Table 1. Absolute Maximum Ratings1
GENERAL INFORMATION
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE
This component is sensitive to electrostatic discharge (ESD). Take
normal ESD precautions in handling this product to prevent ESDinduced damage and/or degradation.
Failure to comply with these instructions may result in product
damage.
Characteristic
Supply voltage
Applied output
voltage
Output current
Magnetic flux
Min.
-0.5
-0.5
Typ.
–
–
Max.
7.0
7.0
Unit
Vdc
Vdc
–
–
–
–
8.0
no limit
mA
Gauss
Note 1: Absolute maximum ratings are the extreme limits that the device will
withstand without damage to the device. However, the electrical and mechanical
characteristics are not guaranteed as the maximum limits (above recommended
operating conditions) are approached, nor will the device necessarily operate at
absolute maximum ratings.
NOTICE
The magnetic field strength (Gauss) required to cause the switch to
change state (operate and release) will be as specified in the
magnetic characteristics. To test the switch against the specified
magnetic characteristics, the switch must be placed in a uniform
magnetic field.
SOLDERING/ASSEMBLY
CAUTION
IMPROPER SOLDERING
Ensure leads are adequately supported during any forming/
shearing operation so that they are not stressed inside the plastic
case.
Limit exposure to high temperatures.
Do not wave solder the SS345PT.
Failure to comply with these instructions may result in product
damage.
SS345PT: Use an infrared reflow process with temperatures of 245 °C
[473 °F] peak for 10 s max.
SS445P: PC board wave soldering temperature is 250 °C to 260 °C
[482 °F to 500 °F] peak for 3 s max.
Figure 2. Typical Performance Characteristics
Figure 1. Current Sinking Output Block Diagram
Table 1. Specifications (At 2.7 to 7 Vdc supply, 4 mA load, TA = -40 °C to 150 °C [-40 °F to 302 °F])
Characteristic
Supply voltage
Supply current
Output current
Vsat
Output leakage current
Output rise and fall time
Thermal resistance:
SS345PT
SS445P
Operate
Release
Differential
Operating temperature
Storage temperature
Sensing and Control
Condition
Minimum
Typical
Maximum
Unit
-40 °C to 150 °C [-40 °F to 302 °F]
Gauss < 25 , Vs = 5 V, 25 °C [77 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
–
Gauss > 260
Gauss < 25
25 °C [77 °F]
2.7
–
–
–
–
–
–
5.0
5.5
–
–
–
–
–
7.0
–
14
4.0
0.4
10
1.5
Vdc
–
–
–
55
25
10
-40 [-40]
-55 [-67]
303
233
180
105
75
–
–
–
–
280
240
140
150 [302]
165 [329]
°C/W
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
–
–
mA
mA
Vdc
µA
µs
Gauss
Gauss
Gauss
°C [°F]
°C [°F]
SS345PT/SS445P
Issue 2
Figure 3. Mounting Dimensions (For reference only. mm/[in])
SS345PT
50048012
SS445P
Figure 4. SS345PT Tape and Reel Dimensions (For reference only. mm/[in])
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
500480121-2-EN IL50 GLO Printed in USA
July 2010
Copyright © 2010 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising