Sinclair MV-H09BIS/W WALL MOUNTED UNITS SPECTRUM User Manual

Add to my manuals
32 Pages

advertisement

Sinclair MV-H09BIS/W WALL MOUNTED UNITS SPECTRUM User Manual | Manualzz
Operation Notices
Content
The Refrigerant......................................................................................................1
Precautions............................................................................................................2
Parts Name............................................................................................................7
ScreenOperation Guide
Buttons on remote controller .................................................................................9
Introduction for icons on display screen.................................................................9
Introduction for buttons on remote controller .......................................................10
Introduction for special function ...........................................................................16
Operation guide ...................................................................................................18
Replacement of batteries in remote controller .....................................................18
Emergency operation ..........................................................................................19
Maintenance
Clean and Maintenance.......................................................................................19
Malfunction
Malfunction analysis ............................................................................................22
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service
center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
Frequency band(s) in which the radio equipment operates:2400MHz-2483.5MHz
Maximum radio-frequency power transmitted in the frequency band(s) in which the radio equipment
operates:20dBm
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
R32: 675
Explanation of Symbols
DANGER
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
NOTICE
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Appliance filled with flammable gas R32.
Before use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than Xm 2 .(Please refer to table "a" in section of " Safety Operation of Inflammable
Refrigerant" for Space X.)
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigrants not contain odour. Read specialist’s
manual.
1
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
2
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
3
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table.Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
4
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
5
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
Working temperature range
For some models:
Maximum cooling
Maximum heating
Indoor side DB/WB(℃ )
32/23
27/-
Outdoor side DB/WB(℃ )
43/26
24/18
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
-15℃ ~ 43℃ ; for heat pump unit is -15℃ ~ 43℃ .
For
ASH-18BIS2, ASH-24BIS2
For models:
models:GWH18YE-S6DBA2A、GWH24YE-S6DBA2A
Indoor side DB/WB(℃ )
Outdoor side DB/WB(℃ )
Maximum cooling
32/23
52/32
Maximum heating
27/24/18
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
-18℃ ~ 52℃ ; for heat pump unit is -30℃ ~ 52℃ .
6
Parts Name
Indoor Unit
air inlet
panel
filter
aux.button
horizontal louver
air outlet
(Display content or position may be different from above
graphics, please refer to actual products)
NOTICE:
remote control
Actual product may be different from above graphics, please refer to actual
products.
7
Parts Name
Display
For some model:
For some model:
cooling
indicator
power
indicator
temp.
indicator
heating
indicator
receiver
window
display
cooling
indicator
heating
indicator
temp.
indicator
drying
display
indicator
For some model:
drying
indicator
For some model:
drying
indicator
temp.
indicator
power
indicator
heating
indicator
cooling
indicator
receiver
window
power
indicator
Power indicatior
temp.
indicator
display
receiver
window
For some model:
receiver
window
display
temp.
indicator
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
receiver
window
Mode LED color indicator:
W
R
White-W-Cool Mode-
G
Red-R-Heat Mode-
For some model:
R
(only for heating model)
Green-G-Dry Mode- G
display
temp.
indicator
W
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
receiver
window
Mode LED color indicator:
W
R
O
White-W-Cool ModeRed-R-Heat Mode-
R
W
(only for heating model)
Orange-O-Dry Mode- O
Display content or position may be different from above graphics, please refer to actual
products.
8
Buttons on remote controller
1 ON/OFF button
2 FAN button
3 MODE button
4 +/- button
5 TURBO button
6
button
2
2
5
4
11
3
9
1
13
6
4
3
8
12
10
14
WiFi
16
7
7
8 CLOCK button
1
15
9 TIMER ON/
TIMER OFF button
10 TEMP button
11
(before opening cover
(after opening cover
button
/
button
12 I FEEL button
1 ON/OFF button
13 LIGHT button
2 FAN button
14 WiFi button
3 MODE button
15 QUIET button
4 +/- button
16 SLEEP button
Introduction for icons on display screen
I feel
Quiet
Set fan speed
Turbo mode
Send signal
Healthy mode
Scavenging functions
8℃ heating function
Set temperature
This is a general remote controller. Some
models have this function while some do
not. Please refer to the actual models.
X-FAN function
Set time
TIMER ON /TIMER OFF
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
Clock
Sleep mode
Child lock
Up & down swing
Left & right swing
Light
Temp. display type
: Indoor ambient temp.
: Outdoor ambient temp.
: Set temp.
Introduction for buttons on remote controller
Note:
●This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model don't have, if press the
corresponding button on the remote controller that the unit will keep the original
running status.
● After putting through the power, the air conditioner will give out a sound.
Operation indictor " " is ON (red indicator the colour is different for different
models). After that, you can operate the air conditioner by using remote controller.
● Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display
of remote controller (If timer on, timer off and light functions are set, the corresponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
1
ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
2
FAN button
Press this button, Auto, Low, Medium-low, Medium, Medium-high, High speed can
be circularly selected. After powered on, Auto fan speed is default. Under DRY
mode, Low fan speed only can be set up.
ATUO
Low fan
Medium-low fan
Medium-high fan
Note:
Medium fan
High fan
● It’s Low fan speed under Dry mode.
● X-FAN function:Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is
displayed and the indoor fan will continue operation for a few minutes in order to dry
the indoor unit even though you have turned off the unit. After energization, X-FAN
OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be blowed
after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit by pressing ON/OFF
button indoor fan will continue running for a few minutes. at low speed. In this
period, Hold fan speed button for 2s to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by pressing ON/OFF
button, the complete unit will be off directly.
10
Introduction for buttons on remote controller
3
MODE button
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto
mode is default while power on. Under Heat mode, the initial value is 28 ℃(82 ℉)
Under other modes, the initial value is 25 ℃(77℉).
AUTO
FAN
COOL
DRY
HEAT
(only for cooling and heating unit. As for cooling only unit, it won’t have any action
when it receives the signal of heating operation.)
4
+/- button
Press " + " or " - " button once increase or decrease set temperature 1°C(°F).
Holding " + " or " - " button, set temperature on remote controller will change
quickly. On releasing button after setting is finished, temperature indicator
on indoor unit will change accordingly.
When setting TIMER ON, TIMER OFF or CLOCK, press " + " or " - " button to
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting
TIMER ON, TIMER OFF or CLOCK, press " + " or " - " button to adjust time. (Refer
to CLOCK, TIMER ON, TIMER OFF buttons)
5
TURBO button
Under Cool or Heat mode, press this button can turn on or turn off the Turbo function.
After the Turbo function turned on, the signal of Turbo will display. The signal will
be automatically cancelled if changing the mode or fan speed.
6
button
Press this button to set left & right swing angle cycling as below:
OFF
7
button
Press this button to set swing angle, which circularly changes as below:
OFF
This remote controller is universal. If it receives threes kinds of following status, the
1
Introduction for buttons on remote controller
swing angle will remain original.
If guide louver is stopped when it is swinging up and down, it will remian its present
position.
indicates guide louver swings back and forth in the five places, as shown in the figure.
8
CLOCK button
Press this button, the clock can be set up, signal blink and display. Within 5 seconds,
the value can be adjusted by pressing + or - button, if continuously press this button for 2
seconds above, in every 0.5 seconds, the value on ten place ofMinutewill be increased 1.
During blinking, repress the Clock button or Confirm button, signal will be constantly
displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to
display and signal will be displayed. If there is signal be displayed that denotes
the current time value is Clock value, otherwise is Timer value.
9
TIMER ON/TIMER OFF button
Timer On setting: Sign al “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by
pressing + or - button to adjust the time value of numerical section, every press of
that button, the value will be increased or decreased 1 minute. Hold pressing + or button, 2 seconds later, it quickly change, the way of change is: During the initial
2.5 seconds, ten numbers change in the one place of minute, then the one place
is constant, ten numbers change in the tens place of minu te at 2.5 seconds speed
and carry. During 5s blink, press the Timer button, the timer setting succeeds. The
Timer On has been set up, repress the timer button, the Timer On will be canceled.
Before sett ing the Timer, please adjust the Clock to the current actual time.
One press this key to enter into TIMER OFF setup, in which case the TIMER OFF
icon will blink. The method of setting is the sameas for TIMER ON.
10
TEMP button
Press this button, you can see indoor set temperature, indoor ambient temperature
or outdoor ambient temperature on indoor unit’s display. The setting on remote controller is selected circularly as below:
no display
When selecting " " with remote controller or no display, temperature indicator on
indoor unit displays set temperature; When selecting " " with remote controller,
temperature indicator on indoor unit displays indoor ambient temperature; When
selecting " " with remote controller, temperature indicator on indoor unit displays
outdoor ambient temperature. 3s later it will return to the setting temprature or it
depends on the other received signal within 3s.
1
Introduction for buttons on remote controller
Attention: When displaying the outdoor ambient, the displaying range is 0-60℃
When it goes beyond the range, it keeps the threshold data (the smallest—0℃
and the largest 60℃).
Warm tips: When operating buttons on the cover please make sure the cover is
closed completely.
Note: Outdoor temperature display is not available for some models. At that time,
indoor unit receives "
11
/
" signal, while it displays indoor set temperature.
button
Press this button to achieve the on and off of healthy and scavenging functions in
operation status. Press this button for the first time to start scavenging function;
LCD displays " " . Press the button for the second time to start healthy and scavenging functions simultaneously; LCD displays " " and " ". Press this button
for the third time to quit healthy and scavenging functions simultaneously. Press the
button for the fourth time to start healthy function; LCD display " " . Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.
12
I FEEL button
Press this button once, to turn on the I FEEL function, then the figure of "I FEEL"
will be displayed, after every press of other function button, every 200ms to send
I FEEL once, after this function started, the remote controller will send temperature
to the main un it in every 10 minutes. When repress this button, this function will be
turned off. When I FEEL function is turned on, the remote controller should be put
within the area where indoor unit can receive the signal sent by the remote controller.
13
LIGHT button
14
WiFi button
Press this button at unit On or Off status, Light On and Light Off can be set up.
After powered on, Light On is defaulted.
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is
turned on, the " WiFi " icon will be displayed on remote controller; Under status
of remote controller off, press "MODE" and " WiFi " buttons simultaneously for 1s,
WiFi module will restore to factory default setting.
● This function is only available for some models.
1
Introduction for buttons on remote controller
15
QUIET button
Press this button, the Quiet status is under the Auto Quiet mode (display " "
and "Auto" signal) and Quiet mode (display " " singal) and Quiet OFF (there
is no signal of " " displayed), after powered on, the Quiet OFF is defaulted.
Under the Quiet mode (Display "
" signal).
The Quiet function is only available for some models.
16
SLEEP button
Press this button, can select Sleep 1 (
), Sleep 2 (
), Sleep 3 (
) and
cancel the Sleep, circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for one hour,
the main unit setting temperature will increase 1℃, 2 hours, setting temperature
increased 2 ℃, the unit will run at this setting temperature; In Heat mode:sleep
status after run for one hour, the setting temperature will decrease 1 ℃, 2 hours,
setting temperature will decrease 2℃, then the unit will run at this setting
temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting
a group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16℃-23℃, after turned on Sleep function,
the temperature will be increased 1℃ in every hour, after 3℃ the temperature
will be maintained, after 7hours, the temperature will be decreased 1℃, after
that the unit will keep on running under this temperature;
(2) When setting the initial temperature 24℃-27℃, after turned on Sleep function,
the temperature will be increased 1℃ in every hour, after 2℃ the temperature
will be maintained, after 7hours, the temperature will be decreased 1℃, after
that the unit will keep on running under this temperature;
(3) When setting the initial temperature 28℃-29℃, after turned on Sleep function,
the temperature will be increased 1℃ in every hour, after 1℃ the temperature
will be maintained, after 7hours, the temperature will be decreased 1℃, after
that the unit will keep on running under this temperature;
(4) When setting the initial temperature 30℃, under this temperature setting, after
7hours, the temperature will be decreased 1℃, after that the unit will keep on
running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16℃, it will run under this setting temperature all along.
1
Introduction for buttons on remote controller
(2) Under the initial presetting temperature17℃-20℃, after Sleep function started
up, the temperature will decrease 1℃ in every hour, after 1℃ decreased, this
temperature will be maintained.
(3) Under the initial presetting temperature 21℃-27℃, after Sleep function started
up, the temperature will decrease 1℃ in every hour, after 2℃ decreased, this
temperature will be maintained.
(4) Under the initial presetting temperature 28℃-30℃, after Sleep function started
up, the temperature will decrease 1℃ in every hour, after 3℃ decreased, this
temperature will be maintained.
Sleep 3 - the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote controller enters into user individuation sleep setting status, at this time, the time of remote
controller will display "1hour", the setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink (The first entering
will display according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting temperature,
after adjusted, press "Trubo" button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the
remote controller, (that are "2hours" or "3hours" or "8hours"), the place of setting temperature "88" will display the corresponding temperature of last setting
sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8hours temperature setting finished,
sleep curve setting finished, at this time, the remote controller will resume the
original timer display; temperature display will resume to original setting temperature.
Sleep3 - the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep
curve, enter into user individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there
is no button pressed, the sleep curve setting status will be automatically quit
and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF" button, "Mode" button, "Timer" button or "Sleep"
button, the sleep curve setting or enquiry status will quit similarly.
1
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected, the unit will be in accordance with the room temp.
automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so
that the ambient temp. approachs the preset temp. as soon as possible.
About lock
Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon
will be displayed on it, in which case, press any button,
the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than 2s, the m ain unit will swing
backand forth from up to down , and then loosen the button, the unit will stop swing
and present position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to
, if press
this button again 2s later,
status will switch to off status directly; If press this button
again within 2s, the change of swing status will also depend on the circulation sequence stated above.
About swing left and right
1. Press swing left and right button continuously more than 2s, the main unit will swing
back and forth from left to right, and then loosen the button, the unit will stop swing
and present position of guide louver will be kept immediately.
2. Under swing left and right mode, when the status is switched from off to
, if press
this button again 2s later,
status will switch to off status directly; if press this button
again within 2s, the change of swing status will also depend on the circulation sequence stated above.
1
Introduction for special function
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch ℃ and ℉.
Combination of "TEMP" and "CLOCK" buttons:
About Energy - saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving function. Nixie tube on the remote controller displays “SE”. Repeat the operation to quit
the function.
Combination of "TEMP" and "CLOCK" buttons:
About 8℃ Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8℃ Heating Function
Nixie tube on the remote controller displays “ ” and a selected temperature of “8℃”.
(46℉ if Fahrenheit is adopted). Repeat the operation to quit the function.
About Quiet function
When quiet function is selected:
1. Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or when
indoor ambient temperature≤28℃, indoor fan will operate at notch 2 speed or quiet
mode according to the comparison between indoor ambinet temperature and set temperature.
2. Under heating mode: indoor fan operates at notch 3 speed or quiet mode according
to the comparison between indoor ambient temperature and set temperature.
3. Under dry, fan mode: indoor fan operates at quiet mode.
4. Under auto mode: the indoor fan operates at the auto quiet mode according to actual
cooling, heating or fan mode.
About Sleep function
Under the Fan、Dry and Auto mode, the Sleep function cannot be set up, Select and
enter into any kind of Sleep mode, the Quiet function will be attached and stared,
different Quiet status could be optional and turned off.
1
Operation guide
General operation
4
1. After powered on, press ON/OFF button, the unit will start
to run. (Note: When it is powered on, the guide louver of
main unit will close automatically.)
2. Press MODE button, select desired running mode.
3. Pressing + or - button, to set the desired temperature.
4. Pressing FAN button, set fan speed, can select AUTO FAN,
LOW, MEDIUM-LOW, MEDIUM, MEDIUM-HIGH and HIGH.
5. Pressing and button, to select the swing.
3
5
2
1
WiFi
Optional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the
scheduled timer on or timer off.
3. Press LIGHT button, to control the on and off of the
displaying part of the unit (This function may be not
available for some units).
4. Press TURBO button, can realize the ON and OFF of
TURBO function.
4
2
3
1
WiFi
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
battery
reinstall
remove
Cover of battery box
NOTICE
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
1
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
Clean and maintenance
WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
1
Clean and Maintenance
1
Open panel
3
Pull out the panel to a certain
● Use dust catcher or water to
the water (below 45℃ ) to clean
it, and then put it in a shady
and cool place to dry.
2
4
panel cover tightly.
WARNING
operation environment, clean frequency can be increased.
Clean and Maintenance
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
NOTICE: Checking after use-season
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
2
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
Phenomenon
Check items
Solution
● Whether it's interfered severely ● Pull out the plug. Reinsert
(such as static electricity, stable the plug after about 3min, and
voltage)?
then turn on the unit again.
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
● Whether remote controller is
within the signal receiving
range?
● Signal receiving range is 8m.
● Whether there are obstacles?
● Remove obstacles.
● Select proper angle and point
● Whether remote controller is
pointing at the receiving
the remote controller at the rewindow?
ceiving window on indoor unit.
● Is sensitivity of remote contro- ● Check the batteries. If the
power of batteries is too low,
ller low; fuzzy display and no
please replace them.
display?
● Check whether remote cont● No display when operating
roller appears to be damaged.
remote controller?
If yes, replace it.
● Fluorescent lamp in room?
● Take the remote controller
close to indoor unit.
and then try it again.
No air
emitted
from
indoor
unit
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set
temperature?
● After reaching to set temperature, indoor unit will stop blowing out air.
● Heating mode is turned on just ● In order to prevent blowing
now?
out cold air, indoor unit will be
started after delaying for several minutes, which is a normal phenomenon.
2
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Cooling
(heating)
effect is
not good.
Check items
Solution
● Power failure?
● Wait until power recovery.
● Is plug loose?
● Reinsert the plug.
● Air switch trips off or fuse is
burnt out?
● Ask professional to replace
air switch or fuse.
● Wiring has malfunction?
● Ask professional to replace it.
● Unit has restarted immediately
● Wait for 3min, and then turn
after stopping operation?
on the unit again.
● Whether the function setting
for remote controller is
correct?
● Reset the function.
● Indoor temperature and humidity is high?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
● Unit is operating under auto
mode?
● Temperature can’t be adjusted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Your required temperature
exceeds the set temperature
range?
● Set temperature range:
16℃ ~30℃ .
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty?
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open?
● Close door and window.
2
Malfunction analysis
Phenomenon
Odours are
emitted
Air conditioner operates
abnormally
“Water
noise
Cracking
noise
Check items
Solution
● Whether there’s odour source, ● Eliminate the odour source.
such as furniture and cigarette,
etc.
● Whether there’s interference,
such as thunder, wireless
devices, etc.
● Air conditioner is turned on or
turned off just now?
● Air conditioner is turned on or
turned off just now?
2
● Disconnect power, put back
power, and then turn on the
unit again.
● The noise is the sound of
the unit, which is a normal
phenomenon.
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Error code
E5
E8
H6
Troubleshooting
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
C5
F0
F1
F2
H3
E1
E6
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
Note: If there're other error codes, please contact qualified professionals for
service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and disconfor service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Air switch trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
25
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.
Installation notes
The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).
It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.
table a - Minimum room area ( m 2 )
Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9
floor location
Minimum
room window mounted
area( m 2 )
wall mounted
ceiling mounted
2
2.1 2.2
2.3 2.4
2.5
/
14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6
/
5.2 6.1
/
1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6
/
1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1
7
7.9 8.9
10 11.2 12.4 13.6 15 16.3 17.8 19.3
5
5.5
6
3.4 3.7
4
Maintenance notes
Check whether the maintenance area or the room area meet the requirement of the
nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the
nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
- The naked flame is prohibited in the maintenance area; and the “no smoking”
warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
26
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT
MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintenance and the liquidation must be
carried out by qualified personnel.
Type of refrigerant: R32
The quantity of the refrigerant: please see the unit label.
The value GWP: 675 (1 kg R32 = 0,675 t CO2 eq)
GWP = Global Warming Potential
Appliance filled with flammable gas R32.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
London W1F 7LD
Great Britain
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic
TECHNICAL SUPPORT
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic
Tel.: +420 800 100 285
Fax: +420 541 590 124
www.sinclair-solutions.com
[email protected]

advertisement