Honeywell | 31e High Miniature Load Cell | Datasheet | Honeywell 31e High Miniature Load Cell Datasheet

Honeywell 31e High Miniature Load Cell Datasheet
Model 31E High
High Range Precision Miniature Load Cell
DESCRIPTION
Model 31E high range precision miniature load cells measure
term stability for ranges 1000 grams and above.) A modification
both tension and compression load forces of 10 kN to 50 kN.
permits this model to be completely welded for underwater
These models are our highest accuracy, rugged miniature
applications. The Model 31E tension/compression load cell has
load cells. Model 31E’s welded, stainless steel construction is
male threads attachments. High accuracies of 0.15 % to 0.25 %
designed to eliminate or reduce to a minimum, the effects of
full scale are achieved. Each bonded strain gage unit is built of
off-axis loads. (The internal construction assures excellent long-
welded 17-4 PH stainless steel for additional ruggedness.
FEATURES
•
10 kN to 50 kN
•
mV/V output
•
Stainless steel
•
Miniature design
•
Stabilized column construction
Model 31E High
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range codes
Range
Load ranges
10 kN, 20 kN, 50 kN
10KN0
10 kN
Linearity
±0.2 % full scale
20KN0
20 kN
Hysteresis
±0.2 % full scale
50KN0
50 kN
Non-repeatability
±0.05 % full scale
Tolerance on output
2 mV/V
Operation
Tension/compression 3
Resolution
Infinite
5
DEFLECTIONS AND RINGING FREQUENCIES
Capacity
(lb)
Deflection at full
scale
Ringing
frequency (Hz)
Weight
10 kN
0,02 mm [0.0007 in]
26000 Hz
60 g
[0.132]
20 kN
0,03 mm [0.0001 in]
21000 Hz
125 g
[0.276]
50 kN
0,03 mm [0.0001 in]
17000 Hz
250 g
[0.551]
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-55 °C to 120 °C [-67 °F to 248 °F]
Temperature, compensated
15 °C to 70 °C [60 °F to 158 °F]
Storage temperature
-70 °C to 150 °C [-100 °F to 302 °F]
Temperature effect, zero
0.01 % full scale/°C
Temperature effect, span
0.01 % full scale/°C
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
5 Vdc
Insulation resistance
5000 Mohm @ 50 Vdc
Bridge resistance
350 ohm
Zero balance
1 % max.
Electrical termination (std)
Teflon cable (1,5 m [60 in])
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Maximum allowable load
150 % FS1
Weight
See table
Material
17-4 PH stainless steel
Deflection full scale
See table
Natural frequency
See table
WIRING CODES
Cable
Unamplified
Red
(+) excitation
Black
(-) excitation
Green
(-) output
White
(+) output
2 Honeywell • Sensing and Control
High Range Precision Miniature Load Cell
MOUNTING DIMENSIONS
Ranges (lb)
T
ØD
C
H
10
M10 x 1.5
25,4 [1.0]
18,3 [0.72]
12,7 [0.5]
20
M12 x 1.5
31,8 [1.25]
23,9 [0.94]
16,0 [0.63]
50
M20 x 1.5
35,1 [1.38]
27,9 [1.1]
22,3 [0.88]
OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://sensing.honeywell.
com/TMsensor-ship for updated listings.
Load range
10 kN, 20 kN, 50 kN
Temperature
compensation
1a. 60 °F to 160 °F
1j. 0 °C to 50 °C
Internal
amplifiers
2u. Unamplified, mV/V output
Electrical
termination
6e. Integral cable:
Teflon
6d. Microtec DR-4S-4H
4 pin
6f. Integral cable: PVC
6g. Integral cable:
Neoprene (max.
180 °F)
Bridge
resistance
12a. 1000 ohm (foil)
12b. 5000 ohm (foil)
Electrical
connector
orientation
15a. Horizontal electrical exit port orientation
15b. Vertical electrical exit port orientation
15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special
calibration
30a. Compression only calibration, positive in
compression
30b. Tension and compression calibration, positive in tension
30c. Compression only calibration, negative in
compression
30d. Tension and compression calibration, positive in compression
Shock and
vibration
44a. Shock and vibration resistance
Interfaces
53e. Signature calibration6
53t. TEDS IEEE 1451.4 module4
1k. -20 °C to 85 °C
1m. -25 ° to 110 °C
6h. Integral cable: Silicone
6i. Integral underwater
cable (max. 180 °F)
6v. Phoenix connector on
end of cable
Honeywell • Sensing and Control 3
Model 31E High
High Range Precision Miniature Load Cell
NOTES
1.
2.
3.
4.
5.
6.
Allowable maximum loads – maximum load to be applied without
damage.2 Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
Standard calibration for tension/compression load cells is in tension
only.
TEDS available with integral cable units only.
This unit is calibrated to Metric (non-Imperial) units.
Signature calibration only available as inline module.
TYPICAL SYSTEM DIAGRAM
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008634-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.