Honeywell | 911FMD Mid Differential Pressure Transducer | Datasheet | Honeywell 911FMD Mid Differential Pressure Transducer Datasheet

Honeywell 911FMD Mid Differential Pressure Transducer Datasheet
Model 911FMD
Mid Range Wet/Wet
Differential Pressure Transducer
DESCRIPTION
The two-wire Model 911FMD transmitter has stainless steel
mA current output permits long cable runs with a high signal-to-
diaphragms for use with liquid, gas, or vapors in hazardous envi-
noise ratio. This model is constructed with stainless steel, sealed
ronments. These transducers are corrosion and shock resistant,
hermetically.
as well as reverse polarity protected. The two-wire, 4 mA to 20
FEATURES
•
0.25 % accuracy
•
50 psid to 750 psid
•
4 mA to 20 mA two-wire (standard)
Model 911FMD
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Pressure ranges
RANGE CODES
50, 75, 100, 150, 200, 300, 500, 750
psid
Range
Code
Available
ranges
Range
Code
Available
ranges
BN
50 psid
CL
200 psid
Accuracy
±0.25 % full scale
BP
75 psid
CP
300 psid
Linearity
±0.15 % full scale (typical)
BR
100 psid
CR
500 psid
Hysteresis
±0.10 % full scale (typical)
CJ
150 psid
CT
750 psid
Non-repeatability
±0.05 % full scale (typical)
Output (standard)
4 mA to 20 mA
Line pressure
1500 psi
Resolution
Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated
16 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero
±1.2 % full scale/38 °C [100 °F]
Temperature, effect, span
±1.2 % reading/38 °C [100 °F]
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
15 Vdc to 50 Vdc
Shunt calibration data
Included
Elec. termination (std)
22 GA cable with case ground 609,6
mm [2 ft], 1/2-14NPT
MECHANICAL SPECIFICATIONS
OPTION CODES
Many range/option combinations are available
in our quick-ship and fast-track manufacture
programs. Please see http://measurementsensors.
honeywell.com for updated listings.
Pressure
ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750
Temperature
compensation
1b. 60 °F to 160 °F
Internal
amplifiers
2k. 4 mA to 20 mA (two-wire)
Pressure ports
5h. 1/8-27 NPT female (2)
Electrical
termination
6j. 22 GA cable with case ground 609,
6 mm [2 ft], 1/2 NPT to 14 NPT
Special
calibration
9a. 10 point (5 up/5 down)
20% increments @ 20 °C [68 °F]
9b. 20 point (10 up/10 down)
10% increments @ 20 °C [68 °F]
Wetted
diaphragm
17-4 PH stainless steel
WIRING CODES
Characteristic
Measure
CABLE/ TWO-WIRE CURRENT/ 4 MA TO 20 MA
Media
Gas, liquid
Red
(+) supply
Overload-safe (either side)
1500 psi
Black
(+) output (4 mA to 20 mA)
Pressure port
1/8-27 NPT female
White
Case ground
Wetted parts material
17-4 PH stainless steel
Case material
Stainless steel
2 Honeywell • Sensing and Control
Model 911FMD
Mid Range Wet/Wet Differential Pressure Transducer
MOUNTING DIMENSIONS AND CHARACTERISTICS
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
TYPICAL SYSTEM DIAGRAM
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Adaptors compatible
with 1/8-27 NPT
Female
Model 911FMD
Display units
SC500
SC2001
SC3004
GM-A
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
Find out more
Honeywell serves its customers through a
worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s test and mea-
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
surement products, call +1-614-850-5000, visit
http://measurementsensors.honeywell.com,
or e-mail inquiries to info.tm@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
008707-2-EN IL50 GLO
December 2011
Copyright © 2011 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising