Honeywell | 13e Subminiature Load Cell | Datasheet | Honeywell 13e Subminiature Load Cell Datasheet

Honeywell 13e Subminiature Load Cell Datasheet
Model 13E
Subminiature Load Cell
DESCRIPTION
Model 13E (compression only) subminiature load cell is
into systems having limited space. Model 13E combines high
designed to measure load ranges from 0.5 N to 5 kN. With
frequency response and low deflection to achieve a combined
subminiature dimensions, including diameters from 9,7 mm
non-linearity and hysteresis of 0.25 % to 0.5 % full scale. A
to 19,1 mm [0.38 in to 0.75 in] and heights of 3,3 mm to 6,4
balance module is included in the load cell’s lead wire cable for
mm [0.13 in to 0.25 in], these units are easily incorporated
temperature compensation and should not be removed.
FEATURES
•
0.5 N to 5 kN
•
mV/V output
•
Subminiature design
•
Fast dynamic response
Model 13E
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range codes
Range
Load ranges
0.5 N to 5kN
000N5
0.5 N
Linearity
±0.5 % full scale
001N5
1.5 N
Hysteresis
±0.5 % full scale
002N5
2.5 N
Non-repeatability
±0.1 % full scale
005N0
5N
Tolerance on output
0.5 N to 5 N
15 mV/V (nominal)
010N0
10 N
Tolerance on output 10 N
1.5 mV/V (nominal)
020N0
20 N
Tolerance on output
20 N to 5 kN
050N0
50 N
2 mV/V (nominal)
100N0
100 N
Operation
Compression only
200N0
200 N
Resolution
Infinite
500N0
500 N
01KN0
1 kN
02KN0
2 kN
05KN0
5 kN
6
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-55 °C to 120 °C [-65 °F to 248 °F]
Temperature, compensated
15 °C to 70 °C [60 °F to 158 °F]
Temperature effect, zero
0.02 % full scale/°C
Temperature effect, span
0.04 % full scale/°C
Protection rating
IP65
ELECTRICAL SPECIFICATIONS
WIRING CODES
Cable
Unamplified
Red
(+) excitation
Black
(-) excitation
Green
(-) output
White
(+) output
Characteristic
Measure
Strain gage type
0.5 N to 5 N
Semiconductor
Strain gage type
10 N to 5 kN
Bonded foil
Capacity (lb)
Deflection at
full scale (mm)
Weight
Weight with
cable
Excitation (calibration)
5 Vdc
0.5 N
0.0015
1 g [0.002 lb]
9 g [0.019 lb]
Insulation resistance
5000 mOhm @ 50 Vdc
1.5 N
0.0015
1 g [0.002 lb]
9 g [0.019 lb]
2.5 N
0.0015
1 g [0.002 lb]
9 g [0.019 lb]
5N
0.0020
1 g [0.002 lb]
9 g [0.019 lb]
10 N
0.0127
1 g [0.002 lb]
9 g [0.019 lb]
20 N
0.0127
1 g [0.002 lb]
9 g [0.019 lb]
50 N
0.0101
1 g [0.002 lb]
9 g [0.019 lb]
100 N
0.0101
1 g [0.002 lb]
9 g [0.019 lb]
200 N
0.0101
1 g [0.002 lb]
9 g [0.019 lb]
500 N
0.0101
3 g [0.006 lb]
11 g [0.024 lb]
1 kN
0.0127
3 g [0.006 lb]
11 g [0.024 lb]
2 kN
0.0127
10 g [0.022 lb]
18 g [0.039 lb]
5 kN
0.0152
10 g [0.022 lb]
18 g [0.039 lb]
Bridge resistance (tolerance) 0.5 N to 5 N
500 ohm (nominal)
Bridge resistance (tolerance) 00 N to 5 kN
350 ohm (nominal)
Zero balance (tolerance)
±3 % of full scale (nominal)
Shunt calibration data
Included
Electrical termination (std)
1,5 m integral cable with balance
board3
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Maximum allowable load
150 % full scale1
Weight
See table
Material
Stainless steel
Deflection @ full scale
See table
2 Honeywell • Sensing and Control
DEFLECTIONS AND RINGING FREQUENCIES
Subminiature Load Cell
MOUNTING DIMENSIONS
Ranges
Range code
OD mm [in]
D1 mm [in]
H mm [in]
B mm [in]
SR mm [in]
0.5 N
000N5
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
1.5 N
001N5
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
2.5 N
002N5
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
5N
005N0
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
10 N
010N0
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
20 N
020N0
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
50 N
050N0
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
100 N
100N0
9,7 [0.38]
2,3 [0.09]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
200 N
200N0
9,7 [0.38]
2,2 [0.086]
3,3 [0.13]
0,7 [0.03]
6 [0.24]
500 N
500N0
12,7 [0.50]
3,0 [0.12]
3,8 [0.15]
0,5 [0.02]
13 [0.51]
1 kN
01KN0
12,7 [0.50]
3,0 [0.12]
3,8 [0.15]
0,5 [0.02]
13 [0.51]
2 kN
02KN0
19,1 [0.75]
6,4 [0.25]
6,4 [0.25]
0,6 [0.023]
13 [0.51]
5 kN
05KN0
19,1 [0.75]
6,4 [0.25]
6,4 [0.25]
0,6 [0.023]
13 [0.51]
OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load range
0.5, 1.5, 2.5, 5, 10, 20, 50, 200, 500, 1K, 2K, 5K N
Temperature
compensation
1a. 15 °C to 70 °C
1j. -65 °C to 50 °C
1k. -20 °C to 85 °C
Internal
amplifiers
2u. Unamplified, mV/V output
Electrical
termination
1,5 m integral cable with balance board3
6a. Bendix PTIH-10-6P - (or equivalent) 6 pin
(max. 120 °C) on end of cable
6e. Integral cable: Teflon
6v. Phoenix connector on end of cable
Electrical con- 15d. Connector on end of cable
nector orientation
Load direction 30c. Negative in compression, compression testing only
Shock and
vibration
44a. Shock and vibration resistance
Honeywell • Sensing and Control 3
Model 13E
Subminiature Load Cell
NOTES
1.
2.
3.
4.
5.
6.
Allowable maximum loads – maximum load to be applied without
damage.2 Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
A small 50 mm long x 2 mm thick circuit board is located approximately 60 cm from cell body. Do not remove this board.
Only for ranges greater-than-or-equal-to 10 N.
Specifications may vary with this option.
This unit is calibrated to Metric (non-Imperial) units.
TYPICAL SYSTEM DIAGRAM
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008642-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising