Installation Instructions for the

SS345PT/SS445P Unipolar Hall-effect Digital

ISSUE 2 50048012

Position Sensor ICs with Built-in Pull-up Resistor

Table 1. Absolute Maximum Ratings 1 GENERAL INFORMATION

CAUTION

ELECTROSTATIC DISCHARGE DAMAGE

This component is sensitive to electrostatic discharge (ESD). Take normal ESD precautions in handling this product to prevent ESD induced damage and/or degradation.

Failure to comply with these instructions may result in product damage. SOLDERING/ASSEMBLY

CAUTION

IMPROPER SOLDERING

case. Ensure leads are adequately supported during any forming/ shearing operation so that they are not stressed inside the plastic Limit exposure to high temperatures. Do not wave solder the SS345PT.

Failure to comply with these instructions may result in product damage.

SS345PT

: Use an infrared reflow process with temperatures of 245 °C [473 °F] peak for 10 s max.

SS445P:

PC board wave soldering temperature is 250 °C to 260 °C [482 °F to 500 °F] peak for 3 s max.

Figure 1. Current Sinking Output Block Diagram Characteristic

Supply voltage Applied output

Min.

-0.5 -0.5

Typ.

– –

Max.

7.0 7.0

Unit

Vdc Vdc voltage Output current Magnetic flux – – – – 8.0 no limit mA Gauss

Note 1:

Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings.

NOTICE

The magnetic field strength (Gauss) required to cause the switch to change state (operate and release) will be as specified in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a uniform magnetic field.

Figure 2. Typical Performance Characteristics Table 1. Specifications (At 2.7 to 7 Vdc supply, 4 mA load, TA = -40 °C to 150 °C [-40 °F to 302 °F]) Characteristic

Supply voltage Supply current Output current Vsat Output leakage current Output rise and fall time Thermal resistance: SS345PT SS445P Operate Release Differential Operating temperature Storage temperature

Condition

-40 °C to 150 °C [-40 °F to 302 °F] Gauss < 25 , Vs = 5 V, 25 °C [77 °F] -40 °C to 150 °C [-40 °F to 302 °F] – Gauss > 260 Gauss < 25 25 °C [77 °F] – -40 °C to 150 °C [-40 °F to 302 °F] -40 °C to 150 °C [-40 °F to 302 °F] -40 °C to 150 °C [-40 °F to 302 °F] – –

Minimum

2.7 – – – – – – – – 55 25 10 -40 [-40] -55 [-67]

Typical

5.0 5.5 – – – – – 303 233 180 105 75 – –

Maximum

7.0 – 14 4.0 0.4 10 1.5 – – 280 240 140 150 [302] 165 [329]

Unit

Vdc mA mA Vdc µA µs °C/W Gauss Gauss Gauss °C [°F] °C [°F]

Sensing and Control

SS345PT/SS445P

Figure 3. Mounting Dimensions (For reference only. mm/[in]) SS345PT

Issue 2

50048012

SS445P Figure 4. SS345PT Tape and Reel Dimensions (For reference only. mm/[in])

WARNING

PERSONAL INJURY

DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective.

warranties, expressed or implied, including those of or indirect damages.

our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

The foregoing is buyer’s sole remedy and is in lieu of all other merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special,

While we provide application assistance personally, through Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

SALES AND SERVICE

Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or:

E-mail:

[email protected]

Internet:

www.honeywell.com/sensing

Phone and Fax:

Asia Pacific Europe Latin America USA/Canada +65 6355-2828 +65 6445-3033 Fax +44 (0) 1698 481481 +44 (0) 1698 481676 Fax +1-305-805-8188 +1-305-883-8257 Fax +1-800-537-6945 +1-815-235-6847 +1-815-235 -6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422

www.honeywell.com/sensing

500480121-2-EN IL50 GLO Printed in USA July 2010 Copyright © 2010 Honeywell International Inc. All rights reserved.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Small size and low weight
  • High accuracy and reliability
  • Excellent temperature stability
  • Easy to install and use
  • Cost-effective solution

Related manuals

Frequently Answers and Questions

What is the maximum supply voltage for the SS345PT/SS445P sensors?
The maximum supply voltage for the SS345PT/SS445P sensors is 7.0 Vdc.
What is the maximum output current for the SS345PT/SS445P sensors?
The maximum output current for the SS345PT/SS445P sensors is 8.0 mA.
What is the minimum magnetic flux required to operate the SS345PT/SS445P sensors?
The minimum magnetic flux required to operate the SS345PT/SS445P sensors is less than 25 Gauss.
What is the maximum magnetic flux required to release the SS345PT/SS445P sensors?
The maximum magnetic flux required to release the SS345PT/SS445P sensors is greater than 260 Gauss.
What is the operating temperature range for the SS345PT/SS445P sensors?
The operating temperature range for the SS345PT/SS445P sensors is -40 °C to 150 °C.