Commax CMA-3L/CMA-3LD MODUM AUDIO PHONE User manual

Add to My manuals
8 Pages

advertisement

Commax CMA-3L/CMA-3LD MODUM AUDIO PHONE User manual | Manualzz
User Manual
Doorphone CMA-3L / CMA-3LD
•
for purchasing
purchasing COMMAX
COMMAXproducts.
products.
• Thank
Thank you
you for
•
• Please
Please carefully
carefully read
read this
this User’s
User’sGuide
Guide(in
(inparticular,
particular,precautions
precautionsfor
forsafety)
safety)before
beforeusing
usingaaproduct
productand
andfollow
follow
instructions
instructions to
to use
use aa product
product exactly.
exactly.
•
• The
The company
company isis not
not responsible
responsible for
forany
anysafety
safetyaccidents
accidentscaused
causedby
byabnormal
abnormaloperation
operationof
ofthe
theproduct.
product.
Contents
1. Greetings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Warnings and caution . . . . . . . . . . . . . . . . . . . . . . . .2
3. Part names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4. Features & Functions . . . . . . . . . . . . . . . . . . . . . . . .4
5. Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7. Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8. Operating
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
9. Trouble shooting
10. Specification
. . . . . . . . . . . . . . . . . . . . . . . . . . .7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1. Greetings
Thank you very much for purchasing of COMMAX products.
Please read carefully this user manual and follow its rules.
This intercom can be used in offices, and shopping outlets, and provide
convenience to use communication on long distances.
2. Warnings and caution
Please follow the things described below in order to prevent any
danger or property damage.
Warning
Caution
2
It may cause a serious damage or
injury if violated.
It may cause a minor damage or
injury if violated.
Prohibition.
No disassembly
No touch
Must follow strictly.
Shows plugging out the power cord
without an exception
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
Power & Installation
Warning& Caution
Please don’t use several
products at the same time on
one power socket.
·It may cause a fire due to an
abnormal overheating.
Please don’t bend the power
cable excessively or it may
cause an electric shock.
·fire when using a damaged
power cable.
Please don’t handle the power
cable with a wet hand.
·It may cause an electric
shock.
Please plug out the power
cable from the socket when
not using it for a long period
of time.
·It may shorten the product
lifespan or cause a fire.
Please don’t install the
product in the place where
there is much oil, smoke or
humidity.
·It may cause an electric
shock or fire.
Please don’t install the
product with the lightening
and thunder.
·It may cause an electric
shock or fire.
Please don’t use and connect
this product with other
products with different rated
voltage
·It may cause a disorder or
fire.
When installing the product
that generates heat, please
install the product away from
the wall (10cm) for the
ventilation.
·It may cause a fire due to
the increased internal
temperature.
Cleaning & Use
Warning& Caution
Please don’t disassemble,
repair or rebuild this product
arbitrarily (please contact the
service center if a repair is
needed.
·It may cause an electric
shock or fire.
If an abnormal sound, burning
smell or smoke is coming out
of the product, please plug out
the power cable and contact a
service center.
·It may cause an electric
shock or fire.
Please don’t insert any
metallic or burnable materials
into the ventilation hole.
·It may cause an electric
shock or fire.
When cleaning the product,
please rub it with a soft and
dry cloth after plugging out
the power cable. (Please don’t
use any chemical products
such as wax, benzene, alcohol
or cleanser.)
3
3. Part names
CMA-3L
CMA-3LD
1.VOLUME SWITCH
2.HAND SET
3.GUARD CALL BUTTON
4.DOOR RELEASE BUTTON
5.HANDSET CORD
6.AC POWER CORD (Only CMA-3L)
※ When this product boot up, via program, check DOOR 2’s connect terminal connected with which
system. If it connected with MODUM system, it works as MODUM house hold unit, if it connected
with general door station, it works as general type house hold unit.
(when finished connecting wires, please re-boot and proceed)
4. Functions
Calling to Guard unit and talking
Door release (Interlocking with Door phone)
Talking to Common lobby and Individual front door
5. Contents
4
6 . Installation
Caution for Monitor
When to install it, avoid the place where can be influenced by Magnetism, Humidity,
Direct light and heater.
7 . Wiring
5
8. Operating
8-1. Call from the individual entrance
(1) When a visitor presses call button, with Calling sound from the speaker is emitted.
(2) For Visitors, please talk with the handset (Currency time 60 second)
(3) When lay the handset after the end of taking with a visitor, everything is done.
When a visitor is allowed to be in, the door is released with the sound, if a user
presses the Door release button.
(In case of using the Door station which is interlocked with Door released function)
(4) If guard or lobby calls during the coversation between house and individual
entrance, phone rings. If you hang up the phone and pick it up again at this time, it
will switch the phone over to guard or lobby. (Previous call is ended)
Caution : Do not hold the handset at your ear when you press hook switch to switch call.
8-2. Call from the Lobby (MODUM system only)
(1) Calling sound from the speaker is emitted when a visitor calls from Common lobby.
Pick the handset to talk this time
(2) The sound of Door station is emitted while talking over the phone with the Common
lobby.
(3) If you hang up the phone and pick it up again, the coversation with Lobby will be
disconnected, and the coversation with individual entrance will be available. If the door
release button is pressed while talking over the phone with Common lobby, the door is
released with sound and the talk is ended.
Caution: Do not hold the handset at your ear when you press hook switch to switch call.
8-3. Conversation with Guard (MODUM system only)
(1) Call from the guard
① Calling sound from the speaker is emitted when a visitor calls from Guard.
Pick the handset to talk this time
② The sound of Door station is emitted while talking over the phone with the Guard
③ If you hang up the phone and pick it up again, the coversation with Guard will be
disconnected,and the coversation with individual entrance will be available.
Caution: Do not hold the handset at your ear when you press hook switch to switch call.
(2) Calling the guard station
① You can talk with guard station by picking up the handset and pressing guard call button.
② Conversation will begin when a guard station responds.
6
9. Trouble shooting.
If you think that the product has trouble, please first check below contents before you ask a repair.
Troubles
●
●
●
●
Check Point
Actions
The power supply is
not on.
All works are stopped
1. Please connect the
1.The power supply
power supply cord
cord is missing or not.
2.
Please turn on the power
2.The power supply switch
switch pushing the left
(down) is off or not.
(down) to the right(up).
A Call operation is not
performed.
(Door, Interphone function)
1.The wiring between other
1. Please refer to connection
units is connected correctly
related page and manage.
in good order or not.
2. Please connect correctly
2. The wiring is missing or not.
to the terminal.
The product does not
produce the sound.
1. A sound volume lies
in minimum or not.
(Call volume, Talk volume)
1. Please adjust the sound
volume switch proprely
turing the left(down) to
the right(up), as you
want.
10. Specifications
CMA-3L / CMA-3LD
Power source
CMA-3L : 100/110/120/220/230/240V~, 50/60Hz
CMA-3LD : 24V --- , 1A
Power Consumption
Operating : 5W (MAX)
Wiring
3 wires with door station(Polarity)
Communication
Call Sound
Entrance : Electronic chime, Guard station : Melody
Simultaneous communication
Distance
28m(Ф0.5) / 50m(Ф0.65) / 70m(Ф0.8)
Operating Temperature
0 ~ +40℃ (32°F ~ 104°F)
Dimension[mm]
CMA-3L : 208(D) X 98(W) X 65(H)
CMA-3LD : 208(D) X98(W) X 60(H)
Reference : Design and functions of the product are a subject of constant
development as a pursuit of quality improvement
7
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133
Web site : www.commax.com
Printed In Korea / 2011.11.104

advertisement

Related manuals

advertisement