Honeywell | 3167 Pancake Load Cell | Datasheet | Honeywell 3167 Pancake Load Cell Datasheet

Honeywell 3167 Pancake Load Cell Datasheet
Model 3167
Tension/Compression Pancake Load Cell
DESCRIPTION
These general purpose designs have exceptional structural
Minimum deflection and compactness make these general-
capability to withstand extraneous loads, such as torque,
purpose load cells easy to install and use.
bending moments, and side loads.
Available in capacities of 25 lb to 300 lb, they offer maximum
performance and enhanced accuracy.
FEATURES
•
Up to 0.05 % accuracy
•
25 lb to 300 lb range
•
Integral cable (standard)
•
Low sensitivity to extraneous loads
•
Low deflection
•
Built-in temperature compensation
Model 3167
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
1
Load range
25, 50, 100, 200, 300 lb
Non-linearity
±0.05 % of rated output
Hysteresis
±0.05 % of rated output
Repeatability
±0.02 % of rated output
Output @ rated capacity
2 mV/V ±0.25 % (nominal)
Operation
Tension/compression
Resolution
Infinite
Standard calibration
Tension (+) and compression (-)
TYPICAL SYSTEM DIAGRAM
Output
Amplifier
Universal In-Line Amplifiers
+/-5 VDC
UV
+/-10 VDC
UV-10
0 +/-5 VDC
UBP
4-20mA (3 wire)
U3W
4-20mA (2 wire)
U2W
DIN rail Mount In-Line Amplifiers
0 +/- 5 VDC (3 wire)
DV-05
4-20mA (3 wire)
DA-05
0 +/- 10 VDC (3 wire)
DV10
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated
21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero
±0.002 % of rated output/°F
Temperature effect, output
±0.002 % of reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Foil
Excitation (maximum)
20 Vdc or Vac RMS
Insulation resistance
> 5000 mOhm @ 50 Vdc
Bridge resistance
(tolerance)
350 ohm
Number of bridges
1
Zero balance
±5.0 %
Electrical termination
15 ft of Belden 8723 four-conductor
shielded cable
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Static overload capacity
150 % of nominal capacity
Material
Carbon steel
Natural frequency
See table
WIRING CODES
Cable
Red
(+) excitation
Black
(-) excitation
Green
(+) output
White
(-) output
2 Honeywell • Sensing and Control
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
In-Line Amplifiers
(Used with unamplified units only)
Power Supply
Honeywell
In-Line Amplifier
Output
Input
Serial Number
Display Units
SC500
SC2001
GM
7541
SC1000
SC3004
NK
7558
SC2000
HH
7561-PSD
MODEL 3167
2003.1 lb.
L1 L2 L3 L4
OR
VALUE
CLEAR
UP
DOWN
SETUP
CHAN
TARE
ENTER
EXIT
Tension/Compression Pancake Load Cell
NATURAL FREQUENCY
Nominal load limit
capacity Fz
Static extraneous load limits
lb
N
Static overShear FX or
load capacity FY (lb)
(% of nominal
capacity)
Bending MX
or MY (lb-in)
Torque MZ
(lb-in)
Deflection at
nominal load
limit (in)
Ringing frequency (Hz)
25
125
150
150
150
40
0.003
2100
50
200
150
150
150
40
0.003
2800
100
500
150
250
180
40
0.003
3800
200
1K
150
250
180
40
0.003
5400
300
1.5K
150
250
180
40
0.003
7000
MOUNTING DIMENSIONS
Model
A cm [in]
B cm [in]
C cm [in]
D cm [in]
E cm [in]
3167
5,72 [2.25]
- [1/4-28]
0,95 [0.38]
1,10 [0.44]
1,10 [0.44]
F cm [in]
G cm [in]
G cm [in]
J cm [in]
K cm [in]
0,24 [0.09]
3,80 [1.50]
0,16 [0.06]
4,44 [1.75]
6,98 [2.75]
B UNF THD.
C DEEP BOTH ENDS
A +/- H
FOUR COND. SHIELD CABLE
BELDEN 8723
15 FEET
E
F
G
D
J DIA.
H
K DIA.
Honeywell • Sensing and Control
3
Model 3167
Tension/Compression Pancake Load Cell
NOTES
1. This unit calibrated to Imperial (non-Metric) units.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008622-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising