Honeywell 50099568510 Series Mechanical Encoders Installation Instruction

Honeywell 50099568510 Series Mechanical Encoders Installation Instruction
Installation Instructions for the
510 Series Mechanical Encoders
GENERAL INFORMATION
Issue A
50099568
The “L” channel leads the “R” channel by 90º electrically in the
clockwise position. This series has continuous electrical travel and
has a rotational life of more than 100,000 shaft rotations with a
positive detent feel.
The 510 Series products are manually operated, rotary encoders
that supply a two-bit gray code output for relative reference
applications or a four-bit gray code output for absolute electrical
reference applications. They combine the feel of a rotary switch with
a digital output.
These small encoders are commonly used in limited-space, panelmounted applications where the need for costly, front-panel displays
can be completely eliminated. Digital gray code outputs may
eliminate the need for analog/digital converters.
Table 1. Electrical Specifications
Parameter
Characteristic
Output
Closed circuit resistance
Open circuit resistance
Termination B
2-bit
Termination B
4-bit
Termination C
2-bit
Termination C
4-bit
2-bit gray code,
channel L leads
channel R by 90º
electrically CW
4-bit gray code,
absolute electrical
position output
2-bit gray code,
channel L leads
channel R by 90º
electrically CW
4-bit gray code,
absolute electrical
position output
Termination D
2-bit gray code,
channel L leads
channel R by 90º
electrically CW
5 Ohm max.
100 kOhm min.
Contact rating
250 mA at 28 Vdc max.
Switching loads:
14 Vdc
115 Vac
150 mA
1.5 mA
Dielectric
1000 Vac at sea level
Rotational life
100,000 cycles at rated load, typ.
Electrical travel
360º/continuous
Table 2. Mechanical Specifications
Parameter
Characteristic
Termination B
2-bit
Termination B
4-bit
Mechanical travel
Detent positions
Termination C
2-bit
Termination C
4-bit
Termination D
16
16
360º/continuous
16, 24, or 36
1
16
16, 24, or 361
Actuation torque
21 mN m to 23 mN m [3 in-oz to 5 in-oz]
Operating speed
50 rpm max.
Termination type
Material:
housing, bushing, shaft
terminals
PCB
See Order Guide Tables on pp. 3-5.
Sensing and Control
formed, C-30 type
straight, B-110 type
glass-reinforced thermoplastic
tin-plated brass
FR4
formed, C-30 type
with mounting
bracket
510 Series Mechanical Encoders
ISSUE A
50099568
Table 3. Environmental Specifications
Parameter
Characteristic
Termination B
2 bit
Termination B
4 bit
Termination C
2 bit
Termination C
4 bit
Operating temperature
-40 ºC to 105 ºC [-40 ºF to 221 ºF]
Storage temperature
-55 ºC to 120 ºC [-67 ºF to 248 ºF]
Sealing
Termination D
Controls are not sealed for board washing. Consult Honeywell for details.
Figure 1. Output Information
Incremental Output Graphs (Clockwise Rotation)
1 = 20
Position 1 G 2
G = Ground
1
2 = 21
2
3
Closed
4
Open
5
6
7
8
9
10
11
12
13
14
2-bit,
15
16 detent
16
17
18
19
20
21
22
2-bit,
23
24 detent
24
25
26
27
28
29
30
31
32
33
34
2-bit,
35
36 detent
36
2
Honeywell Sensing and Control
Channel Graph
1
R
0
1
Position 1 4 2 G 8
1 = 20
4 = 22
1
2
2 = 21
3
G = Ground
4
8 = 23
5
Closed
6
Open
7
8
9
10
11
12
13
14
15
4-bit,
16
16 detent
L
0
CW
¼ Cycle per detent
510 Series Mechanical Encoders
ISSUE A
50099568
Table 510-A Order Guide
Electrical
Mechanical
Number of Bits
Detent Positions
510E1A48F204PB
2
510E1A48F206PB
510E1A48F209PB
Catalog Listing
RoHS Compliant
Mounting Hardware
16
yes
none
2
24
yes
none
2
36
yes
none
Dimensional Drawing (For reference only: mm [in].)
Shown with shaft in position 1
21,08
[0.830]
8,13
[0.320]
19,1
[0.752]
8,71
[0.343]
6,35
[0.250]
9,53
[0.375]
ø6,27
[0.247]
21,08
[0.830]
5,54
[0.218]
15,62
[0.615]
3/8-32 UNEF-2A
Mounting surface
90°
6,35
[0.250]
2X 2,54
[0.100]
Table 510-B Order Guide
Catalog Listing
510E1A48F416PB
Electrical
Mechanical
Number of Bits
Detent Positions
4
16
RoHS Compliant
Mounting Hardware
yes
none
Dimensional Drawing (For reference only: mm [in].)
Shown with shaft in position 1
21,08
[0.830]
8,13
[0.320]
19,1
[0.752]
ø6,27
[0.247]
8,71
[0.343]
6,35
[0.250]
9,53
[0.375]
21,08
[0.830]
5,54
[0.218]
15,62
[0.615]
3/8-32 UNEF-2A
Mounting surface
90°
8,13
[0.320]
2X 2,54
[0.100]
Honeywell Sensing and Control
3
510 Series Mechanical Encoders
ISSUE A
50099568
Table 510-C Order Guide
Electrical
Mechanical
Number of Bits
Detent Positions
510E1A48F204PC
2
510E1A48F206PC
510E1A48F209PC
Catalog Listing
RoHS Compliant
Mounting Hardware
16
yes
none
2
24
yes
none
2
36
yes
none
Dimensional Drawing (For reference only: mm [in].)
Shown with shaft in position 1
19,1
[0.752]
6,35
[0.250]
21,08
[0.830]
8,1
[0.32]
ø6,27
8,71
[0.343]
9,53
[0.375]
[0.247]
21,08
[0.830]
90°
5,54
[0.218] 3/8-32 UNEF-2A
Mounting surface
15,62
[0.615]
3,97, Typ.
[0.156]
2X 2,54
[0.100]
Table 510-D Order Guide
Catalog Listing
Electrical
Mechanical
Number of Bits
Detent Positions
4
16
510E1A48F416PC
RoHS Compliant
Mounting Hardware
yes
none
Dimensional Drawing (For reference only: mm [in].)
Shown with shaft in position 1
21,08
[0.830]
8,13
[0.320]
19,1
[0.752]
6,35
[0.250]
ø6,27
[0.247]
8,71
[0.343]
9,53
[0.375]
21,08
[0.830]
5,54
[0.218]
90°
3/8-32 UNEF-2A
Mounting surface
3,97
[0.156]
15,62
[0.615]
2X 2,54
[0.100]
4
Honeywell Sensing and Control
510 Series Mechanical Encoders
ISSUE A
50099568
Table 510-E Order Guide
Catalog Listing
510E1A48F209PC
Electrical
Mechanical
Number of Bits
Detent Positions
2
36
RoHS Compliant
Mounting Hardware
yes
mounting bracket
Dimensional Drawing (For reference only: mm [in].)
Shown with shaft in position 1
21,08
[0.830]
8,13
[0.320]
18,59
[0.732]
ø6,27
5,84
[0.230]
9,22
[0.363]
3.73
[0.147]
[0.247]
21,08
[0.830]
15,32
[0.603]
5,54
[0.218]
90°
3/8-32 UNEF-2A
Mounting surface
15,62
[0.615]
15,88
[0.625]
2X 2,54
[0.100]
Figure 2. 510BKT Mounting Bracket (available separately)
Honeywell Sensing and Control
5
510 Series Mechanical Encoders
ISSUE A
50099568
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all warranties, expressed or implied, including
those of merchantability and fitness for a particular purpose.
In no event shall Honeywell be liable for consequential,
special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For application
assistance, current specifications, pricing or name of the nearest
Authorized Distributor, contact your local sales office or:
E-mail: info.sc@honeywell.com
Internet: sensing.honeywell.com
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
sensing.honeywell.com
50099568-1-EN IL50 GLO
XXXXXXX 2014
© 2014 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement