Bradford White ULG2PDV50H503N Light Duty Ultra Low NOx Power Direct Vent Gas Spec Sheet

Add to my manuals
2 Pages

advertisement

Bradford White ULG2PDV50H503N Light Duty Ultra Low NOx Power Direct Vent Gas Spec Sheet | Manualzz
Light Duty Commercial Ultra Low NOx
Power Direct Vent Gas Water Heater
Photo is of
ULG2PDV50H503N
FEATURING:
The FVIR Eco-Defender Safety System® Models Feature:
■ Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices—Ensures
proper air to gas ratio for reduction of NOx generated by the combustion process.
■ Closed Combustion Venting System—Power Direct Vent closed combustion system
utilizes external air for combustion and exhausts directly to the outside through a separate
two-pipe system. The equivalent feet of intake venting cannot be greater than the
equivalent feet of exhaust venting.
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition system
eliminates the constant burning pilot. This results in savings of pilot gas during standby
periods (120 VAC).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and
tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor constantly monitors and
controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer composite
thermowell provides isolation between electric temperature sensor and surrounding
water. No need to drain the tank when removing gas valve.
■ Cast Aluminum Air Intake Boot—A cast molded air intake boot design provides
exceptional durability during installation and operation.
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable
vapors are detected. The sensor will also prevent operation if there is ongoing flammable
vapors burning inside the combustion chamber.
■ Factory-Installed Hydrojet® Total Performance System—Sediment reducing device
that also increases first hour rating of hot water while minimizing temperature build-up in
tank.
■ Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank
protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused
to the steel surface by firing at a temperature of over 1600°F (871°C).
■ Optional Concentric Vent Kit Termination—Concentric termination fitting provides for
only one exit opening through a wall or roof. (Subtract 10ft. (3m) for intake pipe and 10ft.
(3m) for exhaust pipe when calculating total vent length.)
■ Horizontal and Vertical Venting—PVC, ABS, or CPVC (Maximum equivalent vent length
for each pipe on reverse side).
■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top of the
tank, reducing heat loss. This results in less energy consumption, improved efficiencies,
and jacket rigidity.
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings.
■ Side Connections—3⁄4" (19mm) NPT tappings allow easy connections for space heating
applications (Potable water only).
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss
in piping and eliminates the potential for noise generation.
■ Protective Magnesium Anode Rod.
■ T&P Relief Valve—Installed.
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ Complies with the latest Ultra Low NOx requirement (10 ng/J NOx limit).
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238;
7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
1717-A-0418
Power Direct Vent Gas Water Heater
Power Direct Vent Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
NATURAL GAS
Nominal
Gal.
Capacity
Model
Number
U.S. Imp.
Gal. Gal.
ULG2PDV50H503N
48
Recovery at
100°F Rise*
DOE
Rated
Storage
Volume
(Gal.)
BTU/Hr.
Input
First
Hour
Rating
(Gal.)
Uniform
Energy
Factor
U.S.
GPH
Imp.
GPH
46
50,000
82
0.68
48
40
40
Model
Number
A
Floor to
Exhaust
Conn.
in.
B
Jacket
Dia.
in.
in.
ULG2PDV50H503N
67 5/16
22
3 or 4
Model
Number
A
Floor to
Exhaust
Conn.
mm.
B
Jacket
Dia.
C
Vent
Size
mm.
mm.
ULG2PDV50H503N
1708
559
76 or102
C
Vent
Size
13 7/8
59 11/16
6115/16 3111/16
D
E
G
H
F
Floor to Floor to Floor to Floor to Depth
T&P
Gas
Top of Water
Conn. Conn. Heater Conn.
mm.
mm.
mm.
mm.
mm.
1327
352
1516
1573
805
Recovery at
56°C Rise*
DOE
Rated
Storage
Volume
(Liters)
kW
Input
First
Hour
Rating
(Liters)
Uniform
Energy
Factor
Liters/
Hour
172
14.7
311
0.68
182
182
ULG2PDV50H503N
G
H
D
F
E
Floor to Floor to Floor to Floor to Depth
T&P
Top of Water
Gas
Conn. Conn. Heater Conn.
in.
in.
in.
in.
in.
52 1/4
Nominal
Liter
Capacity
Model
Number
J
K
L
M
P
R
S
N
C/L of
Floor to
Floor to
Water Floor to C/L Distance Space
Gas
Water Space Heating Space Heating Conn.
From Intake Heating Conn.
Air
Conn.
Inlet
Outlet
NPT
Intake to Exhaust Conn. Size Size
in.
in.
in.
in.
in.
in.
in.
in.
15 3/4
11
52 1/4
/
34
63 7/8
9 1/ 4
/
34
400
1327
19
1622
235
19
lbs.
in.
3 or 4
Approx.
Shipping
Weight
C
Vent
Size
13
kg.
mm.
91
76 or10
Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.
* Based on manufacturer’s rated recovery efficiency.
110 VAC Required for Power Venting / 110 VAC, 60Hz., 3.1 Amperes.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
C
P
H
M
J
C
P
M
ULG2PDV50H503N 3" Vent Pipe 4" Vent Pipe
100 ft.
Max. Intake Length
60 ft.
100 ft.
Max. Exhaust Length
60 ft.
7 ft.
Min. Vent Length
7 ft.
1
95 ft.
Number
55 ft.
90 ft.
50 ft.
2
of
3
85 ft.
45 ft.
90° Elbows
RAIN
R
CAP
A
A
M
G
R
A
B
F
S
G
B
F
D&L
S
E
N
E
D&L
Subtract 5ft. for each additional
N
90º elbow.
INTAKE/
COMBUSTION
AIR VENT
EXHAUST
R
Concentric Vent
K
Kit Termination
3" Kit
P/N 239-44069-01
A (in.)
36 1/4
R
K
General:
Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT
(19mm). All gas connections are 1/2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z21.10.1 and
peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
For field service, contact your professional installer or local Bradford White sales representative.
Ambler, PA
1717-A-0418
Sales 800-523-2931 n Fax 215-641-1612
Technical Support 800-334-3393 n Email [email protected]
Warranty 800-531-2111 n Email [email protected]
International: Telephone 1-215-641-9400 n Email [email protected] / www.bradfordwhite.com
©2018, Bradford White Corporation. All rights reserved.
C
Vent
Size
201
/
12
J
K
L
M
P
S
N
R
C/L of
Floor to
Floor to
Water Floor to C/L Distance Space
Gas
Water Space Heating Space Heating Conn.
From Intake Heating Conn.
Air
Conn.
Inlet
Outlet
NPT
Intake to Exhaust Conn. Size Size
mm.
mm.
mm.
mm.
mm.
mm.
mm.
mm.
279
Approx.
Shipping
Weight
Lite
Printed in U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the maximum exhaust length for the Bradford White U-PDX-75S-55FR-3N water heater?
The maximum exhaust length for the Bradford White U-PDX-75S-55FR-3N water heater is 100ft.
What is the minimum vent length for the Bradford White U-PDX-75S-55FR-3N water heater?
The minimum vent length for the Bradford White U-PDX-75S-55FR-3N water heater is 7ft.
How many 90-degree elbows can be used with the Bradford White U-PDX-75S-55FR-3N water heater?
Up to three 90-degree elbows can be used with the Bradford White U-PDX-75S-55FR-3N water heater.
What size vent pipe is required for the Bradford White U-PDX-75S-55FR-3N water heater?
A 3" or 4" vent pipe is required for the Bradford White U-PDX-75S-55FR-3N water heater.
What is the maximum intake length for the Bradford White U-PDX-75S-55FR-3N water heater?
The maximum intake length for the Bradford White U-PDX-75S-55FR-3N water heater is 100ft.
Download PDF