Rane | RPD 1 | Data Sheet | Rane RPD 1 Remote Programming & Diagnostics Data Sheet

Rane RPD 1 Remote Programming & Diagnostics Data Sheet
DATA SHEET
RPD 1
REMOTE PROGRAMMING & DIAGNOSTICS
General Description
Through the use of a modem and telephone lines, the
RPD 1 allows remote control, programming, and diagnostics
of remote sites using RaneWare RW 232 products. These
include the RPE 228d Programmable Equalizer, the RPM 26v
Programmable Multifunction Processor, and the Engineered
Conferencing Systems line of products.
Used in conjunction with a standard, off the shelf modem
(not included), the RPD 1 is easily upgradable as improved
technology becomes available. The Rane RPD 1 provides
standard RS-232 connection for remote system diagnostics,
and communication with the room controller from a remote
location.
Any modem may be used with the RPD 1. There are two
types of data connections: RW 232 and User Data serial
connections (both utilize the RS-232 standard). Placing and
answering telephone calls over the modem is performed using
a PC or laptop computer connected to the local RPD 1’s RW
232 Control Input Port. Remote diagnostics and programming
is enabled by connecting the remote RPD 1’s User Data (RS232) port to the Program Port of the control system.
A password protected ‘firewall’ is provided within the
RPD 1. The password adds security to incoming calls
containing data, by not allowing any data to be sent to the
User Data or RW 232 Control Ports until the password is
entered. Re-routing data to a remote location from the RW
232 Control Output Port instead of the User Data Port allows
control of RW 232 devices from a remote site.
A modem cable is included for modem connection. RS232 connects the RPD 1 to any control system.
RaneWare® is software that runs the RPD 1 under
Microsoft Windows95(SE)/98®, allowing real time control.
The software’s graphical interface features control of all
parameters and extensive on-line help. RaneWare is
downloadable from Rane’s web site, http://www.rane.com.
The following is recommended as a minimum system:
• 80386SX with 80387 coprocessor, 33 MHz
• Unused serial port
• 4M RAM
• Windows 3.1, 95(SE) or 98
• Color monitor
Powered from UL listed, CE approved remote power
supplies, the RPD 1 is exempt from safety agency requirements, and may be used in any installation mandating agency
compliance.
Features
•
•
•
•
•
Password protected data access from remote sites
Standard RS-232 user data connection up to 19.2 kbs for remote system diagnostics
Separate RW 232 connection for RaneWare system diagnostics & control
Custom cables provided for connection between RPD 1 and modem
UL/CSA/CE and 100/120/230 VAC Remote Power Supplies
Windows is a registered trademark of Microsoft Corporation
RaneWare is a registered trademark of Rane Corporation
Data Sheet-1
RPD 1
REMOTE PROGRAMMING & DIAGNOSTICS
Features and Specifications
Parameter
Specification
Frequency Response
120 to 3.5k
Input Impedance
10k
Audio Output Type
Active Balanced
..........Impedance
100
THD
0.1
Signal-To-Noise
60
CMRR
20
Data Control Connection
RW 232
Modem Connection
RS-232
Max User Data Rate
19.2
Protocol: RW 232 Port
8 bit, Even Parity
........User Data & Modem Ports 8 bit, No Parity
Unit: Agency Listing
..........120 VAC Model
Class 2 Equipment
UL
CSA
FCC part 15J
..........230 VAC Model
VDE, SELV
CE-EMC
CE-Safety Exempt
Power Supply: Agency Listing
..........120 VAC Model
UL
CSA
..........230 VAC Model
CE-EMC
CE-Safety
..........100 VAC Model
Built to JIS
Power Supply: Requirement
18 VAC w/ center tap
..........Maximum Current
650
Unit: Construction
All Steel
..........Size
1.75" H x 19" W x 8.5" D (1U)
..........Weight
6 lb (w/o power supply)
Shipping: Size
4.5" x 20.3" x 13.75"
..........Weight
11 lb
Limit
max
min
min
ohms
%
dB
dB
Conditions/Comments
Active Balanced
Euroblock Connectors
@ 0 dBu ref, 160-4800 Hz BW
@ 1 kHz
DB-9 Male
DB-25 Female
kbs
RS-232
RS-232
National Electrical Code
Exempt Class 2 equipment
Exempt Class 2 equipment
Certified Class B Device
Safety Extra Low Voltage
EMC Directive 89/336/EEC
Article 1 of LV Directive 73/23/EEC
File no. E88261
File no. LR58948
EMC Directive 89/336/EEC
LV Directive 73/23/EEC
Japan only
10%
Note: 0 dBu=0.775 Vrms
RPD 1 Modem Compatibility
The modem to be used with the RPD 1 must meet these criteria:
1. 28.8 kbps minimum speed (for data), 23.3 kbps (for voice only).
2. External
3. Hayes compatible
Data Sheet-2
Units
Hz
ohms
Vrms
mA
RMS Current From Remote Supply
(4.4 cm x 48.3 cm x 21.6 cm)
(2.7 kg)
(11.5 cm x 52 cm x 35 cm)
(5.0 kg)
RPD 1
REMOTE PROGRAMMING & DIAGNOSTICS
Block Diagram
Data Sheet-3
RPD 1
REMOTE PROGRAMMING & DIAGNOSTICS
Rear Panel
RaneWare RPD 1 Screens
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com
Data Sheet-4
All features & specifications subject to change without notice. DOC 103072 PN 08284 5-98