Honeywell | TJE Low All-Welded Differential Pressure Transducer | Datasheet | Honeywell TJE Low All-Welded Differential Pressure Transducer Datasheet

Honeywell TJE Low All-Welded Differential Pressure Transducer Datasheet
Model TJE
Low Range Wet/Wet Differential
All-Welded Pressure Transducer
DESCRIPTION
The Model TJE offers an all-welded stainless steel assembly that
A variety of options are available with the Model TJE including
eliminates internal “O” ring leaks and material compatibility. The
choice of pressure adaptors, pressure ports, internal amplifiers,
Model TJE line pressure zero shift specification can be reduced
and electrical terminations.
to less than 0.5 % FS/1000 psi by the use of an internal line
pressure sensor and analog correction circuit. Line pressures
are available up to 5000 psig with safe overload of either side
up to the maximum line rating. The natural resonant frequency is
increased with the Model TJE because of a stiffer pressure sensing element and the all-welded assembly.
FEATURES
•
0.1 % FS accuracy
•
0.5 psid to 30 psid
•
All-welded design
•
mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
•
CE approved
Model TJE
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Pressure ranges
±0.5, 1, 2, 5, 10, 15, 25, 30 psid**
Accuracy
±0.1 % full scale
Output (standard) 0.5 psid
1.0 mV/V (nominal)
Output (standard)
1 to 4 psid
1.5 mV/V (nominal)
Output (standard)
5 to 30 psid
2.0 mV/V (nominal)
Line pressure
1500 psi
Resolution
Infinite
OPTION CODES
Range Code
Pressure ranges
(psid)
Measure
Temperature, operating
-1 °C to 88 °C [30 °F to 190 °F]
Temperature, compensated
-1 °C to 54 °C [30 °F to 130 °F]
Temperature, effect, zero
±0.5 % full scale/100 °F
Temperature, effect, span
±0.5 % reading/100 °F
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1j. 0 °C to 50 °C
Internal
amplifiers
2b. 4 wire ±5 Vdc
2c. 0 Vdc to 5 Vdc
2j. 4 mA to 20 mA
(three-wire) output10
2k. 4 mA to 20 mA
(two-wire) output10
2n. (2N) 4 mA to 20
mA (two-wire)
intrinsically safe10
2t. 0 Vdc to 10 Vdc
2u. Unamplified, mV/V
output
Internal amp
enhancements
3a. Input/output isolation8
3d. Remote buffered shunt calibration
Pressure ports5
5a. 1/4-18 NPT female
5c. 7/16-20 UNF female
5h. 1/8-27 NPT female (2)
Electrical
termination
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
10 Vdc
Excitation (acceptable)
Up to 10 Vdc or ac
Insulation resistance
5000 mOhm @ 50 Vdc max.
Bridge resistance
350 ohm (nominal)
Shunt calibration data
Included
Elec. termination (std)
Bendix PTIH-10-6P or equivalent
Mating connector (not incl.)
Bendix PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
1, 2, 5, 10, 15, 25, 30
Temperature
compensation
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Shunt
calibration
Special
calibration1
6a. Bendix PTIH-10-6P
(or equiv.) 6 pin
(max. 120 °C)
6e. Integral cable:
Teflon (-54 °C to
245 °C)
6f. Integral cable: PVC
(-30 °C to 70 °C)
6g. Integral cable:
Neoprene (-20 °C
to 80 °C)1
6h. Integral cable: Silicone
(-54 °C to 150 °C)
6i. Integral underwater
cable (8m [26 ft])
(max. 80 °C)1
6j. 1/2-14 conduit
fitting with 1,5 m [5 ft]
of 4 conductor PVC
cable
6m. DIN 43650
6q. Molded integral
cable:
Polyurethane1
6t. Integral cable with
heyco spring strain
relief (1.6 m [5.2 ft])
8a. Precision internal resistor6
9a. 10 point (5 up/5 down)
20 % increments @ 20 °C
9b. 20 point (10 up/10 down)
10 % increments @ 20 °C
Characteristic
Measure
Media
All fluid and gases compatible with 316
stainless steel
Wetted
diaphragm
Overload-safe
1500 psi
Bridge type
Pressure port
1/8-27 NPT female (2)
11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Dead volume
0.4 cu. in
Wetted parts material
316 stainless steel
Zero and span
adjustment
14a. No access to pots
14b. Top access to pots 7
Weight
1,9 kg [4.2 lb]
Case material
Stainless steel
Increased line
pressure
25a. 2000 psi line pressure
25b. 3000 psi line pressure
25c. 5000 psi line pressure 1
Interfaces
53e. Signature calibration6
53t. TEDS IEEE 1451.4 module 9
2 Honeywell • Sensing and Control
10a. 316 stainless steel
Low Range Wet/Wet Differential All-Welded Pressure Transducer
iNTERNAL AMPLIFIERS
Voltage output: Voltage output: Voltage output: Current threeOption 2b
Option 2c
Option 2t
wire: Option 2j
Current
two-wire:
Option 2k
Intrinsically
safe amp:
Option 2n
(2N)***
Output signal
±5 V
0 V to 5 V or
±5 V @ 5 mA
0 V to 10 V or
±10 V @ 5 mA
4 mA to 20 mA
4 mA to 20 mA
4 mA to 20 mA
Input power (voltage)
±15 V or 26 Vdc
to 32 Vdc
11 Vdc to 28 Vdc
15 Vdc to 28 Vdc
22 Vdc to 32 Vdc
9 Vdc to 32 Vdc
9 Vdc to 28 Vdc
Input power (current)
45 mA
40 mA
40 mA
65 mA
4 mA to 28 mA
4 mA to 24 mA
Freq. response (amp)
3000 Hz
3000 Hz
3000 Hz
2500 Hz
300 Hz
2000 Hz
Power supply rejection
60 db
60 db
60 db
60 db
60 db
60 db
Operating temperature
-20 °F to 185 °F
-20 °F to 185 °F
-20 °F to 185 °F
0 °F to 185 °F
0 °F to 185 °F
-20 °F to 185 °F
Reverse volt. protection
Yes
Yes
Yes
Yes
Yes
Yes
Short circuit protection
Momentary
Momentary
Momentary
Yes
Yes
Yes
Wiring code: connector
(std)2
A (+) Supply
B Output common
C Supply return
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return **
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt cal 1
F Shunt cal 2
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
Wiring code: cable2,3,4
R (+) Supply
Bl Output common
G Supply return
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl Output common*
G Supply return*
W (+) Output
B Shunt cal 1
Br Shunt cal 2
R (+) Supply
Bl (+) Output
W Case ground
R (+) Supply
Bl (+) Output
W Case ground
Amplifier
specifications
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.
TYPICAL SYSTEM DIAGRAM
50,8 mm
[2 in] max.
INSTALLATION AND MOUNTING
Honeywell • Sensing and Control 3
Model TJE
Low Range Wet/Wet Differential All-Welded Pressure Transducer
RANGE CODES
Range
Code
Available
ranges
Range
Code
Available
ranges
AP
±1 psid
BJ
±15 psid
AR
±2 psid
BL
±25 psid
AT
±5 psid
BM
±30 psid
AV
±10 psid
WIRING CODES
Connector
Unamplified
A, B
(+) excitation
C, D
(-) excitation
E
(-) output
F
(+) output
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Notes
1. Availability varies according to range.
2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire
units) or 80% (voltage amplified units) of full scale output for quick
calibration. Shunt calibration comes standard with internal amplifier
options 2b, 2c, 2t and 2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown,
W=White, G=Green. Color specifying cable and number or letter
specifying connector.
4. No mating connector necessary for cable option.
5. Some pressure port options may require axial orientation.
6. Only available with unamplified option 2u.
7. Only available with amplified options.
8. Only available with Vdc output options 2b, 2c.
9. Consult factory for TEDS availability with amplified models.
10. 5000 ohm bridge required.
11. Internal amp and termination dependent, consult factory.
** Option: also available, equivalent inches of water column, inches of
HG column, mBar or kPa for pressure ranges
Note: Unless otherwise specified on order, amplified units with 4 mA to
20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale
and the unit will not operate in the negative direction. An available is to
specify 4 mA at negative full scale and 20 mA at positive full scale. All
amps add 2 in to housing.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference
only. DO NOT USE this document as product installation
information.
• Complete installation, operation and maintenance information
is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008768-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising