Commax JNS-36/JNS-36O NURSE STATION Owner Manual

Commax JNS-36/JNS-36O NURSE STATION Owner Manual

User Manual NURSE CALL SYSTEM

JNS-36(Series) POWER VOLUME BUSY LOCK TONE TALK • Thank you for purchasing COMMAX products.

• Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly.

• The company is not responsible for any safety accidents caused by abnormal operation of the product.

Introduction

Established in 1968 Jung Ang Electronics Co., Ltd. has specialized in the field of intercommunication system for 27 years, and and now it is our greatest pleasure to present a highly advanced hospital communication network system which we assure to level up your hospital culture.

Nurse call system introduction

We have three types of unrse sall system as below table.

Features System System type Nurse Stations Patient Station Central controller JNS-36 Series Analogue JNS-12/24/36 JNS-101 wire 2 common+ 1 individual Max acconmodation Max 36 beds (36 stations call & communication) JNS-600 Series Analogue Digital JNS-6012M/6028M/6044M/6060M JNS-1060M/1108M JNS-102 JNS-6012, 6060 1 common+ 2 individual JNS-1050M/1050S JNS-1060, 1108 5pair(10wires)common a. Max 36 beds (30 ststions call & communication) b. 8 rooms of public toilets(emergency) JNS-1000 Series a. Max 29wards of 108 beds (1080 stations call & communication) b. Max 29 ward's shower room & toilets. (emergency function) c. 16 rooms of public toilets (emergency function) Available functions a. Corridor light a. Corridos light b. Master to Master talk (Max 6 stations) c. Call cord only.

d. Guiding light a. Corridor light/Guiding light b. Master to Master talk (max 90 stations) c. Presence switch.

d. Staff call e. Emergency switch.

f. Call cord & pillow speaker g. Compatible with TP-90AN upto 90 station's communication of nurse and staff stations.

Effective distance Max 1,000m Max 500m Max 500m - 1 -

Table of Contents

Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 Nurse call System introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 Contents table - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Manual of JNS-36 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 1. Model No - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 2. Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 3. Structure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 4. System Working diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 5. Figure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 6. Connection Diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 7. Operating Instruction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 8. Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 9. Warranty Service - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 - 2 -

Manual of JNS-36 Series

1. Model No

The model No of the nurse call system would be devided by it's accomodating interphone station number as belows; No 1 2 3 4 5 6 7 Wiring 8wire 14 wire 20 wire 26 wire 32 wire 32 wire 44 wire station number + 2wire station No 6 station 12 station 18 station 24 station 30 station 36 station 42 station add ed. up by 6 stations MODEL No JNS-6 JNS-12 JNS-18 JNS-24 JNS-30 JNS-36 JNS-42 JNS station No.

ETC Basic Case Basic Case Basic Case Basic Case Basic Case Basic Case

2. Features

2-1. Clear communicating line.

2-2. You can adjust each call volume and talk volume separatly.

2-3. When a call receiving. LED lamp turn off automatically.

2-4. When a communicating, the lamp of the line will be on.

2-5. Two way communication.

2-6. Hands-fred talk function.

- 3 -

3.STRUCTURE

3-1. MASTER STATION

BU SY POW ER LOC K VOL UM E TAL K TON E ① HAND SET : ② POWER LED : To check the Power Switch's condition.

③ POWER S/W : To provide a power.

④ C-MIC : To transmit a message.

⑤ BUSY LEN : To indicate busy line by lamp On.

⑥ LOCK BUTTON : Only to transmit a message in one way, the lamp is on.

⑦ TALK BUTTON : To press the button for talking. (during H/F communicating) ⑧ VOICE : To adjust receiving volume by three stage, High, Mid & Low.

⑨ TONE : To adjust receiving signal by three stage, High, Mid & Low.

⑩ SPEAKER : To output the message.

- 4 -

3-2. SUB STATION

CALL TALK CALL CORD MIC

4. System working diagram

① SPEAKER : ② CALL JACK : Can be connected with call cord CC-200.

③ CALL BUTTON : To call a master.

④ C-MIC : ⑤ CANCEL BUTTON : To cancel a call.

⑥ CALL LAMP : LED's off in calling.

⑦ TALK LAMP : LED's on in talking.

5. Figure

MASTER STATION (JNS-36) SUB STATION (W/ARM SWITCH) - 5 -

6. Connection diagram

common two wire and individual one wire

7. Operating Instruction

7-1. When call a sub station in master.

① Please press a select button that you want then a LED in the button is "ON".

② With hand-set communicating you can talk in two way communication.

③ Under using a intercom way of communication, You can talk through talk button.

7-2. When call a master in substation.

① With pressing the call button in substation the LED Lamp in master is "ON" and Melody is ② transmited.

The call Lamp & corrider lights will be "OFF" at same time.

③ Please press the master button or lift up the hand set to talk.

④ Please return the select button after finishing a talk.

- 6 -

8. SPECIFICATIONS

Divison Model No Wiring Power Power consumption in standdoy Max power consumption Communication Way Distance Station Number Dimension JNS-36(Series) Common 2 wires and individual 1 wire 110-220V~ (60Hz) 24V (22mA) 24V (190mA) in one line Two way communication system 600m/0.65mm

Max 36 sub stations 360( W ) x 232( D ) x 105( H )mm

9. WARRANTY SERVICE INSTRUCTIONS

If you experience a problem with your JNS-36 Nurse Call System, please refer to the "Operating Instructions" sections of this Owner's Manual to review the proper operation. Check the power source to insure adequate power available to operate the JNS-36 System.

If the JNS-36 still will not function, please return the unit (with proof of purchase) to the place of purchase.

FOR YOUR RECORDS Purchase Date: Purchased From: Serial Number: KEEP THIS INFORMATION IN A SAFE PLACE.

- 7 -

Memo

513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com

PM2736000010 Printed In Korea / 2011.04.104

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement