4 SH 3 NOTES: B 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES AND ACCESSORY RELAY CONNECTION (QTY 4) 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O. 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 1/2 REV WINDCHILL VERSION SERVICE ITEM 2.3L OIL FILL CAP RIGHT SIDE OIL DIP STICK RIGHT SIDE GENERATOR AS SHOWN (STEEL ENCL) 581 [1281] OIL FILTER RIGHT SIDE WITH WODDEN SHIPPING SKID 621 [1369] OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE AIR CLEANER ELEMENT EITHER SIDE MUFFLER FRONT FAN BELT EITHER SIDE BATTERY LEFT SIDE 1 WEIGHT DATA WITH EMPTY BASETANK (SEE NOTE 5) 735 [28.9] CENTER OF GRAVITY (SEE NOTE 5) WEIGHT: KG [LBS] DIMENSIONS: MM [INCH] 2" O.D. EXHAUST OUTLET RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) AIR INTAKE (BOTH SIDES) REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. B 212 [8.3] REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP 111 [4.4] BATTERY 12 VOLT NEGATIVE GROUND TOP VIEW VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR RADIATOR/EXHAUST DISCHARGE AIR ENCLOSURE PANEL MUST BE REMOVED TO FACILITATE BATTERY INSTALLATION AND REMOVAL 630 [24.8] DOOR TYP REAR ENCLOSURE COVER PANEL SEE NOTE 4 CIRCUIT BREAKER SEE NOTE 3 1236 [48.7] OVERALL HEIGHT CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 RADIATOR/EXHAUST DISCHARGE AIR REAR TANK COVER SEE NOTE 4 358 [14.1] 102 [4.0] 1380 [54.3] 1582 [62.3] OVERALL LENGTH A RIGHT SIDE VIEW EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE 776 [30.6] OVERALL WIDTH LIFTING PROVISION (4 PLACES) SEE NOTE 5, 8 & CENTER OF GRAVITY DIMENSIONS FRONT VIEW TITLE DRAWING CREATED FROM PRO/ENGINEER 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. INSTALL PROTECTOR D2.3L G16 SW GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. c GENERAC POWER SYSTEMS 2013 ELECTRONICALLY APPROVED INSIDE WINDCHILL 4 A LEFT SIDE VIEW 3 2 ISSUE DATE: SIZE B SCALE 1/2014 CAGE NO DWG NO N/A 0.050 WT-KG 0K4894A SEE ABOVE SHEET 1 REV 1 of 2 4 SH 3 2/2 REV WINDCHILL VERSION 1 FUEL FILL (2" NPT FEMALE) 1109 [43.7] FUEL LEVEL GAUGE/SENDER 997 [39.3] 841 [33.1] FUEL SUPPLY 776 [30.6] FUEL TANK EMERGENCY TANK VENT (2' NPT FEMALE) 684 [26.9] NORMAL TANK VENT (2" NPT FEMALE) 436 [17.2] TOTAL CAPACITY 169 [44] USABLE CAPACITY 151 [40] CAPACITY: LITER [GALLONS] DIMENSIONS: MM [INCH] HIGH AND LOW VOLTAGE STUB-UP B B FUEL RETURN CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING 625 [24.6] TYP 674 [26.5] STUB-UP AREA 105 [4.1] 41 [1.6] 16.7 [.66] MOUNTING HOLES (6 PLACES) 11 [.4] 51 [2.0] 100 [3.9] 1346 [53.0] 191 [7.5] STUB-UP AREA TOP VIEW 738 [29.1] REMOVABLE STUB-UP COVER 456 [18.0] 100 [3.9] TYP 739 [29.1] MOUNTING CENTERS 790 [31.1] TYP 776 [30.6] 1480 [58.3] TYP A A REAR VIEW 1582 [62.3] LEFT SIDE VIEW TITLE DRAWING CREATED FROM PRO/ENGINEER 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. INSTALL STUB-UP VIEW PROTECTOR D2.3L SINGLE WALL TANK GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. c GENERAC POWER SYSTEMS 2013 ELECTRONICALLY APPROVED INSIDE WINDCHILL 4 3 2 ISSUE DATE: SIZE CAGE NO SCALE 0.075 B 1/2014 DWG NO WT-KG 0K4894A SEE SHEET 1 SHEET 1 REV 2 of 2
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project