Quantum Q6 Edge 2.0/2.0X/3 Owner's Manual

Add to my manuals
28 Pages

advertisement

Quantum Q6 Edge 2.0/2.0X/3 Owner's Manual | Manualzz
USA
401 York Avenue
Duryea, PA 18642
Canada
5096 South Service Road
Beamsville, Ontario L0R 1B3
Australia
20-24 Apollo Drive
Hallam, Victoria 3803
www.quantumrehab.com.au
New Zealand
38 Lansford Crescent
Avondale
Auckland, New Zealand 1007
www.pridemobility.co.nz
UK
32 Wedgwood Road
Bicester, Oxfordshire OX26 4UL
www.quantumrehab.co.uk
B.V.
(Authorised EU Representative)
De Zwaan 3
1601 MS Enkhuizen
The Netherlands
www.quantumrehab.eu
Italy
Via del Progresso, ang. Via del Lavoro
Loc. Prato della Corte
00065 Fiano Romano (RM)
www.quantumrehab-italia.it
France
26 rue Monseigneur Ancel
69 800 Saint-Priest
www.quantumrehab.fr
Spain
Calle Velazquez 80 6D
28001 Madrid
www.quantumrehab.com
Serial #
UDI
UDILabel
Label(if(ifapplicable)
applicable)
SAFETY GUIDELINES
WARNING!
A Quantum Rehab Provider or a qualified technician
must perform the initial setup of this power chair and
must perform all of the procedures in this manual.
The symbols below are used throughout this owner’s manual
and on the power chair to identify warnings and important
information. It is very important for you to read them and
understand them completely.
WARNING!
Indicates a potentially hazardous condition/situation.
Failure to follow designated procedures can cause either
personal injury, component damage, or malfunction. On
the product, this icon is represented as a black symbol
on a yellow triangle with a black border.
MANDATORY!
These actions should be performed as specified. Failure
to perform mandatory actions can cause personal injury
and/or equipment damage. On the product, this icon is
represented as a white symbol on a blue dot with a white
border.
PROHIBITED!
These actions are prohibited. These actions should
not be performed at any time or in any circumstances.
Performing a prohibited action can cause personal
injury and/or equipment damage. On the product, this
icon is represented as a black symbol with a red circle
and red slash.
Quick Reference Information
Quantum Rehab Provider:
Address:
Phone Number:
Purchase Date:
Copyright © 2018
INFMANU4620/Rev H/April 2018
Intended Use
The intended use of the Pride Mobility Products device is to
provide mobility to persons limited to a seated position that
have the capability of operating a powered wheelchair.
Regarding Devices for Prescription Use
WARNING!
CAUTION! Federal law restricts this device to sale by or
on the order of a physician or other certified personnel
licensed by the law of the State (US only) or region in
which this personnel practices to use or order the use
of the device.
NOTE: This owner’s manual is compiled from the latest
specifications and product information available at
the time of publication. We reserve the right to make
changes as they become necessary. Any changes to
our products may cause slight variations between the
illustrations and explanations in this manual and the
product you have purchased. The latest/current version
of this manual is available on our website.
NOTE: This product is compliant with WEEE, RoHS, and
REACH directives and requirements.
NOTE: This
(IEC 60529).
product
meets
IPX4
classification
NOTE: This product and its components are not made
with natural rubber latex. Consult with the manufacturer
regarding any after-market accessories.
CONTENTS
Table of Contents
Introduction............................................................... 5
Safety......................................................................... 6
Your Power Chair...................................................... 7
Assembly................................................................. 11
Comfort Adjustments............................................. 14
Batteries and Charging.......................................... 18
Care and Maintenance........................................... 21
3
Language Usage
This owner’s manual is intended for distribution in all Englishspeaking countries where our Power Chairs are sold. We
have chosen to compose this manual using language and
spellings common to the USA. Since we recognize that not all
English-speaking countries use the same words or spellings,
please refer to the following chart for some common word
variations that may be encountered throughout this manual.
USA
Variation
asphalt
tarmac
authorized
authorised
backward(s)
rearward(s)
caster
castor
center
centre
color
colour
cord
lead
counterclockwise
anticlockwise
curb
kerb
elevator
lift
labor
labour
meter
metre
path
bridleway; footpath
pocketbook
handbag
provider
dealer; agent
sidewalk
pavement
tire
tyre
trunk
boot
turn signal
turn indicator
wrench
spanner
yard
grounds
4
Q6 EDGE 2.0/2.0x/3
SEAT ASSEMBLY
Seatback
Electronics Box
Armrest
Joystick
Controller
Rear Shroud
Seat Base
Seat Mount
Interface
Front Shroud
Manual
Freewheel
Lever
Drive Wheel
Spring Shock/
Gas Damper Location
Caster Wheel
POWER BASE ASSEMBLY
Front Rigging
(Foot Platform Shown)
INTRODUCTION
Safety
WELCOME to Quantum Rehab. The power chair you have
purchased combines state-of-the-art components with
safety, comfort, and styling in mind. We are confident that
these design features will provide you with the conveniences
you expect during your daily activities. Once you understand
how to safely operate and care for your power chair, it should
give you years of trouble-free operation and service.
Read and follow all instructions, warnings, and notes in this
manual before attempting to operate your power chair for the
first time. You must also read all instructions, warnings, and
notes contained in any supplemental instructional booklets
for the controller, front riggings, and/or seating system that
accompanied your power chair before initial operation. Your
safety depends upon you, as well as your provider, caretaker,
or healthcare professional in using good judgment.
If there is any information in this manual which you do not
understand, or if you require additional assistance for setup
or operation, please contact your Quantum Rehab Provider.
Failure to follow the instructions in this manual and
those located on your power chair can lead to personal
injury and/or damage to the power chair, including
voiding the warranty.
Purchaser’s Agreement
By accepting delivery of this product, you promise that you
will not change, alter, or modify this product or remove or
render inoperable or unsafe any guards, shields, or other
safety features of this product; fail, refuse, or neglect to
install any retrofit kits from time to time provided by Quantum
to enhance or preserve the safe use of this product.
Shipping and Delivery
Before using your power chair, make sure your delivery
is complete as some components may be individually
packaged. If you do not receive a complete delivery,
please contact your Quantum Rehab Provider immediately.
Where damage has occurred during transport, either to the
packaging or content, please contact the delivery company
responsible or your Quantum Rehab Provider.
NOTE: If you ever lose or misplace your copy of this
manual, contact us and we will be glad to send you a
new one immediately.
5
6
SAFETY
Product Safety Symbols
The symbols below are used on the power chair to identify
warnings, mandatory actions, and prohibited actions. It is very
important for you to read and understand them completely.
NOTE: There are more warnings identified and explained
in the Consumer Safety Guide that is included with
your power chair. Please become familiar with all the
warnings and safety information found in the Consumer
Safety Guide and refer to this resource often.
Read and follow the information in the owner's
manual.
Locked and in drive mode.
Place unit on level ground and stand to one side
when changing from drive mode to freewheel mode
or freewheel mode to drive mode.
Unlocked and in freewheel mode.
Indicates power chair securement points.
Indicates that power chair, with similarly labeled
seating system, conforms to ANSI/RESNA WC/Vo.
4, Section 19 for transport of an occupied power
chair in a motor vehicle.
Indicates power chair with similar label is
not rated for occupied transit.
Class II Equipment
Manufactured in
Power chair information label
Wire access point. For service use only.
General Guidelines
MANDATORY!
Do not operate your new power chair for the first time
without completely reading and understanding this
owner’s manual.
Your power chair is a state-of-the-art life-enhancement
device designed to increase mobility. We provide an extensive
variety of products to best fit the individual needs of the
power chair user. Please be aware that the final selection
and purchasing decision regarding the type of power chair to
be used is the responsibility of the power chair user, who is
capable of making such a decision, and his/her healthcare
professional (i.e., medical doctor, physical therapist, etc.).
The contents of this manual are based on the expectation
Your power chair is a state-of-the-art life-enhancement
device designed to increase mobility. We provide an extensive
variety of products to best fit the individual needs of the
power chair user. Please be aware that the final selection
and purchasing decision regarding the type of power chair
that a mobility device expert has properly fitted the power
chair to the user and has assisted the prescribing healthcare
professional and/or the Quantum Rehab Provider in the
instruction process for the use of the product.
There are certain situations, including some medical
conditions, where the power chair user will need to practice
operating the power chair in the presence of a trained
attendant. A trained attendant can be defined as a family
member or care professional specially trained in assisting a
power chair user in various daily living activities.
As you begin using your power chair during daily activities,
you will probably encounter situations in which you will need
some practice. Simply take your time and you will soon
be in full and confident control as you maneuver through
doorways, on and off of elevators, up and down ramps, and
over moderate terrain.
Below are some precautions, tips, and other safety
considerations that will help you become accustomed to
operating your power chair safely.
Pre-Ride Safety Check
Get to know the feel of your power chair and its capabilities. We
recommend that you perform a safety check before each use
to make sure your power chair operates smoothly and safely.
Perform the following inspections prior to using your
power chair:
„„ Check for proper tire inflation. Maintain but do not exceed
the psi/bar/kPa air pressure rating indicated on each tire
if equipped with pneumatic tires.
„„ Check all electrical connections. Make sure they are
tight and not corroded.
„„ Check all controller connections to the power base.
Make sure they are secured properly.
„„ Check the brakes. See “Care and Maintenance.”
„„ Check battery charge. See “Batteries and Charging.”
„„ Ensure the manual freewheel levers are in drive mode
before sitting on the power chair.
NOTE: If you discover a problem, contact your Quantum
Rehab Provider for assistance.
YOUR POWER CHAIR
The Q6 Edge 2.0/2.0x/3 Power Chair
Your power chair has two main assemblies: the seat assembly
and the power base assembly. Typically, the seat assembly
includes the armrests, seatback, and seat base. The power
base assembly includes two motor/brake assemblies, two
drive wheels, four caster wheels, two batteries, and wiring
harnesses. See Q6 Edge 2.0/2.0x/3 (page 4) and figure 1.
Controller Power Module
Controller Connector
To Battery Connectors
To Motor Connector
Main Circuit Breaker
PROHIBITED!
The spring tension on your power chair was factory set to
meet the needs of the demographic majority of users. Do
not adjust the tension of any spring on your power chair.
Electrical Components
The electrical components consist of the controller assembly,
the batteries, and the motors. The batteries, motors, and
controller power module (if equipped) are located on the
power base assembly. The controller is located on the seat
assembly. Connectivity between the controller and the
motors, batteries, and the battery charger is provided by one
or more wiring harnesses. See figure 1.
Quick
Release
Battery
Connectors
Fender Light
Connector
(Optional)
Controller Harness Connector: The controller harness
connector is where the controller plugs into the power base.
Each controller uses a different type of harness. Regardless of
which type of controller is used, the harness must be secured
to the seat assembly and not allowed to drag on the floor.
Motor Connectors: This is where the controller connects to
the motors.
Battery Connector: This is where the controller connects to
the batteries.
Suspension
Spring
Figure 1. Electrical Components
FREEWHEEL MODE
Controller Power Module: This enables the controller to
communicate with the batteries and the motors.
Main Circuit Breaker (located on the rear main frame): The
main circuit breaker is a safety feature built into your power chair.
When the batteries and the motors are heavily strained (e.g.,
from excessive loads), the main circuit breaker trips to prevent
damage to the motors and the electronics. If the circuit trips,
allow your power chair to “rest” for approximately one minute.
The circuit breaker will reset itself. Turn on the controller, and
continue normal operation. If the main circuit breaker continues
to trip repeatedly, contact your Quantum Rehab Provider.
Manual Freewheel Levers
For your convenience, your power chair is equipped with a
manual freewheel lever mounted on each motor. The levers
allow you to disengage the drive motors and maneuver the
chair manually.
DRIVE MODE
Figure 2. Manual Freewheel Lever Operation
7
8
YOUR POWER CHAIR
WARNING!
Do not use the power chair while the drive motors are
disengaged! Do not disengage the drive motors when
the power chair is on an incline, as the unit could roll
on its own! Only engage the freewheel mode when on a
level surface.
WARNING!
It is important to remember that when your power chair
is in freewheel mode, the braking system is disengaged.
To operate the manual freewheel levers:
1. Push down both manual freewheel levers for freewheel
mode (drive motor disengaged). See figure 2.
2. Pull up both manual freewheel levers for drive mode
(drive motor engaged). See figure 2.
MANDATORY!
Single Switch
iLevel Boot
(1 of 2 shown)
You must turn off the power before disengaging the
drive motors; otherwise, you may get an error code on
the controller. To clear this code, turn off the controller
and place the power chair in drive mode. Then, turn on
the controller. The error message should be cleared. If it
is not, contact your Quantum Rehab Provider.
NOTE: The power chair will be significantly easier to
push with the power off.
WARNING!
Single Switch
Avoid applying excessive force to the manual freewheel
levers.
Do not use your foot to operate the manual freewheel
levers. Do not stand on the manual freewheel levers.
Applying excessive force to the manual freewheel levers
may result in damage to the freewheel levers, motors,
and brakes.
iLevel Boot
(1 of 2 shown)
Do not use the freewheel lever handles as tie-down
points to secure this product.
iLevel® Feature (Optional)
Your power chair may be equipped with the iLevel feature
that will be used in conjunction with your seating system.
The iLevel feature is mounted on a Quantum power base for
maximum stability when the seating system is elevated. See
figure 3.
NOTE: If your power chair is equipped with a TRUBalance® 3 Power Positioning System, refer to the
information provided in the operation manual included
in your owner’s package.
Figure 3. iLevel Feature
YOUR POWER CHAIR
MANDATORY!
Before operating the iLevel feature, read the following.
These guidelines are provided for your benefit and will
aid you in the safe operation of the iLevel feature.
„„ Turn off the power before you are seated in your
power chair.
„„ Always have assistance when you are being seated
in or transferring to your power chair.
„„ Follow all of the procedures and heed the warnings
as explained in this owner’s manual, supplemental
manuals, and the Consumer Safety Guide.
WARNING!
The center of gravity of your power chair was factory set
to a position that meets the needs of the demographic
majority of users. Your Quantum Rehab Provider has
evaluated your power chair and made any necessary
adjustments to suit your specific requirements. Do not
change your seating configuration without first contacting
Quantum Rehab or your Quantum Rehab Provider.
Some power chair components are heavy. You may
need assistance to lift or carry them. Please refer to
the specifications table for specific component weights
before you disassemble the power chair.
Remove the occupant from the power chair before
making any adjustments.
9
WARNING!
The iLevel feature should be used only on flat, level,
indoor surface, such as in malls, offices, and/or medical
facilities. Never raise the seat from its lowest position
on an inclined surface. Failure to heed this warning can
result in the power chair tipping over.
The iLevel feature is intended for limited outdoor use on
only flat, level, hardscape surfaces. If you are unsure of
your environment, do not use iLevel outdoors.
Never raise the seat into iLevel when operating your power
chair on bumpy or uneven surfaces. Failure to heed this
warning can result in the power chair tipping over.
Always fasten the positioning belt when operating the
power chair.
Do not operate the iLevel or change the seat height in
any way while your power chair is positioned under a
fixed object, such as a table or desk. Keep area clear
prior to and during movement.
PROHIBITED!
Never use the iLevel outdoors on uneven terrain (gravel,
hills or other uneven, non-compact terrain) or in fields.
NOTE: The iLevel feature is automatically engaged when
the power elevating seat is activated and the iLevel
indicator is displayed on your controller.
NOTE: The iLevel feature is equipped with a system that
allows the power chair to drive at a predetermined, safe
speed when the seat is elevated. Always check to be
sure this system is operating properly before using your
power chair.
The iLevel feature is accessed through the controller or a
single switch, and the power chair must be on a flat, level
surface to activate iLevel. Once the seating system actuator
is started, the iLevel boots (see figure 3) inhibit movement
of the front caster arms. The seating system can be reclined
or tilted up to 20° while the iLevel feature is activated.
NOTE: If a warning or visual indicator appears on your
controller stating that iLevel is not engaged, the power
chair's speed will be reduced to 25% when elevated.
If this warning appears while on level ground, please
discontinute use of iLevel feature and consult your
Quantum Rehab Provider for assistance.
NOTE: For more information on the iLevel warning
displays, refer to the basic operation instructions for
your controller.
Fender Lights (Optional)
Your power chair may be equipped with fender lights. The
lights are composed of three white LEDs in the front and
three red LEDs in the rear and are mounted on the fenders
of your power base. See figure 4.
The iLevel feature should be used only on flat, level, indoor
surfaces, such as in malls, offices, and/or medical facilities,
and only on limited, flat, level, hardscape, outdoor surfaces.
While the iLevel feature is in use, the power chair can drive at
a predetermined, safe speed. Refer to the specifications table
for more information on reduction of the maximum speed.
NOTE: Prior to initial use, ensure that the fender light
switch is connected.
10
YOUR POWER CHAIR
NOTE: If your power chair is equipped with an attendant
control, the fender lights will activate using the single
switch when the controller is turned on.
The fender lights operate through a single switch.
To operate the fender lights using the single switch:
1. Press the single switch once to activate the fender lights.
2. Press the single switch again to deactivate the fender
lights.
NOTE: Placing the single switch on the outside of the
power chair, for example, on the side rail, may increase
the overall width of the power chair.
WARNING!
The single switch should be mounted in a location
that is convenient for the power chair user and where
the switch harness will not be caught in drive tires or
running gear, pinched in the seat frame, or damaged
when passing through doorways.
Single Switch
Fender Light
Figure 4. Single Switch to Operate Fender Lights
ASSEMBLY
11
Initial Assembly
Your power chair may require some assembly either
before initial use or after transportation. It may also require
disassembly to make some comfort adjustments. Figure 5
details those parts of the power chair that are designed
to be disassembled and assembled by an end user or by
a qualified caregiver before using the product or making
comfort adjustments.
NOTE: Any nylon insert lock nut removed during the
disassembly or adjustment of the power chair must be
replaced with a new nut. Nylon insert lock nuts should
not be reused as it may cause damage to the nylon
insert, resulting in a less secure fit. Replacement nylon
insert lock nuts are available at local hardware stores or
through your Quantum Rehab Provider.
Controller
Position
Armrest
Angle
Adjustment
Seat Installation
It may be necessary to install the seat either prior to initial
operation or after transporting your power chair. Contour
seats are attached to the power base with the Universal
Mounting System (UMS). The UMS consists of universal
parts that may be attached to the seat, regardless of seat
width or seat depth. The two main components are aluminum
extrusions mounted to the seat base. These extrusions attach
to a pair of trapeze bars that are mounted to the power base.
See figure 6.
NOTE: If your power chair is equipped with a Synergy
Seat or a TRU-Balance® 3 Power Positioning System,
refer to the information provided in separate manuals.
Foot Platform
Angle
Adjustment
Foot Platform
Height/Depth
Adjustment
Figure 5. Assembly View
WARNING!
Do not pick up the seat frame by the armrests. They are
free to pivot, and you may lose control of the seat if they
do so.
To install the seat:
1. Tilt the seat back and slide the rear extrusion onto the
rear trapeze bar. See figure 6.
2. Lower the front extrusion onto the front trapeze bar until
the seat latches into place.
3. Flip the seat latch safety down.
WARNING!
Front Extrusion
Seat Latch
Safety
Rear Extrusion
Trapeze
Bars
Make sure the seat latch safety is flipped down before
using your power chair.
4. Install the controller and route the harness to the back of
the power base. See figure 7, 8, 9, or 10.
MANDATORY!
Prevent controller harness damage! Avoid routing the
controller harness on the outside of the armrest pad.
Route the harness under the armrest or toward the
inside of the armrest pad. Use correct tie-down points for
controller harness to prevent the harness from getting
caught in the drive tires, pinched in the seat frame, or
damaged when passing through doorways.
Figure 6. Universal Mounting System and Contour Seat
12
ASSEMBLY
5. Plug the controller connector into the rear of the power
base. See figure 1.
6. Secure the controller harness to the armrest receiver
with wire ties. See figure 7, 8, 9, or 10.
Power Elevating Seat Option
Your power chair may be equipped with a power elevating
seat option. While the seat itself may be any one of the styles
offered for this model, the way the seat base attaches to the
power base is different.
To install the power elevating seat:
1. Place the seat plate interface bracket onto the actuator.
See figure 11.
2. Insert the supplied hardware into the actuator and
tighten the hardware.
3. Place the seating system onto the seat plate and secure.
4. Plug in the power seat toggle switch harness, if equipped.
Figure 7. Controller Harness Routing on a TRU-Balance 3
Transit Securement System
If your power chair is equipped with a transit securement
system, it is equipped with manufacturer installed front
and rear securement brackets and may be equipped with
positioning belt anchoring brackets. See figure 12. Refer to
the supplement provided with your power chair for information
on how to use the transit securement system.
Wire Ties
Power Chair Securement Points
The power chair is equipped with four (4) tie-down points for
the purpose of securing the unoccupied power chair during
motor vehicle transport. Each tie-down is clearly labeled for
this purpose.
To secure a power chair equipped with tie-down points:
„„ Always secure the power chair in a forward-facing
position in the vehicle.
„„ Attach the four (4) tie-down straps to only designated,
labeled transit securement points indicated by anchor
symbols on the power chair. See figures 12 and 13.
Tighten the straps sufficiently to remove all slack.
„„ Never attach tie-downs to adjustable, moving, or
removable parts of the power chair such as armrests,
front riggings, and wheels.
„„ Position the anchor point for the rear tie-down straps
directly behind the rear securement points on the power
chair. The front tie-down straps should be anchored to
floor points that are spaced wider than the power chair
to provide increased stability. See figure 13.
Wire Ties
To Power Base
Figure 8. Controller Harness Routing on a Contour Seat
MANDATORY!
The power chair should be used as indicated in the
manufacturer's instructions. If you have any questions
about the proper use of your power chair, contact your
Quantum Rehab Provider.
Figure 9. Controller Harness Routing on a TB-Flex Seat
ASSEMBLY
13
7
1
8
2
9
3
10
Securement Brackets
(2 of 4 Shown)
Figure 12. Transit System Securement Brackets
4
5
6
1
2
3
4
5
6
7
8
9
10
Figure 10. Controller Harness Routing on a Captain's
Seat with iLevel
FRONT OF VEHICLE
Seat Plate
Interface
Bracket
Actuator
Figure 11. Power Elevating Seat Actuator
Figure 13. Unoccupied Transit System Securement Points
14
COMFORT ADJUSTMENTS
Comfort Adjustments
After becoming familiar with your power chair’s operation,
you may find the need to make some adjustments to increase
your comfort, such as seat height and angle, armrest width,
angle and height, and controller position.
Trapeze Bars
Seat Interface
Weldment
Hardware
NOTE: If your power chair is equipped with a Synergy
Seat or TRU-Balance® 3 Power Positioning System, refer
to the seat adjustment information contained in separate
manuals. If your power chair is equipped with a contoured
seating system, refer to the following information.
WARNING!
The center of gravity of your power chair was factory set
to a position that meets the needs of the demographic
majority of users. Your Quantum Rehab Provider has
evaluated your power chair and made any necessary
adjustments to suit your specific requirements. Do not
change your seating configuration without first contacting
Quantum Rehab or your Quantum Rehab Provider.
Some power chair components are heavy. You may
need assistance to lift or carry them. Please refer to
the specifications table for specific component weights
before you disassemble the power chair.
Hardware
Figure 14. Seat Height/Angle Adjustment
Remove the occupant from the power chair before
making any adjustments.
You may need the following to make comfort adjustments:
„„ metric/standard socket set and ratchet
„„ adjustable wrench
„„ metric/standard hex key set
„„ thread lock
Seat Height and Seat Angle Adjustment
If your power chair is not equipped with a transit securement
system, you can change the seat height to one of three
positions by raising the front and rear trapeze bars. If you
raise or lower only one trapeze bar (front or rear), you can
also change the seat base angle (dump).
MANDATORY!
If your power chair is equipped with a transit securement
system and any adjustment to the seat height or seat
angle is necessary, contact your Quantum Rehab
Provider. These comfort adjustment can only be made
by a Quantum Rehab Provider.
To change the seat height:
1. Turn off the power to the controller.
2. Make sure the power chair is in drive mode.
3. Unplug the controller connector(s) from the power base.
See figure 1.
4. Flip up the seat latch safety. See figure 6.
5. Squeeze the seat latch and release the seat from the
front trapeze bar.
6. Slide the seat forward and remove it from the power base.
Seat Mounting Holes
Figure 15. Seat Position Adjustment
7. Remove the hardware that attaches the trapeze bars to
the seat interface weldments. See figure 14.
8. Move the trapeze bars up or down to the desired height.
NOTE: Change the seat dump by raising or lowering
only one trapeze bar (front or rear).
9. Reinstall the hardware.
10. Reinstall the seat.
11. Reconnect the controller to the power base.
COMFORT ADJUSTMENTS
15
Seat Position
You can move the seat forward or rearward by changing the
extrusion mounting position.
To change the position:
1. Turn off the power to the controller.
2. Make sure the power chair is in drive mode.
3. Unplug the controller connector(s) from the power base.
4. Remove the seat from the power base.
5. Remove both extrusions from the bottom of the seat.
6. Reposition the extrusions on a different set of mounting
holes. You must move both extrusions the same number
of holes either forward or backwards. See figure 15.
7. Fasten the extrusions back onto the bottom of the seat.
8. Reinstall the seat.
9. Reconnect the controller to the power base.
Manual Recline Seatback Adjustment
If your power chair is equipped with a reclining seat, you can
adjust the seatback angle with the seatback release lever.
The lever is located on the right side of the seat base.
To adjust the recline angle:
1. Pull up on the seatback release lever.
2. Lean forward or backward to the desired position.
3. Release the lever.
Armrest Width Adjustment
You can change each armrest’s width independently of
the other.
NOTE: Changing the armrest width may increase the
overall width of your power chair.
To change the armrest width:
1. Locate the two armrest knobs on each side of the
armrest receiver bracket. See figure 16.
2. Loosen the knobs.
3. Slide the armrests in or out to the desired width.
4. Tighten the knobs.
Armrest Angle Adjustment
To change the armrest angle:
1. Lift the armrest straight up so that it is perpendicular to
the floor. See figure 16.
2. Loosen the jam nut.
3. Turn the adjusting screw to raise or lower the front of the
armrest.
4. Tighten the jam nut to lock the adjusting screw into place.
Armrest Height Adjustment
To change the armrest height:
1. Loosen the two setscrews located on the armrest
receiver. See figure 16.
2. Raise or lower the armrest to the desired height.
3. Tighten the setscrews to secure the armrest.
Jam Nut
Armrest Angle
Adjusting Screws
Controller
Bracket
Setscrew
Armrest Height
Adjusting Screws
Armrest Knob
Figure 16. Seatback/Armrest Adjustment
Controller Position
You can move the controller in toward or out away from the
armrest, or change the position of the controller for either
left-hand or right-hand use.
WARNING!
Do not place the controller harness so that it can be
pinched in the seat frame or the power base frame.
To extend the controller:
1. Flip up the armrest so it is perpendicular to the floor.
2. Loosen the setscrew on the controller bracket. See
figure 16.
3. Slide the controller into or out of the armrest to the
desired position.
4. Tighten the setscrew to secure the controller.
To change the controller position:
1. Turn off the power to the controller.
2. Unplug the controller connector(s) from the power base.
3. Remove any wire ties securing the controller harness to
the armrest.
4. Flip up the armrest so it is perpendicular to the floor.
5. Loosen the setscrew on the controller bracket.
6. Slide the controller out of the armrest.
7. Loosen the setscrew in the other armrest.
8. Place the controller in the other armrest.
9. Tighten the setscrews in both armrests.
10. Route the controller harness to the back of the power
base and plug in the controller.
11. Secure the controller harness to the armrest with wire
ties. See figure 8.
NOTE: If your power chair is equipped with a Synergy
Seat or TRU-Balance® 3 Power Positioning System, refer
to the information provided in supplemental manuals
provided with your seating system.
16
COMFORT ADJUSTMENTS
Foot Platform Height Adjustment
The foot platform height is easily adjusted to several different
heights.
To raise or lower the foot platform:
1. Remove the hardware from the foot platform bracket.
See figure 17.
2. Raise or lower the foot platform to the desired height.
3. Reinstall the hardware into the foot platform bracket and
tighten.
Foot Platform Depth Adjustment
You can adjust the depth of the foot platform.
To adjust the foot platform depth:
1. Remove the hardware from the foot platform bracket.
See figure 17.
2. Move the foot platform in or out to the desired depth.
3. Reinstall the hardware into the foot platform bracket and
tighten.
Foot Platform Angle Adjustment
You can adjust the angle of the foot platform.
Foot Platform
Bracket
Hardware
Screw
Figure 17. Foot Platform Adjustment
To adjust the foot platform angle:
1. Flip up the foot platform and locate the screw. See
figure 17.
2. Turn the screw to raise or lower the front of the foot
platform.
Power Elevating Seat (Optional)
If your power chair is equipped with a power elevating seat,
you can change the seat height either through the controller,
through a toggle, or through an optional single switch
mounted to one of the armrests.
To change the seat height through toggle switch:
1. Press forward on the toggle switch to raise the seat. See
figure 18.
2. Pull back on the toggle switch to lower the seat.
WARNING!
Do not allow the motor to run more than a few seconds
after the mechanism reaches the top or bottom limit.
To change the seat height through the single switch:
1. Press and hold the single switch button to raise the seat.
Release the button to stop.
2. Press and hold the single switch button to lower the seat.
Release to stop.
If a latch function is on:
1. Press the single switch button to raise the seat. Press
the single switch button again to stop.
2. Press the single switch button to lower the seat. Press
the single switch button again to stop.
Figure 18. Power Elevating Seat Toogle Switch
COMFORT ADJUSTMENTS
17
NOTE: For more information on operating the power
elevating seat through the controller, contact your
Quantum Rehab Provider.
WARNING!
The power elevating seat option is intended for use on
a level surface only. Never raise the seat from its lowest
position on an inclined surface. Failure to heed this
warning can result in the power chair tipping over.
Never raise the seat from its lowest position when
operating your power chair on bumpy or uneven
surfaces. Failure to heed this warning can result in the
power chair tipping over.
Never raise the power elevating seat while your power
chair is in the freewheel mode.
Always fasten the positioning belt when operating the
power elevating seat.
NOTE: The power elevating seat option is equipped with
a system that reduces the speed of the power chair to
one quarter when the seat is elevated. Always check to
be sure this system is operating properly before using
your power chair.
Positioning Belt
Your power chair may be equipped with a positioning belt
that can be adjusted for operator comfort. See figure 19.
The positioning belt is designed to support the operator
so that he/she does not slide down or forward in the seat.
The positioning belt is not designed for use as a restraining
device.
WARNING!
The positioning belt is not designed for use as a seat
belt in a motor vehicle. Nor is your power chair suitable
for use as a seat in any vehicle. Anyone traveling in a
vehicle should be properly belted into seats approved
by the vehicle manufacturer.
The positioning belt should be secured at all times.
Never allow the positioning belt to hang or drag on the
floor as it may become entangled.
To install the positioning belt:
1. Remove the rearmost screw that holds the seat hinge to
the seat base on both the left and right seat hinges.
2. Insert the screw through the supplied washer, through
the positioning belt and into the seat base for each side
of the power chair seat.
3. Tighten both screws.
Figure 19. Positioning Belt Adjustment
To adjust the positioning belt for operator comfort:
1. Once seated, insert the metal tab on one side of the belt
into the plastic housing on the opposite side until you
hear a click. See figure 19.
2. Pull the excess strap attached to the metal tab until it is
secure, but not so tight as to cause discomfort.
To release the positioning belt:
1. Press the push button mechanism on the plastic housing.
MANDATORY!
Make sure the positioning belt is properly secured to the
power chair and is adjusted for operator comfort before
each use.
Inspect the positioning belt for loose parts or damage,
including tears, worn spots, bent hardware, damaged
latch mechanisms, dirt or debris, before each use of
the power chair. If you discover a problem, contact your
Quantum Rehab Provider for maintenance and repair.
18
BATTERIES AND CHARGING
Batteries and Charging
Your power chair uses two long-lasting, 12-volt, deep-cycle
batteries. These batteries are sealed and maintenance
free. Since they are sealed, there is no need to check the
electrolyte (fluid) level. Deep-cycle batteries are designed
to handle a longer and deeper discharge. Though they are
similar in appearance to automotive batteries, they are not
interchangeable. Automotive batteries are not designed to
handle a long, deep discharge, and also are unsafe for use
in power chairs.
MANDATORY!
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
WARNING!
Contact your Quantum Rehab Provider if you have any
questions regarding the batteries in your power chair.
PROHIBITED!
Always use two batteries of the exact same type,
chemistry, and amp-hour (Ah) capacity. Refer to
specifications table in this manual and in the manual
supplied with the battery charger for recommended type
and capacities.
Charging the Batteries
The battery charger is essential in providing long life for your
power chair batteries. It is designed to optimize your power
chair’s performance by charging the batteries safely, quickly,
and easily.
PROHIBITED! Removal of grounding prong can
create electrical hazard. If necessary, properly
install an approved 3-pronged adapter to an
electrical outlet having 2-pronged plug access.
PROHIBITED! Never use an extension cord to
plug in your battery charger. Plug the charger
directly into a properly wired standard electrical
outlet.
PROHIBITED! Do not allow unsupervised
children to play near the power chair while
the batteries are charging. Quantum Rehab
recommends that you do not charge the
batteries while the power chair is occupied.
MANDATORY! Read the battery charging
instructions in this manual and in the manual
supplied with the battery charger before
charging the batteries.
WARNING! Explosive gases may be generated
while charging the batteries. Keep the power
chair and battery charger away from sources
of ignition such as flames or sparks and provide
adequate ventilation when charging the batteries.
WARNING! You must recharge the power chair
batteries with the supplied off-board battery
charger. Do not use an automotive-type battery
charger.
WARNING! Inspect the battery charger, wiring,
and connectors for damage before each use.
Contact your Quantum Rehab Provider if damage
is found.
WARNING! Do not attempt to open the battery
charger case. If the battery charger does not
appear to be working correctly, contact your
Quantum Rehab Provider.
WARNING! Be aware that the battery charger
case may become hot during charging. Avoid
skin contact and do not place on surfaces that
may be affected by heat.
WARNING! If the battery charger is equipped
with cooling slots, then do not attempt to insert
objects through these slots.
WARNING! If the battery charger has not been
tested and approved for outdoor use, then do
not expose it to adverse or extreme weather
conditions. If the battery charger is exposed
to adverse or extreme weather conditions, then
it must be allowed to adjust to the difference
in environmenal conditions before use indoors.
Refer to the manual supplied with the battery
charger for more information.
BATTERIES AND CHARGING
19
To charge the batteries using the off-board charger:
1. Position your power chair next to a standard electrical
outlet.
2. Be certain the controller power is turned off and the
power chair is in drive mode.
3. Plug the off-board charger into the off-board charger/
programming socket on the controller. See figure 20.
4. Plug the off-board charger into the electrical outlet.
WARNING!
The LED lights on the charger indicate different charger
conditions at various times: charger power on, charging
in progress, and charging complete. If the LED does
not indicate that charging is complete within 24 hours,
unplug the charger from the outlet and contact your
Quantum Rehab Provider. Refer to the manual supplied
with the charger for a complete explanation of these
indicators.
5. When the batteries are fully charged, unplug the offboard charger from the electrical outlet and then from
the controller.
Battery Break-in
To break in new batteries for maximum efficiency:
1. Fully recharge any new battery prior to its initial use.
This brings the battery up to about 90% of its peak
performance level.
2. Operate your power chair throughout the house and
yard. Move slowly at first, and do not travel too far until
you become accustomed to the controls and break in
the batteries.
3. Give the batteries another full charge of at least 8 to 14
hours and operate your power chair again. The batteries
will now perform at over 90% of their potential.
4. After four or five charging cycles, the batteries will top off at
100% charge and last for an extended period.
Frequently Asked Questions (FAQs)
How does the charger work?
The battery charger takes the standard electrical outlet
voltage (alternating current) and converts it to 24V DC (direct
current). The power chair batteries use direct current to
run your power chair. When the battery voltage is low, the
charger works harder to charge the battery. As the battery
voltage approaches full charge, the charger does not work
as hard to complete the charging cycle. When the battery
is fully charged, the amperage from the charger is nearly at
zero. This is how the charger maintains a charge but does not
overcharge the battery.
Can I use a different battery charger?
You should use the charger supplied with the power chair. It
is the safest, most efficient tool to charge the batteries. We
do not recommend using other types of chargers (e.g., an
automotive battery charger).
Figure 20. Battery Charger
NOTE: Your power chair’s charger will not operate
after the batteries have been discharged to nearly zero
voltage. If this happens, call your Quantum Rehab
Provider for assistance.
How often must I charge the batteries?
Many factors come into play when deciding how often to
charge the batteries. You may use your power chair all day
on a daily basis or you may not use it for weeks at a time.
„„ Daily Use
If you use your power chair on a daily basis, charge the
batteries as soon as you are finished using your power
chair. Your power chair will be ready each morning to
give you a full day’s service. It is recommended that you
charge the batteries at least 8 to 14 hours after daily
use. We recommend that you charge the batteries for an
additional 4 hours after the battery charger indicates that
charging is complete.
„„ Infrequent Use
If you use your power chair infrequently (once a week or
less), you should charge the batteries at least once per
week for at least 24 hours.
NOTE: Keep your batteries fully charged and avoid
deeply discharging your batteries. Refer to the
manual supplied with the battery charger for charging
instructions. We recommend charging your batteries for
at least 48 continuous hours once per month to improve
battery performance and battery life.
How can I get maximum range or distance per charge?
Rarely do you have an ideal driving situation such as smooth,
flat, hard terrain with no wind, hills, or curves. More often you
are presented with hills, sidewalk cracks, uneven and loosely
packed surfaces, curves, and wind. All of these factors will
affect the distance or running time per battery charge. Below
are a few suggestions for obtaining the maximum range per
charge:
20
BATTERIES AND CHARGING
„„
„„
„„
„„
Always charge the batteries fully prior to your trip.
Plan your trip in advance to avoid inclines if possible.
Limit baggage weight to essential items.
Try to maintain an even speed and avoid stop-and-go
driving.
„„ We recommend charging your batteries for at least 48
continuous hours once per month to improve battery
performance and battery life.
What type of batteries should I use?
We recommend deep-cycle batteries that are sealed
and maintenance free. Both AGM and Gel-Cell are deepcycle batteries that are similar in performance. Refer to
the specifications table for more information regarding the
batteries used with your power chair.
WARNING!
Corrosive chemicals contained in batteries. Use only
AGM or Gel-Cell batteries to reduce the risk of leakage
or explosive conditions.
Why do my new batteries seem weak?
Deep-cycle batteries employ a much different chemical
technology than that used in car batteries, nickel-cadmium
(nicads), or in other common battery types. Deep-cycle
batteries are specifically designed to provide power, drain
down their charge, and then accept a relatively quick
recharge. AGM and Gel-Cell batteries should be charged as
often as possible. They do not have a “memory” like nickelcadmium batteries.
We work closely with our battery manufacturer to provide a
battery that best suits your power chair’s specific demands.
Fresh batteries arrive regularly at Quantum and are promptly
shipped with a full charge. During shipping, the batteries
encounter temperature extremes that may influence initial
performance. Heat robs the charge from the battery, and
cold slows the power available and extends the time needed
to recharge the battery (just as with a car battery).
It might take a few days for the temperature of the battery
to stabilize and adjust to its new ambient temperature. More
importantly, it will take a few “charging cycles” (a partial
drain—then a full recharge) to establish the critical chemical
balance that is essential to the battery’s peak performance
and long life. It will be well worth it to take the time to break
in your battery properly.
How can I ensure maximum battery life?
A fully charged deep-cycle battery will provide reliable
performance and extended battery life. Keep your power
chair’s batteries fully charged whenever possible. Batteries
that are regularly and deeply discharged, infrequently
charged, or stored without a full charge may be permanently
damaged, causing unreliable power chair operation and
limited battery life.
NOTE: The useful life of a battery is quite often a reflection
of the care it receives.
How should I store my power chair and its batteries?
If you do not use your power chair regularly, we recommend
maintaining battery vitality by charging the batteries at least
once per week.
If you do not plan on using your power chair for an extended
period, fully charge the batteries prior to storage. Disconnect
the battery harnesses and store the power chair in a warm,
dry environment. Avoid temperature extremes, such as
freezing and excessively hot conditions, and never attempt
to charge a frozen battery. A cold or frozen battery should be
warmed for several days prior to recharging.
What about public transportation?
AGM and Gel-Cell batteries are designed for application in
power chairs and other mobility vehicles. These batteries are
Federal Aviation Administration (FAA) approved, allowing
safe transportation on aircraft, buses, and trains, as there is
no danger of spillage or leakage. We suggest you contact the
carrier’s ticket counter in advance to determine that carrier’s
specific requirements.
What about shipping?
If you wish to use a freight company to ship your power
chair to your final destination, repack your power chair in the
original shipping container and ship the batteries in separate
boxes.
CARE AND MAINTENANCE
Care and Maintenance
Your power chair is a sophisticated power chair. Like any
motorized vehicle, it requires routine maintenance checks.
You can perform some of these checks, but others require
assistance from your Quantum Rehab Provider. Preventive
maintenance is very important. If you follow the maintenance
checks in this section as scheduled, you can help ensure that
your power chair gives you years of trouble-free operation.
If you have any doubt as to your power chair’s care or
operation, contact your Quantum Rehab Provider.
WARNING!
Do not service the power chair when the seat is occupied.
Your power chair, like most electrical equipment, is
susceptible to damage from the elements. Avoid damp areas
of any kind.
WARNING!
Direct or prolonged exposure to water or dampness could
cause the power chair to malfunction electronically and
mechanically. Water can cause electrical components
to corrode and the chair’s frame to rust. Power chairs
should be examined periodically for signs of corrosion
caused by water exposure, bodily fluid exposure, or
incontinence. Damaged components should be replaced
or treated immediately.
Should your power chair come in contact with water:
1. Dry your power chair as thoroughly as possible with a
towel.
2. Allow your power chair to sit in a warm, dry place for 12
hours to allow unseen water to evaporate.
3. Check the joystick operation and the brakes before using
your power chair again.
4. If any inconsistencies are found, take your power
chair to a Quantum Rehab Provider. Power chairs that
are frequently exposed to sources of water, such as
incontinence, should be inspected often for corrosion
and electronic components may need to be replaced
frequently.
Temperature
„„ Some of the parts of your power chair are susceptible
to extreme changes in temperature. Always keep your
power chair between the temperatures of 18°F (-8°C)
and 122°F (50°C).
„„ In extremely cold temperatures the batteries may freeze.
The specific temperature at which they freeze depends
on a number of factors, such as battery charge, usage,
and composition of the batteries (e.g., AGM or Gel-Cell).
General Guidelines
„„ Avoid knocking or bumping the controller, especially the
joystick.
„„ Avoid prolonged exposure of your power chair to extreme
conditions, such as heat, cold, or moisture.
21
„„ Keep the controller clean.
„„ Check all connectors to ensure that they are all tight and
secured properly.
„„ Make sure pneumatic tires are inflated to the psi/bar/kPa
air pressure rating indicated on the tire.
WARNING!
Make sure your tires are inflated to the psi/bar/kPa air
pressure rating indicated on the tire for pneumatic
tires. Do not under inflate or over inflate your tires. Low
pressure may result in loss of control, and overinflated
tires may burst. Overinflating tires can cause them to
explode.
Do not use a high pressure hose to inflate your tires.
„„ Use a rubber conditioner on the tire sidewalls to help
preserve them.
WARNING!
Never use a rubber conditioner on the tread area of the
tires; doing so may make the tires slippery and cause
your power chair to skid.
„„ All wheel bearings are prelubricated and sealed. They
require no subsequent lubrication.
„„ If your power chair has a body shroud with a glossy
finish, the body shroud has been sprayed with a clear
sealant coating. You can apply a light coat of car wax to
help it retain its high-gloss appearance. If your power
chair has a body shroud with a matte finish, use ONLY
products developed for matte-finish paint. Do not use
wax, detail spray, ArmorAll®, or any product made for
glossy paint.
WARNING!
Carefully choose the correct product to protect the
finish of your power chair's shroud(s). ONLY products
developed for matte-finish paint should be used on
shrouds with a matte finish. Failure to follow this warning
may result in damage to the shroud's matte paint finish.
„„ Check all electrical connections. Make sure they are tight
and are not corroded. Batteries must sit flat within the
battery tray, with the battery terminals facing rearward.
Refer to the battery wiring label for the correct wiring
layout.
WARNING!
Even though the power chair has passed the necessary
testing requirements for ingress of liquids, you should
keep electrical connections away from sources of
dampness, including direct exposure to water or bodily
fluids and incontinence. Check electrical components
frequently for signs of corrosion and replace as
necessary.
22
CARE AND MAINTENANCE
Daily Checks
„„ With the controller turned off, check the joystick. Make
sure it is not bent or damaged and that it returns to the
neutral position when you release it. Check the rubber
boot around the base of the joystick for damage. Visually
inspect the boot. Do not handle or try to repair it. See
your Quantum Rehab Provider if there is a problem.
„„ Visually inspect the controller harness. Make sure that
it is not frayed, cut, or has any wires exposed. See your
Quantum Rehab Provider if there is a problem.
„„ Check for flat spots on solid tires. Flat spots could
adversely affect stability.
„„ Inspect the seating system, armrests, and front riggings
for loose hardware, stress points, or damage. See your
Quantum Rehab Provider if there is a problem.
Weekly Checks
„„ Disconnect and inspect the controller from the power
base. Look for corrosion. Contact your Quantum Rehab
Provider if necessary.
„„ Ensure that all parts of the controller system are securely
fastened to your power chair. Do not overtighten any
screws.
„„ Check for proper tire inflation. Pneumatic tires should be
inflated to the psi/bar/kPa air pressure rating indicated
on each tire. If a tire does not hold air, see your Quantum
Rehab Provider for replacement of the tube.
„„ Check the brakes. This test should be carried out on a
level surface with at least 3 feet (1 meter) of clearance
around your power chair.
To check the brakes:
1. Turn on the controller and turn down the speed level of
your power chair.
2. After one second, check the battery condition meter.
Make sure that it remains on.
3. Slowly push the joystick forward until you hear the
electric brakes click. Immediately release the joystick.
You must be able to hear each electrical brake operating
within a few seconds of joystick movement. Repeat this
test three times, pushing the joystick backward, then left,
and then right.
Monthly Checks
„„ Check for drive tire wear. See your Quantum Rehab
Provider for repair.
„„ Check the caster wheels for wear. Replace them as
necessary.
„„ Check the caster forks for damage or fluttering which
indicates that they may need to be adjusted or have the
bearings replaced. See your Quantum Rehab Provider
for repair.
„„ Check the entire power chair for loose hardware and
changes in the function or performance of the power
chair. See your Quantum Rehab Provider for service or
repair.
„„ Keep your power chair clean and free of foreign material,
such as mud, dirt, hair, food, drink, etc.
„„ Spring shocks and gas dampers should be visually
checked for any abnormality, structure damage, or bent
rods. See your Quantum Rehab Provider for repair.
Yearly Checks
Take your power chair to your Quantum Rehab Provider for
yearly maintenance, especially if you use your power chair
on a daily basis. This helps ensure that your power chair is
functioning properly and helps prevent future complications.
Storage
Your power chair should be stored in a dry place, free
from temperature extremes. When storing, disconnect the
batteries from the power chair. See “Batteries and Charging.”
WARNING!
If you fail to store the unit properly, the frame can rust
and the electronics can be damaged. Any corroded
electronic connection should be replaced.
Batteries that are regularly and deeply discharged,
infrequently charged, stored in extreme temperatures, or
stored without a full charge may be permanently damaged,
causing unreliable performance and limited service life. It
is recommended that you charge the batteries periodically
throughout periods of prolonged storage to ensure proper
performance.
You may wish to place several boards under the frame of
your power chair to raise it off of the ground during periods
of prolonged storage. This takes the weight off the tires and
reduces the possibility of flat spots developing on the areas
of the tires contacting the ground.
Disposal of Your Power Chair
Your power chair must be disposed of according to applicable
local and national statutory regulations. Contact your local
waste disposal agency or Quantum Rehab Provider for
information on proper disposal of power chair packaging,
metal frame components, plastic components, electronics,
batteries, neoprene, silicone, and polyurethane materials.
Cleaning and Disinfection
„„ Use a damp cloth and mild, non-abrasive cleanser to
clean the plastic and metal parts of your power chair.
Avoid using products that may scratch the surface of
your power chair.
„„ If necessary, clean your product with an approved
disinfectant. Make sure the disinfectant is safe for use
on your product before application.
CARE AND MAINTENANCE
23
WARNING!
Follow all safety instructions for the proper use of the
disinfectant and/or cleaning agent before applying it
to your product. Failure to comply may result in skin
irritation or premature deterioration of upholstery and/
or power chair finishes.
Never hose off your power chair or place it in direct
contact with water. Your power chair has a painted, ABS
plastic body shroud that allows it to be easily wiped
clean with a damp cloth.
Wheel Hub
Never use any chemicals to clean a vinyl seat, as they
may cause the seat to become slippery or dry out and
crack. Use soapy water and dry the seat thoroughly.
Wheel Replacement
If you have pneumatic tires and you have a flat tire, you can
replace the tube. If your chair is equipped with a solid tire
insert, then you must replace the entire wheel assembly.
Replacement tires, tubes, and wheel assemblies are readily
available through your Quantum Rehab Provider.
Lug Nuts
Figure 21. Drive Wheel
Tire
WARNING!
The wheels on your power chair should only be serviced
or replaced by a Quantum Rehab Provider or a qualified
technician.
Rear Rim
Half
Tube
Front Rim
Half
Screws
Be sure that the controller’s power is turned off and the
power chair is not in freewheel mode before performing
this procedure.
When changing a tire, remove only the five lug nuts,
then remove the wheel. If any further disassembly is
required, deflate the tire completely or it may explode.
Follow these easy steps for a quick and safe repair for
both pneumatic and solid tires:
1. Turn off the power to the controller.
2. Set the power chair up on blocks.
3. If you are changing a pneumatic tire, completely deflate
it before removing the wheel.
4. Remove the five (5) lug nuts from the wheel hub. See
figure 21.
5. Pull the wheel off of the hub.
6. Remove the screws and separate the front and rear rim.
See figure 22.
7. Remove the old tube from the pneumatic tire and replace
it with a new tube or replace the entire assembly if it is
a solid tire.
8. Screw together the two rim halves.
9. Slide the wheel back onto the hub.
10. Reinstall the five (5) lug nuts onto the wheel hub and
tighten.
11. Inflate the pneumatic tire to the psi/bar/kPa air pressure
rating indicated on each tire.
12. Remove the power chair from the blocks.
Figure 22. Drive Wheel Disassembled
24
CARE AND MAINTENANCE
Battery Set Configuration:
+ = Positive (Red) Terminal Post
- = Negative (Black) Terminal Post
Connect Red wire to Red Positive (+) Terminal Posts.
Connect Black wire to Black Negative (-) Terminal Posts.
Front Cover
Battery Wiring Diagram Label
Release Handles
Quick Release
Battery Connectors
Rear Battery
Front Battery
Figure 23. Battery Installation
CARE AND MAINTENANCE
Battery Replacement
A battery wiring diagram is printed on a decal located on
the front cover. See the specification table for correct battery
specifications.
MANDATORY!
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
WARNING!
The batteries in your power chair should only be
serviced or replaced by a Quantum Rehab Provider or a
qualified technician.
Do not replace batteries when seat is occupied.
Power chair batteries are heavy. See specifications
table. If you are unable to lift that much weight, be sure
to get help. Use proper lifting techniques and avoid
lifting beyond your capacity.
Do not mix old and new batteries. Always replace both
batteries at the same time.
PROHIBITED!
Keep tools and other metal objects away from the battery
terminals. Contact with tools can cause electrical shock.
To replace the batteries:
1. Turn off the power to the controller.
2. Make sure that the power chair is in drive mode. See
“Your Power Chair.”
3. Remove the front cover by squeezing the release
handles (see figure 23) and lifting the front cover up
and away from the power base.
4. Disconnect the quick release battery connectors. See
figure 23.
5. Remove the batteries.
6. Disconnect the battery harness from each battery.
7. Connect the battery harness to the new front battery
according to the battery wiring diagram. See figure 23.
WARNING!
Make sure you tighten the fasteners so that the
connections are secure.
8. Connect the battery harness to the new rear battery
according to the battery wiring diagram. See figure 23.
9. Install the new batteries and connect the quick release
battery connectors.
10. Reinstall the front cover.
11. Charge the batteries. See “Batteries and Charging.”
25
When to See Your Quantum Rehab Provider for Service
The following symptoms could indicate a serious problem
with your power chair. If necessary, contact your Quantum
Rehab Provider. When calling, have the model number,
serial number, nature of the problem, and the error code if
available.
„„ Motor noise
„„ Frayed harnesses
„„ Cracked or broken connectors
„„ Uneven wear on any of the tires
„„ Jerky motion
„„ Pulling to one side
„„ Bent or broken wheel assemblies
„„ Does not power up
„„ Powers up, but does not move
„„ Loose seat or seating components
Corrective Maintenance
If the battery condition meter does not light up when you turn
on the power:
„„ Check the harness connections. Make sure they are
tight.
„„ Check the circuit breaker. Reset it if necessary.
„„ Check the battery connections.
If the above conditions prove normal, you can load test the
batteries with a battery load tester. These testers are available
at automotive parts stores. Disconnect both batteries before
load testing and follow the directions that come with the load
tester. If either one of the batteries fails the load test, replace
both of them. If your power chair still does not power up,
contact your Quantum Rehab Provider.
26
NOTES
SAFETY GUIDELINES
WARNING!
A Quantum Rehab Provider or a qualified technician
must perform the initial setup of this power chair and
must perform all of the procedures in this manual.
The symbols below are used throughout this owner’s manual
and on the power chair to identify warnings and important
information. It is very important for you to read them and
understand them completely.
WARNING!
Indicates a potentially hazardous condition/situation.
Failure to follow designated procedures can cause either
personal injury, component damage, or malfunction. On
the product, this icon is represented as a black symbol
on a yellow triangle with a black border.
MANDATORY!
These actions should be performed as specified. Failure
to perform mandatory actions can cause personal injury
and/or equipment damage. On the product, this icon is
represented as a white symbol on a blue dot with a white
border.
PROHIBITED!
These actions are prohibited. These actions should
not be performed at any time or in any circumstances.
Performing a prohibited action can cause personal
injury and/or equipment damage. On the product, this
icon is represented as a black symbol with a red circle
and red slash.
Quick Reference Information
Quantum Rehab Provider:
Address:
Phone Number:
Purchase Date:
Copyright © 2018
INFMANU4620/Rev H/April 2018
Intended Use
The intended use of the Pride Mobility Products device is to
provide mobility to persons limited to a seated position that
have the capability of operating a powered wheelchair.
Regarding Devices for Prescription Use
WARNING!
CAUTION! Federal law restricts this device to sale by or
on the order of a physician or other certified personnel
licensed by the law of the State (US only) or region in
which this personnel practices to use or order the use
of the device.
NOTE: This owner’s manual is compiled from the latest
specifications and product information available at
the time of publication. We reserve the right to make
changes as they become necessary. Any changes to
our products may cause slight variations between the
illustrations and explanations in this manual and the
product you have purchased. The latest/current version
of this manual is available on our website.
NOTE: This product is compliant with WEEE, RoHS, and
REACH directives and requirements.
NOTE: This
(IEC 60529).
product
meets
IPX4
classification
NOTE: This product and its components are not made
with natural rubber latex. Consult with the manufacturer
regarding any after-market accessories.
USA
401 York Avenue
Duryea, PA 18642
Canada
5096 South Service Road
Beamsville, Ontario L0R 1B3
Australia
20-24 Apollo Drive
Hallam, Victoria 3803
www.quantumrehab.com.au
New Zealand
38 Lansford Crescent
Avondale
Auckland, New Zealand 1007
www.pridemobility.co.nz
UK
32 Wedgwood Road
Bicester, Oxfordshire OX26 4UL
www.quantumrehab.co.uk
B.V.
(Authorised EU Representative)
De Zwaan 3
1601 MS Enkhuizen
The Netherlands
www.quantumrehab.eu
Italy
Via del Progresso, ang. Via del Lavoro
Loc. Prato della Corte
00065 Fiano Romano (RM)
www.quantumrehab-italia.it
France
26 rue Monseigneur Ancel
69 800 Saint-Priest
www.quantumrehab.fr
Spain
Calle Velazquez 80 6D
28001 Madrid
www.quantumrehab.com
Serial #
UDI
UDILabel
Label(if(ifapplicable)
applicable)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement