Generac 45kW RG04524ANAX Standby Generator Manual

Generac 45kW RG04524ANAX Standby Generator Manual
4
SH
3
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
B
SERVICE ITEM
2.4L
OIL FILL CAP
EITHER SIDE
OIL DIP STICK
RIGHT SIDE
OIL FILTER
RIGHT SIDE
OIL DRAIN HOSE
RIGHT SIDE
RADIATOR DRAIN HOSE
LEFT SIDE
COOLANT RECOVERY BOTTLE
LEFT SIDE
RADIATOR FILL CAP
ROOF TOP
AIR CLEANER ELEMENT
LEFT SIDE
SPARK PLUGS
LEFT SIDE
MUFFLER
SEE NOTE 11
DRIVE BELT
EITHER SIDE
FAN BELT
SEE NOTE 11
BATTERY
LEFT SIDE
LUBE OIL MAINTAINER
SUPPLY TANK FILL CAP
ROOF TOP
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
443
[17.5]
187
[7.4]
BATTERY 12V
GROUP 26
NEGATIVE GROUND
P/N: 077483
TOP VIEW
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
749.3 [29.5]
CENTER OF GRAVITY
(SEE NOTE 5)
REMOVE COVER FOR
ACCESS TO LUBE OIL
MAINTAINER SUPPLY TANK
REFERENCE OWNERS MANUAL
CIRCUIT BREAKER
SEE NOTE 3
D
WINDCHILL VERSION
D.1
1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE IS 6" OFFSET OF OVERALL LENGTH
AND WIDTH OF GENERATOR. {1193.8 (47") WIDE X 2255.5 (88.8") LONG}. REFERENCE
INSTALLATION GUIDE SUPPLIED WITH THE UNIT FOR CONCRETE PAD GUIDELINES.
REFERENCE MANUFACTURER'S SPECIFICATIONS IF USING ENGINEERED, PREFABRICATED SLABS.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
VICE ACTION LATCH,
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
ONE PER DOOR,
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
ONE LIFT OFF
REMOVE FRONT PANEL TO ACCESS.
759 [29.9]
DOOR PER SIDE
DOOR TYP
OF GENERATOR
888 [35.0]
OVERALL WIDTH
REAR VIEW
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
47
LOCATED WITHIN
[1.8]
SEE NOTE 4
1857 [73.1] TYP
1950 [76.8]
OVERALL LENGTH
RIGHT SIDE VIEW
A
WEIGHT DATA
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
ENGINE/KW
ENCLOSURE
MATERIAL
SHIPPING WEIGHT
KG [LBS]
2.4L 36KW
ST
569 [1255]
44 [98]
613 [1353]
2.4L 36KW
AL
545 [1202]
44 [98]
590 [1300]
2.4L 45KW
ST
596 [1313]
44 [98]
640 [1411]
2.4L 45KW
AL
572 [1260]
44 [98]
616 [1358]
TITLE
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
3
B
58
[2.3]
TYP
50
1000 [39.4]
[2.0]
FUEL LINE CONNECTION
LEFT SIDE VIEW
3/4" NPT FEMALE COUPLING
A
REV
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
1171
[46.1]
OVERALL
HEIGHT
RADIATOR/EXHAUST
DISCHARGE AIR
1/2
2
B
SCALE
CAGE NO
DWG NO
N/A
0.050
WT-KG
0K8636
SEE ABOVE SHEET
1
REV
D
1 of 2
4
SH
3
2/2
REV
D
WINDCHILL VERSION
D.1
1
13.5 X 29.5
MOUNTING SLOTS
4X
* NOTE: STUB-UP AREA FOR HIGH AND LOW
VOLTAGE CONNECTIONS, CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER CONNECTION OPENING.
B
B
HIGH AND LOW
VOLTAGE
STUB-UP AREA
786
[30.9]
162
[6.4]
* STUB-UP
AREA
9
[.4]
37
[1.5]
TOP VIEW
51
[2.0]
162 [6.4]
* STUB-UP
AREA
233
[9.2]
1708
[67.2]
REMOVABLE
STUB-UP COVER
850 [33.5]
116 [4.6]
50 [2.0]
TYP
A
25 [1.0]
TYP
1750 [68.9] TYP
MOUNTING SLOT CENTERS
838 [33.0] TYP
MOUNTING SLOT CENTERS
A
888 [35.0]
1950 [76.8]
REAR VIEW
LEFT SIDE VIEW
TITLE
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
3
2
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE
CAGE NO
B
N/A
SCALE
0.100
DWG NO
WT-KG
0K8636
SEE SHEET 1 SHEET
1
REV
D
2 of 2