Honeywell | A-5 Mid Differential Pressure Transducer | Datasheet | Honeywell A-5 Mid Differential Pressure Transducer Datasheet

Honeywell A-5 Mid Differential Pressure Transducer Datasheet
Model A-5
Mid Range Wet/Wet
Differential Pressure Transducer
DESCRIPTION
Model A-5 mid-range Wet/Wet Differential is a bonded foil strain
A variety of standard options are available with the Model A-5 in-
gage transducers designed to accept fluid in both ports and
cluding the traditional removable pressure adaptors for cleaning
measure differential pressure ranges from 50 psid to 750 psid.
purposes, extended temperature ranges, alternative pressure
Standard features such as overload stops and stainless steel
ports, internal amplifiers options, and electrical terminations.
construction provide unit durability in rugged industrial environments. Each is bi-directional and achieves accuracies of 0.5 %
full scale.
FEATURES
•
0.5% accuracy
•
50 psid to 750 psid
•
mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
•
Intrinsically safe available (2N option only)10
•
CE approved11
Model A-5
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Pressure ranges
50, 75, 100, 150, 200, 300, 500, 750
psid
Accuracy
±0.5 % full scale
Linearity
±0.25 % full scale (typical)
Hysteresis
±0.13 % full scale (typical)
Non-repeatability
±0.07 % full scale (typical)
Output (standard)
2 mV/V (nominal)
Line pressure
1500 psi
Resolution
Infinite
ENVIRONMENTAL SPECIFICATIONS
OPTION CODES
Range Code
Pressure ranges
(psid)
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
50, 75, 100, 150, 200, 300, 500, 750
Temperature
compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1j. 0 °C to 50 °C
1i. -65 °F to 250 °F6
1m. -25 °C to 110 °C
1g. 70 °F to 325 °F6
1h. 70 °F to 400 °F6
Internal
amplifiers
2b. 4 wire ±5 Vdc
2c. 0 Vdc to 5 Vdc
2j. 4 mA to 20 mA
(3-wire) output
2k. 4 mA to 20 mA
(two-wire) output12
2n. (2N) 4 mA to 20
mA (2 wire) intrinsically safe12
2t. 0 Vdc to 10 Vdc
2u. Unamplified, mV/V
output
Characteristic
Measure
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero
±0.75 % full scale/100 °F
Internal amp
enhancements
3a. Input/output isolation8
3d. Remote buffered shunt calibration
Temperature, effect, span
±1.0 % reading/100 °F
Pressure ports5
5h. 1/8-27 NPT female (2)
5c. 7/16 in -20 UNF female (per MS33656E4)
Electrical
termination
6a. Bendix PTIH-10-6P
(or equiv.) 6 pin
(max. 250 °F)
6b. MS type connector to
mate MS3106-14S6S (max. 160 °F)1
6e. Integral cable:
Teflon (-54 °C to
245 °C)
6f. Integral cable: PVC
(-30 °C to 70 °C)
Shunt
calibration
8a. Precision internal resistor 6
Special
calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C
9b. 20 point (10 up/10 down) 10% increments @ 20 °C
Wetted
diaphragm
17-4 PH stainless steel
10a. 316 stainless steel
Bridge type
11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero &
span adjustment
14a. No access
14b. Top access6
O-ring seals
26a. Metal
26b. Vi-Ton
26c. Teflon
Interfaces
53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
10 Vdc
Excitation (acceptable)
Up to 10 Vdc or ac
Insulation resistance
5000 mOhm @ 50 Vdc
Bridge resistance
350 ohm
Shunt calibration data
Included
Elec. termination (std)
Bendix PTIH-10-6P or equivalent
(hermetic stainless)
Mating connector (not incl.)
Bendix PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
Gas, liquid
Overload-safe
1500 psi
Pressure port
1/8-27 NPT female (2)
Dead volume
0.25 cu. in
Wetted parts material
17-4 PH stainless steel
Weight
2,3 kg [5 lb]
Case material
Stainless steel
2 Honeywell • Sensing and Control
6g. Integral cable:
Neoprene (-20 °C
to 80 °C) 1
6h. Integral cable:
Silicone (-54 °C to
150 °C)
6i. Integral underwater
cable (8 m [26 ft])
(max. 80°C)1
6j. 1/2-14 conduit fitting
with 1,5 m [5 ft] of
4 conductor PVC
cable
Mid Range Wet/Wet Differential Pressure Transducer
INTERNAL AMPLIFIERS
Amplifier
specifications
Voltage
output:
Option 2b
Voltage
output:
Option 2c
Voltage
output:
Option 2t
Current threewire: Option 2j
Current twowire: Option
2k
Intrinsically
safe amp: Option 2n (2N)***
Output signal
±5 V
0 V to 5 V or ±5 V
@ 5 mA
0 V to 10 V or
±10 V @ 5 mA
4 mA to 20 mA
4 mA to 20 mA
4 mA to 20 mA
Input power (voltage)
±15 V or 26 Vdc
to 32 Vdc
11 Vdc to 28 Vdc
15 Vdc to 28 Vdc
22 Vdc to 32 Vdc
9 Vdc to 32 Vdc
9 Vdc to 28 Vdc
Input power (current)
45 mA
40 mA
40 mA
65 mA
4 mA to 28 mA
4 mA to 24 mA
Freq. resp (amp)
3000 Hz
3000 Hz
3000 Hz
2500 Hz
300 Hz
2000 Hz
Power supply rejection
60 db
60 db
60 db
60 db
60 db
60 db
Operating temperature
-20 °F to 185 °F
-20 °F to 185 °F
-20 °F to 185 °F
0 °F to 185 °F
0 °F to 185 °F
-20 °F to 185 °F
Reverse volt. protection
Yes
Yes
Yes
Yes
Yes
Yes
Short circuit protection
Momentary
Momentary
Momentary
Yes
Yes
Yes
Wiring code:
connector (std)2
A (+) Supply
B Output common
C Supply return
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return **
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
Wiring code:
cable2,3,4
R (+) Supply
Bl Output common
G Supply return
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl (+) Output
W Case ground
R (+) Supply
Bl (+) Output
W Case ground
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.
Mounting dimensions and characteristics
TYPICAL SYSTEM DIAGRAM
Honeywell • Sensing and Control
3
Model A-5
Mid Range Wet/Wet Differential Pressure Transducer
RANGE CODES
Range
Code
Available
ranges
Range
Code
Available
ranges
BN
±50 psid
CL
±200 psid
BP
±75 psid
CP
±300 psid
BR
±100 psid
CR
±500 psid
CJ
±150 psid
CT
±750 psid
WIRING CODES
Connector
Unamplified
A, B
(+) excitation
C, D
(-) excitation
E
(-) output
F
(+) output
NOTES
1.
2.
3. 4.
5.
6.
7.
8.
9.
10.
11.
12.
Availability varies according to range.
Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire
units) or 80% (voltage amplified units of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier
options 2b, 2c, 2t and 2j.
O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown,
W=White, G=Green. Color specifying cable and number or letter
specifying connector.
No mating connector necessary for cable option.
Some pressure port options may require axial orientation.
Only available with unamplified option 2u.
Only available with amplified options.
Only available with Vdc output options 2b, 2c.
Consult factory for TEDS availability with amplified models.
Range dependent; consult factory. Termination dependent; consult
factory.
Internal amp and termination dependent; consult factory.
5000 ohm bridge required.
Note: Unless otherwise specified on order, amplified units with 4 mA to
20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale
and the unit will not operate in the negative direction. An available is to
specify 4 mA at negative full scale and 20 mA at positive full scale. All
amps add 2 in to housing.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could
result in death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference
only. DO NOT USE this document as product installation
information.
• Complete installation, operation and maintenance information
is provided in the instructions supplied with each product.
Failure to comply with these instructions could
result in death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008722-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising