- Home
- Domestic appliances
- Large home appliances
- Water heaters & boilers
- Bradford White
- LG2DV50H503N
- Specification
advertisement
▼
Scroll to page 2
Light Duty Commercial Direct Vent Gas Water Heater Photo is of LG2DV50H503N FEATURING: The Direct Vent FVIR Defender Safety System® Models Feature: ■ Bradford White ICON System®—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter. A standard, off-the-shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. -- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and tighter temperature differential. -- Advanced Temperature Control System—Microprocessor controls burner operation for consistent and accurate water temperature levels up to 180°F (82°C). -- Intelligent Diagnostics—Exclusive multicolor LED light indicates operation status/ service required. ■ Closed Combustion—All air for combustion is taken directly from the outside. The co-axial vent pipe (pipe inside a pipe) draws combustion air in through the outer pipe and exhausts the products of combustion through the inner pipe. The co-axial vent pipe at the top of the unit can be rotated for venting flexibility. ■ Reinforced Seals—Seals surround the closed combustion chamber and the FVIR inner door, preventing the ignition of Flammable Vapors outside of the water heater. ■ Maintenance-Free—The vent piping and the closed combustion chamber with reinforced seals does not require regular cleaning under normal operating conditions. ■ Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner. ■ Factory-Installed Hydrojet® Total Performance System—Sediment reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank. ■ Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). ■ Cast Aluminum Air Intake Boot—A cast molded air intake boot provides exceptional installation durability. ■ Telescoping Solid Vent Kits—Multiple kits (see reverse side) allow up to 8ft. vertical and 8ft. horizontal vent lengths (horizontal termination only). ■ Flexible Vent Kit—The maximum vent length (horizontal and vertical) can be flexed to 100" (2540mm) (horizontal termination only). ■ Side Connections—3/4" (19mm) NPT tappings allow easy connections for space heating applications (Potable water only). ■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top of the tank, reducing heat loss. ■ Pedestal Base. ■ Water Connections—3/4" (19mm) NPT factory-installed true dielectric fittings. ■ Factory-Installed Heat Traps. ■ Protective Magnesium Anode Rod. ■ T&P Relief Valve—Installed. ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ NOx Emissions—Less than 40 ng/J. 3 or 5 Year Limited Tank Warranty / 1-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. 1705-A-0918 Light Duty Commercial Direct Vent Water Heater Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 78% Recovery Efficiency NATURAL GAS AND LIQUID PROPANE GAS Nominal Gal. Capacity Model Number U.S. Imp. Gal. Gal. LG2DV50H503N 48 Model Number LG2DV50H503N Model Number LG2DV50H503N Recovery at 100°F Rise* DOE Rated First LP Storage Hour Uniform Volume BTU/Hr. BTU/Hr. Rating Energy Input Input (Gal.) (Gal.) Factor 40 46 50,000 48,000 96 LP LP U.S. Imp. U.S. Imp. GPH GPH GPH GPH 47 0.64 39 45 LG2DV50H503N 38 D Floor to T&P Conn. in. E Floor to Gas Conn. in. F Floor to Top of Heater in. G Floor to Water Conn. in. H Depth 52 1/4 10 59 3/16 mm. C Vent Size mm. ID / OD D Floor to T&P Conn. mm. E Floor to Gas Conn. mm. 559 102 152 1327 254 A Floor to C/L of Vent Conn. in. B Jacket Dia. in. C Vent Size in. ID / OD 75 11/16 22 4 A Floor to C/L of Vent Conn. mm. B Jacket Dia. 1929 6 Nominal Liter Capacity Model Number 182 DOE Rated Storage Volume (Liters) LP kW kW Input Input 174 14.7 14.0 Recovery at 56°C Rise* First Hour Uniform Rating Energy (Liters) Factor 364 LP Liters/ Liters/ Hour Hour 0.64 178 170 in. J C/L of Water Conn. in. K Floor to Space Heating Inlet in. L Floor to Space Heating Outlet in. M Water Conn. NPT in. R Space Heating Conn. Size in. S Gas Conn. Size in. 617/16 33 5/16 11 15 3/4 52 1/4 34 / 34 / 12 / 217 F Floor to Top of Heater mm. G Floor to Water Conn. mm. H Depth K Floor to Space Heating Inlet mm. L Floor to Space Heating Outlet mm. M Water Conn. NPT mm. R Space Heating Conn. Size mm. S Gas Conn. Size mm. Approx. Shipping Weight mm. J C/L of Water Conn. mm. 1503 1561 846 279 400 1327 19 19 13 98 Approx. Shipping Weight lbs. kg. All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models change suffix from “3” to “5”. * Based on manufacturer’s rated recovery efficiency. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. Solid Vent Kit: Part No. 239-51286-00. Flexible Vent Kit: Part No. 239-51287-00. Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual. LG2DV50H503N Optional Telescoping Solid Vent Kits: Kit “F” Telescopes from 43⁄4" to 511⁄16" (121mm to 145mm) Kit “G” Telescopes from 61⁄2" to 93⁄16" (165mm to 233mm) Kit “H” Telescopes from 133⁄4" to 2311⁄16" (349mm to 602mm) Kit “I” Telescopes from 4913⁄16" to 9513⁄16" (1265mm to 2434mm) Part No. 239-42516-00 Part No. 239-42517-00 Part No. 239-42514-00 Part No. 239-42512-00 C C J M 197mm 197mm M R A A B G D&L F S H H R K E Telescoping Solid Vent Kit (Side View) Flexible Vent Kit (Side View) General: Meets NAECA Requirements. All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT (19mm). All gas connections 1⁄2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI Z21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. For field service, contact your professional installer or local Bradford White sales representative. Ambler, PA 1705-A-0918 Sales 800-523-2931 n Fax 215-641-1612 Technical Support 800-334-3393 n Email [email protected] Warranty 800-531-2111 n Email [email protected] International: Telephone 1-215-641-9400 n Email [email protected] / www.bradfordwhite.com ©2018, Bradford White Corporation. All rights reserved. Printed in U.S.A. N Floor to Air Intake in. 61 1/16 64 N Floor to Air Intake mm. 1551 1626
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project