Generac 50kW RD05034GDAL Standby Generator Manual
Add to my manuals2 Pages
Generac 50kW RD05034GDAL will provide you with high-quality performance. With 70500 Rated Watts, 55000 Running Watts, and a 120/240 Volts AC output, it can power anything from your home to your business. The Generac 50kW RD05034GDAL is powered by a 3.4L engine and has a 101-gallon fuel tank, so you can run it for hours without having to worry about refueling. It also has a variety of features that make it easy to use, including an electric start, a digital control panel, and a low-oil shutdown.
advertisement
▼
Scroll to page 2
4 REMOVE PANEL TO ALLOW TANK VENTS TO TERMINATE OUTSIDE OF THE GENERATOR ENCLOSURE (CHECK LOCAL AND STATE CODE FOR APPLICABILITY) SH 3 INTERNAL DIVIDER PANEL SEPARATES FUEL TANK VENTILATION DUCT FROM THE ENGINE, ALTERNATOR AND EXHAUST SYSTEM 998 [39.3] CENTER OF GRAVITY SEE NOTE 5 AIR INTAKE (BOTH SIDES) RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) 1/2 REV A WINDCHILL VERSION SERVICE ITEM 3.4L OIL FILL CAP RIGHT SIDE OIL DIP STICK RIGHT SIDE GENERATOR AS SHOWN (STEEL ENCL) WITH WOODEN SHIPPING SKID OIL FILTER RIGHT SIDE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE AIR CLEANER ELEMENT RIGHT SIDE MUFFLER FRONT FAN BELT EITHER SIDE BATTERY LEFT SIDE A.1 1 WEIGHT DATA WITH EMPTY BASETANK (SEE NOTE 5) 997 [2197] 1042 [2297] NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2718 (107") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR 4. REMOVE THE REAR TANK AND REAR ENCLOSRE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. ENGINE SERVICE CONNECTIONS OIL DRAIN: 3/8" NPT EXHAUST OUTLET: 2" O.D. 7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O. 9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. B 173 [6.8] 618 [24.3] LIFT-OFF DOOR PROVIDES ACCESS TO: FUEL FILL, FUEL LEVEL GAUGE, NORMAL VENT, INNER TANK TOP VIEW EMERGENCY VENT, OUTER TANK RADIATOR/EXHAUST EMERGENCY VENT, OPTIONAL DISCHARGE AIR 90% ALARM ASSEMBLY, OPTIONAL 5 GALLON SPILL 758 [29.8] BOX DOOR TYP VICE ACTION LATCH, ONE PER DOOR, LIFT-OFF DOORS ON FRONT, RIGHT, AND LEFT SIDES B LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 9, AND CENTER OF GRAVITY DIMENSIONS REAR ENCLOSURE COVER PANEL SEE NOTE 4 CIRCUIT BREAKER SEE NOTE 3 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 1449 [57.0] OVERALL HEIGHT 343 [13.5] REAR TANK COVER SEE NOTE 4 A OPEN PUNCHED LOUVERS TYPICAL ON BOTH SIDES OF FUEL TANK VENTILATION DUCT TO PROVIDE ADEQUATE CROSS-FLOW OF AIR VENTILATION DRAWING CREATED FROM PRO/ENGINEER 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. FUEL TANK VENTILATION DUCT EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE 182 [7.2] 888 [35.0] OVERALL WIDTH REAR VIEW LEFT SIDE VIEW RIGHT SIDE VIEW TITLE INSTALL CPL PROT D3.4L EXT GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. c GENERAC POWER SYSTEMS 2013 ELECTRONICALLY APPROVED INSIDE WINDCHILL 4 A 1625 [64.0] 2424 [95.4] OVERALL LENGTH 3 2 ISSUE DATE: SIZE CAGE NO SCALE 0.050 B DWG NO WT-KG 0K6968 SEE ABOVE SHEET 1 REV 1 of 2 A 4 SH 3 2/2 REV A WINDCHILL VERSION A.1 1 FUEL TANK CUSTOMER OPTION (2" FEMALE NPT) INNER TANK NORMAL VENT (2" NPT FEMALE) 351 [13.8] OUTER TANK LEAK DETECTOR OUTER TANK EMERGENCY VENT (2" NPT FEMALE) B 233 [61] 209 [55] CAPACITY: LITER [GALLONS] DIMENSIONS: MM [INCH] THIS TANK IS LISTED TO UL142 AND ULC/ORD C142.18 INNER TANK EMERGENCY VENT (2" NPT FEMALE) 101 [4.0] TOTAL CAPACITY USABLE CAPACITY HIGH AND LOW VOLTAGE STUB-UP AREA B CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING FUEL LEVEL GAUGE/SENDER 786 [30.9] STUB-UP AREA 660 [26.0] 125 [4.9] FUEL RETURN FUEL FILL (2" NPT FEMALE) FUEL SUPPLY 38 [1.5] 121 [4.8] 2226 [87.6] 51 [2.0] 196 [7.7] STUB-UP AREA REMOVABLE STUB-UP COVER 394 [15.5] 16.7 [.66] MOUNTING HOLES (10 PLACES) 110 [4.3] TYP 19 [.7] 690 [27.2] TYP A 1216 [47.9] TYP 851 [33.5] TYP A 888 [35.0] 1769 [69.6] TYP 2322 [91.4] TYP TITLE DRAWING CREATED FROM PRO/ENGINEER 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. INSTALL CPL PROT D3.4L EXT GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. c GENERAC POWER SYSTEMS 2013 ELECTRONICALLY APPROVED INSIDE WINDCHILL 4 3 2 ISSUE DATE: SIZE CAGE NO SCALE 0.075 B DWG NO WT-KG 0K6968 SEE ABOVE SHEET 1 REV 2 of 2 A
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project