Avtec | MWD | Spec sheet | Avtec MWD Spec Sheet

Avtec MWD Spec Sheet
Utility Distribution System
Available for Electrical and
Gas Usage
Utility Raceways M Series model MWD
Description:
The M-series Raceway is a Utility Distribution System
comprised of a stainless steel sheet metal housings enclosing
cable bus electrical system and plumbing services that
provide connections for individual appliances. Raceways with
plumbing services are Listed by Underwriters Laboratories
(UL) as Commercial Appliance Outlet Centers. Raceways
with only electrical services are Listed by UL as Multi-outlet
Assemblies. These raceways are intended primarily for
use behind a cooking battery, or cooking appliance line-up.
Individual Point-of-use connection plates are located near the
top along the length of the raceway.
Peaked Top Shown
Specifications:
Dimensions: Horizontal Chase Width: 6” [generally for plumbing services less than 2” NPT] or 8” [generally for plumbing services 2” NPT or greater], Height: 18” – 30” plus 3-6” peaked top, Length: as required. Service Towers Width: 6-12” Height:
Finished Floor to Exhaust Hood or Finished Ceiling, Length: 18” Nominal to 42” Nominal. Intermediate Pedestals Width: 5-8”
Height: Finished Floor to bottom of Horizontal Chase, Length: 5-8”. Construction: 300-series Stainless Steel. Removable panels
held in place with threaded fasteners. Electrical Data: 30 to 150 amperes. 120/208-240 volts. Single- or three-phase. Water:
150 psig & 140° F (60° C) maximum. Gas (Natural gas or LP): 1.25 psig
Standard Features:
Optional Accessories:
• Point-of-use branch circuit protection • Black iron gas supply line, if required
• Black iron steam supply and
with receptacle or flexible liquid tight
condensate return lines, if required
metal conduit (pigtail) mounted
• Quarter-turn shut-off valves on
adjacent to Point-of-use branch
all individual connections
circuit protection on 4.5x12”
• Quarter-turn shut-off valves on
connection plate. NOTE: For other
main supply valves
voltage configurations, consult
• 2” High collar at top of service
factory.
tower allows ±1/2” vertical
• Ground fault circuit interrupter for
adjustment to compensate for floor
15 & 20 amp, 120/1, straight blade
and/or exhaust hood mounting
receptacles
irregularities
• Cable bus
• Copper hot and cold water supply
lines, if required
Please reference our website for the most
updated product information and specifications.
Avtec Utility Raceways
PP SPEC1046 Rev. A
Revised 11/07
Model MWD
Optional Accessories:
Main electrical service circuit
breaker with shunt trip
Quick-disconnect fittings for individual
gas connections in addition to quarter-turn shut-off valves for movable
appliances
Quick-disconnect fittings for individual
water connections in addition to quarter-turn shut-off valves for movable
appliances
Vent light switch in service tower
Vent light switch with circuit breaker
in service tower
Duplex convenience outlet in service
tower(s)
Gas delay reset (GDRI)
120V AC fire-fuel shut-off solenoid
valve(s) for gas supply. 1 1/2” And
smaller located in service tower(s)
(2” and larger are remotely located)
Temperature/pressure gauge at water
incoming service location
Security package (includes):
• exposed fasteners to be tamper-re-
sistant, pin-in-head torx-head, shipped
loose and installed in field
• hinged doors equipped with eye for
customer-supplied padlock
Panel mounted faucet or pot filler
Flat top in lieu of peaked top on
horizontal chase
Ventilation control panel mounted in
tower
Filtered water system
Front, Top & Side Views
Front, Top & Side Views
Peaked Top Shown
888-994-7636, unifiedbrands.net
© 2018 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.
Was this manual useful for you? yes no