Honeywell | 32328692SZL-VL-S Miniature Industrial Limit Switch | Installation Instruction | Honeywell 32328692SZL-VL-S Miniature Industrial Limit Switch Installation Instruction

Honeywell 32328692SZL-VL-S Miniature Industrial Limit Switch Installation Instruction
Installation Instructions for the
MICRO SWITCH SZL-VL-S
Miniature Limit Switch
Issue C
32328692
3.
mWARNING
3a. Torque switch to mounting surface: 2,5 Nm to 3 Nm
[22.1 in-lb to 26.6 in-lb] using M4 screw
PERSONAL INJURY
DO NOT use these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
mWARNING
IMPROPER INSTALLATION
Consult with local safety agencies and their
requirements when designing a machine control link,
interface, and all control elements that affect safety.
• Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in
death or serious injury.
3b. Care should be taken to ensure that all mounted
hardware cannot become detached during the
operational lifetime in the intended application
4.
Loosen the screws on the switch’s cover and remove it.
5.
For switches where the cable gland is not provided, use a
gland rated Type 1 or higher to maintain the integrity of the
enclosure-type rating.
6.
Loosen gland cover, then torque the gland to the switch’s
cover using 1 Nm to 2 Nm [8.85 in-lb to 17.7 in-lb] of force.
Ensure the o-ring was assembled between the gland and
the switch cover.
7.
Use copper conductors rated at 75°C or higher. Thread the
cable through the gland cover and gland, then press the
wire into the contact block’s terminals.
8.
Refer to circuit diagram on switch’s cover. Insert the
terminals into the switch and then fully fix terminal screws:
0,5 Nm to 0,6 Nm [4.42 in-lb to 5.31 in-lb].
9.
Perform functional tests. After wiring, use a voltmeter to
ensure when the switch is operated (turned off and on) that
a change of state occurs.
•
Multiple language versions of installation instructions and other documents are available on Honeywell’s website. To access:
1.
2.
Go to http://sensing.honeywell.com/limitswitches
Select the product’s instructions from the installation
instruction section
INSTALLATION INFORMATION
1.
2.
Refer to
- Page 4 for switch mounting torque
- Page 5 for specifications
For mounting, note mounting dimension drawing for hole
locations (Figure 5).
Figure 1. SZL-VL Wiring View
gland cover
gland
switch cover
cable
terminal screw
switch base
Sensing and Internet of Things
9a. Confirm the normal closed contacts open when
actuator is pushed or lever is rotated.
9b. Confirm the normal open contacts closed when
actuator is pushed or lever is rotated.
10. Reassemble up cover, and torque it: 0,5 Nm to 0,6 Nm
[4.42 in-lb to 5.31 in-lb] using M3 screw.
11. Reassemble gland cover (0,8 Nm to 1,5 Nm torque)
o ring
grounding screw
Mount switch
MICRO SWITCH SZL-VL-S Miniature Limit Switch
ISSUE C
32328692
Figure 2. SZL-VL Exploded View
Cross-type (combo head)
screw with black finish
Torx® screws
(do not remove)
Adjustable reference mark
Actuator head (can be rotated
in 90° increments)
Stainless steel arm
O-ring seal
Electrical rating up to 380 Vac/0.5 A
Large cavity for easy wiring
Contact block
Dual-purpose mounting and grounding screw
Seal gasket: IP67
M12 conduit connection
2 sensing.honeywell.com
MICRO SWITCH SZL-VL-S Miniature Limit Switch
SIDE ROTARY HEAD DIRECTION CHANGE
Figure 3. Rotary Head Direction Change
ISSUE C
32328692
PLUNGER HEAD DIRECTION CHANGE
Figure 4. Plunger Head Direction Change
cross type screw/
combo-head screw
pin
cross-type (combo-head)
screw (black)
head neck slot
head neck slot
contact
block
1.
2.
3.
4.
5.
6.
clip
90°
clip
contact
block
The heads of side-rotary SZL-VL-S
limit switches may be rotated in 90°
increments. The operating head may
be set to any of four positions.
Disassemble the head’s cross-type (combo-head) screw.
Do not loosen or remove the other two Torx® screws.
Remove the switch cover by loosening the three (3) cover
screws.
Lift slightly on the switch head.
Rotate the switch head to the desired direction ensuring
the clip is still engaged with the head-neck slot.
If clip dislodges, return the clip to its location above the
contact blow and below the top of the switch housing by
fully re-inserting the clip.
Re-insert the cross-type (combo head) screw to reassemble the switch’s head, 0,4 Nm to 0,5 Nm [3.54 in-lb
to 4.42 in-lb].
1.
2.
3.
4.
5.
Remove the switch cover by loosening the three (3) cover
screws.
Use flat screw driver to lift up the clip.
Rotate the switch head to the desired direction.
Properly align the two pins on the switch’s head into the
holes on the switch’s body.
Return the clip to its location above the contact blow and
below the top of the switch housing by fully re-inserting the
clip.
Sensing and Internet of Things
3
MICRO SWITCH SZL-VL-S Miniature Limit Switch
Figure 5. Installation Screw Identification and Torque
32328692
Table 1. Installation Screw and Torque
3
Description
(see Figure 5)
Screw type
Installation torque
1
Installation screw
for cover
M3 x 21
machine screw
0,5 Nm to 0,6 Nm
[4.42 in-lb to 5.31 in-lb]
2
Installation screw
for cover
M3 x 5 machine
screw
0,5 Nm to 0,6 Nm
[4.42 in-lb to 5.31 in-lb]
3
Installation screw
for head
M2.5 screw
0,4 Nm to 0,5 Nm
[3.54 in-lb to 4.42 in-lb]
4
Installation screw
for fixed lever
M4 machine screw
0,65 Nm to 0,85 Nm
[5.8 in-lb to 7.5 in-lb]
5
Installation screw
for adjustable lever
M4 machine screw
2,5 Nm to 3 Nm
[22.1 in-lb to 26.6 in-lb]
6
Terminal screw
M3 x 6 screw with
assembled lock
washer
0,5 Nm to 0,6 Nm
[4.42 in-lb to 5.31 in-lb]
7
Grounding screw
M3 x 5.5
machine screw
0,5 Nm to 0,6 Nm
[4.42 in-lb to 5.31 in-lb]
8
Installation screw
for product
M4 machine screw
2,5 Nm to 3 Nm
[22.1 in-lb to 26.6 in-lb]
Screw
5
4
2
6
7
8
1
4 sensing.honeywell.com
ISSUE C
MICRO SWITCH SZL-VL-S Miniature Limit Switch
ISSUE C
32328692
Table 2. Performance Specifications
Characteristic
Parameter
Description
Approvals
Miniature industrial limit switch
CCC, CE, cULus
Die-cast metal housing with glass-filled, flame-retardant thermoplastic cover
UL 94 flame spread testing: V-0 rated
Conduit entry or cable gland
Snap-action (all versions)
Positive-opening contacts (side-rotary version only)
Silver alloy
AC-15 A300 (380 Vac/0.5 A)
DC-13 Q300 (220 Vdc/0.05 A)
10 A/250 Vac (EN 60947-5-1)
< 25 mOhm
>100 MOhm at 500 Vdc
2500 Vdc
1890 Vac for metal housing, 1890 Vac between all terminals to enclosure after durability test
< 10 mA
3
IP67
-20°C to 70°C [-4°F to 158°F] (with no icing)
95 %RH
30 G, conforming to IEC 60068-2-27
10 G, 10 Hz to 55 Hz displacement amplitude 0,75 mm, conforming to IEC 60068-2-6 (wobble excluded)
10M cycles @ 120 cpm max.
0.5M cycles @ 30 cpm max. under the rated resistance load
0,05 mm/s to 2 m/s (based on pin plunger limit switch)
Mechanical: 120 ops/min; Electrical: 30 ops/min
120 g to 150 g
Housing material
Electrical connection
Contact design
Contact material
Electrical ratings
Thermal current (Ith)
Initial contact resistance
Insulation resistance
Impulse voltage
Dielectric voltage
Leakage current
Pollution degree
Environmental sealing
Operating temperature
Humidity
Shock
Vibration
MCTF (Mechanical life)
MCTF (Electrical life)
Operating speed
Operating frequency
Weight
Figure 6. Circuitry
Figure 7. Mounting Holes
NO 3
4 NO
NC 1
2 NC
Figure 8. Wiring
14,6
[0.57]
4X M5
56
[2.21]
16
[0.63]
21
[0.83]
Sensing and Internet of Things
5
MICRO SWITCH SZL-VL-S Miniature Limit Switch
32328692
ISSUE C
70°
40°
Side rotary, fixed
lever
Steel roller,
Ø18 x 6,5
[Ø0.71 x 0.25]
Steel, R30
0°
25°
15°
70°
40°
18 Ncm
[1.59
in-lb]
SZL-VL-S-B-N-M
Side rotary,
adjustable lever
Nylon roller,
Ø18 x 6,5
Steel, R30 to R70
[Ø0.71 x 0.25]
0°
25°
15°
70°
40°
18 Ncm
[1.59
in-lb]
SZL-VL-S-J-N-M
Side rotary,
adjustable lever
Steel roller,
Ø18 x 6,5
Steel, R30 to R70
[Ø0.71 x 0.25]
0°
25°
15°
70°
40°
18 Ncm
[1.59
in-lb]
0°
25°
15°
70°
40°
18 Ncm
[1.59
in-lb]
27 ±0,8
[1.04
±0.03]*
n/a
9N
[2.02 lb]
Side rotary,
SZL-VL-S-C-N-M
adjustable rod
–
Metal rod,
Ø2,5 mm [0.1 in],
125 mm
[4.92 in] long
SZL-VL-S-D-N-M Top pin plunger
Metal pin,
Ø6,6 [0.26]
–
SZL-VL-S-H-N-M
Top roller
plunger
Steel roller,
Ø12,5 x 3,8
[Ø0.5 x 0.15]
SZL-VL-S-E-N-M
Top cross roller
plunger
SZL-VL-S-F-N-M
Wobble, coil
spring and
nylon rod
1
–
38,5 ±0,8
[1.5
±0.03]*
2
1,5
3,5
[0.08] [0.06] [0.14]
Steel roller,
Ø12,5 x 3,8
[Ø0.5 x 0.15]
–
38,5 ±0,8
[1.5
±0.03]*
2
1,5
3,5
[0.08] [0.06] [0.14]
–
Ø5,8 mm
[0.23 in] coil
spring with
plastic rod
0°
Wobble, coil
SZL-VL-S-G-N-M spring and
metal wire
–
Wobble, coil
spring
–
SZL-VL-S-K-N-M
Ø5,8 mm [0.23
in] coil spring with
Ø1,2 mm [0.05
in] metal wire
0°
Ø5,8 mm
[0.23 in] coil
spring
0°
Specifications are exactly the same for the -N and -M with cable gland option
* (from the center of the mounting hole)
6 sensing.honeywell.com
2
1,5
3,5
[0.08] [0.06] [0.14]
n/a
9N
[2.02 lb]
n/a
9N
[2.02 lb]
n/a
2N
[0.45lb]
25° 40°
max.
1-2
3-4
3-4
1-2
0°
2 mm
max.
1-2
3-4
3-4
1-2
0
30°
30°
30°
–
–
–
20°
20°
20°
n/a
n/a
2N
[0.45lb]
2N
[0.45lb]
95°
max.
10°
max.
0,5 mm
max.
5,5 mm
max.
30°
max.
1-2
3-4
3-4
1-2
SZL-VL-S-I-N-M
15°
Bar chart
Operating force/torque
(max.)
25°
Lever
Overtravel min.
mm [in]
0°
Roller/pin
plunger
Differential travel max.
mm [in]
Steel, R30
18 Ncm
[1.59
in-lb]
Actuator
Pretravel max.
mm [in]
Nylon roller,
Side rotary, fixed
Ø18 x 6,5
SZL-VL-S-A-N-M
lever
[Ø0.71 x 0.25]
Catalog listing1
Free position
Min. travel to achieve
positive opening
Table 3. Specifications
0°
10°
max.
55°
max.
MICRO SWITCH SZL-VL-S Miniature Limit Switch
Dimensional Drawings • mm [in]
Figure 9. SZL-VL Side Rotary Limit Switch (Fixed Lever)
Ø 18 [0.7] roller
PT
Figure 10. SZL-VL Side Rotary Limit Switch (Adjust. Lever)
36
[1.41]
6,3 [0.25]
Adjustable length
of arm 30 to 70
[1.18 to 2.76]
20 [0.79]
64
[2.52]
56
[2.21]
63,5
[2.5]
2X M5
(P = 0.8)
tapped
mounting
holes
73,20 [2.88]
12,5 [0.49]
64
[2.52]
4
[0.16]
25,7
[1.01]
7,5 [0.30]
17 [0.67]
21
[0.83]
28,5
[1.12]
Figure 11. SZL-VL Side Rotary Limit Switch (Adjust. Rod)
25,7
[1.01]
Figure 12. SZL-VL Pin Plunger Limit Switch
38,1 [1.5]
M6 mounting rod
fastening screw
with hexagonal
holes
6,6 [0.26]
10 [0.39]
3,5 [0.14]
2X Ø 4,2
[0.17]
mounting
holes
27
[1.06]
3,5 [0.14]
18,5
[0.73]
125
[4.92]
2X M5
(P = 0.8)
tapped
mounting
holes
73,20
[2.88]
7,5 [0.30]
8,6
[0.34]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
2
[0.08]
17 [0.67]
21
[0.83]
28,5
[1.12]
Adjustable
length of
rod
30 to 118
[1.18 to 4.65]
M6 arm
fixing screw
18,5
[0.73]
2X Ø 4,2 [0.17]
mounting holes
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
4
[0.16]
Ø 2,5
[0.1]
rod
M4 arm
fixing screw
18,5
[0.73]
12,5 [0.49]
56
[2.21]
44
[1.74]
6,3 [0.25]
PT
M4 arm
fixing screw
2X Ø 4,2 [0.17]
mounting holes
49,5
[1.95]
Ø 18 [0.7] roller
R30
M4 arm
fixing out
32328692
20 [0.79]
5,2
[0.21]
ISSUE C
12,5 [0.49]
56
[2.21]
56
[2.21]
7,5 [0.30]
25,7
[1.01]
17 [0.67]
2X M5
(P = 0.8)
tapped
mounting
holes
73,20
[2.88]
2X M5
(P = 0.8)
tapped
mounting
holes
4
[0.16]
28,5
[1.12]
63,5
[2.5]
64
[2.52]
73,20
[2.88]
21
[0.83]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
20 [0.79]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
20 [0.79]
2X Ø 4,2
[0.17]
mounting
holes
21
[0.83]
28,5
[1.12]
7,5 [0.30]
4
[0.16]
17 [0.67]
25,7
[1.01]
Sensing and Internet of Things
7
MICRO SWITCH SZL-VL-S Miniature Limit Switch
Figure 13. SZL-VL Cross Roller Plunger Limit Switch
ISSUE C
32328692
Figure 14. SZL-VL Roller Plunger Limit Switch
10 [0.39]
3,8 [0.15]
10 [0.39]
Ø 12,7
[0.50]
3,8 [0.15]
Ø 12,7
[0.50]
15 [0.59]
38,5 [1.52]
2X Ø 4,2
[0.17]
mounting
holes
38,5 [1.52]
2X Ø 4,2
[0.17]
mounting
holes
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
63,5
[2.5]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
56
[2.21]
64
[2.52]
63,5
[2.5]
56
[2.21]
64
[2.52]
2X M5
(P = 0.8)
tapped
mounting
holes
73,20
[2.88]
4
[0.16]
73,20
[2.88]
7,5 [0.30]
21
[0.83]
17 [0.67]
28,5
[1.12]
4
[0.16]
21
[0.83]
25,7
[1.01]
2X M5
(P = 0.8)
tapped
mounting
holes
7,5 [0.30]
17 [0.67]
25,7
[1.01]
28,5
[1.12]
Figure 15. SZL-VL Coil Wobble (Plastic Tip) Limit Switch
Figure 16. SZL-VL Coil Wobble (Wire Tip) Limit Switch
10,1
[0.4]
PT
10,1
[0.4]
30 [1.18]
PT
Ø 5,8
[0.23]
100
[3.9]
Ø 1,2
[0.05]
30 [1.18]
Ø 5,8
[0.23]
100
[3.9]
20
[0.79]
20
[0.79]
2X Ø 4,2
[0.17]
mounting
holes
2X Ø 4,2
[0.17]
mounting
holes
56
[2.2]
21
[0.83]
28,5
[1.12]
8 sensing.honeywell.com
73,20
[2.88]
2X M5
(P = 0.8)
tapped
mounting
holes
7,5 [0.30]
4
[0.16]
17 [0.67]
25,7
[1.01]
64
[2.52]
56
[2.2]
64
[2.52]
73,20
[2.88]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
20 [0.79]
20 [0.79]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
21
[0.83]
28,5
[1.12]
2X M5
(P = 0.8)
tapped
mounting
holes
4
[0.16]
7,5 [0.30]
17 [0.67]
25,7
[1.01]
MICRO SWITCH SZL-VL-S Miniature Limit Switch
Figure 17. SZL-VL Coil Wobble Limit Switch
ISSUE C
32328692
Figure 18. SZL-VL M12 Cable Gland (A1-LSC-F)
10,1
[0.4]
8
[0.31]
5,2
[0.20]
Cable outer diameter
Ø 4 to Ø 6,5
[Ø 0.16 to Ø 0.26]
Ø 16,8
[0.66]
30 [1.18]
M12X1.5
Ø 5,8
[0.23]
100
[3.9]
12
[0.47]
2X Ø 4,2
[0.17]
mounting
holes
20
[0.79]
2X M5
(P = 0.8)
tapped
7,0 [0.28]
depth
mounting
holes
20 [0.79]
10,5 [0.41]
56
[2.2]
64
[2.52]
2X M5
(P = 0.8)
tapped
mounting
holes
73,20
[2.88]
21
[0.83]
28,5
[1.12]
15
[0.59]
4
[0.16]
7,5 [0.30]
17 [0.67]
25,7
[1.01]
INSTALLATION INFORMATION
Actuator should use bevel block for fixed lever, adjustable lever and top roller plunger
Figure 19. SZL-VL Side Rotary with Bevel Block: Suggested Actuator
Sensing and Internet of Things
9
MICRO SWITCH SZL-VL-S Miniature Limit Switch
ISSUE C
32328692
INSTALLATION INFORMATION, CONTINUED
Actuator should use bevel block for fixed lever, adjustable lever and top roller plunger
Figure 20. SZL-VL Side Rotary with Bevel Block: Suggested Actuator
30°
When wiring, leave enough space for cable.
Figure 21. SZL-VL Side Rotary with Bevel Block: Suggested Cable
10 sensing.honeywell.com
MICRO SWITCH SZL-VL-S Miniature Limit Switch
ISSUE C
32328692
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or
consult your local sales office for specific warranty details.
If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its
option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for a
particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
For more information
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or the
nearest Authorized Distributor, visit
sensing.honeywell.com or call:
Asia Pacific
+65 6355-2828
Europe +44 1698 481481
USA/Canada
+1-800-537-6945
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com
Torx® is a registered trademarks of Acument Intellectual Properties, LLC
32328692-C-EN | C | 03/19
© 2019 Honeywell International Inc. All rights reserved.