Grizzly G9280 Stainless Steel Dial Caliper Owner Manual

Grizzly G9280 Stainless Steel Dial Caliper Owner Manual

Instruction Sheet For Dial Calipers

Grizzly Dial Calipers feature 0.001" resolution, a 1 1 ⁄ 2 " easy-to-read dial and precision ground stainless steel construction. Using this tool will allow you to measure internal, external and depth quickly and precisely.

Please read the instructions below to maximize the effectiveness of this tool. If you need additional help with any of these instructions, please contact our Customer Service Department at 570-546-9663 or by internet at techsupport@grizzly.com.

0

2 1 90 0 10 80 60 50 40 20 30 5 6

1 2 3 4 5 6 7 8 9 3 1 2 3 4 2 3 4 5 6 7 8 9 8

3 10 8 9 4

0

80 70 90 0 10 20 30 60 50 40 7

Listed below are the dial caliper components. Match the description with the corresponding part number in the illustration above.

1.

The distance between the equals 0.001" (one thousandths of an inch).

Figure 1.

Labels for components.

White Lines

hand is not on “0” then you can turn the dial to align it to “0”. Once aligned, lock down the bezel with the dial lock (4).

5.

The

Caliper Lock

secures the dial to the body, maintaining a measurement.

2.

The

Dial Numbers

represent 0.010" (ten thousandths of an inch).

6.

The

Inch Markers

denote each full inch of measurement.

7.

The

External Caliper Jaws

are used for external measurements.

3.

Each number on the

Revolution Scale

represents one full rotation of the needle and is equal to 0.100" (one hundred thousandths or See

Figure 2

1 ⁄ 10 of an inch). The jaw index indicates which number is read. for how the measurement is read.

8. 9.

The

Internal Jaws

are used for internal measurements.

The

Depth Blade

depth.

is used to gauge

4.

The

Dial Lock

secures the dial after zero is set. Clean the jaw faces of any dirt or dust and close the jaws together. If the 351201622

10.

The

Thumbwheel

is used to move the dial assembly along the caliper body.

© 2001 Grizzly Industrial, Inc.

Dial Calipers can measure objects with an accuracy of 0.001". Some rules of use should be observed to maximize precision.

• Wipe the jaws clean before use.

• Check the position of zero on the dial with the jaws closed and adjust if needed by loosening the dial lock and rotating the bezel.

• Always use the thumb wheel to close or open the jaws and never apply too much pressure.

• Hold the caliper perpendicular to the measured surface.

• As the jaws open, the rack is exposed. Do not allow dust and debris to settle here or accuracy will be lost and internal damage may occur.

• Do not drop the calipers.

B 0 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 2

80 90 0 10 20 60

3 1 2 3 4

40 50

8 A C

Figure 2.

Measuring 2.147".

In the illustration above, the calipers have been set at 2.147". The following describes how this measure ment was read.

The jaw index has passed the 2

Inch Mark, A.

The jaw index has passed the 1 on the

Revolution Scale, B.

The needle has passed the 40 on the

Dial Numbers.

There are 7

White Lines

after the 40 mark,

C.

The total measurement = 2.000" .100" .040" .007" 2.147" 351201622 © 2001 Grizzly Industrial, Inc.