4
SH
3
843 [33.2]
CENTER OF
GRAVITY
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
1/2
REV
B
WINDCHILL VERSION
B.1
SERVICE ITEM
2.4L
OIL FILL CAP
RIGHT SIDE
OIL DIP STICK
RIGHT SIDE
GENERATOR AS SHOWN
766 [1689]
OIL FILTER
RIGHT SIDE
WITH WOODEN SHIPPING SKID
802 [1769]
OIL DRAIN HOSE
RIGHT SIDE
RADIATOR DRAIN HOSE
LEFT SIDE
AIR CLEANER ELEMENT
LEFT SIDE
MUFFLER
FRONT
FAN BELT
EITHER SIDE
BATTERY
LEFT SIDE
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O.
9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
REFERENCE OWNERS MANUAL FOR PERIODIC
REPLACEMENT PART LISTINGS.
B
173
[6.8]
146
[5.8]
BATTERY 12 VOLT
NEGATIVE GROUND
TOP VIEW
RADIATOR/EXHAUST
DISCHARGE AIR
1
B
VISE ACTION LATCH,
ONE PER DOOR, ONE LIFT-OFF
DOOR PER SIDE OF GENERATOR
758 [29.8]
DOOR TYP
REAR ENCLOSURE COVER
PANEL
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
CUSTOMER ACCESS
ASSEMBLY, CONTROL PANEL
ACCESS, BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
1407 [55.4]
OVERALL
HEIGHT
LIFTING PROVISIONS
(4 PLACES)
SEE NOTE 9 AND
CENTER OF GRAVITY
DIMENSIONS
302 [11.9]
REAR TANK COVER
SEE NOTE 4
A
EXHAUST MUFFLER ENCLOSED WITHIN
GENERATOR ENCLOSURE
182
[7.2]
888 [35.0]
OVERALL WIDTH
LEFT SIDE VIEW
RIGHT SIDE VIEW
REAR VIEW
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
1954 [76.9] OVERALL LENGTH
TITLE
INSTALL CPL PROTO D2.4L SW
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
A
1322 [52.0]
3
2
ISSUE DATE:
SIZE
CAGE NO
SCALE
0.050
B
DWG NO
WT-KG
0K7002AY17
SEE ABOVE SHEET
1
REV
1 of 2
B
4
SH
3
REV
2/2
WINDCHILL VERSION
B
B.1
FUEL TANK
FUEL FILL
(2" NPT FEMALE)
1194 [47.0]
1044 [41.1]
FUEL LEVEL
GAUGE/SENDER
FUEL SUPPLY
FUEL RETURN
1
TOTAL CAPACITY
253.6 [67]
USABLE CAPACITY 230.9 [61]
INNER TANK NORMAL VENT
(2" NPT FEMALE)
CAPACITY: LITER [GALLONS]
DIMENSIONS: MM [INCH]
INNER TANK EMERGENCY VENT
(2" NPT FEMALE)
HIGH AND LOW VOLTAGE
STUB-UP AREA
B
B
786 [30.9]
STUB-UP
AREA
CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER
CONNECTION OPENING
757 [29.8]
TYP
621 [24.5]
TYP
267 [10.5]
TYP
181 [7.1]
TYP
125
[4.9]
38
[1.5]
51
[2.0]
828 [32.6]
923 [36.4]
112 [4.4]
1429 [56.2]
1554 [61.2]
1764 [69.4]
187 [7.3]
STUB-UP
AREA
REMOVABLE COVER
REMOVABLE
STUB-UP COVER
353
[13.9]
A
112 [4.4]
16.7 [.66]
MOUNTING HOLES
(8 PLACES)
19
[.7]
712 [28.0]
1242 [48.9]
1842 [72.5]
TITLE
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
INSTALL CPL PROTO D2.4L SW
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
A
851 [33.5]
TYP
888
[35.0]
3
2
ISSUE DATE:
SIZE
CAGE NO
SCALE
0.075
B
DWG NO
WT-KG
0K7002AY17
SEE ABOVE SHEET
1
REV
2 of 2