® 7000 SL 7800 SL 8500 SL P E I D DK Gebrauchsanweisung Tauchpumpe GB Operating Instructions Submersible Pump F Mode d’emploi Pompe d’évacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dränkbar pump I Istruzioni per l’uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instruções de utilização Bomba submersível DK Brugsanvisning Dykpumpe Art. 1780 Art. 1454 Art. 1782 S NL F GB D GARDENA GARDENA Submersible Pump 7000 SL / 7800 SL / 8500 SL GB Welcome to the garden of GARDENA ... Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the submersible pump, its correct use, and the notes on safety. For safety reasons, children under 16 as well as persons not familiar with these operating instructions should not use this submersible pump. v Keep these operating instructions in a safe place. Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. Applications Range of Your GARDENA Submersible Pump . . 11 For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1. Applications Range of Your GARDENA Submersible Pump Intended use GARDENA Submersible Pumps have been designed for private use around your house and garden. They are predominantly destinated for drainage after flooding, transfer of liquids, draining containers, taking water from wells and shafts, draining boats and yachts as well as for water aeration and circulation for a limited period of time. Liquids to be pumped Liquids which can be handled by the GARDENA Submersible Pump are the following: clean and slightly contaminated water (max. particle size 5 mm), swimming pool water (prerequisite is the recommended dosage of additives) and soapy water. The pumps are fully submersible (waterproof sealed) and can be immersed in the liquid down to a depth of 9 m. Please note The GARDENA Submersible Pumps are not designed for continuous operation (e.g. continuous circulating operation) in a pond. Your pump’s life will be shortened correspondingly by such operation. Corrosive, easily combustible or explosive substances (e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water and waste water of toilets and urinals must not be pumped. The temperature of the liquid handled should not exceed 35 °C. 11 2. For Your Safety According to DIN VDE (German Electrical Engineers’ Association) 0100, submersible pumps may only be used in swim-ming pools, garden ponds, and fountains if the pump is operated via a residual-current device with a residual-current rating of ≤ 30 mA. The pump must not be operated when there are persons in the swimming pool or garden pond. For safety reasons we recommend that you always operate the submersible pump via a residual-current device (DIN VDE 0100-702 and 0100-738). v Please contact your electrician. In Austria In Austria, according to ÖVE B / EN 60 555 part 1 to 3, pumps which are used in swimming pools and garden ponds, and equipped with firm power cable should be fed via an ÖVE approved isolating transformer – rated voltage must not exceed 230 V. In Switzerland In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device. Mains power According to DIN VDE (German Electrical Engineers’ Association) 0620, mains power cables must not have a smaller crosssection than the rubber-sheathed cables of the designation H05 RNF. The cable length must be at least 10 m. Data indicated on the type plate must match technical data of the mains supply. v Take care that the electrical connections are made within dry area, protected from flooding. Protect plug and power cable from heat, oil and sharp edges. v Don’t use the power cable for plugging off. The power cable or the float switch must not be used for mounting or relocating the pump. For submerging or lifting / securing the pump, fix a rope to the pump’s carrying handle. Extension cables must meet the requirements of DIN VDE 0620. Visual check v Before operating the pump, first make a visual check, if there is any damage of the pump (esp. regarding power cable and plug). v Observe the minimum water level and the max. delivery height (see 8. Technical Data). A damaged pump must not be used. v In case of damage, please have the pump checked by our GARDENA Service Centre. Manual operation During manual operation, the pump must be switched off as soon as all the liquid has been pumped away. v Observe the pump at all times during manual operation. Notes on use When you purchase your pump the swivel feet are set to the flat suction position (1 mm). v For normal operation, turn the feet 180° to 5 mm. The pump is lifted 5 mm. GB Residual-current device 12 Thermal motor protector The pump is automatically switched off on overheating by the built-in thermal motor protector. After having cooled down, the motor automatically switches on again (see 6. Trouble Shooting). Automatic deaerating valve The automatic deaerating valve eliminates any air pockets in the pump. Air escapes by the vent bores 4 and air bubbles form under water. This is not a defect of your pump, but serves to deaerate the pump. It may take several seconds for the air to escape when the pump is immersed for the first time. 4 GB v Clear the outlet line before use. Dry-running operation causes increased wear and is to be avoided. Therefore, in manual operation the pump must be immediately unplugged when water fails to flow. Avoid running of the pump for more than 10 min. against closed delivery side of the pump. Sand and other abrasive substances cause increased wear and reduce the pump’s output. Take care that the pump is located where the inlet openings at the suction base are obstructed neither completely nor partly. Stand the pump on a brick if using in a pond. 3. Initial Operation 13 mm (1/ 2 ”) 15 mm (5 / 8”) 19 mm (3 /4”) Hose diameter 25 mm (1”) 38 mm (1 1/ 2 ”) Do not cut off any nipples. Cut off top two nipples at b. a b 7 Hose connection of universal fitting Hose connection 7 Cut off topmost nipple at a. The following connection kits are required for 13 mm to 19 mm connections: 13 mm (1/ 2 ”): GARDENA Pump Connection Set, Art. No. 1750 15 mm (5/ 8 ”): GARDENA Tap Connector, Art. No. (2)902, and Standard Hose Connector, Art. No. (2)916 19 mm (3 /4 ”): GARDENA Pump Connection Set, Art. No. 1752 Best results in delivery capacity are achieved when using 38 mm (1 1/ 2 ”) hoses. 13 GB Connecting the hose : 7 The universal fitting 7 allows you to connect all the hoses listed in the previous table. 1. Cut off nipples of the universal fitting 7, which are not needed, to match the hose connection. 2. Screw the universal fitting 7 onto the pump. 3. Connect the hose to the universal fitting 7. We recommend that you secure 38 mm (1 1/ 2 ”) and 25 mm (1”) hoses additionally with a GARDENA Hose Clip Art. No. 1591. For flat suction we recommend using a 13 mm (1/ 2 ”) or 15 mm (5 /8 ”) hose. Only for 13 mm (1/ 2”) hose : The universal fitting 7 can also be equipped with a GARDENA Regulator Valve Art. No. 977 so that the contents of the outlet line do not flow back through the pump after pumping. The Regulator Valve can be ordered from your GARDENA dealer. 4. Operation V If the water height is lower than 3.5 cm, fill the pump before operation over the universal fitting 7 with water. Flat suction / Normal operation : Normal operation : v Turn the 3 swivel feet 8 180° to 1 mm. Flat suction up to 1 mm. v Turn the 3 swivel feet 8 180° to 5 mm. Flat suction up to 5 mm. The residual water level of approx. 1 mm is only reached during flat suction in the manual operation mode. If the water level is lower than 25 mm, you can accelerate flat suction by switching the pump off and on 2 to 3 times. 8 The float switch 5 turns the pump on automatically when the water level exceeds the cut-in height and the water is pumped out. Automatic operation : 1 2 The float switch 5 turns the pump off again as soon as the water level falls below the cut-out height. 1. Stand the pump on a firm surface – or – use a rope attached through the bore hole in the carrying handle 2 to immerse the pump in a well or shaft. During automatic operation, ensure that the float switch 5 can move freely. 2. Plug the power cable 1 into a mains socket. 3 5 14 Flat suction : Adjusting the Cut-in and Cut-out Height : The maximum cut-in height and minimum cut-out height (see 8. Technical Data) can be adjusted. v Push the cable of the float switch 5 into the float switch lock 3. Do not select a cable length that is too long or short to ensure that the float switch can turn on and off properly. The cable length between the float switch lock 3 must always be at least 10 cm. Manual operation : 1 2 5 5 and the float switch The pump remains in constant operation because the float switch is bypassed. 1. Push the float switch 5 onto the float switch lock 3 with the cable downward. 2. Stand the pump on a firm surface – or – use a rope attached through the bore hole in the carrying handle 2 to immerse the pump in a well or shaft. 3. Plug the power cable 1 into a mains socket. The residual water level of approx. 1 mm is only reached during flat suction in the manual operation mode. 3 5. Cleaning The pumps are virtually maintenance-free. After having pumped chlorinated swimming pool water or other liquids leaving residues, the pump should be rinsed with clear water. Flushing the Pump : Cleaning the suction base and impeller : A 8 9 6 0 A Warning ! Electric shock ! Risk of injury due to electric shock. V Disconnect the submersible pump from the mains before cleaning the suction base and impeller. 1. Unscrew the Phillips screw A and pull the suction base cover 0 off the suction base 6. 2. Unscrew the 4 Phillips screws 8 (model 8500 SL: 6 Phillips screws) and pull the suction base 6 off the pump. 3. Clean the suction base cover 0, suction base 6 and impeller 9. 4. Reinstall the suction base 6 and screw in the Phillips screws 8. Tip : It is often sufficient to simply remove the suction base cover 0 and clean the suction base cover 0 and suction base 6. 15 For safety reasons a damaged impeller 9 can only be exchanged by the GARDENA Service Centre. 15 GB • The higher the opening of the float switch lock 3, the higher the cut-in and cut-out height. • The shorter the length of cable between the float switch 5 and the float switch lock 3, the lower the cut-in height and the higher the cut-out height. 6. Trouble-Shooting Probable cause Remedy Pump is running, but doesn’t deliver. Air cannot escape, since pressure line is closed. v Open pressure line (e.g. kinked pressure pipe). Air locks in the suction base. v Wait for max. 3 minutes until the pump deaerates automatically over the vent valve. If necessary, switch off and start it again. Impeller clogged. v Disconnect plug and clean impeller (see 5. Cleaning). When starting the pump, water height falls below the min. water level. v Fill the pump over the universal fitting 7 with water. Thermal overload switch has switched the pump off due to overheating. v Disconnect plug and clean impeller (see 5. Cleaning). Observe max. media temperature of 35 °C. No power. v Check fuses and electric connections. Dirt particles are jammed in the suction base. v Disconnect plug and clean suction base (see 5. Cleaning). Pump runs, but output suddenly decreases. Suction base is clogged. v Disconnect plug and clean suction base (see 5. Cleaning). Pump does not reach residual water height of 1 mm during flat suction. The suction base cover 0 is missing in the suction base. v Disconnect the plug from the mains and install the suction base cover 0 (see 5. Cleaning). GB Problem Pump doesn’t start or suddenly stops during operation. Attention ! Repairs on electrical parts should only be done by our GARDENA Service Centres. If you have any problems with your Pump, please contact our Service. 7. Storing Your Pump Store the pump away from frost before the first frost sets in. Disposal : (in accordance with RL2002 / 96 / EC) 16 The product must not be added to normal household waste. It must be disposed of properly. 8. Technical Data 7000 SL (Art. 1780) 7800 SL (Art. 1454) 8500 SL (Art. 1782) Rated power 250 W 280 W 300 W Max. delivery capacity 7,000 l / h 7,800 l / h 8,500 l / h Max. pressure 0.6 bar 0.65 bar 0.7 bar Max. delivery height 6m 6,5 m 7m Max. submersion depth 9m 9m 9m Flat suction down to approx. 1 mm 1 mm 1 mm Contaminated water with particle size of max. 5 mm 5 mm 5 mm Power cable 10 m H05 RNF 10 m H05 RNF 10 m H05 RNF GB Type 38 mm (1 1/ 2 ”) / 25 mm (1”) graduated nipple, option GARDENA Water hose Plug-in-system Pump connection Min. water level for operation 35 mm 35 mm 35 mm Weight approx. 4.3 kg 4.7 kg 5.3 kg Max. media temperature 35 °C 35 °C 35 °C Mains voltage / mains frequency 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Min. cut-in height 175 mm 170 mm 160 mm Min./ max. cut-out height 65 mm / 140 mm 65 mm / 125 mm 50 mm / 125 mm Noise level L WA1) 46 dB (A) 46 dB (A) 46 dB (A) 1) Measuring method according to EN 60335 -1 Cut-in / Cut-out height The cut-in and cut-out height varies. The residual water height (flat suction down to approx. 1 mm) is only reached during manual operation with the swivel feet 8 turned to 1 mm (see 4. Operation). Performance characteristics m bar 10 1,0 8 0,8 0,6 6 700 0S L 4 780 0S 0,4 L 850 0S 2 L 0,2 0 0 2500 5000 7500 10000 l/h 17 9. Service GB Warranty GARDENA guarantees this product for 2 years ( from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply: • The unit must have been handled properly and in keeping with the requirements of the operating instructions. • Neither the purchaser or a non-authorised third party have attempted to repair the unit. The impeller is a wearing part and is not covered by the guarantee. This manufacturer’s guarantee does not affect the user’s existing warranty claims against the dealer / seller. If you have any problems with your pump, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet. Product Liability We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories. EU Certificate of Conformity The undersigned GARDENA Manufacturing GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm hereby certifies that, when leaving our factory, the units indicated below are in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the units are modified without our approval. Description of the units : Type : Art. No. : EU directives : Harmonised European standards : Year of CE marking : 18 Submersible Pump 7000 SL / 7800 SL / 8500 SL 1780 / 1454 / 1782 Machinery Directive 98 / 37/ EC Electromagnetic Compatibility 89 / 336 / EC Low Voltage Directive 73 / 23 / EC Directive 93 / 68 / EC EN 292 -1 EN 292 - 2 EN 60335 -1 EN 60335 - 2 - 41 2001 Ulm, 21.11.2001 Thomas Heinl Technical Dept. Manager Deutschland / Germany GARDENA Manufacturing GmbH Service Center Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (+ 49) 731 490 - 123 Reparaturen: (+ 49) 731 490 - 290 [email protected] Croatia KLIS d.o.o. Stanciceva 79 10419 Vukovina Phone: (+ 385) 1 622 777 0 [email protected] Cyprus FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia Phone: (+ 357) 22 75 47 62 Argentina [email protected] Argensem ® S.A. Calle Colonia Japonesa s / n Czech Republic (1625) Loma Verde GARDENA spol. s r.o. Escobar, Buenos Aires Шнpskб 20 a, и.p. 1153 Phone: (+ 54) 34 88 49 40 40 627 00 Brno [email protected] Phone: (+ 420) 800 100 425 [email protected] Australia Nylex Consumer Products Denmark 50 -70 Stanley Drive GARDENA Norden AB Somerton, Victoria, 3062 Salgsafdeling Danmark Phone: (+ 61) 1800 658 276 Box 9003 [email protected] S-200 39 Malmö [email protected] Austria / Österreich GARDENA Finland Österreich Ges.m.b.H. Habitec Oy Stettnerweg 11-15 Martinkyläntie 52 2100 Korneuburg 01720 Vantaa Tel. : (+ 43) 22 62 7 45 45 36 France [email protected] GARDENA Belgium PARIS NORD 2 GARDENA Belgium NV/ SA 69, rue de la Belle Etoile Sterrebeekstraat 163 BP 57080 1930 Zaventem ROISSY EN FRANCE Phone: (+ 32) 2 7 20 92 12 95948 ROISSY CDG CEDEX Mail: [email protected] Tél. (+ 33) 0826 101 455 [email protected] Brazil gardena.fr Palash Comércio e Importação Ltda. Great Britain Rua Américo Brasiliense, GARDENA UK Ltd. 2414 - Chácara Sto Antonio 27- 28 Brenkley Way São Paulo - SP - Brasil Blezard Business Park CEP 04715-005 Seaton Burn Phone: (+ 55) 11 5181- 0909 Newcastle upon Tyne [email protected] NE13 6DS [email protected] Bulgaria DENEX LTD. Greece 2 Luis Ahalier Str. - 7th floor Agrokip Sofia 1404 Psomadopoulos S.A. Phone: (+ 359) 2 958 18 21 Ifaistou 33A [email protected] Industrial Area Koropi 194 00 Athens Greece Canada V.A.T. EL093474846 GARDENA Canada Ltd. Phone: (+ 30) 210 66 20 225 100 Summerlea Road [email protected] Brampton, Ontario L6T 4X3 Phone: (+1) 905 792 93 30 Hungary [email protected] GARDENA Magyarország Kft. Chile Késmárk utca 22 Antonio Martinic y Cia Ltda. 1158 Budapest Cassillas 272 Phone: (+ 36) 80 20 40 33 Centro de Cassillas [email protected] Santiago de Chile Phone: (+ 56) 2 20 10 708 Iceland [email protected] Ó. Johnson & Kaaber Tunguhalsi 1 Costa Rica 110 Reykjavik Compania Exim [email protected] Euroiberoamericana S.A. Los Colegios, Moravia, Ireland 200 metros al Sur del Colegio Michael McLoughlin & Sons Saint Francis - San José Hardware Limited Phone: (+ 506) 297 68 83 Long Mile Road [email protected] Dublin 12 Italy GARDENA Italia S.p.A. Via Donizetti 22 20020 Lainate (Mi) Phone: (+ 39) 02.93.94.79.1 [email protected] Japan KAKUICHI Co. Ltd. Sumitomo Realty & Development Kojimachi BLDG., 8F 5 -1 Nibanncyo, Chiyoda-ku Tokyo 102-0084 Phone: (+ 81) 33 264 4721 [email protected] Luxembourg Magasins Jules Neuberg Grand Rue 30 Boîte postale 12 L- 2010 Luxembourg Phone: (+ 352) 40 14 01 [email protected] Netherlands GARDENA Nederland B.V. Postbus 50176 1305 AD ALMERE Phone: (+ 31) 36 521 00 00 [email protected] Neth. Antilles Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao Phone: (+ 599) 9 767 66 55 [email protected] New Zealand NYLEX New Zealand Limited Building 2, 118 Savill Drive Mangere, Auckland Phone: (+ 64) 9 270 1806 [email protected] Norway GARDENA Norden AB Salgskontor Norge Karihaugveien 89 1086 Oslo [email protected] Poland GARDENA Polska Sp. z o.o. Szymanów 9 d 05 - 532 Baniocha Phone: (+ 48) 22 727 56 90 [email protected] Portugal GARDENA Portugal Lda. Recta da Granja do Marquês Edif. GARDENA Algueirão 2725-596 Mem Martins Phone: (+ 351) 21 922 85 30 [email protected] Romania MADEX INTERNATIONAL SRL Soseaua Odaii 117-123, Sector 1, Bucureєti, RO 013603 Phone: (+ 40) 21 352 76 03 [email protected] Russia / Россия ООО ГАРДЕНА РУС 123007, г. Москва Хорошевское шоссе, д. 32А Тел.: (+ 7) 495 247 25 10 [email protected] Singapore Hy - Ray PRIVATE LIMITED 40 Jalan Pemimpin # 02-08 Tat Ann Building Singapore 577185 Phone: (+ 65) 6253 2277 [email protected] Slovak Republic GARDENA Slovensko, s.r.o. Panónska cesta 17 851 04 Bratislava Phone: (+ 421) 263 453 722 [email protected] Slovenia GARDENA d.o.o. Brodiљиe 15 1236 Trzin Phone: (+ 386) 1 580 93 32 [email protected] South Africa GARDENA South Africa (Pty.) Ltd. P.O. Box 11534 Vorna Valley 1686 Phone: (+ 27) 11 315 02 23 [email protected] Spain GARDENA IBÉRICA S.L.U. C / Basauri, nº 6 La Florida 28023 Madrid Phone: (+ 34) 91 708 05 00 [email protected] Sweden GARDENA Norden AB Försäljningskontor Sverige Box 9003 200 39 Malmö [email protected] Switzerland / Schweiz GARDENA (Schweiz) AG Bitziberg 1 8184 Bachenbülach Phone: (+ 41) 848 800 464 [email protected] Turkey GARDENA / Dost Diþ Ticaret Mümessillik A.Þ. Sanayi Çad. Adil Sokak No. 1 Kartal - Ýstanbul Phone: (+ 90) 216 38 93 939 [email protected] Ukraine / Украина ALTSEST JSC 4 Petropavlivska Street Petropavlivska Borschahivka Town Kyivo Svyatoshyn Region 08130, Ukraine Phone: (+ 380) 44 459 57 03 [email protected] USA Melnor Inc. 3085 Shawnee Drive Winchester, VA 22604 Phone: (+1) 540 722-9080 [email protected] 1780- 20.960.10 / 1006 © GARDENA Manufacturing GmbH D - 89070 Ulm http: //www.gardena.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement