Model LFH-7I
Top Hat Subminiature Load Cell
DESCRIPTION
Model LFH-7I subminiature load cell is a low profile force
accuracy of ±0.7 % full scale. The top of the load cell is the area
transducer for applications with minimal space and high
where the force is applied and the base ring of the load cell
capacity requirements. This transducer utilizes foil strain gages
must be placed on a hard, machine-ground flat surface to obtain
to measure compression loads of up to 10,000 lb and achieves
optimum accuracy.
FEATURES
•
250 lb to 10000 lb range
•
±0.7 % full scale accuracy1
•
Stainless steel
•
Column construction
•
mV/V output
Model LFH-7I
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range codes
Range
Load ranges
250 lb to 10000 lb
CN
250 lb
Accuracy
±0.7 % full scale1
CR
500 lb
Full scale output (tolerance)
1.5 mV/V nom., 250 lb
2.5 mV/V nom, 500 lb to 10K lb
CV
1000 lb
Operation
Compression only
DL
2000 lb
DN
3000 lb
DP
4000 lb
DR
5000 lb
DT
7500 lb
DV
10000 lb
4
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
Storage temperature
-70 °C to 149 °C [-100 °F to 300 °F]
Temperature effect, zero
±0.01 % full scale/°F
Temperature effect, span
±0.01 % full scale/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
5 Vdc
Insulation resistance
5000 Mohm @ 50 Vdc
Bridge resistance
350 ohm, 250 lb to 5K lb
700 ohm, 7.5K lb to 10K lb
Zero balance
±5 % full scale
Electrical termination (std)
Cable (1,83 m [5 ft])
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Maximum allowable load
150 % full scale
Weight
See table
Material
17-4 PH stainless steel
Deflection full scale
See table
Natural frequency
See table
WIRING CODES
Cable
Unamplified
Red
(+) excitation
Black
(-) excitation
Green
(-) output
White
(+) output
2 Honeywell • Sensing and Control
2
DEFLECTIONS AND RINGING FREQUENCIES
Capacity
Deflection at full
scale
Ringing frequency (kHz)
Weight
250 lb
0,0127 mm [0.0005 in]
30
10 g
[0.022 lb]
500 lb
0,0127 mm [0.0005 in]
34
10 g
[0.022 lb]
1000 lb
0,03 mm [0.001 in]
37
10 g
[0.022 lb]
2000 lb
0,03 mm [0.001 in]
44
10 g
[0.022 lb]
3000 lb
0,03 mm [0.001 in]
46
10 g
[0.022 lb]
5000 lb
0,03 mm [0.001 in]
47
30 g
[0.066 lb]
7500 lb
0,038 mm [0.0015 in]
44
30 g
[0.066 lb]
10000 lb
0,04 mm [0.002 in]
40
30 g
[0.066 lb]
Top Hat Subminiature Load Cell
MOUNTING DIMENSIONS
Ranges ØD1 mm [in]
ØD2 mm [in]
H mm [in]
F mm [in]
W mm [in]
250 lb
12,7 [0.50]
6,86 [0.27]
9,65 [0.38]
3,3 [0.13]
10,92 [0.43]
500 lb
12,7 [0.50]
7,11 [0.28]
9,65 [0.38]
3,3 [0.13]
10,92 [0.43]
1000 lb
12,7 [0.50]
7,87 [0.31]
9,65 [0.38]
3,3 [0.13]
10,92 [0.43]
2000 lb
12,7 [0.50]
10,41 [0.41]
9,65 [0.38]
3,3 [0.13]
10,92 [0.43]
3000 lb
12,7 [0.50]
11,43 [0.45]
9,65 [0.38]
3,3 [0.13]
11,68 [0.46]
5000 lb
16,00 [0.63]
13,46 [0.53]
15,24 [0.60]
5,84 [0.23]
12,95 [0.51]
7500 lb
22,35 [0.88]
16,00 [0.63]
16,00 [0.63]
13,72 [0.54]
16,00 [0.63]
10000 lb
22,35 [0.88]
16,00 [0.63]
16,00 [0.63]
13,72 [0.54]
16,00 [0.63]
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://measurementsensors.honeywell.com for updated listings.
Load range
250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000 lb
Temperature compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
Internal amplifiers
2u. Unamplified, mV/V output
Electrical termination
6e. Integral cable: Teflon
6h. Integral cable: Silicone
6v. Phoenix connector on end of cable
15d. Connector on end of cable
Special calibration
9a. 10 point (5 up/5 down) 20 % increments @ 70 °F
9b. 20 point (10 up/10 down) 10 % increments @ 70 °F
Shock and vibration
44a. Shock and vibration resistance
Honeywell • Sensing and Control
3
Model LFH-7I
Top Hat Subminiature Load Cell
NOTES
1.
2.
3.
4.
Accuracies stated are expected for best-fit straight line for all errors
including linearity, hysteresis and repeatability through zero.
Allowable maximum loads – maximum load to be applied without
damage.3
Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
This unit calibrated to Imperial (non-Metric) units.
TYPICAL SYSTEM DIAGRAM
In-line amplifiers (used with unamplified units only)
Amplifier Output
Universal in-line amplifiers
UV
±5 Vdc
UV-10
±10 Vdc
UBP
0 ±5 Vdc
U3W
4 mA to 20 mA (3-wire)
DIN rail mount in-line amplifiers
DV-05
0 ±5 Vdc (3-wire)
DA-05
4 mA to 20 mA (3-wire)
DV-10
0 ±10 Vdc (3-wire)
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
WARNING
Model LFH-7I
PERSONAL INJURY
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
and distributors. For application
assistance, current specifica-
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
Display units
SC500
SC2000
SC2001
SC3004
GM
NK
HH
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inquiries to info.tm@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
008640-2-EN IL50 GLO
April 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising