Sinclair SDT-ASH DIAGNOSTIC TOOL User Manual

Sinclair SDT-ASH DIAGNOSTIC TOOL User Manual
EN
USER'S MANUAL
DIAGNOSTIC TOOL FOR SPLIT
WALL MOUNTED SERIES
SDT-ASH
Brief Introduction
Scope of Application
It is applicable to one-to-one wall-mounted type inverter units.
Parameters of Tester
SDT-ASH
Model
Rated Voltage
230V
Rated Frequency
50Hz
Rated Current
3mA
185×140×40(mm)
Dimensions
Basic Principle
Connect the tester to communication line of the unit in parallel as shown below:
Indoor Unit
AC-L
AC-L
AC-N
AC-N
COM ODU
COM IDU
COM
AC-L
Outdoor Unit
AC-N
Tester of Inverter Unit
Functions
1.Self-diagnosis of Indoor and Outdoor Units:
Monitor and display communication data of the unit. If it fails, it will
automatically turn to simulation test to test indoor and outdoor unit step
by step.Finally,it will judge which malfunction it is.
2. Test Indoor Unit:
If there is communication malfunction or malfunction of indoor unit needs to
be independently inspected, tester will simulate outdoor unit to communicate
with indoor unit and meanwhile intercept and capture data of indoor unit.
3. Test Outdoor Unit:
If there is communication malfunction or malfunction of outdoor unit needs
to be independently inspected, tester will simulate indoor unit to communicate
with outdoor unit and meanwhile intercept and capture data of outdoor unit.
In this mode, data of remote control can be directly received.
1
Operation
Description of Appearance and Buttons
There is LCD and buttons on tester to facilitate the operation. LCD display
the user’s menu and useful information. Buttons is used for choosing operation.
Backlight of LCD is controlled by program. At the beginning of energization,
the backlight will be on for 5 seconds as default. If there is no button pressed
within 5 seconds, it will be off automatically. Besides, it will be on for 10
seconds. If button is not pressed within 10 seconds, it will be off automatically.
Appearance is as shown below:
Back to previous page
Down
Up
Enter selected item
Power cord is three-core. Brown wire connects to live wire, blue wire connects
to neutral wire and black wire connects to communication wire. Connect
them to indoor unit or patching board of outdoor unit as shown in the picture.
2
Introduction to Wiring
Self-diagnosis for Wiring of Indoor and Outdoor Units
Connect three-core wire to patching board of indoor unit or outdoor unit.
Connect wire according to corresponding wire. Live wire connects to terminal
of live wire (brown); neutral wire connects to terminal of neutral wire (blue);
communication wire connects to terminal of communication wire (black).
In that case, communication wire of tester, indoor unit and outdoor unit
are connected in parallel.
Wiring for Testing Indoor Unit
When self-diagnosis fails and it needs to manually test indoor unit, only
tester and indoor unit shall be connected and communication wire of outdoor
unit shall be disconnected.
Connection of neutral and live wire is the same as self-diagnosis of
indoor and outdoor units and indoor unit shall be turned on.
Wiring for Testing Outdoor Unit
When self-diagnosis fails and it needs to manually test outdoor unit,
only tester and outdoor unit shall be connected and communication wire of
indoor unit shall be disconnected.
Connection of neutral and live wire is the same as self-diagnosis of
indoor and outdoor units and outdoor unit shall be turned on.
3
Process of Self-diagnosis of Indoor and Outdoor Units
Instruction of operation procedure
Interface of Choosing Function
After connecting three-core wire as
per the method above, energize the unit
and the tester will enter welcome interface.
In 1 second later, it will automatically
change to function selection interface.
There are three items in function
selection interface:self-diagnosis, test IDU
and test ODU. Press button“▲” or “▼”
to choose expected function and then press
button “ENTER” to enter the function.
There are two methods to choose
self-diagnosis. One is the method set forth above.
The other is that don’t press any button
within 5 seconds and then the system will
automatically enter self-diagnosis.
Test Interface
After choosing function, tester will intelligently identify communication circuit and protocol
of the unit. During this period,“self-diagnosis
under testing…” is displayed.
Interface display
Inverter checker
function selection:
self - diagnosis
test IDU
test ODU
self - diagnosis
under testing...
Error of Self-diagnosis Interface
If the tested unit has communication
malfunction, the tester can’t monitor communication data of the unit and the self-diagnosis
will fail. In that case, tester will automatically
turn to simulation test to judge where the
communication malfunction comes from.
communication error
testing ODU...
communication error
testing IDU...
4
Process of Self-diagnosis of Indoor and Outdoor Units
Auto simulation will test indoor and outdoor units as set procedure
and the result is shown below:
communication error
with IDU and ODU...
communication error
with indoor unit
communication error
with outdoor unit
Interface of Successful Self-diagnosis
When the tested unit has no communication
malfunction, the self-diagnosis will be successful.
The tester will turn to interface of successful
self-diagnosis.
Press button“▲”or “▼”to view
information of malfunction. If there is
malfunction, the malfunction will be displayed
as shown below.
The second row is “ check IDU’s data”;
self - diagnosis done!
1. check IDU’s data
2. check ODU’s data
malfunction display:
2. check ODU’s data
malfunction display:
mismatch of IDU and
ODU error
the third row is “ check OUD’s data”. Press
button“▲”or“▼”to choose expected item
and press button “ENTER” to enter
corresponding interface.
Interface of Operation Information
Operation information includes information
of all communication data. Press button “▲” or
“▼” to change page, which is shown as below.
Press button “BACK” to return to previous
interface, view information of malfunction or
enter function selection interface.
5
ON/OFF status: ON
running mode:
cooling
speed of indoor fan:
Process of Testing Indoor Unit
When the unit has communication malfunction which causes failure
of self-diagnosis or malfunction of indoor unit needs to be independently
inspected, it will turn to manual testing mode. This section is the process
of manual test for indoor unit.
When the unit is de-energized, connect three-core wire to patching board
of indoor unit as per corresponding color. Live wire connects to terminal
of live wire (brown); neutral wire connects to terminal of neutral wire(blue);
communication wire connects to terminal of communication wire (black).
Note: in that case, communication wire of tester and indoor unit shall be
connected in parallel. Suspend the communication wire of outdoor unit and
don’t let it contact with other conducting body.
Instruction of operation procedure
Interface display
Function Selection Interface
Once the unit is energized, it will
enter welcome interface and 1 second later,
it will automatically turn to function selection
interface. Press button selection interface.
Press button“▲”or “▼”to select “ test
IDU” function and press button” ENTER” to
enter it, which is as shown below.
Prompting Interface for Disconnecting
Wire
After entering the function, system will
show “ disconnect communication wire of ODU”.
In that case, user shall confirm if communication
wire of outdoor unit has been removed form
patching board. If not, disconnect the communication wire after de-energization. Then
energize it and enter the function again.
After confirming that the communication
wire of outdoor unit has been disconnected,
press button “ENTER” to enter test interface
to start the test.
Test Interface
“test IDU under testing” is displayed
and it starts to test the unit.
6
function selection:
self - diagnosis
test IDU
test ODU
disconnect communication wire of ODU
test IDU
under testing. . .
Process of Testing Indoor Unit
Failure of Manual Test
When manual test for indoor unit fails,
“test IDU communication error with indoor
unit” will be displayed on tester.
test IDU
communication error
with indoor unit.
Successful Test for Indoor Unit
When tested unit has no communication
malfunction, tester will simulate outdoor unit
to communicate with indoor unit as per set
communication data of outdoor unit. In that
IDU test succeeded!
1. check IDU’s data
2. check ODU’s data
malfunction display:
case, tester will automatically turn to successful
interface which is shown as below.
View of malfunction and operation data is
the same as self-diagnosis function.After the
test for indoor unit is successful, tester will
keep communicating with indoor unit.
If communication fails, “ IDU data is not
received” will be displayed.
7
IDU data is not
received
Process of Testing Outdoor Unit
When the unit has communication malfunction which causes failure
of self-diagnosis or malfunction of outdoor unit needs to be independently
inspected, it will turn to manual testing mode. This section is the process of
manual test for outdoor unit.
When the unit is de-energized, connect three-core wire to patching board
of outdoor unit as per corresponding color. Live wire connects to terminal
of live wire (brown); neutral wire connects to terminal of neutral wire(blue);
communication wire connects to terminal of communication wire (black).
Note: in that case, communication wire of tester and outdoor unit
shall be connected in parallel. Suspend the communication wire of indoor
unit and don’t let it contact with other conducting body.
Instruction of operation procedure
Interface display
Function Selection Interface
Once the unit is energized, it will enter
welcome interface and 1 second later, it will
automatically turn to function selection interface.
Press button“▲”or“▼”to select “ test ODU”
function and press button” ENTER” to enter it,
which is as shown below.
function selection:
self - diagnosis
test IDU
test ODU
Prompting Interface for Disconnecting
Wire
After entering the function, system will
show “ disconnect communication wire of
IDU”. In that case, user shall confirm if
communication wire of indoor unit has
been removed form patching board. If not,
disconnect the communication wire after
de-energization. Then energize it and enter
the function again.
8
disconnect communication wire of IDU
Process of Testing Outdoor Unit
Instruction of operation procedure
Test for Outdoor Unit
After confirming that the communication
wire of indoor unit has been disconnected,
press button “ENTER” to enter the next
step. In that case, it will prompt “normal
test” and “ fixed frequency test”. “ normal
test” is for test free frequency which can
completely simulate normal operation of
the complete unit. “fixed frequency test”
can simulate the operation process of
fixed-frequency unit which facilitate
troubleshooting and the interface is shown
below.
When select the expected item, press
button “ENTET” to enter the next step to
start the test.
Test Interface
“test ODU under testing” is
displayed and communication circuit and
communication.Protocol will be automatically
inspected. After the inspection is successful,
it will simulate indoor unit to communicate
with outdoor unit as per preset communication data. It also will turn to interface
of malfunction information to display each
kind of information.
9
Interface display
selection of ODU test
normal test
fixed frequency test
test ODU
under testing. . .
Process of Testing Outdoor Unit
Failure of Manual Test
When manual test for outdoor unit fails,
“test ODU communication error with outdoor
unit” will be displayed on tester.
test ODU
communication error
with outdoor unit
Successful Test for Outdoor Unit
When tested unit has no communication
malfunction, tester will simulate indoor unit
to communicate with outdoor unit as per set
communication data of indoor unit. In that
case, tester will automatically turn to successful
interface which is shown as below.
View of malfunction and operation data is
the same as self-diagnosis function.After the test
for outdoor unit is successful, tester will keep
communicating with outdoor unit.If communication
fails, “ ODU data is not received” will be displayed.
ODU test succeeded!
1. check IDU’s data
2. check ODU’s data
malfunction display:
ODU data is not
received
Note: Tester has infrared receiver and during manual test for outdoor unit,
remote control can be used for setting each operation mode and temperature to
the tester.
10
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
London W1F 7LD
Great Britain
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic
TECHNICAL SUPPORT
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic
Tel.: +420 800 100 285
Fax: +420 541 590 124
www.sinclair-solutions.com