GENERAL SPECIFICATIONS
The ABP Series are piezoresistive silicon pressure sensors
offering a ratiometric analog or digital output for reading
pressure over the specified full scale pressure span and
temperature range. They are calibrated and temperature
compensated for sensor offset, sensitivity, temperature effects
and accuracy errors (which include non-linearity, repeatability
and hysteresis) using an on-board Application Specific
Integrated Circuit (ASIC). Calibrated output values for pressure
are updated at approximately 1 kHz for analog and 2 kHz for
digital. All products are designed and manufactured according
to ISO 9001 standards.
• Dry gases option: The input port is limited to non-corrosive,
non-ionic media (e.g., dry air, gases) and should not be
exposed to condensation. The gases are limited to media
compatible with high temperature polyamide, silicone,
alumina ceramic, silicon, gold, and glass.
CLEANING
CAUTION
IMPROPER CLEANING
Avoid cleaning the sensor; however, if it must be cleaned
ensure cleaning fluids, such as appropriate alcohols
or fluorinated solvents, are used based on the type of
contaminants to be removed. Do not immerse the sensor.
Failure to comply with these instructions may result in
product damage.
TABLE 1. ABSOLUTE MAXIMUM RATINGS1
CHARACTERISTIC
MIN.
MAX.
UNIT
Supply voltage (Vsupply)
-0.3
6.0
Vdc
Voltage on any pin
-0.3
Vsupply + 0.3
V
Digital interface clock frequency:
I2C
SPI
100
50
400
800
kHz
2
—
kV
-40 [-40]
85 [185]
°C [°F]
ESD susceptibility (human body model)
Storage temperature
Soldering time and temperature:
lead solder temperature (DIP)
peak reflow temperature (Leadless SMT, SMT)
4 s max. at 250°C [482°F]
15 s max. at 250°C [482°F]
Absolute maximum ratings are the extreme limits the device will withstand without damage.
1
TABLE 2. ENVIRONMENTAL SPECIFICATIONS
CHARACTERISTIC
PARAMETER
Humidity:
all external surfaces
internal surfaces of Liquid Media Option (T, V, F, G)
internal surfaces of Dry Gases Option (N, D)
Vibration
0 %RH to 95 %RH, non-condensing
0 %RH to 100 %RH, condensing
0 %RH to 95 %RH, non-condensing
15 g, 10 Hz to 2 kHz
Shock
100 g, 6 ms duration
Life
1 million pressure cycles minimum
J-STD-020-D.1 Moisture Sensitivity Level 1
(unlimited shelf life when stored at <30°C/85 %RH)
1
Solder reflow
Life may vary depending on specific application in which the sensor is used.
1
TABLE 3. WETTED MATERIALS1
COMPONENT
Ports and covers
Substrate
Adhesives
Electronic components
PRESSURE PORT 1 (P1)
DRY GAS OPTION
LIQUID MEDIA OPTION
high temperature polyamide
alumina ceramic
—
epoxy, silicone
epoxy, silicone gel
silicon, glass, solder, gold, aluminum
304 SST
Contact Honeywell Customer Service for detailed material information.
1
PRESSURE PORT 2 (P2)
alumina ceramic
epoxy, silicone
silicon
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
TABLE 4. SENSOR PRESSURE TYPES
PRESSURE TYPE
Gage
Differential
DESCRIPTION
Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure.
Output is proportional to the difference between the pressures applied to each port (Port 1 – Port 2).
TABLE 5. OPERATING SPECIFICATIONS
MIN.
ANALOG
TYP.
MAX.
MIN.
DIGITAL
TYP.
MAX.
3.0
4.75
3.3
5.0
3.6
5.25
3.0
4.75
3.3
5.0
3.6
5.25
Vdc
—
—
—
-40 [-40]
2.1
2.7
—
—
2.8
3.8
—
85 [185]
—
—
—
-40 [-40]
3.1
3.7
1
—
3.9
4.6
10
85 [185]
mA
mA
uA
°C [°F]
0 [-32]
—
50 [122]
0 [-32]
—
50 [122]
°C [°F]
Temperature output option
—
—
—
—
±4
—
°C
Startup time (power up to data ready)
—
—
5
—
—
3
ms
Response time
Clipping limit:
upper
lower
I2C/SPI voltage level:
low
high
Pull up on SDA/MISO, SCL/SCLK, SS
—
1
—
—
0.46
—
ms
—
2.5
—
—
97.5
—
—
—
—
—
—
—
%Vsupply
—
—
—
—
—
—
—
—
—
—
80
1
—
—
—
20
—
—
%Vsupply
Total Error Band
—
—
±1.5
—
—
±1.5
%FSS8
Accuracy9
—
—
±0.25
—
—
±0.25
%FSS BFSL
—
0.03
—
—
—
—
±0.25
—
—
—
—
12
—
—
—
±0.25
—
—
%FSS
%FSS
bits
CHARACTERISTIC
Supply voltage (Vsupply):1, 2, 3
3.3 Vdc
5.0 Vdc
Supply current:
3.3 Vdc
5.0 Vdc
sleep mode option
Operating temperature range4
Compensated temperature range5
6
7
Long term stability (1000 hr, 25°C [77°F])
Output resolution
UNIT
kOhm
Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
3
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
5
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified performance
limits.
1
Temperature Output Option: Typical temperature output error over the compensated temperature range of 0°C to 50°C. Operation in Sleep Mode may affect
temperature output error depending on duty cycle.
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to
offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis.
8
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range.
9
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C [77°F]. Includes all
errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
6
7
TABLE 6. SENSOR OUTPUT AT SIGNIFICANT
PERCENTAGES (DIGITAL VERSIONS ONLY)
% OUTPUT
0
10
50
90
100
DIGITAL COUNTS
DECIMAL
HEX
0
0x0000
1638
0x0666
8192
0x2000
14746
0x399A
16383
0x3FFF
2 sensing.honeywell.com
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
TABLE 7. PRESSURE RANGE SPECIFICATIONS
PRESSURE
RANGE
PRESSURE RANGE
PMIN.
PMAX.
UNIT
PORT 1 (P1)
PORT 2 (P2)
COMMON
MODE
PRESSURE3
850
1400
1400
2000
2000
2000
4
8
8
16
3500
7000
7000
19000
19000
19000
19
19
19
19
1000
2500
2500
4000
4000
4000
8
16
16
19
10000
10000
10000
10000
10000
10000
17
17
17
17
—
—
—
—
—
—
—
—
—
—
—
—
3500
3500
3500
7000
19000
19000
19
19
19
19
19
19
—
—
—
—
—
—
—
—
—
—
—
—
5500
10000
10000
10000
10000
10000
17
17
17
17
17
17
85
140
140
200
200
200
400
800
800
1600
350
700
700
1900
1900
1900
1900
1900
1900
1900
100
250
250
400
400
400
800
1600
1600
1900
1000
1000
1000
1000
1000
1000
1700
1700
1700
1700
—
—
—
—
—
—
—
—
—
—
—
—
350
350
350
700
1900
1900
1900
1900
1900
1900
1900
1.9
—
—
—
—
—
—
—
—
—
—
—
—
550
1000
1000
1000
1000
1000
1700
1700
1700
1700
1700
1.7
OVERPRESSURE1
PORT 1 (P1)
PORT 2 (P2)
BURST PRESSURE2
1 psi to 150 psi
Differential
060MD
100MD
160MD
250MD
400MD
600MD
001BD
1.6BD
2.5BD
004BD
-60
-100
-160
-250
-400
-600
-1
-1.6
-2.5
-4.0
60
100
160
250
400
600
1
1.6
2.5
4.0
mbar
mbar
mbar
mbar
mbar
mbar
bar
bar
bar
bar
2000
4000
4000
10000
10000
17000
17
17
17
17
060MG
100MG
160MG
250MG
400MG
600MG
001BG
1.6BG
2.5BG
004BG
006BG
010BG
0
0
0
0
0
0
0
0
0
0
0
0
60
100
160
250
400
600
1
1.6
2.5
4
6
10
mbar
mbar
mbar
mbar
mbar
mbar
bar
bar
bar
bar
bar
bar
2000
2000
2000
4000
10000
10000
17
17
17
17
17
17
Gage
6 kPa to 1 MPa
Differential
006KD
010KD
016KD
025KD
040KD
060KD
100KD
160KD
250KD
400KD
-6
-10
-16
-25
-40
-60
-100
-160
-250
-400
6
10
16
25
40
60
100
160
250
400
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
200
400
400
1000
1000
1700
1700
1700
1700
1700
006KG
010KG
016KG
025KG
040KG
060KG
100KG
160KG
250KG
400KG
600KG
001GG
0
0
0
0
0
0
0
0
0
0
0
0
6
10
16
25
40
60
100
160
250
400
600
1
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
MPa
200
200
200
400
1000
1000
1700
1700
1700
1700
1700
1.7
Gage
Sensing and Internet of Things
3
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
TABLE 7. PRESSURE RANGE SPECIFICATIONS, CONTINUED
PRESSURE
RANGE
PRESSURE RANGE
PMIN.
PMAX.
UNIT
OVERPRESSURE1
PORT 1 (P1)
BURST PRESSURE2
PORT 1 (P1)
PORT 2 (P2)
COMMON
MODE
PRESSURE3
10
30
60
120
250
50
275
275
275
275
15
40
120
240
275
150
150
250
250
250
—
—
—
—
—
—
—
50
275
275
275
275
275
275
—
—
—
—
—
—
—
150
150
250
250
250
250
250
PORT 2 (P2)
1 psi to 150 psi
Differential
001PD
005PD
015PD
030PD
060PD
-1
-5
-15
-30
-60
1
5
15
30
60
psi
psi
psi
psi
psi
30
150
250
250
250
001PG
005PG
015PG
030PG
060PG
100PG
150PG
0
0
0
0
0
0
0
1
5
15
30
60
100
150
psi
psi
psi
psi
psi
psi
psi
30
150
250
250
250
250
250
Gage
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range.
Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the
operating temperature range.
2
Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be
expected to function after exposure to any pressure beyond the burst pressure.
3
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified
performance.
1
FIGURE 1. RECOMMENDED FILTER CAP
VSUPPLY
VSUPPLY
0.1 uF
VOUT*
0.001 uF*
Ground
*Analog output version only.
4 sensing.honeywell.com
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 2. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
DIP NN: No port
8,0
[0.32]
7,3
[0.29]
2,54 Typ.
[0.100]
4,0
[0.16]
4
5
3,23 Wet media
[0.127]
2,95 Dry media
[0.116]
6
6
5
4
1
2
3
2X 1,45
[0.057]
5,5
[0.22]
6,3
[0.25]
3
2
11,0
[0.43]
11,5
[0.45]
1,0
[0.04]
1
0,25 Typ.
[0.010]
8,6
[0.34]
3,81
[0.150]
6X 0,46
[0.018]
DIP AN: Single axial
barbed port
8,0
[0.32]
7,3
[0.29]
4,0
[0.16]
4
5
7,00
[0.276]
6
ø1,91
[0.075]
5,5
[0.22]
6,3
[0.25]
2,54 Typ.
[0.100]
3,63 Wet media
[0.143]
3,35 Dry media
[0.131]
3,56
[0.140]
ø2,74
[0.108]
6
5
2X 1,45
[0.057]
4
11,5
[0.45]
11,0
[0.43]
ø2,32
[0.091]
3
2
1
1,0
[0.04]
8,6
[0.34]
0,25 Typ.
[0.010]
1
2
3
3,81
[0.150]
6X 0,46
[0.018]
Sensing and Internet of Things
5
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 2. DIP PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)
DIP LN: Single axial
barbless port
8,0
[0.32]
7,3
[0.29]
4,0
[0.16]
4
5
2,54 Typ.
[0.100]
3,23 Wet media
[0.127]
2,95 Dry media
[0.116]
4,80
[0.189]
6
6
5
2X 1,45
[0.057]
4
5,5
[0.22]
6,3
[0.25]
3
2
ø5,00 2,68
[0.197] [0.106]
11,5
[0.45]
1,0
[0.04]
1
11,0
[0.43]
0,25 Typ.
[0.010]
8,6
[0.34]
1
2
3
6X 0,46
[0.018]
3,81
[0.150]
6X 0,46
[0.018]
DIP JN: Single radial
barbless port
0,7
[0.03
4
5
3,38 Wet media
[0.133]
3,10 Dry media
[0.122]
6
6
5
8,0
[0.32]
4,65
[0.183]
4
2.16
[0.085]
4,45
[0.175]
11,5
[0.45]
6,3
[0.25]
ø1,88
[0.074]
0,25 Typ.
[0.010]
3
7,3
[0.29]
3,81
[0.150]
6X 0,46
[0.018]
6 sensing.honeywell.com
11,0
[0.43]
2
1
1,0
[0.04]
8,6
[0.34]
1
2X 1,45
[0.057]
2
2,54 Typ.
[0.100]
3
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 2. DIP PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)
DIP JJ: Dual radial
barbless ports, same side
0,7
[0.03
4
2X 4,0
[0.16]
5
8,0
[0.32]
2,54 Typ.
[0.100]
3,38 Wet media
[0.133]
3,10 Dry media
[0.122]
2,82
[0.111]
6
6
Port 1
5
2X 1,47
[0.058]
4
2X 4,65
[0.183]
4,45
[0.175]
6,3
[0.25]
2,10
[0.083]
11,5
[0.45]
Port 1
2X ø1,88
[0.074]
11,0
[0.43]
Port 2
Port 2
3
7,3
[0.29]
2
1,0
[0.04]
1
4,45
[0.175]
1
0,25 Typ.
[0.010]
8,6
[0.34]
2
5,06 Wet media
[0.199]
4,78 Dry media
[0.188]
3
3,81
[0.150]
6X 0,46
[0.018]
DIP RN: Single radial
barbed port
4,0
[0.16]
4
ø1,60
[0.063]
0,5
[0.02]
5
8,0
[0.32]
2,54 Typ.
[0.100]
6
5
4
3,58 Wet media
[0.141]
3,30 Dry media
[0.129]
6
3,10
[0.122]
ø2,10
[0.083]
2,01
[0.079]
2X 1,47
[0.058]
4,55
[0.179]
6,3
[0.25]
ø1,75
[0.069]
11,5
[0.45]
11,0
[0.43]
0,25 Typ.
[0.010]
3
7,3
[0.29]
2
1
1
8,6
[0.34]
2
1,65
[0.065]
4,75
[0.187]
3
3,81
[0.150]
6X 0,46
[0.018]
DIP RR: Dual radial
barbed ports, same side
2X 4,0
[0.16]
4
5
3,58 Wet media
[0.141]
3,30 Dry media
[0.129]
6
2,78
[0.109]
8,0
[0.32]
2,54 Typ.
[0.100]
2X 1.45
[0.057]
0,5
[0.02]
Port 1
6,3
[0.25]
1,90
[0.075]
6
5
2X 4,75
[0.187]
4
2X ø1,75
[0.069]
4,55
[0.179]
Port 1
Port 2
2X ø1,60
[0.063]
11,5 11,0
[0.45] [0.43]
4,55
[0.179]
Port 2
3
7,3
[0.29]
2
1
1.0
[0.04]
8,6
[0.34]
0,25 Typ.
[0.010]
1
2
3
2X ø2,10
[0.083]
4,76
[0.187]
3,81
[0.150]
6X 0,46
[0.018]
Sensing and Internet of Things
7
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 3. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
SMT NN: No port
7,3
[0.29]
4,0
[0.16]
4
5
6
8.0
[0.32]
0,25 Typ.
[0.010]
3,23 Wet media
[0.127]
2,95 Dry media
[0.116]
6
5
4
5,5
[0.22]
6,3
[0.25]
11,0
[0.43]
11,5
[0.45]
6X 1,28
[0.050]
3
SMT AN: Single axial
barbed port
2
1,0
[0.04]
1
7,3
[0.29]
4,0
[0.16]
4
6X 0,46
[0.018]
4,2
[0.17]
7,00
[0.276]
5
1
2
3
2X 1,45
[0.057]
2,54 Typ.
[0.100]
3,63 Wet media
[0.143]
3,35 Dry media
[0.131]
0,25 Typ.
[0.010]
6
3,56
[0.140]
6
8.0
[0.32]
5
4
5,5
[0.22]
6,3
[0.25]
[0.108]
[0.075]
SMT LN: Single axial
barbless port
2
4
1,0
[0.04]
1
7,3
[0.29]
4,0
[0.16]
5
6X 1,28
[0.050]
ø2,32
[0.091]
ø1,91
3
11,0
[0.43]
11,5
[0.45]
ø2,74
4,2
[0.17]
1
6X 0,46
[0.018]
3,23 Wet media
[0.127]
2,95 Dry media
[0.116]
0,25 Typ.
[0.010]
4,80
[0.189]
6
2
3
2,54 Typ.
[0.100]
6
8,0
[0.32]
5
2X 1,45
[0.057]
4
5,5
[0.22]
6,3
[0.25]
ø5,00 2,68
[0.197] [0.106]
11,0
[0.43]
11,5
[0.45]
6X 1,28
[0.050]
3
SMT JN: Single radial
barbless port
4,65
[0.183]
2
1,0
[0.04]
1
4,0
[0.16]
4
5
4,2
[0.17]
8,0
[0.32]
2,54 Typ.
[0.100]
6
5
3,38 Wet media
[0.133]
3,10 Dry media
[0.122]
6
0,7
[0.03]
1
6X 0,46
[0.018]
2
3
2,54 Typ.
[0.100]
2.16
[0.085]
1,47
[0.058]
4
4,45
[0.175]
6,3
[0.25]
1,88
[0.074]
3
8 sensing.honeywell.com
2
7,3
[0.29]
1
11,5
[0.45]
1,0
[0.04]
4,2
[0.17]
0,25 Typ.
[0.010]
11,0
[0.43]
6X 1,28 1
[0.050]
2
3
6X 0,46
[0.018]
2X 1,45
[0.057]
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 3. SMT PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)
SMT JJ: Dual radial
barbless ports, same
side
2X 4.65
[0.183]
4
5
6
8,0
[0.32]
2,54 Typ.
[0.100]
2,82
[0.111]
3,38 Wet media
[0.133]
3,10 Dry media
[0.122]
0,7
[0.03]
2X 4.0
[0.16]
2X 1,45
[0.057]
6
5
5,06 Wet media
[0.199]
4,78 Dry media
[0.188]
4
4.45
[0.175]
Port 1
2,10
[0.083]
6,3
[0.25]
Port 2
Port 1
2X 1,88
[0.074]
11,0
[0.43]
11,5
[0.45]
4,45
[0.175]
Port 2
3
2
7,3
[0.29]
1,0
[0.04]
1
4,2
[0.17]
0,25 Typ.
[0.010]
1
6X 1,28
[0.050]
2
3
6X 0,46
[0.018]
SMT RN: Single radial
barbed port
4,0
[0.16]
4
ø1,60
[0.063]
5
6
3,58 Wet media
[0.141]
3,30 Dry media
[0.129]
0,5
[0.02]
8,0
[0.32]
2,54 Typ.
[0.100]
2X 1,45
[0.057]
6
2,01
[0.079]
4,75
[0.187]
5
4
ø1,75
[0.069]
4,55
[0.179]
6,3
[0.25]
11,5
[0.45]
ø2,10
11,0
[0.43]
[0.083]
3
2
1,0
[0.04]
1
7,3
[0.29]
0,25 Typ.
[0.010]
4,2
[0.17]
6X 1,28 1
[0.050]
2
1.65
[0.065]
3
6X 0,46
[0.018]
SMT RR: Dual radial
barbed ports, both sides
2X 4.75
[0.187]
4
2X 4.0
[0.16]
5
6
3,10
[0.122]
1,90
[0.075]
2X 1,45
[0.057]
0,5
[0.02]
Port 1
6,3
[0.25]
8,0
[0.32]
2,54 Typ.
[0.100]
2,78
[0.109]
3,58 Wet media
[0.141]
3,30 Dry media
[0.129]
6
5
2X ø1,60
[0.063]
4,55
[0.179]
11,5
[0.45]
Port 1
2X ø2,10
[0.083]
11,0
[0.43]
Port 2
Port 2
3
2
7,3
[0.29]
1
1,0
[0.04]
4,2
[0.17]
0,25 Typ.
[0.010]
4,76
[0.187]
4
4,55
2X ø1,75 [0.179]
[0.069]
6X 1,28
[0.050]
1
2
3
6X 0,46
[0.018]
Sensing and Internet of Things
9
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
Issue D
32305127
FIGURE 4. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
Leadless SMT NN: No port
4.0
[0.16]
2
1
3,23 Wet media
[0.13]
3
3.5
[0.14]
5
2
1
3,00
[0.118]
6,3
[0.25]
6
3
1,0
[0.04]
2,95 Dry media
[0.12]
7,0
6X 1,25 [0.28]
[0.049]
4
2,5 Typ.
[0.10]
4
7,3
[0.29]
5
6
8,0
[0.32]
1,5
[0.06]
Leadless SMT AN: Single
axial barbed port
4.0
[0.16]
2
1
1,0
[0.04]
7,0
[0.28]
3
3,56
[0.140]
3.5
[0.14]
3,63 Wet media
[0.14]
3,35 Dry media
[0.13]
6,3 ø2,74
[0.25] [0.108]
5
2
7,0
6X 1,25 [0.28]
[0.049]
ø2,32
[0.091]
4
2,5 Typ.
[0.10]
4
7,3
[0.29]
1
3,00
[0.118]
ø1,91
[0.075]
6
3
5
6
8,0
[0.32]
1,5
[0.06]
Leadless SMT LN: Single
axial barbless port
1
4.0
[0.16]
2
3,23 Wet media
[0.13]
3
3.5
[0.14]
6,3
[0.25]
6
5
7,3
[0.29]
1,0
[0.04]
2,95 Dry media
[0.12]
4
ø2,68
[0.106] Port 1
ø5,0
[0.20]
4,1
[0.16]
3
2
1
3,00
[0.118]
7,0
6X 1,25 [0.28]
[0.049]
4
2,5 Typ.
[0.10]
0,7
[0.03]
5
8,0
[0.32]
6
1,5
[0.06]
TABLE 8. PINOUTS
OUTPUT TYPE
I2C
SPI
analog
10 sensing.honeywell.com
PIN 1
GND
GND
GND
PIN 2
Vsupply
Vsupply
NC
PIN 3
INT
SS
Vout
PIN 4
NC
NC
NC
PIN 5
SDA
MISO
NC
PIN 6
SCL
SCLK
Vsupply
BASIC AMPLIFIED BOARD MOUNT PRESSURE SENSORS,
ABP SERIES
FIGURE 5. RECOMMENDED PCB LAYOUTS
DIP
2
3
6X ø0.73
[0.029]
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
6,00
[0.236]
11,25
[0.443]
11,0
[0.433]
5,00
[0.197]
5
6
SMT
4
2,54
[0.1]
8,00
[0.315]
2,73
[0.107]
Gage reference hole: do not plug
0,65
[0.026]
2
1
3
6,00
[0.236]
8,85
[0.348]
11,00
[0.433]
12,35
[0.315]
5,00
[0.197]
6
5
4
Leadless SMT
1,30
[0.051]
3,00
[0.118]
2,73
[0.107]
1
2
3
6
5
4
2,50
[0.098]
8,00
[0.315]
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgment or
consult your local sales office for specific warranty details.
If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its
option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for a
particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
Gage reference hole: do not plug
4,00
[0.157]
Failure to comply with these instructions could result in
death or serious injury.
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
2,54
[0.1]
8,00
[0.315]
2,73
[0.107]
m WARNING
PERSONAL INJURY
Gage reference hole: do not plug
1
7,00
3,25 [0.28]
0.128]
8,00
[0.315]
Honeywell serves its customers through a worldwide network
of sales offices and distributors. For application assistance,
current specifications, pricing or name of the nearest
Authorized Distributor, contact your local sales office or:
E-mail: info.sc@honeywell.com
Internet: sensing.honeywell.com
Phone and Fax:
USA/Canada
+1-800-537-6945
International
+1-815-235-6847; +1-815-235-6545 Fax
Honeywell
Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywell.com
Issue D
32305127
32305127-D-EN | D | 07/19
© 2019 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising