Vulcan K60ELT Service Manual

Add to my manuals
30 Pages

advertisement

Vulcan K60ELT Service Manual | Manualzz

SERVICE MANUAL Electric Stationary and Tilting Kettles

K20EL K40EL K60EL K20ELT K40ELT K60ELT ML-136073 ML-136074 ML-136075 ML-136077 ML-136078 ML-136079 - NOTICE This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

This manual is not intended to be all encompassing. If you have not attended a Vulcan Service School for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained Vulcan Service Technician.

The reproduction, transfer, sale or other use of this Manual, without the express written consent of Vulcan, is prohibited.

This manual has been provided to you by ITW Food Equipment Group LLC ("ITW FEG") without charge and remains the property of ITW FEG, and by accepting this manual you agree that you will return it to ITW FEG promptly upon its request for such return at any time in the future.

A product of Vulcan-Hart 3600 North Point Blvd Baltimore, MD 21222 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles

TABLE OF CONTENTS

SERVICE UPDATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SERVICE UPDATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STATIONARY AND TILTING KETTLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MODELS COVERED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 OPERATION, CLEANING AND MAINTAINENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

REMOVAL AND REPLACEMENT OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 CONTROL BOX COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 BOTTOM COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 COMPONENT PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

HEATING CONTACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 TEMPERATURE CONTROLLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 WATER LEVEL CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

MAIN TRANSFORMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 HEATING ELEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

WATER LEVEL PROBE (LLCO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

TEMPERATURE SENSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 PRESSURE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

POTENTIOMETER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SWITCH ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

GEARBOX (TILT MODELS ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 TILT BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

SERVICE PROCEDURES AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 TEMPERATURE CONTROLLER TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

POTENTIOMETER TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 THERMOCOUPLE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 VENTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

FILLING THE RESERVOIR JACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 PARTIAL REFILL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

COMPLETE DRAINING AND REFILL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

HEATING ELEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 KETTLE TILT ADJUSTMENT (TILT MODELS ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

ELECTRICAL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 COMPONENT FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

COMPONENT LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

WATER LEVEL CONTROL (WLC LLCO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

SCHEMATIC DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

© VULCAN 2017 F45472 Rev. A (1117) Page 2 of 30

Electric Stationary and Tilting Kettles - SERVICE UPDATES

SERVICE UPDATES

SERVICE UPDATES

October 2017

Updated FILLING THE RESERVOIR JACKET

Page 3 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - General

General

INTRODUCTION

General

The procedures in this manual apply to all models unless otherwise specified. The pictures and illustrations are of a model K40ELT kettle unless otherwise noted. All information and specifications contained in this manual are based on the latest product information available at the time of printing.

Stationary and Tilting Kettles

The electric stationary and tilting kettles are self contained two thirds jacketed kettles. The lower two thirds of the kettle bowl is a double wall stainless steel construction that provides a reservoir for a solution of heat transfer fluid and distilled water for improved heating of the kettle contents. The kettles are used to prepare a variety of liquid or semi-liquid food products such as soups, stews and sauces.

MODELS COVERED

Electric Stationary and Tilting Kettles

K20EL Stationary Kettle - 20 Gallon K40EL Stationary Kettle - 40 Gallon K60EL Stationary Kettle - 60 Gallon K20ELT Tilting Kettle - 20 Gallon K40ELT Tilting Kettle - 40 Gallon K60ELT Tilting Kettle - 60 Gallon

CONTROL PANEL

Fig. 1

TOOLS

• • •

Standard

Standard set of hand tools.

Pipe thread sealant.

VOM with an AC current tester (meter sensitivity should be at least 20,000 ohms per volt).

• • Temperature meter (thermocouple type). Use for checking kettle temperature.

6 gallon container to hold drained reservoir jacket fluid.

• • •

Special

Torque wrench (ft-lbs) for tightening heating element mounting bolts.

Dowfrost heat transfer fluid Part No. 558038 (5 gallon). Refer to service procedures for volumes.

Water - Use only distilled water only for re-filling of the jacket (purchase locally).

F45472 Rev. A (1117) Page 4 of 30

Electric Stationary and Tilting Kettles - General

SPECIFICATIONS

Reservoir Jacket Fluid

Water - Use only distilled water for partial re-filling of the jacket (purchase locally).

• Dowfrost heat transfer fluid Part No. 558038 (5 gallon). Use during a complete re-fill of the jacket with new fluid. Refer to service procedures for volumes.

MODEL KW

12

PHASE

1 3

ELECTRICAL SPECIFICATIONS Amperage per Line 208V

57.7

33.3

240V

-- ---

480V

-- 14.4

Minimum Circuit Ampacity 208V 240V 480V

75 45 -- -- -- 20 K20EL/ELT 16 1 3 -- -- 66.7

38.5

-- -- -- -- 85 50 -- -- K40EL/ELT 18 3 50.0

43.3

21.7

65 55 30 K60EL/ELT K40EL/ELT 24 3 66.6

57.7

28.9

85 75 40 K60EL/ELT The 208/240V electric kettles are wired from the factory for a 208V 3-phase supply. If connecting to 240V 3-phase supply, the primary voltage tap on the transformer must be changed to this voltage. For connecting to a single

phase supply, the wiring between terminal block and contactors must be changed as shown in the WIRING DIAGRAMS.

OPERATION, CLEANING AND MAINTAINENCE

• • Refer to F35457 Installation & Operation Manual for specific instructions. The manual includes: A page from the Stainless Steel Care and Cleaning Guide for proper care and cleaning of stainless steel.

Draw-Off Valve and Plug Valve dissassembly & cleaning instructions.

Page 5 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

REMOVAL AND REPLACEMENT OF PARTS

CONTROL BOX COVER COMPONENT PANELS

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

The following pictures show the Stationary Kettle, the

Tilting Kettle and the Bottom component panels. Use

these pictures to asist in removal and replacement of the components in these kettles.

Control Box Cover

BOTTOM COVER

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Stationary Kettle Bottom Cover

F45472 Rev. A (1117) Page 6 of 30

Tilting Kettle

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

TEMPERATURE CONTROLLER

1.

2.

3.

4.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Disconnect lead wires from temperature controller.

Remove screws securing the temperature controller to panel.

Reverse procedure to install and check for proper operation.

Bottom

HEATING CONTACTORS

1.

2.

3.

4.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Note location of lead wires then disconnect the wires from contactor being replaced.

Remove screws securing the contactor to panel.

Reverse procedure to install and check for proper operation.

Fig. 8

WATER LEVEL CONTROL

Fig. 7

1.

2.

3.

4.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Disconnect lead wires from the water level control.

Remove screws securing the water level control to panel.

Reverse procedure to install and check for proper operation.

Page 7 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

Fig. 9

MAIN TRANSFORMER

Fig. 10

HEATING ELEMENT

1.

2.

3.

4.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Disconnect lead wires from the transformer.

Remove screws securing the transformer to panel.

Reverse procedure to install and check for proper operation.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

TILTING KETTLE

1.

2.

3.

Open pressure relief valve until reservoir jacket is completely vented.

Remove BOTTOM COVER.

4.

Remove wire from water level probe (LLCO).

Place a large container under the kettle. Remove water level probe (LLCO) and open the fill valve (40 & 60 gallon kettles) or remove pipe plug from fill elbow (20 gallon kettles) to vent the jacket and drain liquid from kettle.

F45472 Rev. A (1117) Page 8 of 30

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

Fig. 11 NOTE:

If liquid drained from kettle is still clean, save for reuse.

5.

Remove heater access cover.

8.

9.

Fig. 13

Remove heating element from kettle.

Reverse procedure to install. Use a new heating element seal whenever installing heating element. Torque mounting nuts to 40 ft-lbs and tighten in an alternating pattern.

10. Refill jacket with fluid. See FILLING THE RESERVOIR JACKET.

11. Remove air from reservoir jacket as outlined

under VENTING.

12. Check for proper operation and leaks around heating element.

STATIONARY KETTLE

1.

Open pressure relief valve until reservoir jacket is completely vented.

2.

3.

4.

Remove BOTTOM COVER.

Remove wire from Water Level Probe (LLCO).

Place a large container under the kettle. Remove water level probe (LLCO) and open the fill valve (40 & 60 gallon kettles) or remove pipe plug from fill elbow (20 gallon kettles) to vent the jacket and drain liquid from kettle.

6.

7.

Fig. 12

Note lead wire locations and disconnect wires from heating element.

Remove mounting bolts securing heating element to kettle.

Page 9 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

10. Refill jacket with fluid. See FILLING THE RESERVOIR JACKET.

11. Remove air from reservoir jacket as outlined

under VENTING.

12. Check for proper operation and leaks around heating element.

WATER LEVEL PROBE (LLCO)

Fig. 14 NOTE:

If liquid drained from kettle is still clean, save for reuse.

5.

6.

Remove CONTROL BOX COVER.

Note lead wire locations and disconnect wires from heating element.

7.

Remove mounting nuts securing heating element to kettle.

1.

2.

3.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Open pressure relief valve until reservoir jacket is completely vented.

Remove BOTTOM COVER.

Disconnect lead wires from the water level probe .

8.

9.

Fig. 15

Remove heating element from kettle.

Reverse procedure to install. Use a new heating element seal whenever installing heating element. Torque mounting bolts to 40 ft-lbs and tighten in an alternating pattern.

F45472 Rev. A (1117) Page 10 of 30 4.

Fig. 16

Place a large container under kettle to catch liquid that drains from kettle.

NOTE:

If liquid drained from kettle is still clean, save for reuse.

5.

Remove component from bottom of kettle.

6.

Reverse procedure to install.

NOTE:

Clean threads and apply pipe thread sealant when replacing water level probe.

7.

Refill jacket with fluid. See FILLING THE RESERVOIR JACKET.

8.

9.

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS Remove air from reservoir jacket as outlined

under VENTING.

Check for proper operation.

TEMPERATURE SENSOR

8.

Check for proper operation.

PRESSURE SWITCH

1.

2.

3.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Open pressure relief valve until reservoir jacket is completely vented.

Remove BOTTOM COVER.

Place a large container under the kettle to catch liquid that drains from kettle.

NOTE:

If liquid drained from kettle is still clean, save for reuse.

4.

Remove component from bottom of kettle.

1.

2.

3.

4.

Place a large container under the kettle to catch liquid that drains from kettle.

NOTE:

If liquid drained from kettle is still clean, save for reuse.

5.

6.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Open pressure relief valve until reservoir jacket is completely vented.

Remove BOTTOM COVER.

Disconnect lead wires from the pressure switch.

Disconnect compression fitting from elbow near the pressure switch.

Remove top nut on brass fitting to remove pressure switch from mounting bracket.

7.

Remove component from bottom of kettle.

5.

Fig. 17

Reverse procedure to install.

NOTE:

Clean threads and apply pipe thread sealant when replacing temperature sensor.

6.

7.

Refill jacket with fluid. See FILLING THE RESERVOIR JACKET.

Remove air from reservoir jacket as outlined

under VENTING.

Page 11 of 30 8.

Fig. 18

Reverse procedure to install.

NOTE:

Pressure switch setting is fixed and should not be adjusted. Clean threads and apply pipe thread sealant when replacing pressure switch.

F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS 9.

Refill jacket with fluid. See FILLING THE RESERVOIR JACKET.

10. Remove air from reservoir jacket as outlined

under VENTING.

11. Check for proper operation.

POTENTIOMETER

1.

2.

3.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Disconnect potentiometer wire from temperature control.

Pull temperature dial from potentiometer shaft and remove seal nut.

Fig. 20

SWITCH ASSEMBLY

1.

2.

3.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Remove CONTROL BOX COVER.

Note lead wire location and disconnect wires from switch.

Press down on tabs to free switch from housing.

4.

5.

Fig. 19

Remove potentiometer from control panel.

Reverse procedure to install and check for proper operation.

NOTE:

When installing, ensure potentiometer alignment tab is seated in positioning bracket.

F45472 Rev. A (1117) 4.

Page 12 of 30

Fig. 21

Reverse procedure to install.

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS

GEARBOX (TILT MODELS ONLY)

1.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Place a pallet jack under the kettle of the unit.

NOTE:

Place pallet jack under kettle and not under the tubular frame.

NOTE:

Place 2x4 or 4x4s on the pallet jack if needed to reach the bottom of the kettle.

2.

Remove CONTROL BOX COVER.

3.

Note location of wiring and remove element, pressure switch wires and unplug the sensor plug.

7.

8.

Fig. 23

Install new gearbox in kettle.

Lower the gearbox until it touches component box housing.

NOTE:

Only lower the gearbox enough to align the holes and bolt the gearbox down.

9.

Lower the kettle and remove pallet jack.

10. Connect the wiring.

11. Check operation of kettle.

TILT BEARING

4.

Fig. 22

Remove the four bolts holding the gearbox to the component box.

5.

Lift the kettle just high enough to slide the gearbox off of the shaft and clear the component box lip.

NOTE:

Be careful not to damage the wiring as you remove gearbox from shaft.

6.

Remove the positive stop plate assembly from the old gearbox and install it on the new one.

1.

Disconnect the electrical power to the machine and follow lockout / tagout procedures.

Place pallet jack under kettle.

NOTE:

Make sure pallet jack is under kettle and not under the tubular frame.

NOTE:

Place 2x4 or 4x4s on the pallet jack if needed to obtain the proper height.

2.

Loosen set screws on bearing assembly.

Page 13 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS 3.

4.

5.

Fig. 24

Lift kettle high enough to pull bearing assembly off of stand.

Slide bearing assembly off of kettle shaft.

Reverse procedure to install new bearing assembly.

F45472 Rev. A (1117) Page 14 of 30

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS

SERVICE PROCEDURES AND ADJUSTMENTS

Certain procedures in this section require electrical test or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power and follow lockout / tagout procedures, attach test equipment and reapply power to the test.

1.

2.

3.

4.

5.

6.

7.

8.

TEMPERATURE CONTROLLER

Place kettle in full upright position. (tilt kettles only) Set temperature dial to lowest setting. Kettle must be below 110°F before verifying the potentiometer output to the controller is good over the full range of temperature dial travel.

Access TEMPERATURE CONTROLLER.

Check all lead wires for secure connections to the controller terminals. Wiring harness lead wires must be connected to T1-T2 and T3-T4 for proper input to controller.

TEST

Fig. 25

Re-connect power to the machine.

Turn power switch on.

Verify temperature controller is receiving 120VAC at terminals T1-T3 and T2-T4 and machine is properly grounded.

Slowly turn temperature dial to the highest setting and monitor heat light over the full range of travel.

A.

B.

Verify heat light (amber) comes on and heating element is energized.

If heat light does not remain on or flashes momentarily as temperature setting is slowly increased, verify condition of potentiometer as outlined under

POTENTIOMETER TEST.

NOTE:

Temperature controller will de-energize internal relay and turn off the output status LED if the circuitry detects an open thermocouple. LED will begin to flash 3 times, pause, then repeat the flash sequence to indicate the open thermocouple condition.

C.

If heat light and heating element do not turn on.

1) 2) Verify condition of thermocouple as

outlined under THERMOCOUPLE TEST.

Verify output from terminal T8 on controller as outlined in the steps below.

9.

Disconnect lead wire from terminal T7 on the controller.

A.

Verify 120VAC between lead wire from T7 and X1 on the output of main transformer. If correct, re-connect lead wire to terminal T7 and continue with procedure.

B.

If incorrect, check pressure switch (1PS) and water level controller (WLC LLCO).

10. Verify 120VAC between T8 and X1 on the output of main transformer. If correct, output from controller is functioning properly.

A.

If incorrect, install a replacement temperature controller and check for proper operation.

Page 15 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS

POTENTIOMETER TEST THERMOCOUPLE TEST

1.

2.

3.

4.

5.

Fig. 26

Remove POTENTIOMETER.

Turn potentiometer shaft fully counterclockwise to the lowest setting.

Set VOM to measure resistance.

Connect meter leads to the white and black lead wires on potentiometer terminals.

A.

Resistance should measure approximately zero ohms.

Slowly turn potentiometer shaft clockwise over the full range of travel and monitor resistance change on the meter.

A.

Resistance should measure 800 to 1200 ohms with shaft turned fully clockwise.

B.

C.

If the resistance value increased smoothly without sudden drops or spikes and the full travel resistance value is within tolerance then potentiometer is functioning properly.

If the resistance value did not increase smoothly but had drops or spikes over the full travel range then potentiometer is not functioning properly. Install a replacement potentiometer and check for proper operation.

1.

2.

3.

Fig. 27

Access TEMPERATURE CONTROLLER.

Remove thermocouple lead wires from temperature controller.

Check thermocouple for a measurable resistance (approximately 5 to 10 ohms at room temperature). If meter reads an overload (OL) condition (open), or zero ohms (short) replace the thermocouple and check temperature controller for proper operation.

VENTING

NOTE:

This procedure outlines venting the reservoir jacket to remove air for proper heat transfer to the kettle contents.

F45472 Rev. A (1117) Page 16 of 30

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS

FILLING THE RESERVOIR JACKET

NOTE:

only).

The reservoir water level must be maintained high enough to submerge the heating element. If low water light comes on during use, the level may be below water level probe (LLCO) and must be replenished before heating can continue. The low water light will come on when kettle is tilted (tilt models 1.

2.

3.

4.

5.

6.

7.

Fig. 28

With the kettle at room temperature, verify pressure gauge is in the vacuum zone and reading 25 to 30 in. Hg.

A.

If vacuum is below minimum listed, air must be removed from reservoir jacket. Continue with procedure to vent as necessary.

Place kettle in full upright position.

Turn power switch on.

Set temperature dial to highest setting. Allow kettle to heat until the heat indicator light turns off.

Open pressure relief valve for approximately 10 seconds.

Turn power switch off and allow kettle to cool (room temperature).

Verify pressure gauge reading is within the correct vacuum range.

A.

If reading is below minimum listed or will not maintain proper vacuum, check all threaded fittings extending from the kettle couplings (right and rear) for leaks and tightness.

1) 2) Check pressure relief valve for leaks from poor valve seating or built up debris. Manually operate the valve several times to reseat. Repeat venting procedure.

If pressure relief valve is malfunctioning, install a replacement and check for proper operation.

Page 17 of 30 When filling reservoir jacket, use only distilled water and heat transfer fluid. The ratio is 75% distilled water and the 25% heat transfer fluid.

Partial Refill

1.

2.

Place kettle in full upright position. (tilt kettle only) Turn power switch on. If low water light is on, continue with procedure.

3.

4.

5.

Set temperature dial to lowest setting.

Open pressure relief valve until reservoir jacket is completely vented.

Remove 1/2" pipe plug from the reservoir jacket fill elbow at back of kettle. Open fill valve. (40 and 60 gallon kettles only)

K40EL/K40ELT and K60EL/K60ELT

F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS

Complete Draining and Refill Disconnect the electrical power to the machine and follow lockout / tagout procedures.

NOTE:

Appearance of fluid will no longer be clear after usage in kettle.

1.

2.

Disconnect power supply and set temperature dial to lowest setting.

Open pressure relief valve until reservoir jacket is completely vented.

A.

B.

C.

K20ELT, K20ELT

Insert funnel into the opening and slowly add a mixture of water and heat transfer fluid until low water light turns off (LLCO probe is satisfied).

Set the thermostat and power switch to OFF position.

Continue adding a mixture of water and heat transfer fluid to bring fluid to the proper operating level per the amount listed in table below.

3.

4.

5.

6.

NOTE:

Clean threads and apply sealant before reinstalling pipe fittings.

7.

8.

Remove BOTTOM COVER.

Place a large container under kettle to catch liquid.

Remove WATER LEVEL PROBE (LLCO).

Remove 1/2" pipe plug from reservoir jacket fill elbow (rear of kettle) to facilitate draining and provide opening for re-fill. (Open fill valve on 40 and 60 gallon kettles) Re-install water level probe.

To Refill.

A.

Remove pressure gauge to allow reservoir jacket to vent during fill procedure.

6.

7.

8.

9.

Model

K20EL / K20ELT K40EL / K40ELT K60EL / K60ELT F45472 Rev. A (1117)

Add Fluid for Proper Operating Level (Qt)

2.25

2.50

3.125

Clean pipe plug threads and apply thread sealant. Install pipe plug and tighten to prevent leaks. Close fill valve. (40 and 60 gallon kettles only) Turn power switch on and verify low water light is off. If low water light is on, there may be a problem with the water level control circuit. See troubleshooting.

Remove air from reservoir jacket as outlined

under VENTING.

Check kettle for proper operation.

B.

Insert funnel into the reservoir jacket fill elbow. Slowly fill the jacket according to the volumes listed in the table below.

RESERVOIR JACKET VOLUME

Model Total Fluid Volume (Qt) Water (Qt) Heat Transfer Fluid (Qt) K20EL/ K20ELT K40EL/ K40ELT K60EL/ K60ELT 12.0

18.0

21.0

8.0

12.0

14.0

4.0

6.0

7.0

9.

Install pipe plug and pressure gauge. Tighten to prevent leaks.

10. Reapply power and turn power switch on and verify low water light is off. If low water light is on, there may be a problem with the water level control circuit. See troubleshooting.

11. Remove air from reservoir jacket as outlined

under VENTING.

Page 18 of 30

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS 12. Check kettle for proper operation and leaks.

13. Install covers.

1.

2.

Access HEATING ELEMENT.

Measure voltage at heating element terminals and verify it against the data plate voltage.

A.

If voltage is incorrect, find the source of the problem.

MODEL

HEATING ELEMENT

K20EL/K20ELT K40EL/K40ELT

VOLTAGE

208 240 480 208 240

KW PER ELEMENT

4 16 12 6 6 K60EL/K60ELT 480 208 240 480 6 8 8 8

NOTE:

Values in table are nominal. Tolerance is ±10 %.

KETTLE TILT ADJUSTMENT (TILT MODELS ONLY)

NOTE:

Perform this procedure whenever the kettle is not returning to a horizontal position when upright, or when kettle is not tilting past 90° to empty contents.

1.

With kettle fully upright, the top of kettle should be horizontal when viewed from either side.

2.

3.

Turn crank handle clockwise to tilt the kettle until it stops. Kettle should be tilted past 90° to allow contents to drain.

If adjustment is necessary, continue with procedure.

4.

5.

Remove CONTROL BOX COVER.

Return kettle to fully upright position.

A.

B.

The inner jam nut should be in solid contact with positive stop traveller.

To adjust upright position (horizontal): 3.

If voltage is correct, check current draw (amps) through the heating element lead wires. If current draw is correct then heating element is ok. See table below for proper values.

NOTE:

Checking current draw is the preferred method over a resistance check when an amp clamp meter is available.

4.

A.

If current draw is not correct then, replace heating element.

Check for proper operation.

C.

CURRENT PER ELEMENT

19.2

22.2

14.4

28.8

25.0

21.7

38.5

33.3

28.9

RESISTANCE PER ELEMENT (OHMS)

10.8

10.8

19.2

7.2

9.6

12.8

5.4

7.2

6.0

1) 2) Loosen outer jam nut 2 to 3 turns counterclockwise and turn the inner jam nut in the same direction and amount.

Turn crank handle to position the top of kettle horizontally.

3) Turn inner jam nut clockwise until it stops against the positive stop traveller. Tighten outer jam nut to secure the stop position.

Turn crank handle to verify operation.

Repeat adjustment as necessary.

Page 19 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - SERVICE PROCEDURES AND ADJUSTMENTS 7.

5) 6) Adjust position of positive stop traveller as needed to align the shoulder screw mounting hole to the threaded hole in stop plate. Install shoulder screw.

Turn crank handle to verify operation.

Repeat adjustment as necessary.

7) Install tilt switch bracket.

Install control panel cover.

Kettle Fully Upright - Traveller Contacts Inner Jam Nut

6.

Fully tilt the kettle until crank handle stops.

A.

B.

Verify positive stop traveller is in solid contact with stop plate.

To adjust fully tilted position: 1) 2) Remove shoulder screw from stop plate.

Remove tilt switch bracket from stop plate.

Kettle Fully Tilted - Traveller Contacts Stop Plate

3) Turn crank handle clockwise to tilt the kettle and empty its contents. Kettle should be tilted approximately 95° to 100°.

4) Turn positive stop traveller on the positive stop shaft (threaded) until it contacts the stop plate.

F45472 Rev. A (1117) Page 20 of 30

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

ELECTRICAL OPERATION

COMPONENT FUNCTION

Water Level Control (WLC LLCO) . . . . . . . . . .

Probe, Water Level (LLCO) . . . . . . . . . . . . . . . .

Contactor (1CON) Limiting . . . . . . . . . . . . . . .

Contactor (2CON) Regulating . . . . . . . . . . . .

Element, Heating . . . . .

Fuse, (1FU & 2FU) . . . .

Switch (1PAS), Pressure . . . . . . . . . . . . . .

Transformer (1T), Main . . . . . . . . . . . . . . . . . .

Switch (1S), Power . . .

Temperature Controller . . . . . . . . . . . . .

Lamp (1LT), Power . . .

Lamp (2LT), Low Water . . . . . . . . . . . . . . . . .

Lamp (3LT), Heat . . . . .

Low water level control. Monitors condition of the WLC LLCO water level probe. Protects kettle from a low water condition in the reservoir jacket and removes power from heating circuit when kettle is tilted.

Low Level Cut-Off (LLCO) probe connected to WLC (LLCO). Controls power to heating circuit.

Connects one side of heating element to power. Energized whenever WLC (LLCO) coil is energized (WLC LLCO contacts closed).

Connects heating element to power. On constantly when temperature controller is calling for heat (temperature controller contacts closed).

Heats reservoir jacket fluid. The heat in the fluid is then transferred to kettle.

Slow blow 3A fuse. Located on primary side of main transformer (1T). Protects control circuitry from over-currents.

Pressure cut-out protection for the reservoir jacket. Range is between 38 to 42 PSI.

Removes power from control circuit if pressure in the jacket rises above switch setting.

Step down transformer from line voltage to 120VAC control circuit voltage.

Controls 120VAC to kettle control circuit Cycles power to regulating contactor (2CON) to maintain the set point temperature. An external set point potentiometer is used for temperature adjustments.

Amber (AM) colored lamp. On when power switch is on.

Red (RD) colored lamp. On when water level in the reservoir jacket drops below water level (LLCO) probe or when kettle is tilted (tilting models only).

Amber (AM) colored lamp. On when temperature controller is calling for heat.

Page 21 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

COMPONENT LOCATION

STATIONARY KETTLE COMPONENTS

F45472 Rev. A (1117) Page 22 of 30

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

TILTING KETTLE COMPONENTS STATIONARY AND TILTING KETTLE BOTTOM COMPONENTS

WATER LEVEL CONTROL (WLC LLCO)

level in the kettle reservoir jacket drops below the WLC LLCO probe. A single low level cut-off probe (LLCO) is connected to the control.

The water level control provides low level cut-off protection to shut off the heat source in case the fluid The water level control has input voltage of 120VAC across terminals L1 and L2 which powers the primary side of the transformer on the board. One side of the Page 23 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION transformer secondary is powered through a series path to chassis ground. The other side of the transformer secondary (12VAC) is connected to the LLCO coil and the LLCO LED. The grounded potential is carried through the water in the reservoir jacket to the LLCO probe. When the kettle is in the full upright position and the reservoir jacket fluid is at the proper level, the fluid is in constant contact with the LLCO probe and the circuit is completed.

When the power switch is turned ON, power is supplied to the water level control. With the kettle in the full upright position and the fluid level in the reservoir jacket in contact with the LLCO probe, the LLCO relay coil is energized. The LLCO relay contacts WLC LLCO-NC open, WLC LLCO-NO close and the LLCO LED turns on. When the kettle is tilted to empty the contents, the fluid is no longer in contact with the LLCO probe and the circuit is open. The LLCO relay coil is de-energized and LLCO LED turns off.

F45472 Rev. A (1117)

Fig. 36 Fig. 37

SEQUENCE OF OPERATION

1.

2.

3.

Conditions.

A.

Kettle connected to correct voltage supply and is properly grounded.

B.

1) 120VAC potential across X2 and X1 on secondary of main transformer.

Power switch and light (1LT) (amber) are off.

C.

D.

E.

Low water light (2LT) (red) is off.

Pressure switch (1PAS) contacts closed.

Temperature dial at lowest setting (potentiometer fully CCW).

1) Internal relay contacts N.O. are open.

F.

Kettle at room temperature and in the full upright position.

Power switch turned ON.

A.

B.

Power light (1LT) (amber) comes on.

Power from secondary of main transformer to control circuit thru pressure switch (1PAS) N.C. contacts.

Water level control (WLC) energized.

A.

WLC LLCO probe satisfied (fluid in kettle reservoir jacket at proper level).

Page 24 of 30

4.

5.

B.

C.

A.

A.

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION 1) LLCO LED comes on.

WLC LLCO N.C. contacts open. Low water light (2LT) (red) remains off.

WLC LLCO N.O. contacts close.

1) Limiting contactor (1CON) energized (power to one side of heating elements).

2) Power to temperature controller.

Set the temperature dial to call for heat (warm/ simmer/boil).

120VAC output from T8 on temperature controller.

1) 2) Heat light (3LT) (amber) comes on.

Regulating contactor (2CON) energized and heating elements are powered.

Kettle reaches set point temperature.

Voltage output removed from T8 on temperature controller.

1) Heat light (3LT) (amber) goes out.

6.

7.

8.

2) Regulating contactor (2CON) de energized and powered is removed from heating elements.

Kettle heat cycles with the temperature controller.

Kettle tilted to empty contents.

A.

WLC LLCO probe no longer satisfied (fluid in kettle reservoir jacket not in contact with probe). Water level control (WLC) LLCO relay de-energized.

B.

1) LLCO LED turns off.

WLC (LLCO) N.C. contacts close and low water light (2LT) (red) comes on.

C.

WLC (LLCO) N.O. contacts open and power is removed from heating circuit.

Kettle returned to upright position. Water level control (WLC) circuit returns to normal operation and heating cycle resumes. Kettle heating will continue to cycle with the temperature controller until the temperature dial is turned fully CCW or power switch is turned OFF.

Page 25 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

SCHEMATIC DIAGRAM

F45472 Rev. A (1117)

Fig. 38

Page 26 of 30

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

WIRING DIAGRAMS

Fig. 39

Page 27 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION F45472 Rev. A (1117)

Fig. 40

Page 28 of 30

Electric Stationary and Tilting Kettles - ELECTRICAL OPERATION

Fig. 41

Page 29 of 30 F45472 Rev. A (1117)

Electric Stationary and Tilting Kettles - TROUBLESHOOTING

TROUBLESHOOTING

TROUBLESHOOTING

SYMPTOM POSSIBLE CAUSES

1.

Kettle does not heat, power light is lit, heat light is lit, low water light is not lit.

2.

3.

Limiting contactor (1CON) malfunction.

Regulating contactor (2CON) malfunction.

Heating element malfunction.

1.

Fluid level in reservoir jacket below water level probe (LLCO).

Kettle does not heat, power light is lit, low water light is lit, heat light is not lit.

Kettle does not heat, power light is lit, low water light is not lit, heat light is not lit.

2.

3.

1.

2.

Water level probe (LLCO) wiring connection malfunction; or probe coated (not sensing fluid); or probe malfunction.

Water level control malfunction.

Pressure switch (1PAS) malfunction.

Temperature sensor malfunction; potentiometer malfunction or temperature controller malfunction.

Kettle does not heat, power light is not lit.

3.

1.

2.

3.

4.

5.

1.

Interconnecting wiring malfunction.

Main circuit breaker off; or control circuit fuse F1 or F2 open.

Supply voltage incorrect.

Main transformer (1T) malfunction.

Power switch off or malfunction.

Interconnecting wiring malfunction.

No vacuum in reservoir jacket when kettle is cold.

Kettle heats up slow or will not boil product.

2.

3.

4.

Supply voltage incorrect.

Heating element malfunction.

Temperature sensor malfunction; or potentiometer malfunction; or temperature controller malfunction.

F45472 Rev. A (1117) Page 30 of 30