BFT Thalia P Control Panel Instruction manual
BFT Thalia P is created so you can remotely open and close gates and doors safely, comfortably, and conveniently. It meets the highest safety standards during use with a self-monitoring control system.
Advertisement
Advertisement
QUADRO COMANDO CONTROL PANEL CENTRALE DE COMMANDE SELBSTÜBERWACHENDE STEUERUNG CUADRO DE MANDOS BEDIENINGSPANEEL
Attenzione!
Leggere attentamente le “Avvertenze” all’interno!
Caution!
Read “Warnings” inside carefully!
Attention!
Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur!
Achtung!
Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren!
¡Atención¡
Leer atentamente las “Advertencias” en el interior!
Let op!
Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
AVVERTENZE PER L’UTILIZZATORE ( I ) ATTENZIONE! Importanti istruzioni di sicurezza. e le Istruzioni che accompagnano il prodotto poiché un uso improprio può causare danni a persone, animali o cose. Conservare le istruzioni per consultazioni future e trasmetterle ad even tuali subentranti nell’uso dell’impianto.
Questo prodotto dovrà essere destinato solo all’uso per il quale è stato espressamente insta llato. Ogni altro uso è da considerarsi improprio e quindi pericoloso. Il costruttore non può essere considerato responsabile per eventuali danni causati da usi impropri, erronei e irragionevoli.
SICUREZZA GENERALE
Nel ringraziarVi per la preferenza accordata a questo prodotto, la Ditta è certa che da esso otterrete le prestazioni necessarie al Vostro uso.
Questo prodotto risponde alle norme riconosciute della tecnica e della disposizioni relative alla si curezza se correttamente installato da personale qualificato ed esperto (installatore professionale).
L’automazione, se installata ed utilizzata corretta mente, soddisfa gli standard di sicurezza nell’uso. Tuttavia è opportuno osservare alcune regole di comportamento per evitare inconvenienti acci dentali: - Tenere bambini, persone e cose fuori dal raggio d’azione dell’automazione, in particolare durante il movimento.
- Non permettere a bambini di giocare o sostare nel raggio di azione dell’automazione.
- L’apparecchio può essere utilizzato da bambini di età non inferiore a 8 anni e da persone con ridot te capacità fisiche, sensoriali o mentali, o prive di esperienza o della necessaria conoscenza, purché sotto sorveglianza oppure dopo che le stesse abbiano ricevuto istruzioni relative all’uso sicuro dell’apparecchio e alla comprensione dei pericoli ad esso inerenti. I bambini non devono giocare con l’apparecchio. La pulizia e la manutenzione desti nata ad essere effettuata dall’utilizzatore non deve essere effettuata da bambini senza sorveglianza.
- I bambini devono essere sorvegliati per sincerarsi che non giochino con l’apparecchio. Non permet tere ai bambini di giocare con i controlli fissi. Tenere i telecomandi lontani dai bambini.
- Evitare di operare in prossimità delle cerniere o organi meccanici in movimento.
- Non contrastare il movimento dell’anta e non ten tare di aprire manualmente la porta se non è stato sbloccato l’attuatore con l’apposita manopola di sblocco.
- Non entrare nel raggio di azione della porta o can cello motorizzati durante il loro movimento.
- Non lasciare radiocomandi o altri dispositivi di comando alla portata dei bambini onde evitare azionamenti involontari.
- L’attivazione dello sblocco manuale potrebbe causare movimenti incontrollati della porta se in presenza di guasti meccanici o di condizioni di squilibrio.
- In caso di apritapparelle: sorvegliare la tapparella in movimento e tenere lontano le persone finché non è completamente chiusa. Porre cura quando si aziona lo sblocco se presente, poiché una tapparella aperta potrebbe cadere rapidamente in presenza di usura o rotture.
- La rottura o l’usura di organi meccanici della porta 2 THALIA P D811767_07 (parte guidata), quali ad esempio cavi, molle, sup controllare periodicamente l’impianto da personale qualificato ed esperto (installatore professionale) secondo quanto indicato dall’installatore o dal costruttore della porta.
- Per ogni operazione di pulizia esterna, togliere l’alimentazione di rete.
- Tenere pulite le ottiche delle fotocellule ed i dispo sitivi di segnalazione luminosa. Controllare che rami ed arbusti non disturbino i dispositivi di sicurezza.
- Non utilizzare l’automatismo se necessita di interventi di riparazione. In caso di guasto o di malfunzionamento dell’automazione, togliere l’alimentazione di rete sull’automazione, astenersi da qualsiasi tentativo di riparazione o intervento diretto e rivolgersi solo a personale qualificato ed esperto (installatore professionale) per la neces saria riparazione o manutenzione. Per consentire l’accesso, attivare lo sblocco di emergenza (se presente).
- Per qualsiasi intervento diretto sull’automazione o sull’impianto non previsto dal presente manuale, avvalersi di personale qualificato ed esperto (insta llatore professionale).
- Con frequenza almeno annuale far verifi care l’integrità e il corretto funzionamento dell’automazione da personale qualificato ed esperto (installatore professionale), in particolare di tutti i dispositivi di sicurezza.
- Gli interventi d’installazione, manutenzione e riparazione devono essere documentati e la relativa documentazione tenuta a disposizione dell’utilizzatore.
- Il mancato rispetto di quanto sopra può creare situazioni di pericolo.
DEMOLIZIONE
L’eliminazione dei materiali va fatta rispettan do le norme vigenti. Non gettate il vostro apparecchio scartato, le pile o le batterie usate nei rifiuti domestici. Avete la responsabilità di restituire tutti i vostri rifiuti da apparecchia ture elettriche o elettroniche lasciandoli in un punto di raccolta dedicato al loro riciclo.
Tutto quello che non è espressamente previs to nel manuale d’uso, non è permesso. ll buon funzionamento dell’operatore è garantito solo se vengono rispettate le prescrizioni riportate in questo manuale. La Ditta non risponde dei danni causati dall’inosservanza delle indicazioni riportate in questo manuale.
Lasciando inalterate le caratteristiche essenziali del prodotto, la Ditta si riserva di apportare in qualunque momento le modifiche che essa ritie truttivamente e commercialmente il prodotto, pubblicazione.
USER WARNINGS (GB) WARNING! Important safety instructions. Ca refully read and comply with the Warnings and Instructions that come with the product as impro per use can cause injury to people and animals and damage to property. Keep the instructions for future reference and hand them on to any new users.
This product is meant to be used only for the
purpose for which it was explicitly installed. Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use.
GENERAL SAFETY
Thank you for choosing this product. The Firm is confident that its performance will meet your ope rating needs.
This product meets recognized technical standards and complies with safety provisions when installed correctly by qualified, expert personnel (professional installer).
If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided: - Keep adults, children and property out of range of the automated system, especially while it is moving.
- Do not allow children to play or stand within range of the automated system.
- The unit can be used by children over 8 years old and by people with reduced physical, sensory or mental capabilities or with no experience or neces sary knowledge on condition they are supervised or trained about the safe use of the equipment and understand the risks involved. Children must not play with the unit. Cleaning and maintenance must not be performed by unsupervised children.
- Children must be supervised to ensure they do not play with the device. Do not allow children to play with the fixed controls. Keep remote controls out of reach of children.
- Do not work near hinges or moving mechanical parts.
- Do not hinder the leaf’s movement and do not attempt to open the door manually unless the ac tuator has been released with the relevant release knob.
- Keep out of range of the motorized door or gate while they are moving.
- Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.
- The manual release’s activation could result in un controlled door movements if there are mechanical faults or loss of balance.
- When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fitted, as an open shutter could drop quickly in the event of wear or breakage.
- The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard. Have the system checked by qualified, expert per sonnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door.
- When cleaning the outside, always cut off mains power.
- Keep the photocells’ optics and illuminating in dicator devices clean. Check that no branches or shrubs interfere with the safety devices.
- Do not use the automated system if it is in need of repair. In the event the automated system breaks system; do not attempt to repair or perform any call in qualified, expert personnel (professional installer) to perform the necessary repairs or main release (where fitted).
- If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of qualified, expert personnel (professional installer).
- At least once a year, have the automated system, and especially all safety devices, checked by qualified, expert personnel (professional installer) to make sure that it is undamaged and working properly.
- A record must be made of any installation, main tenance and repair work and the relevant docu mentation kept and made available to the user on request.
- Failure to comply with the above may result in hazardous situations.
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used bat teries with household waste. You are respon sible for taking all your waste electrical and electronic equipment to a suitable recycling centre.
Anything that is not explicitly provided for in the user guide is not allowed. The operator’s proper operation can only be guaranteed if the instruc tions given herein are complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, improve the product from a technical, design or to update this publication accordingly.
D811767_07 THALIA P - 3
AVVERTENZE PER L’INSTALLATORE ATTENZIONE! Importanti istruzioni di sicurezza. Leggere e seguire atten tamente tutte le avvertenze e le istruzioni che accompagnano il prodotto poiché un’installazione errata può causare danni a persone, animali o cose. Le avvertenze e le istruzioni forniscono importanti indicazioni riguardanti la sicurezza, l’installazione, l’uso e la manutenzione. Conservare le istruzioni per allegarle al fascicolo tecnico e per consultazioni future.
SICUREZZA GENERALE
Questo prodotto è stato progettato e costruito esclusivamente per l’utilizzo indicato in questa documentazione. Usi diversi da quanto indicato potrebbero essere causa di danni al prodotto e di pericolo.
-Gli elementi costruttivi della macchina e l’installazione devono essere in accor do con le seguenti Direttive Europee, ove applicabili: 2014/30/CE, 2014/35/CE, 2006/42/CE, 2011/305/CE, 99/05/CE e loro modifiche successive. Per tutti i Paesi extra CEE, oltre alle norme nazionali vigenti, per un buon livello di sicurezza è opportuno rispettare anche le norme citate.
-La Ditta costruttrice di questo prodotto (di seguito “Ditta”) declina qualsiasi responsabilità derivante da un uso improprio o diverso da quello per cui è destinato e indicato nella presente documentazione nonché dall’inosservanza della Buona Tecnica nella costruzione delle chiusure (porte, cancelli, ecc.) e dalle deformazioni che potrebbero verificarsi durante l’uso.
-L’installazione deve essere eseguita da personale qualificato (installatore profes sionale, secondo EN12635), nell’osservanza della Buona Tecnica e delle norme vigenti.
-Prima di installare il prodotto apportare tutte le modifiche strutturali relative alle realizzazione dei franchi di sicurezza a alla protezione o segregazione di tutte le zone di schiacciamento, cesoiamento, convogliamento e di pericolo in genere, secondo quanto previsto dalle norme EN 12604 ed 12453 o eventuali norme locali di installazione. Verificare che la struttura esistente abbia i necessari requisiti di robustezza e stabilità.
-Prima di iniziare l’installazione verificare l’integrità del prodotto.
-La Ditta non è responsabile della inosservanza della Buona Tecnica nella costru zione e manutenzione degli infissi da motorizzare, nonché delle deformazioni che dovessero intervenire nell’utilizzo.
-Verificare che l’intervallo di temperatura dichiarato sia compatibile con il luogo destinato all’installazione dell’automazione.
-Non installare questo prodotto in atmosfera esplosiva: la presenza di gas o fumi infiammabili costituisce un grave pericolo per la sicurezza.
- Togliere l’alimentazione elettrica, prima di qualsiasi intervento sull’impianto. Scollegare anche eventuali batterie tampone se presenti.
-Prima di collegare l’alimentazione elettrica, accertarsi che i dati di targa corrispon dano ai quelli della rete di distribuzione elettrica e che a monte dell’impianto elettrico vi siano un interruttore differenziale e una protezione da sovracorrente adeguati. Prevedere sulla rete di alimentazione dell’automazione, un interruttore o un magnetotermico onnipolare che consenta la disconnessione completa nelle condizioni della categoria di sovratensione III.
-Verificare che a monte della rete di alimentazione, vi sia un interruttore differen ziale con soglia non superiore a 0.03A e a quanto previsto dalle norme vigenti.
-Verificare che l’impianto di terra sia realizzato correttamente: collegare a terra tutte le parti metalliche della chiusura (porte, cancelli, ecc.) e tutti i componenti dell’impianto provvisti di morsetto di terra.
-L’installazione deve essere fatta utilizzando dispositivi di sicurezza e di comandi conformi alla EN 12978 e EN12453.
-Le forze di impatto possono essere ridotte mediante l’utilizzo di bordi deformabili.
-Nel caso in cui le forze di impatto superino i valori previsti dalle norme, applicare dispositivi elettrosensibili o sensibili alla pressione.
-Applicare tutti i dispositivi di sicurezza (fotocellule, coste sensibili, ecc.) necessari a proteggere l’area da pericoli di impatto, schiacciamento, convogliamento, cesoiamento. Tenere in considerazione le normative e le direttive in vigore, i criteri della Buona Tecnica, l’utilizzo, l’ambiente di installazione, la logica di funzionamento del sistema e le forze sviluppate dall’automazione.
-Applicare i segnali previsti dalle normative vigenti per individuare le zone pericolose (i rischi residui). Ogni installazione deve essere identificata in modo visibile secondo quanto prescritto dalla EN13241-1.
- Successivamente al completamento dell’installazione, applicare una targa identificativa della porta/cancello -Questo prodotto non può essere installato su ante che incorporano delle porte (a meno che il motore sia azionabile esclusivamente a porta chiusa).
-Se l’automazione è installata ad una altezza inferiore a 2,5 m o se è accessibile, è necessario garantire un adeguato grado di protezione delle parti elettriche e meccaniche.
-Solo per automazioni per serrande 1) Le parti in movimento del motore devono essere installate ad una altezza superiore a 2,5m al di sopra del pavimento o al di sopra di un altro livello che possa consentirne l’accesso.
2) Il motoriduttore deve essere installato in uno spazio segregato e provvisto di protezione in modo che sia accessibile solo con uso di utensili.
-Installare qualsiasi comando fisso in posizione tale da non causare pericoli e lontano da parti mobili. In particolare i comandi a uomo presente devono essere posizionati in vista diretta della parte guidata, e, a meno che non siano a chiave, devono essere installati a una altezza minima di 1,5 m e in modo tale da non essere accessibili al pubblico.
-Applicare almeno un dispositivo di segnalazione luminosa (lampeggiante) in posizione visibile, fissare inoltre alla struttura un cartello di Attenzione.
-Fissare in modo permanente una etichetta relativa al funzionamento dello sblocco manuale dell’automazione e apporla vicino all’organo di manovra.
-Assicurarsi che durante la manovra siano evitati o protetti i rischi meccanici ed in particolare l’impatto, lo schiacciamento, il convogliamento, il cesoiamento tra parte guidata e parti circostanti.
-Dopo aver eseguito l’installazione, assicurarsi che il settaggio dell’automazione motore sia correttamente impostato e che i sistemi di protezione e di sblocco funzionino correttamente.
-Usare esclusivamente parti originali per qualsiasi manutenzione o riparazione.
La Ditta declina ogni responsabilità ai fini della sicurezza e del buon funziona mento dell’automazione se vengono impiegati componenti di altri produttori.
-Non eseguire alcuna modifica ai componenti dell’automazione se non espres samente autorizzata dalla Ditta.
-Istruire l’utilizzatore dell’impianto per quanto riguarda gli eventuali rischi residui, i sistemi di comando applicati e l’esecuzione della manovra apertura manuale in caso di emergenza: consegnare il manuale d’uso all’utilizzatore finale.
-Smaltire i materiali di imballo (plastica, cartone, polistirolo, ecc.) secondo quanto previsto dalle norme vigenti. Non lasciare buste di nylon e polistirolo alla portata dei bambini.
COLLEGAMENTI ATTENZIONE! ATTENZIONE!
cancello.
Per il collegamento alla rete utilizzare: cavo multipolare di sezione minima 5x1,5mm (asta verticale). 2 o 4x1,5mm con sezione 4x1.5mm
2 con sezione minima di 0,5 mm 2 2 .
per alimentazioni trifase oppure 3x1,5mm -Utilizzare esclusivamente pulsanti con portata non inferiore a 10A-250V.
separate le parti in tensione dalle parti in bassissima tensione di sicurezza.
a tendersi in caso di allentamento del dispositivo di fissaggio del cavo.
fisicamente separati dai conduttori a bassa tensione.
personale qualificato (installatore professionale)
VERIFICA DELL’AUTOMAZIONE E MANUTENZIONE
di manutenzione, controllare scrupolosamente quanto segue: -Verificare che tutti i componenti siano fissati saldamente; -Verificare l’operazione di avvio e fermata nel caso di comando manuale.
-Verificare la logica di funzionamento normale o personalizzata.
scorrimento sempre pulita e libera da detriti.
samento o oscillazione durante la manovra.
perfettamente verticale.
- Solo per barriere: prima di aprire la portina la molla deve essere scarica norma EN 12445, sia inferiore a quanto indicato nella norma EN 12453.
-Verificare la funzionalità della manovra di emergenza ove presente.
stato delle guaine isolanti e dei pressa cavi.
-Durante la manutenzione eseguire la pulizia delle ottiche delle fotocellule.
guidata e permettere così l’ apertura e la chiusura manuale del cancello.
con qualifica similare, in modo da prevenire ogni rischio. frequenza almeno semestrale.
2 per alimentazioni monofase (a titolo di esempio, il cavo può essere del tipo H05RN-F ). Per il collegamento degli ausiliari utilizzare conduttori -I conduttori devono essere vincolati da un fissaggio supplementare in prossi mità dei morsetti (per esempio mediante fascette) al fine di tenere nettamente -Il cavo di alimentazione, durante l’installazione, deve essere sguainato in modo da permettere il collegamento del conduttore di terra all’appropriato morsetto lasciando però i conduttori attivi il più corti possibile. Il conduttore di terra deve essere l’ultimo i conduttori a bassissima tensione di sicurezza devono essere L’accessibilità alle parti in tensione deve essere possibile esclusivamente per il Prima di rendere definitivamente operativa l’automazione, e durante gli interventi -Solo per cancelli scorrevoli: verificare il corretto ingranamento cremagliera pignone con un gioco di 2 mm lungo tutta la cremagliera; tenere la rotaia di -Solo per cancelli e porte scorrevoli: verificare che il binario di scorrimento del cancello sia lineare, orizzontale e le ruote siano idonee a sopportare il peso del -Solo per cancelli scorrevoli sospesi (Cantilever): verificare che non ci sia abbas -Solo per cancelli a battente: verificare che l’asse di rotazione delle ante sia -Controllare il corretto funzionamento di tutti i dispositivi di sicurezza (fotocellule, coste sensibili, ecc) e la corretta regolazione della sicurezza antischiacciamento verificando che il valore della forza d’impatto misurato nei punti previsti dalla -Le forze di impatto possono essere ridotte mediante l’utilizzo di bordi deformabili.
-Verificare l’operazione di apertura e chiusura con i dispositivi di comando applicati.
-Verificare l’integrità delle connessioni elettriche e dei cablaggi, in particolare lo -Per il periodo di fuori servizio dell’automazione, attivare lo sblocco di emergenza (vedi paragrafo “MANOVRA DI EMERGENZA”) in modo da rendere folle la parte -Se il cavo di alimentazione è danneggiato, esso deve essere sostituito dal co struttore o dal suo servizio di assistenza tecnica o comunque da una persona -Se si si installano dispositivi di tipo “D” (come definiti dalla EN12453), collegati in modalità non verificata, prescrivere una manutenzione obbligatoria con - La manutenzione come sopra descritta deve essere ripetuta con frequenza almeno annuale o ad intervalli di tempo minori qualora le caratteristiche del sito o dell’installazione lo richiedessero.
ATTENZIONE!
Ricordarsi che la motorizzazione è una facilitazione dell’uso del cancello/porta e non risolve problemi a difetti e deficienze di installazione o di mancata manutenzione.
DEMOLIZIONE
L’eliminazione dei materiali va fatta rispettando le norme vigenti. Non gettate il vostro apparecchio scartato, le pile o le batterie usate nei rifiuti domestici. Avete la responsabilità di restituire tutti i vostri rifiuti da apparecchiature elettriche o elettroniche lasciandoli in un punto di raccolta dedicato al loro riciclo.
SMANTELLAMENTO
Nel caso l’automazione venga smontata per essere poi rimontata in altro sito bisogna: -Togliere l’alimentazione e scollegare tutto l’impianto elettrico.
-Togliere l’attuatore dalla base di fissaggio.
-Smontare tutti i componenti dell’installazione.
-Nel caso alcuni componenti non possano essere rimossi o risultino danneggiati, provvedere alla loro sostituzione.
LE DICHIARAZIONI DI CONFORMITÀ SONO CONSULTABILI NEL SITO WEB: http://www.bft-automation.com/CE LE ISTRUZIONI DI MONTAGGIO ED USO SONO CONSULTABILI NELLA SEZIONE DOWNLOAD.
Tutto quello che non è espressamente previsto nel manuale d’installa zione, non è permesso. ll buon funzionamento dell’operatore è garantito solo se vengono rispettati i dati riportati. La ditta non risponde dei danni causati dall’inosservanza delle indicazioni riportate in questo manuale.
Lasciando inalterate le caratteristiche essenziali del prodotto, la Ditta si riserva di apportare in qualunque momento le modifiche che essa ritiene convenienti per migliorare tecnicamente, costruttivamente e commercialmente il prodotto, senza impegnarsi ad aggiornare la presente pubblicazione.
D811766_16
INSTALLER WARNINGS WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein. Uses other than those indicated herein might cause damage to the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2014/30/EC, 2014/35/ EC, 2006/42/EC, 2011/305/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in ad dition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code.
- Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general in accordance with the provisions of standards EN 12604 and 12453 or any local installation standards. Check that the existing structure meets the necessary strength and stability requirements.
- Before commencing installation, check the product for damage.
- The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use. - Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system.
Also disconnect buffer batteries, if any are connected.
- Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fitted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation that provide full disconnection under overvoltage category III conditions.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Impact forces can be reduced by using deformable edges.
- In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the instal lation environment, the operating logic of the system and forces generated by the automated system.
- Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identified in compliance with the provisions of standard EN 13241-1.
- Once installation is complete, apply a nameplate featuring the door/gate’s data.
- This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed).
- If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
- For roller shutter automation only 1) The motor’s moving parts must be installed at a height greater than 2.5 m above the floor or other surface from which they may be reached.
2) The gearmotor must be installed in a segregated and suitably protected space so that it cannot be reached without the aid of tools.
- Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public.
- Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure. - Attach a label near the operating device, in a permanent fashion, with informa tion on how to operate the automated system’s manual release.
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts.
- Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm dis claims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
- Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manu ally in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accord ance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
WIRING WARNING!
For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.5mm
2 or 4x1.5mm
2 when dealing with three phase power supplies or 3x1.5mm
2 for single-phase supplies (by way of example, type H05RN-F cable can be used with a cross-sectional area of 4x1.5mm
2 ). To con nect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm 2 .
- Only use pushbuttons with a capacity of 10A-250V or more.
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.
- During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING!
live parts.
safety extra low voltage wires must be kept physically separate from low voltage wires.
Only qualified personnel (professional installer) should be allowed to access
CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE
Before the automated system is finally put into operation, and during maintenance work, perform the following checks meticulously: - Make sure all components are fastened securely.
- Check starting and stopping operations in the case of manual control.
- Check the logic for normal or personalized operation.
- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play along the full length of the rack; keep the track the gate slides on clean and free of debris at all times.
- For sliding gates and doors only: make sure the gate’s running track is straight and horizontal and that the wheels are strong enough to take the weight of the gate.
- For cantilever sliding gates only: make sure there is no dipping or swinging during operation.
- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.
-For barriers only: before opening the door, the spring must be decompressed (vertical boom).
- Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
- Impact forces can be reduced by using deformable edges.
- Make sure that the emergency operation works, where this feature is provided.
- Check opening and closing operations with the control devices applied.
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged.
- While performing maintenance, clean the photocells’ optics.
- When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually.
- If the power cord is damaged, it must be replaced by the manufacturer or their technical assistance department or other such qualified person to avoid any risk .
- If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months - The maintenance described above must be repeated at least once yearly or at shorter intervals where site or installation conditions make this necessary.
WARNING!
Remember that the drive is designed to make the gate/door easier to use and will not solve problems as a result of defective or poorly performed installation or lack of maintenance
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and electronic equipment to a suitable recycling centre.
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to: - Cut off the power and disconnect the whole electrical system.
- Remove the actuator from the base it is mounted on.
- Remove all the installation’s components.
- See to the replacement of any components that cannot be removed or happen to be damaged.
DECLARATIONS OF CONFORMITY CAN BE FOUND AT http://www.bft automation.com/CE LOAD SECTION.
INSTRUCTIONS FOR USE AND ASSEMBLY CAN BE FOUND IN THE DOWN Anything that is not explicitly provided for in the installation ma nual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
D811766_16 THALIA P - 9
I
NSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE
A
220
B
0,75 0,75 0,75 0,75 * Vedere specifica motore See motor specifications Consultez les caractéristiques du moteur Siehe Motordaten Véase especificaciones motor Zie motorspecificatie 0,75 125 JP21 24V 8888
C
SHIELD ANT Connettore programmatore palmare, Palmtop programmer connector, Connecteur programmateur de poche, Steckverbinder Palmtop-Programmierer, Conector del programador de bolsillo, Connector programmeerbare palmtop.
24V
220 230V (*) 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 * Altre tensioni disponibili a richiesta Other voltages available on request Autres tensions disponibles sur demande Weitere Spannungen auf Anfrage erhältlich Otras tensiones disponibles a petición Andere spanningen op aanvraag beschikbaar L N 10 11 14 15 20 21 22 23 24 25 26 27 28 29 40 41 42 43 44 45 50 51 52 60 61 62 63 64 65 Display + tasti programmazione Display + programming keys Display + Programmierungstasten Pantalla + botones programación Display + programmeringstoetsen L N 10 11 14 15 20 21 22 23 24 25 26 27 28 29 40 41 42 43 44 45 AUX 3 = 1
1
L N *
M1 M2
Alimentazione Power supply Alimentation Stromversorgung Alimentación /Voeding Motore / Motor moteur/Motor Eindaanslag/Motor AUX 12/24V 50 51 52 60 61 62 63 64 65 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 26 27 26 27 50 51 Collegamento di 1 coppia di fotocellule non verificate, Connection of 1 pair of non-tested photocells, Connexion 1 paire photocellules no vérifiées, Anschluss von einem Paar nicht überprüften Fotozellen, Conexión de 1 par fotocélulas no comprobadas, Aansluiting van 1 paar fotocellen anders dan “trusted device”.
D
SAFE 1 = 0 50 51 70 72 1 2 TX1 RX1 1 2 3 4 5 14 THALIA P
E’ NECESSARIO SEGUIRE QUESTA SEQUENZA DI REGOLAZIONI:
1 - Regolazione dei finecorsa 2 - Autoset 3 - Programmazione radiocomando 4 - Eventuali regolazioni dei parametri / logiche Dopo ogni modifica della posizione dei finecorsa e’ necessario eseguire un nuovo autoset.
Dopo ogni modifica del tipo motore e’ necessario eseguire un nuovo autoset. Se si utilizza il menu semplificato: - Nel caso di motori LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 la fase 1 (regolazione finecorsa) e’ compresa nel menu semplificato. - Negli altri motori la fase 1 (regolazione finecorsa) va eseguita prima di attivare il menu semplificato.
ENGLISH IT IS NECESSARY TO FOLLOW THIS SEQUENCE OF ADJUSTMENTS:
1 - Adjusting the limit switches 2 - Autoset 3 - Programming remote controls 4 - Setting of parameters/logic, where necessary After each adjustment of the end stop position a new autoset is required. After each modification of the motor type, a new autoset must be carried out If the simplified menu is used: - In LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 motors: phase 1 (end stop adjustment) is included in the simplified menu. - In other motors: phase 1 (end stop adjustment) must be carried out before activating the simplified menu
FRANÇAIS VOUS DEVEZ OBLIGATOIREMENT SUIVRE CETTE SÉQUENCE DE RÉGLAGES:
1 - Réglage des fins de course 2 - Réglage automatique (autoset) 3 - Programmation de la radiocommande 4 - Réglages éventuels des paramètres / logiques Chaque fois que vous modifiez la position des fins de course vous devez procéder à un nouveau autoset. Chaque fois que vous modifiez le type de moteur vous devez procéder à un nouveau autoset.
Si vous utilisez le menu simplifié: - Avec les moteurs LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 la phase 1 (réglage fins de course) est comprise dans le menu simplifié. - Avec les autres moteurs vous devez accomplir la phase 1 (réglage fins de course) avant d’activer le menu simplifié.
DEUTSCH DIESE SEQUENZ DER EINSTELLUNGEN MUSS BEFOLGT WERDEN:
1 - Einstellung der endschalter 2 - Autoset 3 - Programmierung fernbedienung 4 - Eventuelle einstellungen der parameter / logiken Nach jeder änderung der position der endschalter musse in neuer autoset ausgeführt werden. Nach jeder änderung des motortyps muss ein neuer autoset ausgeführt werden.
wenn das vereinfachte menü benutzt wird: - Bei den motoren LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 ist die phase 1 (einstellung endschalter) im vereinfachten menü enthalten. - Bei den anderen motoren wird die phase 1 (einstellung endschalter) ausgeführt, bevor das vereinfachte menü aktiviert wird.
ESPAÑOL ES NECESARIO SEGUIR ESTA SECUENCIA DE AJUSTES:
1 - Regulación de los finales de carrera 2 - Autoset 3 - Programación de radiomando 4 - Eventuales regulaciones de los parámetros / lógicas Después de cambiar la posición de los interruptores de tope es necesario realizar un nuevo autoset. Después de cambiar el tipo de motor es necesario realizar un nuevo autoset. Si se utiliza el menú simplificado: - En caso de motores LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 la fase 1 (ajuste de interruptor de tope) está comprendida en en menú simplificado. - En los otros motores la fase 1 (ajuste de interruptor de tope) se debe realizar antes de activar el menú simplificado.
NEDERLANDS VERRICHT DE VOLGENDE REGELINGEN:
1 - Regeling van de eindaanslagen 2 - Autoset 3 - Programmering afstandsbediening 4 - Eventuele regelingen van de parameters / logica’s Verricht na elke wijziging van de positie van de eindaanslagen een nieuwe autoset. Dna elke wijziging van het motortype moet een nieuwe autoset worden verricht. Als het vereenvoudigde menu wordt gebruikt: - In het geval van de motoren LUX-BT - LUX G-BT - GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 is de fase 1 (regeling eindaanslag) opgenomen in het vereenvoudigde menu. - In alle andere motoren moet de fase 1 (regeling eindaanslag) worden verricht alvorens het vereenvoudigde menu te activeren. THALIA P - 15
M2
inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
M1 M1 ELI 250 BT
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
1 E M2 ELI 250 BT
Potenza massima - Maximum power - Puissance maximum Max. Leistung - Potencia máxima - Maximum vermogen
175W
Ciclo massimo - Maximum cycle - Cycle maximum Max. Zyklus - Ciclo máximo - Maximale cyclus
S3 15s-1-15s-1 x25
pausa -pause - pause pause - pausa - pauze
90min.
inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
10 11 14 15 40 41 42 43 44 45
M1 M2 M1
M1 M2
M2 M2 M1
inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
PHOBOS N BT
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
2 PHOBOS BT
Potenza massima - Maximum power - Puissance maximum Max. Leistung - Potencia máxima - Maximum vermogen
40W
Ciclo massimo - Maximum cycle - Cycle maximum Max. Zyklus - Ciclo máximo - Maximale cyclus
S3 13s-1-13s-1 x30
pausa -pause - pause pause - pausa - pauze
90min. M1 M1 M2
10 11 14 15 40 41 42 43 44 45 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
M1 M2
M1 M2 M2 M2 M1
SW 1 M1 + M1 SW 2 M2 + M2 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
M2 M1
inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
IGEA BT
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
3 IGEA BT
Potenza massima - Maximum power - Puissance maximum Max. Leistung - Potencia máxima - Maximum vermogen
40W
Ciclo massimo - Maximum cycle - Cycle maximum Max. Zyklus - Ciclo máximo - Maximale cyclus
S3 15s-1-15s-1 x12
pausa -pause - pause pause - pausa - pauze
173min.
10 11 14 15 40 41 42 43 44 45
M1
16 THALIA P
M2
M1 M2
M1
SW 1 M1 + M1-
M2
SW 2 M2 + M2-
LUX BT
tipo motore - type de moteur - motorentyp - motor type - tipo motor:
4 LUX G BT
tipo motore - type de moteur - motorentyp - motor type - tipo motor:
5
Potenza massima - Maximum power - Puissance maximum - Max. Leistung - Potencia máxima - Maximum vermogen Ciclo massimo - Maximum cycle - Cycle maximum - Max. Zyklus - Ciclo máximo - Maximale cyclus
LUX BT 90W S3 10s-5-14s-5 x40
pausa -pause - pause pause - pausa - pauze
LUX G BT 90W S3 10s-5-14s-5 x40
pausa -pause - pause pause - pausa - pauze
E
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung / inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
M2 M1 M1
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung / inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
M2
10 11 14 15 M1 M2
M1
40 41 42 43 44 45
M2
M2 - + REF SWE reg. fc. - l.sg adj - regl.fc - endsche inst
M1 M2 M2 M1 1 SUB BT
tipo motore - type de moteur - motorentyp - motor type - tipo motor:
6
Potenza massima - Maximum power - Puissance maximum - Max. Leistung - Potencia máxima - Maximum vermogen Ciclo massimo - Maximum cycle - Cycle maximum - Max. Zyklus - Ciclo máximo - Maximale cyclus
SUB BT 90W S3 17s-1-17s-1 x21
pausa -pause - pause pause - pausa - pauze
47 min. 2
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung / inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
10 11 14 15 40 41 42 43 44 45
M2 M1 M1
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
M2 M1 M2 M2 M1
M1 M2 *Bianco **Rosso ***Nero *Bianco White Blanc Weiß Blanco Wit **Rosso Red Rouge Rot Rojo Rood ***Nero Black Noir Nero Negro Zwart THALIA P - 17
M2 PHOBOS BT A / KUSTOS BT A
tipo otore - type de oteur - otorentyp - otor type - tipo otor
7
inv.direz. ap / open in other direct. / inv.sens.ouv inv richt offnung / inv.direcc.ap. / Omkering openingsrichting:
0 (
int
)
E PHOBOS BT A
Potenza massima - Maximum power - Puissance maximum - Max. Leistung - Potencia máxima - Maximum vermogen -
40W
Ciclo massimo - Maximum cycle - Cycle maximum - Max. Zyklus - Ciclo máximo - Maximale cyclus -
S3 13s-1-13s-1 x30
pausa -pause - pause pause - pausa - pauze
90min. KUSTOS BT A 40W S3 13s-1-13s-1 x30
pausa -pause - pause pause - pausa - pauze
90min.
M1 M1 M2
10 11 14 15 40 41 42 43 44 45 inv.direz. ap / open in other direct. / inv.sens.ouv inv richt offnung / inv.direcc.ap. / Omkering openingsrichting:
1 (
ext
)
M1 M2
M1
SW 1 M1 + M1-
M2
SW 2 M2 + M2-
M1 M2 M2 M1 GIUNO ULTRA
tipo motore - type de moteur - motorentyp - motor type - tipo motor:
8
Potenza massima - Maximum power - Puissance maximum - Max. Leistung - Potencia máxima - Maximum vermogen Ciclo massimo - Maximum cycle - Cycle maximum - Max. Zyklus - Ciclo máximo - Maximale cyclus ANTA MAX/ LEAF MAX/ VANTAIL MAXI/ FLÜGEL MAX./ HOJA MÁX./ VLEUGEL MAX.
TIPO DI UTILIZZO / TYPE OF USE - SEMI-INTENSIVE / TYPE D’UTILISATION BENUTZUNGSTYP - HALBINTENSIV / TIPO DE USO / SOORT GEBRUIK - SEMI-INTENSIEF
GIUNO ULTRA BT A 20 90W GIUNO ULTRA BT A 50 90W S3 10s-5-14s-5 x40
pausa -pause - pause pause - pausa - pauze
300 kg S3 10s-5-14s-5 x40
pausa -pause - pause pause - pausa - pauze
300 - 800 kg 2 m 5 - 2 m molto intensivo / very intensive / très intense / sehr intensiv / muy intensivo / hoog intensief
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 (
int
)
10 11 14 15 40 41 42 43 44 45
M2 M1 M1
inv.direz. ap / open in other direct. / inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 (
ext
)
M2
M1 M2
M1 M2
M2 - - REF SWE reg. fc. - l.sg adj - regl.fc - endsche inst
M1 M2 M2 M1 1 2 ATTENZIONE:
con attuatori con fermi integrati è obbligatorio il rallentamento sempre attivo ad un valore superiore a 5.
ATTENTION:
with actuators with integrated locks, the permanently active slowdown to a value higher than 5 is mandatory.
ATTENTION:
avec des actionneurs à butées intégrées il est obligatoire que le ralentissement soit toujours actif à une valeur supérieure à 5.
ACHTUNG:
Bei Aktuatoren mit integrierten Feststellern ist eine immer aktive Verlangsamung bei einem Wert über 5 zwingend erforderlich.
ATENCIÓN:
con accionadores con topes integrados la deceleración debe estar siempre activa a un valor superior a 5.
OPGELET:
met ingebouwde, stilstaande actuatoren moet de afremming altijd geactiveerd zijn op een waarde hoger dan 5.
18 THALIA P lang x1 tipo n. mot.
Dir preset
LUX BT / LUX G BT
reg. fc.
autoset mem.telec
fine
MENU SEMPLIFICATO
ITA fra deu eng esp eli phobos BT A phobos N .....
2 1 int EXT AR sr ac sc ind INT : apertura verso l’interno EXT : apertura verso l’esterno ar : funzionamento automatico, residenziale sr : funzionamento semi-aut., residenziale ac : funzionamento automatico, condominiale Sc : funzionamento semi-automatico, condominiale Ind : funzionamento a uomo presente o
2 2 2 2
opm1
1
: regolazione finecorsa di apertura motore 1 opm2 clm2 clm1 ersu o o
1 1 1
: regolazione finecorsa di apertura motore 2 : regolazione finecorsa di chiusura motore 2 : regolazione finecorsa di chiusura motore 1 fine . . . . . .
ovi ento anuale
2 2 GIUNO ULTRA
reg. fc.
MIN 1 - MAX 3 AUTO OPEN AUTO CLOSE ELI BT / KUSTOS BT A / PHOBOS BT A PHOBOS N BT / IGEA BT / SUB BT 1 1
: regolazione finecorsa di apertura motore 1 e 2 : regolazione finecorsa di chiusura motore 1 e 2 Fare riferimento alle impostazioni sulla regolazione dei finecorsa riportate nel manuale del motore GIUNO ULTRA.
o tasto nascosto rilascia tasto desiderato O 01
x1 language type n. mot.
Dir preset
LUX BT / LUX G BT
l.sw adj autoset
SIMPLIFIED MENU
ITA fra deu eng esp eli phobos BT A phobos N .....
2 1 int EXT AR sr ac sc ind Scroll up Scroll down Exit Menù
PRESET PARAMETERS LOGIC
TCA Step-by-step movement Pre-alarm Deadman Block pulses during opening
DEFAULT
ar sr ac sc ind 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 1 0 1 1 1 0 0 1 0 1 0 0 0 1 0 INT : inward opening EXT : outward opening ar : automatic operation, residential sr : semiautomatic operation, residential ac : automatic operation, commercial Sc : semiautomatic operation, commercial Ind : dead man operation o
2 2 2 2
opm1
1
: motor 1 opening limit switch adjustment opm2
1
: motor 2 opening limit switch adjustment clm2 clm1 ersu o o
1 1
: motor 2 closing limit switch adjustment : motor 1 closing limit switch adjustment end . . . . . .
2 2 GIUNO ULTRA
reg. fc.
MIN 1 - MAX 3 AUTO OPEN AUTO CLOSE ELI BT / KUSTOS BT A / PHOBOS BT A PHOBOS N BT / IGEA BT / SUB BT 1
: motor 1/2 opening limit switch adjustment
1
: motor 1/2 closing limit switch adjustment Refer to the settings on the adjustment of the limit switches found in the GIUNO ULTRA motor manual.
o release desidered button O 01 20 THALIA P mem.remotes
end hidden button
51 52 72 76 77 78 79 80 81 82 83 84 85
F
1 2 51 50 1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 1
3 1 2 1 2 3 4 5 1 2 3 4 5 51 50 70 72 4 52 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5 51 50 70 73 72 1 BAR / 1 BAR OP / 1 BAR CL 51 72 70 50 51 6 5 4 3 2 1 6 5 4 3 2 1 1 BAR / 1 BAR OP / 1 BAR CL 52 72 73 70 50 51 6 5 3 2 1 5 52 50 52 50 70 72 2 PHOT / 2 PHOT OP / 2 PHOT CL 1 2 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 70 72 51 50 73 70 2 BAR / 2 BAR OP / 2 BAR CL 52 72 70 50 51 6 5 4 3 2 1 52 70 73 50 51 6 5 4 3 2 1 6 5 4 3 2 1 SAFETY EDGE BAR 8K2 / BAR 8K2 OP / BAR 8K2 CL SAFETY EDGE 8,2Kohm 5% 1 2
SAFE 3
1 PHOT / 1 PHOT OP / 1 PHOT CL 51 50 1 2 52 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 76 77 51 50 76 78 77 52 50 52 50 2 PHOT / 2 PHOT OP / 2 PHOT CL 1 2 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 76 77 51 50 78 76 3 4 1 BAR / 1 BAR OP / 1 BAR CL 51 77 76 50 51 6 5 3 2 1 1 BAR / 1 BAR OP / 1 BAR CL 52 77 78 76 50 51 6 5 3 2 1 2 BAR / 2 BAR OP / 2 BAR CL 52 77 76 50 51 3 2 1 6 5 4 52 76 78 50 51 6 5 4 3 2 1 6 5 4 3 2 1 1 2
SAFE 5
1 PHOT / 1 PHOT OP / 1 PHOT CL 51 50 1 2 52 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 81 82 51 50 81 83 82 3 4 52 50 2 PHOT / 2 PHOT OP / 2 PHOT CL 1 2 52 50 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 81 82 51 50 83 81 1 BAR / 1 BAR OP / 1 BAR CL 51 82 81 50 51 6 5 3 2 1 1 BAR / 1 BAR OP / 1 BAR CL 52 82 83 81 50 51 6 5 3 2 1 2 BAR / 2 BAR OP / 2 BAR CL 52 82 81 50 51 3 2 1 6 5 4 52 81 83 50 51 6 5 4 3 2 1 6 5 4 3 2 1 1 51 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5
SAFE 2
51 50 70 74 3 1 BAR / 1 BAR OP / 1 BAR CL 51 74 70 50 51 6 5 4 3 2 1 6 5 4 3 2 1 2 5 52 50 52 50 52 50 70 74 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 2 PHOT / 2 PHOT OP / 2 PHOT CL 1 2 1 2 SAFETY EDGE 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 70 74 51 50 75 70 51 50 70 75 74 4 1 BAR / 1 BAR OP / 1 BAR CL 52 74 75 70 50 51 6 5 4 3 2 1 2 BAR / 2 BAR OP / 2 BAR CL 52 70 75 50 51 52 74 70 50 51 BAR 8K2 / BAR 8K2 OP / BAR 8K2 CL SAFETY EDGE 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 8,2Kohm 5% 1 2 51 50 1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 4
3 1 2 1 2 3 4 5 1 2 3 4 5 51 50 76 79 4 52 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5 51 50 76 80 79 2 PHOT / 2 PHOT OP / 2 PHOT CL 52 50 1 2 52 50 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 76 79 51 50 80 76 1 BAR / 1 BAR OP / 1 BAR CL 51 79 76 50 51 6 5 4 3 2 1 1 BAR / 1 BAR OP / 1 BAR CL 52 79 80 76 50 51 6 5 3 2 1 2 BAR / 2 BAR OP / 2 BAR CL 52 79 76 50 51 6 5 4 2 1 52 76 80 50 51 3 2 1 6 5 4 1 2 51 50 1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 6
3 1 2 1 2 3 4 5 1 2 3 4 5 51 50 81 84 4 52 50 1 PHOT / 1 PHOT OP / 1 PHOT CL 1 2 1 2 3 4 5 1 2 3 4 5 51 50 81 85 84 2 PHOT / 2 PHOT OP / 2 PHOT CL 52 50 1 2 52 50 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 51 50 81 84 51 50 85 81 1 BAR / 1 BAR OP / 1 BAR CL 51 84 81 50 51 6 5 4 3 2 1 1 BAR / 1 BAR OP / 1 BAR CL 52 84 85 81 50 51 6 5 3 2 1 2 BAR / 2 BAR OP / 2 BAR CL 52 84 81 50 51 3 2 1 6 5 4 52 81 85 50 51 3 2 1 6 5 4 THALIA P - 25
A OPEN B OPEN UNIDA C G D H
ON ON OFF OFF
1
70 71 STOP
!
+ EXPANSION BOARD ERWEITERUNGSKARTE TARJETA DE EXPANSIÓN UITBREIDINGSKAART
Programmeerbare Universele Palmtop (versione x.40 e successive) (x.40 and later versions) (version x.40 et suivantes) (Version x.40 und nachfolgende) (versión x.40 y sucesivas ) (versie x.40 en hoger)
2 4 I
8888
+ S1 S2 OK S3
ON ON OFF OFF
3 <3s
rst 8
+ S1 S2 OK S3
.
.
.
.
+ S1 S2 OK S3 5
8888
+ S1 S2 OK S3 6
26 THALIA P
x2 *** 0-- ALT 10- follow the user guide 150 1520 ok
See PARAMETERS MENU
*** Password entry.
Request with Protection Level logic set to 1, 2, 3, 4 Scroll up Scroll down Confirm/Switch on display Exit Menù
See LOGIC MENU
add. start Add. 2ch erase 64 hidden butt hidden butt release desired button release desired button
See RADIO MENU
language autoset l.sw adj stat password 36 THALIA P
LUX BT / LUX G BT
opm1
2 2 2 2
opm2 clm2 clm1 ersu o
1 1 1 1
+ / -
GIUNO ULTRA
Manual movement
2 2 1 1
vers - + n. cycles OK bft . . .
+ / No total manoeuvres(in hundreds) OK 0000 + / - + n. remotes - + err No radio controldevices memorised OK 00 + / List of last 30 errors OK 01.33
02.01
........
30.15
+ / 0-- 10- 35.40
Instantaneous force motor 2 Instantaneous force motor 1
Diagnostics code
STRE STRI OPEN CLS PED TIME STOP
DESCRIPTION
START E external start input activated START I internal start input activated OPEN input activated CLOSE input activated PED pedestrian input activated TIMER input activated STOP input activated PHOT PHOP PHCL BAR baro verified photocell, Activation of the associated FAULT input configured as active verified photocell only when opening, Activation of the associated FAULT input Activation of PHOT CL closing photocell input or, if configured the associated FAULT input Activation of BAR safety edge input or, if configured as verified safety edge, Activation of the associated FAULT input Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE OPENING, or, if configured as verified safety edge active only while opening, Activation of the associated FAULT input Activation of BAR safety edge input with ACTIVE reversal ONLY barc SWC1 SWO1 SWC2 SWO2 SET SWC1 motor 1 closing limit switch input activated SWO1 motor 1 opening limit switch input activated SWC2 motor 2 closing limit switch input activated SWO2 motor 2 opening limit switch input activated The board is standing by to perform a complete opening closing cycle uninterrupted by intermediate stops in order ER01 ER02 ER03 ER04 er06 ER07 ER08 ER1x
*
Photocell test failed Safety edge test failed Opening photocell test failed Closing photocell test failed 8k2 safety edge test failed Opening safety edge test failed Closing safety edge test failed Board hardware test error
NOTES
Check photocell connection and/or logic settings Check safety edge connection and/or logic settings Check photocell connection and/or parameter/logic setting Check photocell connection and/or parameter/logic setting Check safety edge connection and/or parameter/logic settings Check safety edge connection and/or parameter/logic settings Check safety edge connection and/or parameter/logic settings ER2x
*
ER3x
*
ER4x
*
ER5x
*
ER7x
*
ERf3 ERF9 Ersw Encoder error Reverse due to obstacle - Amperostop Thermal cutout Communication error with remote devices Internal system supervision control error.
Error in setting the SAFE inputs Solenoid lock output overload - Motor power or encoder signal cables inverted/disconnected.
to programmed operation.
Check for obstacles in path Allow automated device to cool devices and/or expansion boards Try switching the board off and back on again. If the prob lem persists, contact the technical assistance department.
Check the setting of the SAFE inputs is correct -Check lock connections - Unsuitable lock - Repeat the limit switch adjustment procedure. - Try moving the maximum limits of both the opening 150-
*
X
= 0, 1, .., 9, A, B, C, D, E, F
1520 prg
x2 *** 0-- ALT 10- follow the user guide 150-
ACCESS MENUS Fig. 1
1520 ok
See PARAMETERS MENU
*** Password entry.
Request with Protection Level logic set to 1, 2, 3, 4 Scroll up Scroll down Confirm/Switch on display Exit Menù
See LOGIC MENU
add. start Add. 2ch erase 64 hidden butt hidden butt release desired button release desired button
See RADIO MENU
language autoset l.sw adj stat password
LUX BT / LUX G BT
opm1
2 1
opm2
2 1
clm2
2 1
clm1 -
2 1
ersu o + / -
GIUNO ULTRA
Manual movement
2 2 1 1
vers - + n. cycles OK bft . . .
+ / No total manoeuvres(in hundreds) OK 0000 + / - + n. remotes - + err No radio controldevices memorised OK 00 + / List of last 30 errors OK 01.33
02.01
........
30.15
+ / 0-- 10- 150 1520 prg
INSTALLATION MANUAL
2) GENERAL INFORMATION
The
THALIA P
control panel comes with standard factory settings. Any change must be made using the programmer with built-in display or universal handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are: - Control of 1 or 2 24V BT motors Note: 2 motors of the same type must be used.
- Electronic torque control with obstacle detection - Limit switch control inputs based on motor selected - Separate inputs for safety devices - Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance or replacement easier. It comes with a series of prewired jumpers to make the installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77, 76-79, 81-82, 81-84. If the above-mentioned terminals are being used, remove the rel evant jumpers.
TESTING
The
THALIA P
panel controls (checks) the start relays and safety devices (pho tocells) before performing each opening and closing cycle. If there is a malfunction, make sure that the connected devices are working properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Motor relay switching current Maximum motor power Accessories power supply AUX 0 AUX 1 AUX 2 AUX 3 LOCK Dimensions see
Fig. B
Fuses N° of combinations see
Fig. C
4 billion Max.n° of transmitters that can be memorized 63 (*other voltages to order)
Usable transmitter versions: All ROLLING CODE transmitters compatible with 4) TUBE ARRANGEMENT Fi g. A
10A 180W + 180W (24V ) NO 24V powered contact (max.1A) NO 220 230V~ powered contact (max.5A) NO contact (220-230V~/max.5A) NO contact (24V~/max.1A) Power supply Low voltage/mains insulation Operating temperature range Thermal overload protection Dielectric rigidity Motor output current 220-230V 50/60Hz(*) > 2MOhm 500V -10 / +55°C Software mains/LV 3750V~ for 1 minute max. 7.5A+7.5A
5) TERMINAL BOARD WIRING Fig. C WARNINGS -
When performing wiring and installation, refer to the standards in force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other, or they must be suitably insulated with at least 1mm of additional insulation. Wires must be secured with additional fastening near the terminals, using devices such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Terminal
L N JP5 JP7 JP21 10 11 14 15 20 21 22 23
Definition
LINE NEUTRAL TRANSF PRIM TRANSF SEC MOT1 + MOT1 MOT2 + MOT2 AUX 0 - 24V POWERED CONTACT (N.O.) (MAX. 1A) AUX 1 - 220-230V~ POWERED CONTACT (Max. 5A) Single-phase power supply 220-230V 50/60Hz(*)
Description
Transformer primary winding connection, 220-230V.
Board power supply: 24V~ Transformer secondary winding 24V= Buffer battery power supply Connection motor 1. Time lag during closing.
Check connections shown in Fig.E
Connection motor 2. Time lag during opening.
Check connections shown in Fig.E
AUX 0 configurable output - Default setting FLASHING LIGHT. 2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTENANCE. Refer to “AUX output configuration” table.
AUX 1 configurable output - Default setting ZONE LIGHT Output. 2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT/ ZONE LIGHT/ STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK. Refer to “AUX output configuration” table.
43 41 42 43 24 25 26 27 28 29 41 42 43 44 45 42 AUX 2 - FREE CONTACT (N.O.) (Max. 220-230V 5A) AUX 3 - FREE CONTACT (N.O.) (Max. 24V 1A) LOCK 12V/24 + REF SWE SWC 1 SWO 1 SWC 2 SWO 2 SW 1 SW 2 + REF SWE SW 1 SW 2 AUX 2 configurable output - Default setting SCA GATE OPEN LIGHT Output. 2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK. Refer to “AUX output configuration” table.
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output. 2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK. Refer to “AUX output configuration” table.
Type of lock logic= 0 - 12V Type of lock logic= 1 - 12V Type of lock logic= 2 - 24V Type of lock logic= 3 - 24V solenoid latch output (max. 30W). Output activated with a pulse each time gate is opened.
magnetic lock output (max. 15W). Output activated when gate is closed.
solenoid latch output (max. 30W). Output activated with a pulse each time gate is opened.
magnetic lock output (max. 15W). Output activated when gate is closed.
Limit switch common Motor 1 closing limit switch SWC1 (N.C.).
Motor 1 opening limit switch SWO1 (N.C.).
Motor 2 closing limit switch SWC2 (N.C.).
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch control motor 1. For actuators with single-wire limit switch control.
Limit switch control motor 2. For actuators with single-wire limit switch control.
Limit switch common Limit switch control motor 1. Limit switch control motor 2. THALIA P - 37
Terminal
40
Definition
- REF SWE
INSTALLATION MANUAL
Description
Limit switch common 42 SW 1 Limit switch control motor 1. 75 76 77 78 79 80 81 82 83 84 85 Y # 72 73 74 65 70 71 62 63 64 43 50 51 52 60 61 SW 2 24V 24V+ 24 Vsafe+ Common IC 1 IC 2 Common IC 3 IC 4 Common STOP SAFE 1 FAULT 1 SAFE 2 FAULT 2 Common SAFE 3 FAULT 3 SAFE 4 FAULT 4 Common SAFE 5 FAULT 5 SAFE 6 FAULT 6 ANTENNA SHIELD Limit switch control motor 2. Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter). Output active only during operating cycle.
IC 1 and IC 2 inputs common Configurable command input 1 (N.O.) - Default START E. START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED Refer to the “Command input configuration” table.
Configurable command input 2 (N.O.) - Default PED. START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED Refer to the “Command input configuration” table.
IC 3 and IC 4 inputs common Configurable command input 3 (N.O.) - Default OPEN. START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED Refer to the “Command input configuration” table.
Configurable command input 4 (N.O.) - Default CLOSE. START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED Refer to the “Command input configuration” table.
STOP, SAFE 1 and SAFE 2 inputs common The command stops movement. (N.C.) If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2/ BAR OP / BAR OP TEST / BAR 8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 C L.
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2/ BAR OP / BAR OP TEST / BAR 8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 2.
SAFE 3 and SAFE 4 inputs common Configurable safety input 3 (N.C.) - Default PHOT OP. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR/TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST / Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 3.
Configurable safety input 4 (N.C.) - Default PHOT CL. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR/TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST / Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 4.
SAFE 5 and SAFE 6 inputs common Configurable safety input 5 (N.C.) - Default PHOT. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR/TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST / Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 5.
Configurable safety input 6 (N.C.) - Default BAR. PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR/TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST / Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 6.
Antenna input. Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
AUX output configuration
Aux logic= 0 - 2ND RADIO CHANNEL output. Contact stays closed for 1s when 2nd radio channel is activated. Aux logic= 1 - SCA GATE OPEN LIGHToutput. Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output. Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIGHT command output. Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIGHT output. Contact stays closed for 1 second at start of operation. Aux logic= 5 - GATE OPEN ALARM output. Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHING LIGHT output. Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output. Contact stays closed for 2 seconds each time gate is opened. Aux logic= 8 - MAGNETIC LOCK output. Contact stays closed while gate is closed.
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required. Aux logic= 10 - FLASHING LIGHT AND MAINTENANCE output.
Contact stays closed while leaves are operating. If the value set for the Maintenance parameter is reached, once the gate has finished moving and the leaf is closed, the contact closes for 10 sec. and opens for 5 sec. 4 times to report that maintenance is required.
38 THALIA P
INSTALLATION MANUAL
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP MOV . logic. External start for traffic light control.
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP MOV . logic. Internal start for traffic light control.
IC logic= 2 - Input configured as Open. The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time, where activated.
IC logic= 3 - Input configured as Closed. The command causes the leaves to close.
IC logic= 4 - Input configured as Ped. The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP . logic IC logic= 5 - Input configured as Timer. Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input configured as Timer Ped. The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E, Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input configuration
SAFE logic= 0 - Input configured as Phot (photocell) non tested (*). (fig.F, ref.1). Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input configured as Phot test (tested photocell). (fig.F, ref.2). Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
SAFE logic= 2 - Input configured as Phot op (photocell active during opening only) non tested (*). (fig.F, ref.1). Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input configured as Phot op test (tested photocell active during opening only (fig.F, ref.2). Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photo cell beam stays broken.
SAFE logic= 4 - Input configured as Phot cl (photocell active during closing only) non tested (*). (fig.F, ref.1). Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing, move ment is reversed immediately. If not used, leave jumper inserted.
SAFE logic= 5 - Input configured as Phot cl test (tested photocell active during closing only (fig.F, ref.2). Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*). (fig.F, ref.3). Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge (fig.F, ref.4). Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2 (fig.F, ref.5). Input for resistive edge 8K2. The command reverses movement for 2 sec.
SAFE logic=9 Input configured as Bar op, safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop. If not used, leave jumper inserted. SAFE logic=10 Input configured as Bar op test, safety edge checked with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 4).
Activates testing safety edges when starting operation. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=11 Input configured as Bar 8k2 op, 8k2 safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 5).
The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=12 Input configured as Bar cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=13 Input configured as Bar cl test, safety edge checked with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 4). Activates testing safety edges when starting operation. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
SAFE logic=14 Input configured as Bar 8k2 cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 5).
The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
(*) If “D” type devices are installed (as defined by EN12453), connect in un verified mode, foresee mandatory maintenance at least every six months.
6) MOTOR WIRING Fig. E 7) SAFETY DEVICES Note: only use receiving safety devices with free changeover contact.
8) CALLING UP MENUS: FIG. 1 8.1) PARAMETERS MENU (
PARA
) (PARAMETERS TABLE “A”) 8.2) LOGIC MENU (
LOGIC
) (LOGIC TABLE “B”) 8.3) RADIO MENU (
radio
) (RADIO TABLE “C”) - IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features: • Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
To use these advanced features, refer to the universal handheld programmer’s instructions and to the general receiver programming guide.
8.4) DEFAULT MENU (
default
)
Restores the controller’s DEFAULT factory settings. Following this reset, you will need to run the AUTOSET function again.
8.5) LANGUAGE MENU (
language
)
Used to set the programmer’s language on the display.
8.6) AUTOSET MENU (
AUTOset
)
• • Launch an autoset operation by going to the relevant menu.
As soon as you press the OK button, the “.... .... ....” message is displayed and the control unit commands the device to perform a full cycle (opening followed by closing), dur ing which the minimum torque value required to move the leaf is set automatically.
The number of cycles required for the autoset function can range from 1 to 3.
During this stage, it is important to avoid breaking the photocells’ beams and not to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the optimum torque values. Check them and, where necessary, edit them as described in the programming section.
WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Impact forces can be reduced by using deformable edges.
Warning!! While the autoset function is running, the obstacle detection of range of the automated system.
8.7)INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*) 2. Check the impact forces: if they fall within the limits (**) skip to point 10 of the procedure, otherwise 3. Where necessary, adjust the speed and sensitivity (force) parameters: see parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise 5. Apply a shock absorber profile 6. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise 7. Apply pressure-sensitive or electro-sensitive protective devices (such as a safety edge) (**) 8. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise 9. Allow the drive to move only in “Deadman” mode 10. Make sure all devices designed to detect obstacles within the system’s operating range are working properly (*) Before running the autoset function, make sure you have performed all the assembly and make-safe operations correctly, as set out in the installation warnings in the drive’s manual.
(**) Based on the risk analysis, you may find it necessary to apply sensitive protective devices anyway
8.8) LIMIT SWITCH ADJUSTMENT MENU (
other cases, the “ NOT AVAILABLE L.SW ADJ
)
Used to adjust limit switches for motors featuring encoders. The menu is enabled with the following motors: LUX BT, LUX G BT, GIUNO. In all ” message is displayed. THALIA P - 39
INSTALLATION MANUAL
NOTE: these operations must be performed in deadman mode at reduced speed and without the safety devices operating. With the LUX BT/LUX G BT motors, if the “ 1 mot. Act.
” Logic is set, , only the messages regarding motor 1 (“ ULTRA motor manual.
OPm1 ” and “ CLm1 ”) will be displayed.
Refer to the settings on the adjustment of the limit switches found in the GIUNO
8.9) STATISTICS MENU
Used to view the version of the board, the total number of operations (in hundreds), the number of transmitters memorized and the last 30 errors (the first 2 digits indicate the position, the last 2 give the error code). Error 01 is the most recent.
8.10) PASSWORD MENU
Used to set a password for the board’s wireless programming via the U-link network.
With “PROTECTION LEVEL” logic set to 1,2,3,4, the password is required to access the programming menus. After 10 consecutive failed attempts to log in, you will need to wait 3 minutes before trying again. During this time, whenever an attempt is made to log in, the display will read “BLOC”. The default password is 1234.
10) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD PROGRAMMER VERSION> V1.40 (Fig. H)
Refer to specific manual.
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules. The use of some models causes lowered radio capacity. Adjust the system using an appropriate antenna tuned to 433MHxz.
12) RESTORING FACTORY SETTINGS (Fig.I) WARNING:
this operation will restore the control unit’s factory settings and all transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to people and animals. - Cut off power to the board (Fig.I ref.1) - Open the Stop input and press the - and OK keys together (Fig.I ref.2) - Switch on the board’s power (Fig.I ref.3) - The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.I ref.4) - Wait for the procedure to finish (Fig.I ref.5) - Procedure finished (Fig.I ref.6)
WARNING! Incorrect settings can result in damage to property and injury to people WARNING: Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Impact forces can be reduced by using deformable edges.
For best results, it is advisable to run the autoset function with the motors idle (i.e. not overheated by a considerable number of consecutive operations).
TABLE “A” - PARAMETERS MENU - (
PARA
) Parameter min. max. Default Personal Description Definition Motor 2 opening delay time [s]
Motor 2 opening delay time with respect to motor 1.
OPEN DELAY TI E
0 10 3
CLS DELAY TI E TCA TRF.LGHT.CLR.T
0 0 1 25 120 180 3 10 40 Motor 1 closing delay time [s] Automatic closing time [s] Time-to-clear traffic light zone [s]
Motor 1 closing delay time with respect to motor 2.
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
OP.DIST.SLOUD
CL.DIST.SLOUD
DIST.DECEL
PARTIAL OPENING OP.FORCE
CLS.FORCE
OP SPEED CL SPEED SLOW SPEED
0 0 0 10 1 1 15 15 15 50 50 50 99 99 99 99 99 99 10 10 15 99 50 50 99 99 25 Slow-down distance during opening [%] Slow-down distance during closing [%] Deceleration distance [%] Partial opening M1 [%] Leaf force during opening [%] Leaf force during closing [%] Opening speed [%} Closing speed [%] Slow-down speed [%]
Slow-down distance for motor(s) during opening, given as a percentage o f t o t a l t r a v e l .
WA R N I N G : O n ce t h e p a ra m e te r h a s b e e n e d i te d, a c o m p l e t e u n i n t e r r u p t e d o p e n i n g - c l o s i n g c y c l e i s r e q u i r e d . WARNING: when the display reads “SET”, obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
Slow-down distance for motor(s) during closing, given as a percentage o f t o t a l t r a v e l .
WA R N I N G : O n ce t h e p a ra m e te r h a s b e e n e d i te d, a c o m p l e t e u n i n t e r r u p t e d o p e n i n g - c l o s i n g c y c l e i s r e q u i r e d . WARNING: when the display reads “SET”, obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both during opening and during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: when the display reads “SET”, obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED pedestrian command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*). Install anti crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*). Install anti crush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: when the display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of maximum running speed.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: When the display reads “”SET””, obstacle detection is not active.
Maintenance
0 250 0 Programming number of operations for maintenan ce threshold [in hundreds]
Allows you to set a number of operations after which the need for maintenance will be reported on the AUX output configured as Maintenance or Flashing Light and Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
40 THALIA P
INSTALLATION MANUAL
TABLE “B” - LOGIC MENU - (
logic
) Logic
MOTOR TYPE TCA FAST CLS.
STEP-BY-STEP MOVEMNT
Definition Motor type
(Set the type of motor connected to the board).
Automatic Closing Time Fast closing Step-by-step movement Default
0 0 0 0
Cross out setting used
8 0 1 0 1 2 3 4 5 6 7 0 1 0 1 2
Optional extras
Motors not active ELI 250 BT PHOBOS N BT IGEA BT LUX BT LUX G BT SUB BT KUSTOS BT A - PHOBOS BT A GIUNO ULTRA BT A20 - GIUNO ULTRA BT A 50 Logic not enabled Switches automatic closing on Logic not enabled Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I, Ped operate with 4-step logic. Inputs configured as Start E, Start I, Ped operate with 3-step logic. Pulse during closing reverses movement.
CLOSED
step-by-step mov.
2 STEP 3 STEP 4 STEP
OPENS DURING CLOSING OPENS OPENS STOPS Inputs configured as Start E, Start I, Ped operate with 2-step logic. Move ment reverses with each pulse.
OPEN DURING OPENING CLOSES CLOSES CLOSES STOP + TCA STOP + TCA AFTER STOP OPENS OPENS OPENS PRE-ALARM HOLD-TO-RUN IBL OPEN |IBL TCA IBL CLOSE RAM BLOW C.OP
RAM BLOW C.CL
BLOC PERSIST PRESS SWC
Pre-alarm Deadman Block pulses during opening Block pulses during TCA Block pulses during closing Hammer during opening Hammer during closing Stop maintenance Closing limit switch pressure
0 0 0 0 0 0 0 0 0 0 1 0 1 2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode. Input 61 is configured as OPEN UP. Input 62 is configured as CLOSE UP. Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation. If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released. Input 61 is configured as OPEN UP. Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse from inputs configured as Start E, Start I, Ped has effect during opening. Pulse from inputs configured as Start E, Start I, Ped has no effect during opening. Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause. Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause. Pulse from inputs configured as Start E, Start I, Ped has effect during closing. Pulse from inputs configured as Start E, Start I, Ped has no effect during closing. Logic not enabled Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in the direction of the stop for approx. 3 seconds. This operation is performed every hour. NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position. This function allows leaves to press against the mechanical stop without the Amperostop sensor inter preting this as an obstacle. Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing limit switches to trip slightly earlier (Fig.G Ref.A).
THALIA P - 41
Download
Advertisement
Key features
designed for gates and doors
self-monitoring control system
protects from being crushed or sheared
prevents unauthorized access with built-in safety features
remote control
easy to install
durable and weatherproof
Frequently asked questions
At least once a year by a qualified professional
Yes, broken parts can cause uncontrolled movement of the door/gate.
Yes, always
Yes, if they are supervised and instructed