Generac 27kW RG02724GNAX Standby Generator Manual

Generac 27kW RG02724GNAX Standby Generator Manual
4
SH
3
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
BATTERY 12V
GRP 26
NEGATIVE GROUND
P/N: 077483
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
B
SERVICE ITEM
2.4L
OIL FILL CAP
EITHER SIDE
OIL DIP STICK
RIGHT SIDE
OIL FILTER
RIGHT SIDE
OIL DRAIN HOSE
LEFT SIDE
RADIATOR DRAIN
LEFT SIDE
COOLANT RECOVERY BOTTLE
LEFT SIDE
RADIATOR FILL CAP
ROOF TOP
AIR CLEANER ELEMENT
LEFT SIDE
SPARK PLUGS
LEFT SIDE
MUFFLER
SEE NOTE 11
DRIVE BELT
EITHER SIDE
FAN BELT
SEE NOTE 11
BATTERY
LEFT SIDE
1/2
REV
141
[5.6]
TOP VIEW
1040
[40.9]
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
776 [30.6]
OVERALL WIDTH
FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
VICE ACTION LATCH,
ONE PER DOOR,
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
48
[1.9]
TYP
45
[1.8]
TYP
REAR VIEW
1490 [58.7] TYP
1580 [62.2]
OVERALL LENGTH
WEIGHT DATA
LEFT SIDE VIEW
ENGINE/KW
KVA
ENCLOSURE
MATERIAL
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
SHIPPING WEIGHT
KG [LBS]
2.4L 22KW (60HZ)
SINGLE PHASE 17.4KVA (50HZ)
THREE PHASE 22KVA (50HZ)
AL
410.5 [905]
30 [66]
440 [971]
2.4L 27KW (60HZ)
SINGLE PHASE 21.6KVA (50HZ)
THREE PHASE 27KVA (50HZ)
AL
426 [940]
30 [66]
456 [1006]
TITLE
DIMENSIONS: MM [INCH]
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
3
A
RIGHT SIDE VIEW
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
4
B
631 [24.8]
DOOR TYP
980
[38.6]
OVERALL
HEIGHT
48
[1.9]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
1
CIRCUIT BREAKER
SEE NOTE 3
RADIATOR/EXHAUST
DISCHARGE AIR
A
E.2
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE IS 6" OFFSET OF OVERALL LENGTH AND
WIDTH OF GENERATOR. {1082.1 (42.6") WIDE X 1884.7 (74.2") LONG}. REFERENCE
INSTALLATION GUIDE SUPPLIED WITH THE UNIT FOR CONCRETE PAD GUIDELINES.
REFERENCE MANUFACTURER'S SPECIFICATIONS IF USING ENGINEERED, PREFABRICATED SLABS.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS.
629.9 [24.8]
CENTER OF GRAVITY
(SEE NOTE 5)
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
WINDCHILL VERSION
NOTES:
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
427
[16.8]
E
2
INSTALL CPL PROT G2.4L C1
22 & 27KW
ISSUE DATE:
SIZE
B
SCALE
CAGE NO
DWG NO
N/A
0.050
WT-KG
0K8624
SEE ABOVE SHEET
1
REV
1 of 2
E
4
SH
3
2/2
REV
E
WINDCHILL VERSION
1380 [54.3] TYP
MOUNTING SLOT CENTERS
45 [1.8] TYP
E.2
1
*NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS.
CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING.
13.5 X 29.5
MOUNTING SLOTS
4X
B
HIGH AND LOW
VOLTAGE
STUB-UP AREA
B
674
[26.5]
104.5
[4.11]
*STUB-UP
AREA
53
[2.1]
100
[3.9]
*STUB-UP
AREA
1345
[53.0]
51
[2.0]
9
[.4]
226
[8.9]
REMOVABLE
STUB-UP COVER
TOP VIEW
735 [28.9]
96 [3.8]
27 [1.0]
TYP
723 [28.5] TYP
MOUNTING SLOT CENTERS
776 [30.6]
1580 [62.2]
A
TITLE
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
A
REAR VIEW
LEFT SIDE VIEW
3
2
INSTALL CPL PROT G2.4L C1
22 & 27KW
ISSUE DATE:
SIZE
B
SCALE
CAGE NO
DWG NO
N/A
0.100
WT-KG
0K8624
SEE SHEET 1 SHEET
1
REV
2 of 2
E