firmware_file_v2.bin
58
Commands
#get_clk_lock
Displays the audio clock lock.
Syntax
#get_clk_lock
Parameters
None
Example
#get_clk_lock
CLK_LOCK 0
Related Commands
#set_clk_lock
59
Commands
#get_device_desc
Displays the description of the Sender / Receiver unit.
Syntax
#get_device_desc
Parameters
None
Example
#get_device_desc
DEVICE DESCRIPTION IS Genius Sender 2
Related Commands
#set_device_desc
60
Commands
#get_discovery
Displays the current discovery mode setting.
Syntax
#get_discovery
Parameters
None
Example
#get_discovery
DISCOVERY SERVICE SET TO ENABLED
Related Commands
#set_discovery
#set_showme
61
Commands
#get_discovery_mode
Displays the current discovery mode setting.
Syntax
#get_discovery_mode
Parameters
None
Example
#get_discovery_mode
DISCOVERY MODE 1
Related Commands
#set_discovery
#set_discovery_mode
#set_showme
62
Commands
#get_firmware_version
Displays the firmware version.
Syntax
#get_firmware_version
Parameters
None
Example
#get_firmware_version
FIRMWARE VERSION IS 1.83hv
Related Commands
#fw_upgrade
63
Commands
#get_gateway
Displays the gateway address of the Sender/Receiver unit.
Syntax
#get_gateway
Parameters
None
Example
#get_gateway
GATEWAY: 192.168.0.1
Related Commands
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
64
Commands
#get_ip_address
Displays the current IP address of the Sender or Receiver unit.
Syntax
#get_ip_address
Parameters
None
Example
#get_ip_address
IP: 10.5.64.60
Related Commands
#get_gateway
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
65
Commands
#get_ip_mode
Displays the current IP mode.
Syntax
#get_ip_mode
Parameters
None
Example
#get_ip_mode
IP MODE IS SET TO DHCP
Related Commands
#get_gateway
#get_ip_address
#get_ipconfig
#get_netmask
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
66
Commands
#get_ipconfig
Displays the current IP configuration. In addition to providing the MAC address and the
broadcast IP address, this command also provides the same information as executing the
#get_ip_mode, #get_ip_address, #get_netmask, and #get_gateway
commands.
Syntax
#get_ipconfig
Parameters
None
Example
#get_ipconfig
IP CONFIGURATION IS :
IP MODE: DHCP
IP: 10.5.64.60
NETMASK: 255.255.255.0
GATEWAY: 10.5.64.1
MAC ADDRESS: 00-1C-91-03-C8-B3
Related Commands
#get_gateway
#get_ip_address
#get_netmask
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
67
Commands
#get_net_mode
Displays the current network mode setting.
Syntax
#get_net_mode
Parameters
None
Example
#get_net_mode
NETWORK MODE SET TO MULTICAST
Related Commands
#set_net_mode
68
Commands
#get_netmask
Displays the current net mask setting.
Syntax
#get_netmask
Parameters
None
Example
#get_netmask
NETMASK: 255.255.255.0
Related Commands
#get_gateway
#get_ip_address
#get_ipconfig
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
69
Commands
#get_remote_udp_access
Displays the remote UDP access state.
Syntax
#get_remote_udp_access
Parameters
None
Example
#get_remote_udp_access
REMOTE UDP ACCESS IS ENABLED
Related Commands
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
70
Commands
#get_remote_udp_ip
Displays the remote UDP IP address.
Syntax
#get_remote_udp_ip
Parameters
None
Example
#get_remote_udp_access
REMOTE UDP IP: 192.168.1.29
Related Commands
#get_remote_udp_access
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
71
Commands
#get_remote_udp_port
Displays the remote UDP listening port.
Syntax
#get_remote_udp_port
Parameters
None
Example
#get_remote_udp_port
REMOTE UDP COMMUNICATIONS PORT: 50008
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
72
Commands
#get_rx_channel
Displays the current channel of the Receiver unit. To set the audio channel of a Receiver unit,
use the #set_rx_id command.
Syntax
#get_rx_channel
Parameters
None
Example
#get_rx_channel
RECEIVER CHANNEL: 1
Related Commands
#get_tx_channel
#set_tx_channel
r
73
Commands
#get_rx_id
Displays the ID of the Receiver unit. This command is only available when connected
to a Receiver unit.
Syntax
#get_rx_id
Parameters
None
Example
#get_rx_id
RX ID: 8
Related Commands
#set_rx_id
74
Commands
#get_rx_mute
Displays the audio mute feature state. Use the #set_rx_mute command to set
enable/disable the audio mute feature. This command is only available when connected
to a Receiver unit.
Syntax
#get_rx_mute
Parameters
None
Example
#get_rx_mute
RX_MUTE 0
Related Commands
#set_rx_mute
75
Commands
#get_serial_allow
Displays the Serial-over-IP state. Use the #set_serial_allow command to enable
or disable the Serial-over-IP feature.
Syntax
#get_serial_allow
Parameters
None
Example
#get_serial_allow
SERIAL OVER IP is ENABLE
Related Commands
#get_serial_baud
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
76
Commands
#get_serial_baud
Displays the serial baud rate setting. Use the #set_serial_baud command to set
the baud rate.
Syntax
#get_serial_baud
Parameters
None
Example
#get_serial_baud
SERIAL BAUD RATE IS 19200
Related Commands
#get_serial_allow
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
77
Commands
#get_serial_bits
Displays the serial data bits setting. Use the #set_serial_bits command to set
the number of data bits.
Syntax
#get_serial_bits
Parameters
None
Example
#get_serial_bits
SERIAL DATA BITS IS 8
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
78
Commands
#get_serial_parity
Displays the serial parity bit setting. Use the #set_serial_parity command to set
the parity bit.
Syntax
#get_serial_parity
Parameters
None
Example
#get_serial_parity
SERIAL PARITY MODE SET TO NONE
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
79
Commands
#get_serial_stop
Displays the serial stop bits setting. Use the #set_serial_stop command to set
the number of stop bits.
Syntax
#get_serial_stop
Parameters
None
Example
#get_serial_stop
SERIAL STOP BITS IS 1
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
80
Commands
#get_showme
Displays the showme state.
Syntax
#get_showme
Parameters
None
Example
#get_showme
SHOW ME DISABLED
Related Commands
#set_showme
81
Commands
#get_telnet_access
Displays the Telnet access state. Use the #set_telnet_access command to enable
or disable Telnet access.
Syntax
#get_telnet_access
Parameters
None
Example
#get_telnet_access
TELNET ACCESS IS ENABLED
Related Commands
#get_telnet_login
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_pass
#set_telnet_login
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
82
Commands
#get_telnet_login
Displays the Telnet login status.
Syntax
#get_telnet_login
Parameters
None
Example
#get_telnet_login
TELNET LOGIN SET TO DISABLED
Related Commands
#get_telnet_access
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_pass
#set_telnet_login
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
83
Commands
#get_telnet_port
Displays the Telnet listening port.
Syntax
#get_telnet_port
Parameters
None
Example
#get_telnet_port
TELNET COMMUNICATION PORT: 23
Related Commands
#get_telnet_access
#get_telnet_login
#get_telnet_welcome
#set_telnet_access
#set_telnet_pass
#set_telnet_login
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
84
Commands
#get_telnet_welcome
Displays the Telnet welcome message. Use the #set_telnet_welcome to create
a custom welcome message.
Syntax
#get_telnet_welcome
Parameters
None
Example
#get_telnet_welcome
TELNET WELCOME SCREEN IS DISABLED
Related Commands
#get_telnet_access
#get_telnet_login
#get_telnet_port
#set_telnet_access
#set_telnet_pass
#set_telnet_login
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
85
Commands
#get_tx_channel
Displays the audio channel of the Sender unit. This command is only available when
connected to a Sender unit.
Syntax
#get_tx_channel
Parameters
None
Example
#get_tx_channel
TRANSMITTER CHANNEL: 1
Related Commands
#get_rx_channel
#set_tx_channel
r
86
Commands
#get_udp_access
Displays the UDP access state. Use the #set_udp_access command to enable
or disable UDP access.
Syntax
#get_udp_access
Parameters
None
Example
#get_udp_access
UDP ACCESS IS ENABLED
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
87
Commands
#get_udp_port
Displays the local UDP listening port.
Syntax
#get_udp_port
Parameters
None
Example
#get_udp_port
UDP PORT SET TO 50007
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
88
Commands
#get_web_port
Displays the HTTP listening port. Use the #set_web_port command to set the HTTP
listening port.
Syntax
#get_web_port
Parameters
None
Example
#get_web_port
WEB INTERFACE PORT: 80
Related Commands
#get_gateway
#get_ip_address
#get_ipconfig
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
89
Commands
#reboot
Reboots the Sender / Receiver unit.
Syntax
#reboot
Parameters
None
Example
#reboot
UNIT WILL REBOOT SHORTLY
Related Commands
#factory_reset
90
Commands
#set_clk_lock
Sets the audio clock lock. This command is only available on the Receiver unit. After executing
this command, the unit must be rebooted to apply the changes.
Syntax
#set_block param1
Parameters
param1
Integer[0 ... 500]
Example
#set_clk_lock 100
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_clk_lock
91
Commands
#set_device_desc
Sets the description for the Sender / Receiver unit. The description string cannot exceed 30
characters in length. Spaces and underscore characters are acceptable. Avoid using symbols
and special characters.
Syntax
#set_description param1
Parameters
param1
String
Example
#set_description Blu-ray_Panasonic
PRODUCT DESCRIPTION SET
Related Commands
#get_device_desc
92
Commands
#set_discovery
Enables or disables the discovery feature. The default value is On.
Syntax
#set_discovery param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Off
1
On
Example
#set_discovery 0
DISCOVERY SERVICE SET TO DISABLED
Related Commands
#get_discovery
#set_showme
#get_showme
93
Commands
#set_discovery_mode
Sets the discovery read / write mode.
Syntax
#set_discovery_mode param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Read only mode
1
Read / write mode
Example
#set_discovery_mode 1
DISCOVERY MODE 1
Related Commands
#get_edid_copy
94
Commands
#set_gateway
Sets the gateway address. This command is only applicable when using Static IP mode.
param1 must be specified using dot-decimal notation. After executing this command, the unit
must be rebooted to apply the changes.
Syntax
#set_gateway param1
Parameters
param1
IP Address
Example
#set_gateway 192.168.1.1
GATEWAY ADDRESS SET TO 192.168.1.1
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_ip_address
#set_ip_mode
#set_netmask
#set_web_port
95
Commands
#set_ip_address
Sets the IP address. param1 must be specified using dot-decimal notation. After executing
this command, the unit must be rebooted to apply the changes.
Syntax
#set_ip_address param1
Parameters
param1
IP Address
Example
#set_gateway 192.168.1.1
GATEWAY ADDRESS SET TO 192.168.1.1
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_gateway
#set_ip_mode
#set_netmask
#set_web_port
96
Commands
#set_ip_mode
Sets the IP mode. After executing this command, the unit must be rebooted to apply the
changes.
Syntax
#set_ip_mode param1
Parameters
param1
Integer[0 ... 2]
param1
Description
0
Static
1
2
DHCP
Auto IP
Example
#set_ip_mode 1
IP MODE SET TO DHCP
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_ip_address
#set_gateway
#set_netmask
#set_web_port
97
Commands
#set_net_mode
Sets the network casting mode.
Syntax
#set_net_mode param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Unicast
1
Multicast
Example
#set_net_mode 0
NETWORK CASTING MODE SET TO UNICAST
Related Commands
#get_net_mode
98
Commands
#set_netmask
Sets the network mask address. param1 must be specified using dot-decimal notation. After
executing this command, the unit must be rebooted to apply the changes.
Syntax
#set_netmask param1
Parameters
param1
IP Address
Example
#set_netmask 255.255.255.0
NETMASK ADDRESS SET TO 255.255.255.0
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_ip_address
#set_ip_mode
#set_gateway
#set_web_port
99
Commands
#set_remote_udp_access
Enables or disables remote UDP access. After executing this command, the unit must be
rebooted to apply the changes.
Syntax
#set_remote_udp_access param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_remote_udp_access 1
REMOTE UDP ACCESS SET TO ENABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
#set_udp_port
100
Commands
#set_remote_udp_ip
Set the remote UDP IP address. param1 must be specified using dot-decimal notation. After
executing this command, the unit must be rebooted to apply the changes.
Syntax
#set_remote_udp_ip param1
Parameters
param1
IP address
Example
#set_remote_udp_ip 192.168.1.29
REMOTE UDP IP ADDRESS SET TO 192.168.1.29
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_port
#set_udp_access
#set_udp_port
101
Commands
#set_remote_udp_port
Set the remote UDP listening port. After executing this command, the unit must be rebooted
to apply the changes.
Syntax
#set_remote_udp_port param1
Parameters
param1
Integer[0 ... 65535]
Example
#set_remote_udp_port 50008
REMOTE UDP COMMUNICATIONS PORT IS SET TO PORT 50008
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_udp_access
#set_udp_port
102
Commands
#set_rx_id
Sets the ID of the Receiver unit. This command is only available when connected
to a Receiver unit.
Syntax
#set_rx_id param1
Parameters
param1
Integer[0 ... 65535]
Example
#set_rx_id 1
RX ID: 1
Related Commands
#get_rx_id
103
Commands
#set_rx_mute
Enable or disable the audio mute feature. This command is only available when connected
to a Receiver unit.
Syntax
#set_rx_mute
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disable
1
Enable
Example
#set_rx_mute 0
RX_MUTE 0
Related Commands
#get_rx_mute
104
Commands
#set_serial_allow
Enables or disables serial over IP. After executing this command, the unit must be rebooted to
apply the changes.
Syntax
#set_serial_allow param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disable
1
Enable
Example
#set_serial_allow 0
SERIAL OVER IP SET TO DISABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
105
Commands
#set_serial_baud
Sets the baud rate for the serial port. After executing this command, the unit must be
rebooted to apply the changes.
Syntax
#set_serial_baud param1
Parameters
param1
Integer[0 ... 9]
param1
Description (baud rate)
0
300
1
2
3
4
5
6
7
8
Example
9
600
1200
2400
4800
9600
19200
38400
57600
115200
#set_serial_baud 6
SERIAL BAUD RATE SET TO 19200
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_bits
#set_serial_parity
#set_serial_stop
106
Commands
#set_serial_bits
Sets the data bits for the serial port. After executing this command, the unit must be rebooted
to apply the changes.
Syntax
#set_serial_bits param1
Parameters
param1
Integer[0 ... 3]
param1
Description (data bits)
0
5
1
2
3
6
7
8
Example
#set_serial_bits 3
SERIAL DATA BITS SET TO 8
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
#set_serial_stop
107
Commands
#set_serial_parity
Sets the parity bit for the serial port. After executing this command, the unit must be
rebooted to apply the changes.
Syntax
#set_serial_parity param1
Parameters
param1
Integer[0 ... 2]
param1
Description
0
None
1
2
Odd
Even
Example
#set_serial_parity 0
SERIAL PARITY MODE SET TO NONE
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_stop
108
Commands
#set_serial_stop
Sets the number of stop bits for the serial port. After executing this command, the unit must
be rebooted to apply the changes.
Syntax
#set_serial_stop param1
Parameters
param1
Integer[0 ... 1]
param1
Description (stop bits)
0
1
1
2
Example
#set_serial_stop 0
SERIAL STOP BITS SET TO 1
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_serial_allow
#get_serial_baud
#get_serial_bits
#get_serial_parity
#get_serial_stop
#set_serial_allow
#set_serial_baud
#set_serial_bits
#set_serial_parity
109
Commands
#set_showme
Enables or disables the “Show Me” feature. When the “Show Me” feature is enabled,
then both the Power and Link LED indicators, on the front panel, will flash. This quickly
identifies a unit and is useful when multiple units are being used. The default setting is
disabled.
Syntax
#set_showme param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_showme 1
SHOW ME ENABLED
Related Commands
#get_discovery
#set_discovery
110
Commands
#set_telnet_access
Enables or disables Telnet access. After executing this command, the unit must be rebooted
to apply the changes.
Syntax
#set_telnet_access param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_telnet_access 1
TELNET ACCESS SET TO ENABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_telnet_access
#get_telnet_login
#get_telnet_port
#get_telnet_welcome
#set_telnet_login
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
111
Commands
#set_telnet_login
Enables or disables the Telnet login process. After executing this command, the unit must be
rebooted to apply the changes.
Syntax
#set_telnet_login param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_telnet_login 1
TELNET INTERFACE LOGIN SET TO ENABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_telnet_access
#get_telnet_pass
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_pass
#set_telnet_port
#set_telnet_welcome
112
Commands
#set_telnet_pass
Sets the Telnet password. The password cannot exceed 8 characters in length and is casesensitive. No special characters are allowed. The default password is admin. After executing
this command, the unit must be rebooted to apply the changes.
Syntax
#set_telnet_pass param1
Parameters
param1
String
Example
#set_telnet_pass b055man
TELNET INTERFACE PASSWORD IS SET b055man
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_telnet_access
#get_telnet_pass
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_login
#set_telnet_port
#set_telnet_welcome
113
Commands
#set_telnet_port
Sets the Telnet listening port. After executing this command, the unit must be rebooted to
apply the changes.
Syntax
#set_telnet_port param1
Parameters
param1
Integer[0 ... 65535]
Example
#set_telnet_port 23
TELNET COMMUNICATIONS PORT SET TO PORT 23
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_telnet_access
#get_telnet_pass
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_login
#set_telnet_pass
#set_telnet_welcome
114
Commands
#set_telnet_welcome
Enables / disables the Telnet welcome screen. After executing this command, the unit must
be rebooted to apply the changes.
Syntax
#set_telnet_welcome param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_telnet_welcome Welcome!
TELNET WELCOME SCREEN IS ENABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_telnet_access
#get_telnet_pass
#get_telnet_port
#get_telnet_welcome
#set_telnet_access
#set_telnet_login
#set_telnet_pass
#set_telnet_port
115
Commands
#set_tx_channel
Sets the audio channel for the Sender unit. This command is only available when connected to
the Sender unit.
Syntax
#set_tx_channel param1
Parameters
param1
Integer[0 ... 255]
Example
#set_tx_channel 1
TRANSMITTER CHANNEL SET TO 1
Related Commands
#get_tx_channel
#get_rx_channel
r
116
Commands
#set_udp_access
Enables or disables UDP access. After executing this command, the unit must be rebooted to
apply the changes.
Syntax
#set_udp_access param1
Parameters
param1
Integer[0 ... 1]
param1
Description
0
Disabled
1
Enabled
Example
#set_udp_access 0
UDP ACCESS SET TO DISABLED
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_port
117
Commands
#set_udp_port
Sets the local UDP listening port. After executing this command, the unit must be rebooted to
apply the changes.
Syntax
#set_udp_port param1
Parameters
param1
Integer[0 ... 65535]
Example
#set_udp_port 50007
UDP COMMUNCATION IS SET TO PORT 50007
PLEASE REBOOT THE UNIT TO APPLY CHANGES.
Related Commands
#get_remote_udp_access
#get_remote_udp_ip
#get_remote_udp_port
#get_udp_access
#get_udp_port
#set_remote_udp_access
#set_remote_udp_ip
#set_remote_udp_port
#set_udp_access
118
Commands
#set_web_port
Sets the HTTP listening port.
Syntax
#set_web_port param1
Parameters
param1
Integer[0 ... 65535]
Example
#set_web_port 82
WEB INTERFACE PORT SET TO 80
PLEASE REBOOT THE UNIT TO APPLY CHANGES
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipconfig
#get_netmask
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_netmask
119
Commands
#set_webui_ad_pass
Sets the Administrator password for the Web interface login. The password cannot exceed
eight characters in length. The default password is admin.
Syntax
#set_webui_ad_pass param1
Parameters
param1
Password
Example
#set_webui_ad_pass b05Sman
WEB UI ADMINISTRATOR PASSWORD IS SET
Related Commands
#set_webui_user_pass
120
Commands
#set_webui_user_pass
Sets the User password for the Web interface login. The password cannot exceed eight
characters in length. The default password is user.
Syntax
#set_webui_user_pass param1
Parameters
param1
Password
Example
#set_webui_user_pass m1ni0n
WEB UI USER PASSWORD IS SET
Related Commands
#set_webui_ad_pass
121
Commands
r
Changes a Receiver unit to the specified audio channel. Changing the audio channel allows a
Receiver unit to accept the signal from a Sender unit that uses the same audio channel. This
command is only available when connected to a Receiver unit. Do not precede this command
with the # symbol.
Syntax
r param1
Parameters
param1
Integer[0 ... 255]
Example
r 1
TRANSMITTER 1 ROUTED TO RECEIVER
Related Commands
None
122
Network Cable Diagram
Front of RJ-45 Connector
1 2 3 4 5 6 7 8
Gefen recommends the TIA/EIA-568-B wiring option. Use the table below when
field-terminating cable for use with Gefen products.
Pin
Color
Description
1
Orange / White
TD+ (Transmit Data, positive differential signal)
2
Orange
TD- (Transmit Data, negative differential signal)
3
Green / White
RD+ (Receive Data, positive differential signal)
4
Blue
Unused
5
Blue / White
Unused
6
Green
RD- (Receive Data, negative differential signal)
7
Brown / White
Unused
8
Brown / White
Unused
Note
Shielded CAT-5e (or better) cabling should be used..
123
Rack Tray Installation
The following illustrations provide instructions for installing the Sender and/or Receiver
unit(s) in the Gefen 1U Rack Tray (Gefen part no. EXT-RACK-1U-GRY).
Step 1
Turn unit upside down.
Step 2
Remove rubber feet.
Step 3
Line up holes on unit and rack tray.
Step 4
Install countersink screws .
Step 5
Ensure the unit is installed securely.
Step 6
Unit has been installed into rack tray.
124
Specifications*
Supported Formats
Audio
•
Analog L/R Stereo, 2-Channel PCM, and up
to 5.1 channels of Bitstream
Audio In Connector (Sender)
•
1 x 3.5mm mini-stereo, female
Audio Out Connector (Receiver)
•
1 x 3.5mm mini-stereo, female
Opt In Connector (Sender)
•
1 x TOSLINK®
Opt Out Connector (Receiver)
•
1 x TOSLINK®
Coax In Connector (Sender)
•
1 x RCA-type, female
Coax Out Connector (Receiver)
•
1 x RCA-type, female
Link Connector (Sender / Receiver)
•
1 x RJ-45, shielded
Link PoE Connector (Sender / Receiver)
•
1 x RJ-45, shielded
RS-232 Connector (Sender / Receiver)
•
1 x 3.5mm mini-stereo, female
IR In/Ext Connector (Sender / Receiver)
•
1 x 3.5mm mini-stereo, female
IR Out Connector (Sender / Receiver)
•
1 x 3.5mm mini-stereo, female
Power Connector (Sender / Receiver)
•
1 x 5V DC, locking, 5.5mm barrel/2.1mm pin
Power Indicator (Sender / Receiver)
•
1 x LED, blue
Link Indicator (Sender / Receiver)
•
1 x LED, green
Power Consumption (maximum)
•
Sender: 3W, Receiver: 7W
Operating Temperature
•
+32 to +122°F (0 to +50°C)
Operating Humidity
•
5% to 90% RH, non-condensing
Storage Temperature
•
-4 to +185°F (-20 to +85°C)
Storage Humidity (RH)
•
0% to 95% RH, non-condensing
MTBF
•
50000 hours
Dimensions (W x H x D)
(Sender / Receiver),
not including feet and connectors
•
8.4” x 1.0” x 4.9” (214mm x 25mm x 123mm)
Net Weight (Sender/Receiver)
•
1.6 lbs. (0.72 kg)
Connectors & Indicators
Operational
Physical
* Features and specifications are subject to change without notice.
All trademarks and registered trademarks are properties of their respective owners.
Copyright© 2018 Nortek Security & Control, LLC
125
Nortek Security & Control, LLC
1800 S McDowell Blvd. Petaluma CA 94954, USA
1-707-283-5900 1-800-472-5555
Copyright© 2018 Nortek Security & Control, LLC
Part Number: MAN-EXT-ADA-LAN