Cooper Lighting 0-10V Preset Slide Dimmer Installation Instruction
Add to my manuals2 Pages
Cooper Lighting 0-10V Preset Slide Dimmer provides smooth dimming for LED fixtures, electronic ballasts, and dimmable power supplies. It features a slider control for precise light adjustment and a maximum light level trim adjustment to set the desired brightness range. This dimmer is compatible with Advance Transformer Mark 7, OSRAM Sylvania Quicktronic Helios, and equivalent dimmable ballasts. It also works with Eaton's SP20-RD4 switchpack for additional switching capacity.
advertisement
▼
Scroll to page 2
Fluorescent and LED Fixture Slide Dimmer Single Pole (One location) or 3-Way (Multi-location) Cat. No. WBSD-010M-C1 1200VA-120VAC, 60Hz, 1500VA-277VAC, 60Hz 10A LED, 120VAC/277VAC, 60Hz 10A Electronic Ballast, 120VAC/277VAC, 60 Hz 28mA Maximum Sink Current For Use with LED fixtures using 0-10V dimmable power supply/drivers, Advance Transformer Mark 7® OSRAM Sylvania Quicktronic® Helios™ or equivalent dimmable ballasts. DI-420-IP710-02A INSTALLATION INSTRUCTIONS WARNING: CAUTIONS: • T O AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING OR SERVICING FIXTURE! • • • • CAUTIONS: • To avoid overheating and possible damage to this device and other equipment, use only with the appropriate LED 0-10V dimmable power supplies/ drivers, Advance Transformer 120/277V Mark 7® 0-10V ballasts or OSRAM Sylvania Quicktronic® Helios™ electronic ballasts. Tools needed to install your Dimmer Note: No derating is required in this mult-device installation as referenced in the following chart. Slotted/Philips Screwdriver Electrical Tape Pliers PencilCuttersRuler Changing the color of your Dimmer Your Dimmer includes three color options. The Dimmer ships with the White frame attached. To change color of frame, proceed as follows: Volts Single Two Gang More than 2 Devices WBSD-010M-C1 120 1200VA 1200VA 1200VA WBSD-010M-C1 277 1500VA 1500VA 1500VA Line up tabs and press in side to attach Note: Move slider on dimmer and slider on change kit to bottom of the slide bar prior to engaging. Installing Dimmer by itself or with other devices If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows: MULTI-DEVICE APPLICATION: NOTE: You only need to remove side sections if installing with other dimmers or if it does not fit in wall box – not when installing with mechanical switches. When installing more than one dimmer in the same location, the side sections of the mounting strap must be removed. Use pliers to carefully bend side sections back and forth until they break off. Remove all inner side sections (most common): NOTE: If the wiring in the wall box does not resemble any of these configurations, consult an electrician. MAXIMUM BULB WATTAGE: 3 0-10VDC ballasts are rated in Volt-Amps (VA). The maximum number of ballast per dimmer is based on the load VA rating. The maximum bulb wattage is determined by the efficiency of the ballast. 1 1 SP20-RD4 SWITCH RATINGS: 20 Amps for 120 and 277 VAC Ballast 0-10 VDC Sink Current Rating: 28 mA maximum sink current. Contact your ballast manufacturer for the sink current rating of the ballast. INSTALLING YOUR DIMMER Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Step 4B 3-Way Wiring Application: This wire is used in 3-way installations only. For single pole installations, do not remove this insulating label. Violet Neutral Gray Insert wires straight then twist clockwise 3-Way 1. Load (See note below) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color 6. Gray (-) 7. Violet (+) IMPORTANT: For 3-way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and the standard 3-way switch wall box.The remaining two wires on the brass or lighter screws screw terminatls of the old switch are the travelers. Step 3 • Pull off pre-cut insulation from Dimmer leads. • Make sure that the ends of the wires from the wall box are straight (cut if necessary). • Remove 5/8" (1.6 cm) of insulation from each wire in the wall box (shown). • For Single-Pole Application, go to Step 4A. • For 3-Way Application, go to Step 4B. Cut (if necessary) Black Red Black Red Electrical Tape 5/8" (1.6 cm) Strip Gage Electrical Tape Connect wires per WIRING DIAGRAM 1 (shown on page 2) as follows: Connect wires per WIRING DIAGRAM 3 (shown on page 2) as follows: Screw wire nuts on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape. Screw wire nuts on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape. NOTE: Ensure that low-voltage wiring (for Gray and Violet connection of dimmer) is installed at wallbox that will house the WBSD-010M-C1 dimmer. NOTE: For additional switching capacity, use dimmers in conjuction with an Eaton SP20-RD4 switchpack. Preparing wires: Strip 5/8" (1.6 cm) Gray Insert wires straight then twist clockwise Red 5 Single Pole 1. Load 2. Neutral 3. Ground 4. Line (Hot) 5. Gray (-) 6. Violet (+) Neutral Ground Ground 4 Violet Green Green 4 Do not remove outer side sections Bend back and forth to remove side section 2 NOTE: Ensure that low-voltage wiring (for Gray and Violet connection of dimmer) is installed at wallbox that will house the WBSD-010M-C1 dimmer. OFF Single-Pole Wiring Application: Red 6 2 3 For applications using Eaton's SP20-RD4 switchpack (Shown in Wiring Diagrams 2), the SP20-RD4 switch ratings are as follows (refer to SP20-RD4 Instruction Sheet for additional information): Step 4A 7 6 5 NOTE: For additional switching capacity, use dimmers in conjuction with an Eaton SP20-RD4 switchpack. Push in side at tab to release NOTE: Use only one (1) dimmer in a 3- or 4-way circuit. The switch(es) will turn the light on at the brightness level selected at the dimmer. Step 2 Identifying your wiring application MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE Cat. No. To be installed and/or used in accordance with appropriate electrical codes and regulations. If you are unsure about any part of these instructions, consult an electrician. Lighting fixture and dimmer must be grounded. Use this device only with copper or copper clad wire. • Green dimmer Ground lead to Green or bare copper wire in wall box. • Black dimmer lead to Line Hot wall box wire. • Red dimmer lead without insulating label to Load wall box wire. • Remaining Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Red lead, use a small wire nut or electrical tape to cap off. • V iolet dimmer lead to (+) Violet connection on ballast. • G ray dimmer lead to (-) Gray connection on ballast. • Proceed to Step 5. NOTE: Dimmer can be installed on either the Load or Line side. NOTE: Ensure that low-voltage wiring (for Gray and Violet connection of dimmer) is installed at wallbox that will house the WBSD-010M-C1 dimmer. NOTE: For additional switching capacity, use dimmers in conjuction with an Eaton SP20-RD4 120/277V switchpack. • Green dimmer Ground lead to Green or bare copper wire in wall box. • B lack dimmer lead to tagged (common) wall box wire identified in step 2. • R emove Red insulating label from Red lead. • F irst Traveler wall box wire identified in step 2 to any red dimmer lead. • S econd Traveler wall box wire identified in step 2 to the remaining red dimmer lead. • V iolet dimmer lead to (+) Violet connection on ballast. • G ray dimmer lead to (-) Gray connection on ballast. • Proceed to Step 5. Step 5 Testing your Dimmer prior to mounting in wall box: • Restore power at circuit breaker or fuse. • Carefully holding Dimmer as shown, move slider control lever to highest position. Lights should turn ON to brightest level. If lights do not turn ON, depress push-button switch once. Lights should turn ON to brightest level. If lights still do not turn ON, refer to the TROUBLESHOOTING section. OPERATION NOTE: If using the dimmer in a 3-way application, the lights will turn ON at brightness set on dimmer's slide control lever. The lights can be controlled from either the dimmer or the switch location. ON/OFF: Depress push-button switch to ON position - Lights will turn ON. Dimmer Depress push-button switch to OFF position - Lights will turn OFF. Hot (Black) BRIGHTEN & DIM: Move slider control lever Lights will BRIGHTEN or DIM. Line 120/277VAC, 60Hz Dimmer Mounting: Black Violet Gray Red Red To Lamps Insulating Label Black This dimmer features a Maximum Trim adjustment to adjust the maximum light level of the dimmer. Yellow Yellow/Orange 2. Rotate the dial clockwise to reduce the maximum light level, or counter-clockwise to increase the maximum light level. Yellow/Orange Blue Blue Black White/Blue SP20-RD4 Blue Red White Red Black Insulating Label Violet Blue Red Black Black 0-10 VDC Ballast Gray Green Ground White/Blue SP20-RD4 White Red Gray Yellow/Orange Blue Blue Black Violet White • L ights Flickering - Lamp has a bad connection. - Wires not secured firmly with wire connectors. • Light does not turn ON - Circuit breaker or fuse has tripped. - Lamp is burned out. - Lamp Neutral connection is not wired. WBSD-010M-C1 Dimmer Black 0-10 VDC Ballast Gray White Violet Neutral (White) Wiring Diagram 3: Two Location Control Hot (Black) WIRE CONNECTOR / # OF COND. COMBINATION CHART Line 120/277VAC, 60Hz Red Violet Gray Red Black To Lamps Black Screw (common) 1- #12 w/ 1 to 3 #14, #16 or #18 2- #12 w/ 1 or 2 #16 or #18 1- #14 w/ 1 to 4 #16 or #18 2- #14 w/ 1 to 3 #16 or #18 To Additional Ballasts Gray Violet Dimmer 3-Way Switch For non-standard wiring applications, refer to Wire Nut and Connector Size Chart Restore power at circuit breaker or fuse. Installation is complete. White Blue Wiring Diagram 2 : Single Location Control with SP20-RD4 switchpacks Hot (Black) TROUBLESHOOTING Restore Power: Red 0-10 VDC Ballast Setting the Maximum Light Level Black Step 7 Primary Side Green Ground 1. Locate the "Trim Adjustment" dial on the top of the dimmer. TURN OFF POWER AT CIRCUIT BREAKER OR FUSE. Installation may now be completed by carefully positioning all wires to provide room in wall box for dimmer. Mount dimmer into box with mounting screws supplied. Attach wallplate. To Additional Ballasts Gray Violet Neutral (White) Trim Adjustment Dial Step 6 Wiring Diagram 1 : Single Location Control Black Green Ground Green Ground Primary Side White Red 0-10 VDC Ballast Blue Yellow Neutral (White) For additional information, contact Eaton’s technical support line at 1-800-553-3879 or visit www.eaton.com/lighting Copyright © 2018 Eaton Manufacturing Co., Inc. All rights Including Trade Dress Rights Reserved. Third party trademarks are the property of their respective owners For Technical Assistance Call: 1-800-553-3879 (U.S.A. Only) www.eaton.com/lighting DI-420-IP710-02A LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Eaton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Eaton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Eaton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www. eaton.com/lighting or call 1-800-553-3879. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Eaton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project