Cyclo Directional IP65 user manual
Dimensions
Measurements are in millimeters
1257 135 Height incl.
mounting bracket 242 230 230 150 121 93 ©2007 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. Information subject to change without notice. Martin Professional A/S and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. P/N 35000191, Rev. A
Safety information WARNING!
Read the safety precautions in this section before installing, powering, operating or servicing this product.
The following symbols are used to identify important safety information: Danger! Safety hazard. Risk of personal injury or death.
Danger! Hazardous voltage. Contact will cause electric shock.
Danger! Fire hazard.
Warning! Burn hazard. Hot surface. Do not touch.
DANGER! This product is not for household use. It presents risks of injury due to electric shock, fire, burns and falls if safety precautions are not followed.
Read this manual before installing, powering, operating or servicing the luminaire. Follow the safety precautions listed below, and observe all warnings in this manual and on the luminaire. Use the luminaire only as described in this manual and in accordance with local laws and regulations. Refer any operation not described in this manual to a qualified technician.
If you have any questions about how to operate this luminaire safely, contact your Martin Architectural supplier or call the Martin 24-hour service hotline on +45 70 200 201.
Protection from electric shock
• Do not use the luminaire if any cable, seal, cover, housing or other component is cracked, deformed or damaged in any way.
• Isolate the luminaire from power and lock out power before removing or installing a tube, fuses or any part
Safety information
3
4
• Always ground (earth) the luminaire electrically. • Use only a source of AC power that complies with local building and electrical codes and has both overload and ground (earth) fault protection.
• Ensure that the AC power distribution system includes a means of isolating all installed devices from power and locking out power during service.
• Ensure that all components in the AC power distribution circuits (cables, junction boxes, etc.) are protected from water and airborne particles to IP67 or higher, are suitably dimensioned for the current and power requirements of the devices installed, and are of suitable type for the location (including water, pollution, temperature and UV resistance).
• Do not expose the luminaire to a high-pressure water jet.
• Do not immerse the luminaire in water or install it in a location where flooding may occur.
• Refer all service not described in this manual to a Martin service technician.
Protection from burns and fire
• Do not operate the luminaire if the ambient temperature (T a ) exceeds 40° C (104° F). • Keep flammable materials well away from the luminaire.
• Allow the luminaire to cool for 15 minutes before servicing.
• Do not attempt to bypass thermostatic switches or fuses. Replace defective fuses with ones of the specified type and rating only.
• Do not modify the luminaire. Install only genuine Martin parts and approved fluorescent tubes of the type and wattage specified for the armature. • Provide a minimum clearance of 25 mm (1 inch) and unobstructed airflow around the luminaire.
• Do not mask or modify light output with filters or other materials.
Protection from injury due to falls
• Block access below the work area and work from a stable platform whenever installing, servicing or removing the luminaire.
• Ensure that all supporting structures, surfaces, fasteners and lifting equipment can bear the weight of all the devices they are intended to support plus an adequate safety margin, and that they conform to local building and safety regulations.
• Use fasteners that have sufficient corrosion resistance, dimensions and strength to mount the luminaire safely. Any nuts used must be self locking.
• Ensure that all components and installation fittings are securely fastened.
Cyclo IP65 Directional user manual
Contents Safety information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Included items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Access to tube module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Access to connections compartment . . . . . . . . . . . . . . . . . . . . . . . . 10 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Orientation and adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Linking luminaires for DMX and synchronized operation . . . . . . . . . 21
Operation: general
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Fluorescent tube lifetimes and performance . . . . . . . . . . . . . . . . . . . 27 Avoiding condensation and humidity. . . . . . . . . . . . . . . . . . . . . . . . . 27 Operation in extreme ambient temperatures. . . . . . . . . . . . . . . . . . . 28
Stand-alone operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Stand-alone operation settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Single stand-alone operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Master/slave stand-alone operation . . . . . . . . . . . . . . . . . . . . . . . . . 31
DMX-controlled operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DMX control functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Tube replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Main fuse replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Voltage setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Troubleshooting DMX protocols
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Cyclo IP65 Directional specifications
. . . . . . . . . . . . . . . . . 43
Product overview
D B C A
A – Tube module B – Base module C – Front cover D – Metal cable glands (if used)
6
Cyclo IP65 Directional user manual
Introduction
Thank you for selecting a luminaire from the Martin Architectural ® Cyclo IP65 Directional series. Cyclo IP65 Directional luminaires are fluorescent tube-based dynamic color-changing luminaires designed for illumination of walls and surfaces. Dimmable 54 watt T5 fluorescent tubes combine high efficiency, bright color and long lamp life. Luminaires are designed for surface mounting, and adjustable arms allow tilting through a wide range of angles.
Cyclo IP65 Directional luminaires offer independent 0-100% control of tube intensity using a standard DMX controller. They can also be programmed to run stand-alone light shows alone or in synchronized groups.
Two models are available. The 03 has red, green and blue tubes, allowing RGB additive color mixing. The 04 has red, green and blue tubes plus a cool daylight white tube, allowing RGBW color mixing. The color temperature of the white tube’s output can be controlled using the colored tubes.
Luminaires are dustproof and protected from water projections and low pressure water jets to IP65. A self-purging humidity valve eliminates condensation. Luminaires can start and operate with tubes dimmed to 1% light output in ambient temperatures as low as -20° C (-4° F).
Versions are available to suit the following voltage ranges: • 120 V models accept 100-130 V nominal AC power at 50/60 Hz.
• 230 V models accept 200-240 V nominal AC power at 50/60 Hz.
Martin Architectural can offer expert assistance with planning an installation, if desired.
Installation, on-site service and maintenance can be provided worldwide by the Martin ® Global Service organization and its authorized agents. Choosing a Martin service contract gives owners access to Martin’s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product’s lifetime.
The most recent version of this user manual is available from the Support area of http://www.martin-architectural.com
Introduction
7
Installation
” on page 3 before attempting to
install this product.
The safety and suitability of lifting equipment, installation location, anchoring method, mounting hardware and electrical circuits are the responsibility of the installer. All local safety regulations and legal requirements must be observed when installing and connecting the Cyclo IP65 Directional. Installation must be carried out by qualified professionals only.
This section describes how to install the luminaire, including how to connect it to power and control data cables, and how to set it up for DMX control or stand-alone operation.
We recommend that you read the Installation section of this manual and familiarize yourself with the procedures involved before starting to install luminaires. If you are not familiar with DMX, pay particular attention to the section on setting DMX addresses.
8
Cyclo IP65 Directional luminaires are supplied with the following items: • Osram T5 fluorescent tubes (installed) • Surface-mounting bracket.
• Two TET 5-7 Thorsman rubber membrane cable glands (installed) for data cable entry: cable diameter 5-7 mm (0.20-0.28 in.) • Two TET 10-14 Thorsman rubber membrane cable glands (installed) for power cable entry: cable diameter 10-14 mm (0.40-0.55 in.) • Two M25 metal blanking plugs (installed) for unused power cable entry holes.
• Two M16 metal blanking plugs (installed) for unused data cable entry holes.
• Two M25 metal IP68 cable glands (supplied loose) for AC power cable entry: cable diameter 7 - 15 mm (0.28 - 0.6 in.).
• Two M16 metal IP68 cable glands (supplied loose) for data cable entry: cable diameter 5 - 12 mm (0.2 - 0.45 in.).
Cyclo IP65 Directional user manual
Various operations described in this manual require access to the inside of the module that contains the tubes. To access the inside of the tube module: 1. Isolate the luminaire from power and ensure that power cannot be reconnected.
2. See Figure 1. Loosen the three front cover release screws in the hinged
front cover release flap until they turn freely.
Figure 1: Front cover release screws
the release flap (A) and then lift the hinged front cover (B). If you need to lever the release flap up, use a plastic or wooden object, as a metal object may damage the glass. Avoid damaging seals while you are working.
A B .
4. To close the front cover, first close the cover (B), then close the release
Figure 2: Opening the front cover
flap (A) so that it clips down over the cover. The seals on the inside faces of covers must be in perfect condition to maintain their waterproof qualities. Avoid damaging them. Any seal that is not in perfect condition must be replaced by a Martin service agent.
Installation
9
10
Various operations described in the is manual require access to the connections compartment in the base module. To access the connections compartment:
1. See Figure 3. Remove the two screws from the ends of the connections
compartment cover. A B
Figure 3: Opening the connections compartment cover
2. Open the hinged release flap (A) and then open the hinged cover (B). Avoid damaging the seal on the inside of the cover.
3. To close the connections compartment, first close the hinged cover (B), then close the release flap (A) so that it clips down over the cover. The seals on the inside faces of covers must be in perfect condition to maintain their waterproof qualities. Avoid damaging them. Any seal that is not in perfect condition must be replaced by a Martin service agent.
4. Tighten the two screws at either end of the cover before applying power.
Cyclo IP65 Directional user manual
1
DANGER! It is the installer’s responsibility to ensure that the installation is safe and that all local safety regulations and legal requirements are observed when mounting the Cyclo IP65 Directional.
The Cyclo IP65 Directional can be surface-mounted on a floor, wall or ceiling. To surface-mount the Cyclo IP65 Directional: 1. Ensure that the mounting surface is flat and can support the weight of all the devices to be installed on it. Allow 25 mm (1 inch) of free space around each luminaire.
2. Using the mounting bracket as a guide, mark up and drill holes in the mounting surface to take mounting fasteners.
3. Fasten the mounting bracket to the surface with at least two fasteners that have sufficient corrosion resistance and strength to mount the luminaire safely. Choice of mounting hardware will depend on the installation, but use high-quality corrosion-resistant fasteners with recommended minimum properties grade A4-70 (ISO 3506), or grade 8.8 (ISO 898-1). Any nuts used must be self-locking.
4. Check that the bracket is not distorted and is securely attached to the mounting surface.
2 C E D A B 5mm
Figure 4: Installing on the mounting bracket
5. See Figure 4. To install the luminaire on the mounting bracket, hook the
raised T-section (A) on the lower side of the luminaire base into the channel (B) on the mounting bracket, then swing the luminaire up so that
Installation
11
the T-section (C) on the upper side of the base passes behind the retaining rail (D).
6. Tighten the retaining screws (E) so that the retaining rail (D) grips the T section (C) tightly. Check that the luminaire is held securely.
Important! The Cyclo IP65 Directional support arms must both be fixed at the same angle. Do not twist the luminaire in the support arms, or you may deform the product and make it impossible to obtain a waterproof seal.
The Cyclo IP65 Directional can be installed in any orientation.
12
45° 30° 15° 90° 0° 15° 30° 45° 0° 45° 120° 60° 60°
Figure 5: Tilt angle adjustment
See Figure 5. The angle of the support arms can be adjusted in the base
module, and the tube module can be rotated in the support arms, allowing a wide range of tilt angles.
Cyclo IP65 Directional user manual
Adjusting the support arm angle
To adjust the angle of the support arms in the base module: 1. Ensure that the luminaire is securely mounted and isolated from power.
2. Open the connections compartment as described in “
Access to connections compartment
3. See Figure 6. Support the weight of the tube module. Loosen the arm
adjustment screws at both ends of the base module with a long Allen key, tilt the arms to the desired angle and retighten slowly, rocking the tube module up and down slightly while you tighten so that the adjustment screws engage correctly in the cutouts in the arm.
3mm
Figure 6: Arm-to-base adjustment screws
4. Reinstall the connections compartment cover as described in “
Access to connections compartment
Installation
13
Adjusting the tube module tilt angle
To rotate the tube module in the support arms: 1. Ensure that the luminaire is securely mounted and isolated from power.
1. Open the front cover as described in “
2. See Figure 7. Loosen both the tilt adjustment screws with a long Allen
key, rotate the tube module to the desired angle, and retighten.
3mm 3mm
Figure 7: Tube module tilt adjustment screws
3. Reinstall the front cover as described in “
14
Cyclo IP65 Directional user manual
Two types of seal can be used for cable entry: Thorsman rubber membrane cable glands
the base module and metal cable glands (see
with the product. If the metal glands are used, blanking plugs must be removed and replaced with metal glands.
Use the larger glands for power cable entry and the smaller glands for DMX data cable entry.
Cable glands may need to be replaced in the following situations:
Figure 8: Cable gland options
• If power or data cable is
used that is not within the diameters specified under “
” on page 8, new cable glands that match cable diameter must be obtained
from Martin or an electrical supplier.
• Rubber and metal glands must be replaced with new items if cable in an existing installation is replaced with cable of a different diameter.
• Used rubber membrane glands must be replaced with new unpierced items or replaced with blanking plugs if they are no longer used for cable entry.
• If metal cable glands are installed, they must be replaced with blanking plugs if no longer used for cable entry.
Replacement rubber membrane glands must have the following characteristics:
Temperature range . . . . . . . . . . . . . . . . . . . . -20° to +70°C or better Ingress protection rating . . . . . . . . . . . . . . . . . . . . . . . . IP67 or IP68 Installation plate thickness . . . . . . . . . . . . 0.5-4.0 mm (0.02-0.17 in.) Power cable gland installation hole diameter . . . . . . 23 mm (0.91 in.) Data cable gland installation hole diameter . . . . . . . 16 mm (0.63 in.)
Installation
15
Replacement metal glands must have the following characteristics:
Temperature range: . . . . . . . . . . . . . . . . . . . -20° to +70°C or better Ingress protection rating: . . . . . . . . . . . . . . . . . . . . . . . IP67 or IP68 Power cable gland thread size: . . . . . . . . . . . . . . . . . . . . . . . . . M25 Data cable gland thread size: . . . . . . . . . . . . . . . . . . . . . . . . . . M16 Minimum entry thread length: . . . . . . . . . . . . . . . . . 10 mm (0.4 in.)
I n s t a l l i n g c a b l e u s i n g r u b b e r m e m b r a n e g l a n d s
DANGER! Using a rubber membrane gland involves making a hole in the membrane. A used gland is therefore only waterproof with cable installed. If the cable is removed, the hole in the housing must be sealed with a blanking plug or new gland.
To install cable using a rubber gland:
Figure 9: Thorsman rubber membrane cable glands
1. Push a round spiked object through the center of the membrane from the outside of the housing just enough to pierce it. Do not enlarge the hole or remove rubber from the membrane.
2. Push cable through the gland from the outside of the housing.
I n s t a l l i n g c a b l e u s i n g m e t a l c a b l e g l a n d s
Two sizes of metal cable gland are supplied loose with the product. Use the larger glands for power cable entry and the smaller glands for DMX data cable entry.
To install cable using a metal cable gland: 1. Remove a blanking plug that matches the cable gland size from the base module housing.
16
Cyclo IP65 Directional user manual
2. See Figure 10. Dismantle the cable gland.
A B C D E
A – O-ring seal B – Cable entry C – Gland D – Washer E – Compression nut Figure 10 : Metal cable gland
3. Ensure that there is a rubber O-ring
A
on the housing end of the cable entry
B
, and screw this end into the threaded hole in the housing. Tighten until the O-ring
A
makes a water-resistant seal against the outer surface of the housing. Do not over-tighten, as this may damage the seal or housing.
4. Thread the cable through the compression nut
E
, washer
D
, gland
C
, and cable entry
B
into the housing.
5. Allow approx. 20 cm (8 in.) of cable slack inside the housing. Prevent the cable entry from turning and tighten the compression nut sufficiently to make a water-resistant seal. Do not over-tighten, as this may damage the gland. Check that the cable is firmly gripped in the rubber gland.
Installation
17
18 DANGER! It is the installer’s responsibility to ensure that all power cable and equipment is adequately dimensioned and of appropriate type for the installation, and that all local safety regulations and legal requirements are observed when installing and connecting the Cyclo IP65 Directional.
Current and power data are given in the Specifications section on page 43.
Inrush currents and electronic circuit-breakers
When fluorescent tubes with ECG (electronic control gear) systems are switched on at the AC wave peak, a larger current surge occurs than with conventional ballasts. If a large number of luminaires are switched on simultaneously, this inrush current can trip electronic circuit breakers. To avoid this in large installations, either switch on luminaires at intervals or limit the number of luminaires per 16 A electronic circuit breaker to approximately ten luminaires.
RCDs and common neutral conductors
Many fixed installations use common neutral conductors in branch circuit distribution boxes. To avoid unintentional tripping of the RCD (residual current device, or ground fault/earth leakage circuit breaker), ensure that each luminaire’s neutral conductor is connected to AC power via the same RCD as the live conductor.
Leakage to ground and RCDs
Each ECG “leaks” a total current of maximum 0.5 mA to ground (earth). Luminaires must be correctly connected to ground so that this “leakage” current can be absorbed.
Allow for the “leakage” current from ECGs when connecting luminaires to a circuit that has an RCD for ground fault protection, otherwise the RCD may trip unintentionally. Bear in mind that RCDs are rated at their
maximum
trip current, and that some RCDs rated 30 mA may trip when leakage to ground is as low as 20 mA.
RCDs can also be tripped by the inrush current when tubes are switched on.
To avoid unintentional tripping of RCDs: 1. Distribute power using 3 phases and install 3-phase RCDs.
2. If it is both safe and legal, use RCDs with a trip current rating higher than 30 mA. When considering this option, the installer must ensure that all local building and electrical regulations are respected. Maximum legally
Cyclo IP65 Directional user manual
permitted RCD trip current ratings are normally stated in national electrical and building codes.
3. Install surge current-resistant RCDs.
Connecting to power
A screw clamp is provided for connecting the luminaire to the power cable’s earth conductor, and a block of spring-loaded clamp terminals are provided for connecting the luminaire to the power cable’s live and neutral power conductors.Some common color-coding systems for power wiring are given below:
Wire (EU)
brown blue yellow/green
Wire (US)
black white green
Pin
live neutral ground
Marking on luminaire L1 N
Table 1: Power cable color-coding systems
To connect to AC power: 1. Ensure that power cannot be applied to the cable during installation.
2. Open the connections compartment as described in “
Access to connections compartment
3. Pass the power input cable through a cable gland as described in “
” on page 15 so that approximately 20 cm (8 in.) of cable is free
inside the luminaire, and prepare the end of the cable for connection.
4. See Figure 11. Four spring-loaded terminals marked
L1
,
L2
,
L3
and
N
and one screw clamp marked are provided for power cable connection. The terminals marked
L2
and
L3
are not used to supply power to the luminaire and are provided only to allow phase conductors to be connected if power is supplied from a 3-phase system (see
Connecting to a 3-phase system
Installation
19
20
5. Connect the conductors in the power input cable as follows: • Connect the ground (earth) wire to the screw terminal marked close to the power terminals.
• Connect the neutral wire to the spring-loaded power terminal marked
N
Power terminals DMX terminals
• Connect the live wire to the spring loaded power terminal marked
L1
.
Figure 11: Power and DMX connections
6. If power is to continue to another luminaire, pass power output cable
through a cable gland as described in “
prepare the end of the cable for connection. Each spring-loaded terminal has two holes. One hole now contains a conductor from the input cable and one is available for a conductor from the output cable. Using the spare holes, connect the conductors in the power output cable as
described under point 5. above.
C o n n e c t i n g t o a 3 - p h a s e s y s t e m
If you are supplying luminaires with power from a 3-phase system, the live conductor in the power input cable that you connect to terminal
L1
will be one of the phases. Connect one of the remaining phases to terminal
L2
and the last remaining phase to terminal
L3
. To distribute the load evenly over the 3 phases, connect phase 1 to terminal
L1
on one-third of the luminaires in the installation, phase 2 to terminal
L1
on one-third of the luminaires, and phase 3 to terminal
L1
on the remaining one-third of the luminaires. Terminals L2 and L3 do not supply power to the luminaire and are provided simply to allow phase conductors in separate lengths of power cable to be joined. To avoid confusion, each time you install a power output cable to take power to the next luminaire, connect each phase conductor in the power
output
cable to the terminal used for that phase conductor in the power
input
cable.
Cyclo IP65 Directional user manual
A f t e r m a k i n g p o w e r c o n n e c t i o n s
If you are installing DMX data cables, continue to the next section.
Otherwise, close the connections compartment as described in “
Access to connections compartment
Linking luminaires for DMX and
You need to create a data link to: • Control luminaires with a DMX control device.
• Operate two or more Cyclo IP65 Directionals in master/slave stand-alone mode, where all luminaires run a synchronized light show without a separate DMX control device.
A reliable data connection requires suitable cable. CAT 5 (category 5) UTP (unshielded twisted pair) network cable is suitable for this purpose. The minimum recommended wire size is 0.2 mm 2 (24 AWG) for runs up to 300 meters (1000 ft.) and 0.322 mm 2 (22 AWG) for runs up 500 meters (1640 ft). Your Martin Architectural supplier can advise and supply suitable cable.
Luminaires on a serial data link must be daisy-chained in one single line, maximum 500 meters (1640 ft.) long, with maximum 32 luminaires. To exceed 32 luminaires or 500 meters, or to add branches, an optically isolated amplifier-splitter such as the Martin RS-485 Opto-Splitter (P/N 90758060) must be used.
A male 3-pin XLR connector can be fitted at the controller end of the data link to allow a standard connection to Martin DMX controller. The XLR connector should be wired as follows: • Pin 1: shield • Pin 2: DMX - (cold) • Pin 3: DMX + (hot) To avoid ground (earth) loop interference, make sure that the DMX cable shield does not come into contact with the shell or body of the XLR connector.
A screw-type terminal block is provided in the connections compartment for connecting the data link. The data input and data output cables must both be connected to this terminal block. The data output may only be used to relay data to one luminaire.
Installation
21
Connecting to control data DMX controller Master Slave Slave
TIp!
120 Ohm resistor DMX control link 120 Ohm resistor Master/slave link
To create the data link: 1. If using a DMX control device, run suitable cable from the controller’s DMX output to the first luminaire on the link.
2. Use an M16 cable gland to run the data cable through the housing (see
4. Continue connecting up to 32 luminaires using the above procedure.
5. Terminate the data link by connecting a 120 Ohm, 0.25 W resistor across the + (hot) and - (cold) terminals of the last luminaire’s terminal block.
Random “flicker” and other unexplained control problems during stand-alone master/slave operation can often be cured by also connecting a 120 Ohm resistor across the + (hot) and - (cold) terminals of the first luminaire’s data connection terminal block.
22
Cyclo IP65 Directional user manual
Configuring luminaires for DMX or stand-alone operation
Each DMX model Cyclo IP65 Directional luminaire needs to be set up for DMX or stand-alone operation using the DIP switch located on the circuit board in the base module.
1 2 3 4 5 6 7 8 910
Figure 12: DIP switch
C o n f i g u r i n g f o r D M X o p e r a t i o n
DMX operation is enabled by setting pin 10 on the DIP switch to OFF. Pins 1 - 9 are then used to set the luminaire’s control address.
The Cyclo IP65 Directional uses one DMX channel to control each tube. The DMX address, also known as the start channel, is the first of these channels. It must be set on the luminaire (and selected on the DMX controller) before the controller can send commands to the luminaire via a data link. For example, a Cyclo 04 IP65 Directional with its DMX address set to 101 uses channels 101, 102, 103 and 104 to control its four tubes.
Allow enough channels when setting the DMX address.
If control channels for two luminaires overlap, one of the luminaires will receive the wrong commands.
If two or more Cyclo IP65 Directional luminaires share the same DMX address, they will receive the same commands and respond identically. Individual control will be impossible.
The default factory-set control address is ‘1’.
To set the Cyclo IP65 Directional’s DMX address: 1. Set DIP switch pin 10 to OFF.
Installation
23
2. Decide on a DMX address for the luminaire. If you are calculating the DMX addresses for multiple luminaires, save time by using the online Martin Address Calculator at http://www.martin.dk/service/utilities/AddrCalc/index.asp (see illustration below). 3. You can also look up DIP switch settings using the Martin DIP Switch Calculator, available for use and downloadable at http://www.martin.dk/service/dipswitchpopup.htm
If you do not have Internet access, refer to
"Table 2: DMX address DIP switch settings
4. Set DIP switch pins 1 through 9 to ON (1) or OFF (0) with reference to the table.
To use this table, first find the DMX address in the main block in the table. Then read the settings for pins 1 - 5 to the left and read the settings for pins 6 - 9 above the address. “0” means OFF and “1” means ON.
For example, to set the DMX address to 101, you need to set DIP switch pins 1, 3, 6 and 7 to ON, as highlighted in the table.
DIP switch pins setting 0 = OFF 1 = ON
#9 #8 #7 #6 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 1 0 0 1 0
0 0 1 1
0 1 0 0 0 1 0 1 0 1 1 0 0 1 1 1 1 0 0 0 1 0 0 1 1 0 1 0 1 0 1 1 1 1 0 0 1 1 0 1 1 1 1 0 1 2 3 4 5 6 7 8 9 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 37 69
101
133 165 197 229 261 293 325 357 389 421 453 485 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511 1 1 1 1
Table 2: DMX address DIP switch settings
Installation
25
C o n f i g u r i n g f o r s t a n d - a l o n e o p e r a t i o n
Stand-alone operation is enabled by setting pin 10 on the DIP switch to ON and pin 8 to OFF. The other pins are then used to program the luminaire.
Stand-alone operation settings
” on page 30 for details of how to set
these pins.
After making connections
After you have finished making power and data connections, make sure that any holes not used for cable entry are sealed either with blanking plugs or unpierced membrane cable glands, then close the connections
Access to connections compartment
” on page 10 before applying power.
26
Cyclo IP65 Directional user manual
Operation: general
” on page 3 before operating this
product!
Fluorescent tube lifetimes and
The Osram high output T5 tubes fitted as standard meet color specifications for at least 10 000 hours. Average tube life is 20 000 hours, but note that tube life will vary depending on operating conditions.
Each power off/on cycle reduces tube life by approximately 30 minutes. To optimize tube life when controlling via DMX, do not dim tubes below DMX value 3 (i.e. approximately 1%) when they are not required in the color mix. To optimize tube life in stand-alone mode, program color-changing cycles that run as slowly as possible. For more detailed information on maximizing tube lifetimes, see the Martin website at http://www.martin.com/service.
Achieve optimum tube performance by ‘burning in’ new fluorescent tubes, i.e. running them for 100 hours at full power.
Excess humidity inside the luminaire can be experienced if: • Seals are affected because covers are distorted or not correctly fastened • Cable glands are not correctly assembled and tightened • Cable diameters are not correct for cable glands • Blanking plugs are not correctly fitted and tightened • Cables open into damp or wet locations (e.g. poorly sealed junction boxes), which will encourage moisture to pass along the cable into the luminaire.
The Cyclo IP65 Directional is fitted with a self-purging valve that gradually expels moisture as the luminaire heats up and cools down in normal use. To eliminate condensation rapidly (after installation, for example), run the luminaire at full operating temperature in dry weather conditions for a minute
Operation: general
27
or two with the front cover removed so that air circulates, then refit the front cover while the luminaire is hot. If you do this: • The exposed internal components present a risk:, so block public access.
• Ensure that no dust or objects enter the luminaire while it is open.
Operation in extreme ambient
Do not operate the Cyclo IP65 Directional if the ambient temperature exceeds 40° C.
Cyclo IP65 Directional luminaires can be operated in ambient temperatures as low as -20° C (-4° F), but a combination of low temperature and low dimming level will give a risk of flickering and cause voltage across tubes to rise. In extreme cases, luminaires will shut down power to tubes to avoid damage to components. If this happens, luminaires must be reset by powering them off and on again before tubes can be restarted.
Flickering can be avoided at ambient temperatures below freezing point if luminaires are operated so that they generate their own heat and maintain tube temperature at or above freezing point. For best low-temperature dimming performance: • As soon as the ambient temperature falls below 0° C (32° F), apply power permanently to luminaires. If light output is not required, reduce output by dimming tubes instead of shutting down power completely.
• If flickering occurs when dimming, increase the minimum dimming level.
• If flickering occurs when dimming luminaires after startup, start luminaires at full power for several minutes.
As a general rule, the higher the light output, the lower the ambient temperature luminaires can tolerate.
28
Cyclo IP65 Directional user manual
Stand-alone operation
” on page 3 before attempting to
operate this product!
In stand-alone operation, the Cyclo IP65 Directional can run light shows without a DMX controller. Luminaires can be programmed to change colors in cycles. Changes can be programmed at 1, 5, 10 or 30 second intervals.
Two stand-alone operation modes are available: • In
single stand-alone operation
, luminaires run independently of each other. No data link is required.
• In
master/slave stand-alone operation
, luminaires must be linked with a
Linking luminaires for DMX and synchronized operation
” on page 21 explains how to install this link). Synchronized action in all
luminaires is triggered by one “master” luminaire. In both single and master/slave stand-alone operation, luminaires are programmed by setting the pins on the DIP switch on the circuit board as shown in the following table. 7 8 9 10
Pin
1 2 3 4 5 & 6
Function
White active (04 models), red active (03 models) Red active (04 models), green active (03 models Green active (04 models), blue active (03 models) Blue active (04 models)
Program speed Pin 6
OFF OFF ON
Pin 5
OFF ON OFF ON ON OFF = Blackout fading, ON = Crossfading
Speed
1 sec. steps (fastest setting) 5 sec. steps 10 sec. steps 30 sec. steps (slowest setting) OFF = Run program, ON = Deactivate program (Note: always set to OFF) OFF = Master, ON = Slave (Note: do not set more than one luminaire as master) ON = Stand-alone mode.
Table 3. Stand-alone DIP switch settings
Stand-alone operation
29
A quick reference table covering DIP switch functions is also provided on the back cover of this manual.
30
Activating tubes
DIP switch pins 1 to 3 (03 models) or 1 to 4 (04 models) activate tubes in the stand-alone program.
Setting program speed
Combinations of DIP switch pins 5 and 6 allow one of four different speeds to be set.
Note that the speed of color changes affects tube life (see “
Fluorescent tube lifetimes and performance
Fading between colors
If DIP switch pin 7 is set to OFF (blackout fading), colors fade to almost blackout before the next color fades in.
If DIP switch pin 7 is set to ON (crossfading), color fading overlaps. If two or more colors are active, one color fades in while another is fading out, giving a color mixing effect. For example, if red and blue are activated and crossfading is selected, colors will crossfade from red through purple to blue, then back through purple to red in a continuous cycle (see example).
100%
Red
50% Red 50% Blue 50% 0%
Blue Time Purple Red
Example: crossfading between red and blue
Cyclo IP65 Directional user manual
In single stand-alone operation, a luminaire runs its own program independently of all other luminaires. To do this, the luminaire must be set as a master.
Activating single stand-alone operation
To activate single stand-alone operation: 1. Set DIP switch pin 10 to ON (switches from DMX to stand-alone mode).
2. Set DIP switch pin 9 to OFF (activates master mode).
3. Set DIP switch pin 8 to OFF (activates stand-alone mode)
4. Program the luminaire using DIP switch pins 1 - 7 (see table on page 29).
Important!
Do not set more than one luminaire on a data link as master, and do not set a luminaire as master on a data link with a DMX controller. Doing so may cause damage to the electronics that is not covered by the product warranty.
In master/slave stand-alone operation, one master luminaire transmits a synchronizing signal to slave luminaires over the data link each time it starts a new action. Slave luminaires start their next programmed action when they receive this signal from the master luminaire. Programs can be identical on all luminaires, or luminaires can – subject to certain practical constraints – run programs that are synchronized but not identical.
Note that each luminaire follows the program set on its own DIP switch as
described in the table on page 29.
Note also that colors are always displayed in the order: white → red → green → blue.
This means for example that if white is activated, it will always be first in the program. If white is not activated but red is activated, red will be first in the program.
More sophisticated light shows can be programmed using a DMX controller
The synchronization signal used by the Cyclo IP65 Directional is identical to that used in other Cyclo luminaires with the same number of tubes, allowing these products to be combined in master/slave operation on one data link. However, Cyclos with different numbers of tubes cannot be mixed in master-
Stand-alone operation
31
32
slave operation. Consult your Martin Architectural supplier if you need advice on combining and controlling products.
Identical light shows
Master and slave luminaires can be set to behave identically. In this mode, the master sends synchronizing signals to the slaves, and all luminaires run the same light show. Each slave luminaire follows the program set on its own DIP switch, so for identical operation, all luminaires’ DIP switch settings must be the same apart from pin 9, which is set to ON for slaves and OFF for the master.
Synchronized non-identical light shows
It is also possible to synchronize changes but program slave luminaires to behave differently from the master. To use this feature effectively, you need to plan your light show using
scenes
as building blocks and set the luminaires’ DIP switches accordingly.
A scene is a change from one output to another. When a luminaire is in slave mode, it starts a scene when it receives a synchronization signal from the master. The time taken by the scene is determined by the speed setting of the DIP switch. A slave will not respond to new synchronization signals until its scene is complete.
When crossfading is selected, each color takes up one scene (fade in only). When blackout fading is selected, each color takes up two scenes (fade in and fade out). This means that the maximum number of scenes that can be programmed is twice the number of tubes installed, with all tubes activated and blackout fading selected.
Each time the master luminaire starts at scene 1, it sends a signal to all the slave luminaires to start at scene 1. This means that if a slave luminaire has: 1. Fewer scenes than the master luminaire, it will run these in a cycle until the master luminaire signals that the program should start from the beginning again.
2. More scenes than the master, the additional scenes will never run, because the program will reset to the first scene when the master starts its program from the beginning.
Here is an example of what will happen when a slave luminaire has fewer scenes than the master luminaire:
Luminaire setting
Master with 6 scenes Slave with 4 scenes
Scene pattern
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 . . .
1 2 3 4 1 2 1 2 3 4 1 2 1 2 3 4 1 2 . . .
Cyclo IP65 Directional user manual
Program examples
The following examples of programs show how an individual luminaire’s program is made up of scenes.
The following symbols are used in program diagrams: Tube turned fully off Fade in Fade out Fade to 50% and back to 100% in one scene (applies when only one color is active and crossfading is selected)
Example 1
DIP switch 7 is set to ON (crossfading) and only red is activated: Red Scene 1 1 1 1 1 1 1 1 1 1 1 1
Example 2
DIP switch 7 is set to OFF (blackout fading) and only red is activated: Red Scene 1 2 1 2 1 2 1 2 1 2 1 2
Example 3
DIP switch 7 is set to ON (crossfading) and red and blue are activated: Red Blue Scene 1 2 1 2 1 2 1 2 1 2 1 2
Stand-alone operation
33
Example 4
DIP switch 7 is set to OFF (blackout fading) and red and blue are activated: Red Blue Scene 1 2 3 4 1 2 3 4 1 2 3 4
Example 5
To achieve a rainbow effect, activate red, green and blue tubes and set DIP switch pin 7 to ON (crossfading).
Red Green Blue Scene 1 2 3 1 2 3 1 2 3 1 2 3
Activating master/slave stand-alone operation
To activate master/slave stand-alone operation: 1. Isolate all luminaires from power.
2. Set all luminaires as slaves and enable stand-alone mode by setting DIP switch pins 9 and 10 to ON and pin 8 to OFF.
3. Decide which luminaire to use as master and set this luminaire’s DIP switch pin 9 to OFF. Note that any luminaire can be set as master, but you will obtain the most reliable data signal by either setting the first luminaire on the link as master or using 120 Ohm resistors to terminate
both
ends.
4. When power is applied, slave luminaires will go to the next scene in their program each time the master goes to its next scene. Slave luminaires will also start scene 1 of their programs each time the master starts scene 1 of its program.
34
Cyclo IP65 Directional user manual
DMX-controlled operation
” on page 3 before attempting to
operate this product!
Cyclo IP65 Directional DMX models may be operated with any lighting control device that is compatible with the USITT DMX (1990) standard. For details of connecting luminaires on a data link to a DMX controller, see
Linking luminaires for DMX and synchronized operation
For details of setting up luminaires for DMX control, see “
Configuring luminaires for DMX or stand-alone operation
The Cyclo IP65 Directional’s advanced fluorescent tubes can be dimmed from maximum output right down to zero using one channel per tube on a DMX controller. This allows a wide range of color shades with variable intensity to be obtained using additive color mixing. On 04 models the color temperature of white light can also be fine-tuned.
Depending on the functions available on the controller, sophisticated light shows on the Cyclo IP65 Directional can be programmed over time, allowing constantly and rapidly shifting color mixes, or color displays which change slowly according to the time of day, or even year, for example. See the controller’s manual for details.
Your Martin Architectural supplier can advise about available controllers and control options.
DMX-controlled operation
35
Service
” on page 3 before attempting to
service this product!
With long-life fluorescent tubes and no moving parts, the Cyclo IP65 Directional is almost service-free, but this section describes the minimum of periodic maintenance required.
Refer any service operation not described in this manual to an authorized Martin service agent.
Use a damp cloth or soft brush soaked in a solution of water and a mild detergent cleaner such as auto shampoo to clean luminaires. Do not use abrasive, acidic or caustic cleaning products, or you will damage the luminaires’ anodized finish.
Do not use a high pressure water-jet for cleaning: IP65 luminaires are protected against water projections and low-pressure water jets only.
To replace the tubes in the Cyclo IP65 Directional: 1. Isolate the luminaire from power and ensure that power cannot be reapplied, even accidentally.
2. Loosen the front cover release screws, lift up the release flap and open
the front cover as described in “
36
Cyclo IP65 Directional user manual
the reflector by lifting it out of the tube module housing.
4. In 04 models, remove the white tube by holding the metal caps at both ends of the tube,
Figure 13: Removing the reflector
rotating the tube approx. 1/4 turn in either direction, and sliding the tube’s terminal pins out of their sockets. Support the tube at both ends as it is released.
5. See Figure 14. To release the diffuser, push the locking bars from
position B in towards the center of the luminaire until they are in position A. Lift the diffuser out of the luminaire.
Figure 14: Removing the diffuser
6. The red, green and blue tubes are installed close together. To remove, press with one finger on the metal caps at both ends of each tube and rotate to release from the sockets.
7. When installing new tubes, line them up so that the manufacturer’s markings on all tubes are at the same end of the luminaire. Tube positions are labelled
R
for red,
G
for green and
B
for blue. Slide each tube’s terminal pins fully into their sockets and rotate the tube approx. 1/4 turn in either direction to engage the pins. Check that tubes are held securely.
8. Reinstall the diffuser, reflector, white tube (in 04 models) and front cover before reapplying power.
Tube positions
The burning positions of fluorescent tubes affect their warm-up times, operating temperature, light output and tube life. For optimum results: • Install tubes so that the manufacturer’s markings are all at the same end of the luminaire.
• If the luminaire is installed in a vertical position or at an angle from the horizontal, locate the ends of the tubes that carry the manufacturer’s markings at the lower end of the luminaire. However, in a cold environment, i.e. where temperatures are generally around or below freezing point, locate the markings at the
upper
end of the luminaire).
The main fuse is located on the PCB in the ballast tray. See page 43 in
the Specifications section for details of fuse types and ratings. Never replace a fuse with one of a different type or rating.
Figure 15: Removing the PCB
To replace the fuse: 1. Isolate the luminaire from power and ensure that power cannot be reapplied accidentally.
2. Open the connections compartment cover as described in “
Access to connections compartment
3. See Figure 15. Undo the two retaining screws from the ballast tray
and slide the tray out of the housing.
4. See Figure 16. Replace the main fuse on the PCB with one of the
same type and rating.
Main fuse Figure 16: Main fuse
5. Reinstall all covers before reapplying power.
If a fuse blows repeatedly, refer to your Martin Architectural supplier for service.
See Figure 16. The voltage switch on the PCB is factory-set to match
100-120 or 200-240 V nominal AC power at 50 or 60 Hz.
Important! Do not change the voltage setting without first consulting your Martin Architectural supplier.
Troubleshooting
Problem
No response from luminaire when power is applied.
Probable cause(s)
No power to luminaire.
Remedy
Check power connections. Ground fault protection circuit breaker (RCD) has tripped.
Reset RCD. If problem persists, have an electrician replace the RCD or reduce the number of luminaires powered via one RCD.
If running in stand-alone mode, DIP switch pin 8 is set to ON.
Controller not connected.
Set DIP switch pin 8 to OFF to allow stand-alone operation. Incorrect DMX addressing.
Check DMX data link. Inspect connections and test cables. Repair or replace as necessary.
Check address setting on luminaire and controller.
Luminaires do not respond correctly to DMX control.
Data link not terminated.
Two devices transmitting on link.
Connect 120 Ohm termination resistor across data link + (hot) and - (cold) in parallel with last luminaire on link.
Check that all luminaires are set as slaves (DIP switch pin 9 ON).
Luminaires do not behave correctly in master/slave mode Defective luminaire.
Two luminaires transmitting on link.
Check that only one luminaire is set to operate as master.
Defective luminaire.
Bypass luminaires one at a time until normal operation is regained to identify faulty luminaire.
Have faulty luminaire tested and repaired by Martin service technician.
Bypass luminaires one at a time until normal operation is regained to identify faulty luminaire.
Have faulty luminaire tested and repaired by Martin service technician.
Tube or tubes not burnt in.
Poor quality light output and/or color rendering.
Tube defective.
Run tubes at 100% intensity for 100 hours to burn in. Disconnect luminaire and replace tube.
Table 4: Troubleshooting
DMX protocols
Cyclo 04 IP65 Directional
Channel 1 2 3 4 Value
0-2 3-252 253-255 0-2 3-252 253-255 0-2 3-252 253-255 0-2 3-252 253-255
Percent
0 1 - 99 100 0 1 - 99 100 0 1 - 99 100 0 1 - 99 100
Function White intensity
Tube off Intensity 1 → 100% Intensity 100%
Red intensity
Tube off Intensity 1 → 100% Intensity 100%
Green intensity
Tube off Intensity 1 → 100% Intensity 100%
Blue intensity
Tube off Intensity 1 → 100% Intensity 100%
Table 5: DMX protocol, Cyclo 04 IP65 Directional Cyclo 03 IP65 Directional
Channel 1 2 3 Value
0-2 3-252 253-255 0-2 3-252 253-255 0-2 3-252 253-255
Percent
0 1 - 99 100 0 1 - 99 100 0 1 - 99 100
Function Red intensity
Tube off Intensity 1 → 100% Intensity 100%
Green intensity
Tube off Intensity 1 → 100% Intensity 100%
Blue intensity
Tube off Intensity 1 → 100% Intensity 100%
Table 6: DMX protocol, Cyclo 03 IP65 Directional
Cyclo IP65 Directional specifications
Physical
L x W x H . . . . . . . . . . . . . . . . . 1257 x 149 x 230 mm (49.5 x 5.9 x 9.1 in.) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 kg (48.5 lbs)
Lamp
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T5 fluorescent tubes Approved lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Osram FQ 54 W HO Average tube life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 000 hours Socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G5
Dynamic effects
Color mixing . . . . . . . . . . . . . . . . . . .RGB (03 models) RGBW (04 models) Red. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 100% Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 100% Blue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 100% Cool white (4000 K) . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 100% (04 models)
Control and programming
Control options . . . . . . . . . DMX, stand-alone, synchronized (master/slave) Number of DMX channels . . . . . . . . . . . . . . .3 (03 models), 4 (04 models) DMX address setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIP switch Stand-alone and master/slave programming . . . . . . . . . . . . . . . DIP switch Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USITT DMX512/1990 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485
Construction
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum and stainless steel Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clear anodized Front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Toughened glass Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . High specular 99.9% aluminum Protection factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
Installation
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Any Minimum free space around luminaire . . . . . . . . . . . . . . . .25 mm (1 inch)
Connections
Power cable entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP68 cable gland Power connection. . . . . . . . . . . . . . . . . . . . . . . . Quick connector terminals Data cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP68 cable gland Data connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw terminals
Electrical
AC power . . . . . . . . . . . . . . . . . . . . 100-120/200-240 V nominal, 50/60 Hz Main fuse, 03, 120 V model . . . . . . . . . . . . . . . . . . . . . . . 2 AT (slow blow) Main fuse, 04, 120 V model . . . . . . . . . . . . . . . . . . . . . . 2.5 AT (slow blow) Main fuse, 03, 230 V model . . . . . . . . . . . . . . . . . . . . . . . 1 AT (slow blow) Main fuse, 04, 230 V model . . . . . . . . . . . . . . . . . . . . . . . 2 AT (slow blow)
Typical power and current
Cyclo IP65 03 Directional, 120 V model
100 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 W, 1.6 A 120 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 W, 1.5 A
Cyclo IP65 03 Directional, 230 V model
208 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 W, 0.9 A 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 W, 0.8 A 240 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 W, 0.8 A
Cyclo IP65 04 Directional, 120 V model
100 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 W, 2.2 A 120 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 W, 2.0 A
Cyclo IP65 04 Directional, 230 V model
208 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 W, 1.2 A 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 W, 1.1 A 240 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 W, 1.0 A
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Thermal
Maximum ambient temperature (T a ). . . . . . . . . . . . . . . . . . . 40° C (104° F) Minimum ambient temperature (starting from and dimming at 1% output possible when permanently powered). . . . . . -20°C (-4°F) Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Convection
Total heat dissipation (calculated, +/- 10%):. . . . . 615 BTU/hr. (03 models) . . . . . . . . 805 BTU/hr. (04 models)
Approvals
US Safety . . . . . . . . . . . . . . . . . . . . . . UL 1573 Canadian Safety . . . . . . . . CSA C22.2 No. 166 European safety . . . EN 60598-1, EN 60598-2 European EMC . . . . . . EN 60555-3. EN 55015
Included items
Osram FQ 54 W/60 HO red T5 tube Osram FQ 54 W/66 HO green T5 tube Osram FQ 54 W/67 HO blue T5 tube Osram FQ 54 W/840 HO cool daylight white (4000 K) T5 tube (04 models) Two M25 cable glands, IP68, metal, cable Ø 7 - 15 mm (0.28 - 0.6 in.) Two M16 cable glands, IP68, metal, cable Ø 5 - 12 mm (0.2 - 0.45 in.) M25 blanking plug, metal M16 blanking plug, metal Surface-mounting bracket User manual
Accessories
DMX termination resistor, 120 Ohm . . . . . . . . . . . . . . . . . . . P/N 04150308 Osram T5 FQ 54 W/827 HO 2700 K warm white tube (04 model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 97020009 Osram T5 FQ 54 W/865 HO 6500 K daylight white tube (04 model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 97020011
Spare parts
Osram T5 FQ 54 W/60 HO red tube . . . . . . . . . . . . . . . . . . P/N 97020006 Osram T5 FQ 54 W/66 HO green tube . . . . . . . . . . . . . . . . P/N 97020007 Osram T5 FQ 54 W/67 HO blue tube. . . . . . . . . . . . . . . . . . P/N 97020008 Osram T5 FQ 54 W/840 HO 4000 K cool white tube (04 model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 97020010
Ordering information
Cyclo IP65 03 Directional, 54 W tubes, 120 V . . . . . . . . . . . P/N 90566810 Cyclo IP65 03 Directional, 54 W tubes, 230 V . . . . . . . . . . . P/N 90566010 Cyclo IP65 04 Directional, 54 W tubes, 120 V . . . . . . . . . . . P/N 90567810 Cyclo IP65 04 Directional, 54 W tubes, 230 V . . . . . . . . . . . P/N 90567010
Specifications subject to change without notice.
Disposing of this product
Martin Architectural ® products are supplied in compliance with Directive 2002/96/EC of the European Parliament and of the Council of the European Union on WEEE (Waste Electrical and Electronic Equipment), as amended by Directive 2003/108/EC, where applicable.
Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin ® products.
3. Tube 3 2. Tube 2 1. Tube 1 8. ON = Deactivate stand-alone OFF = Activate stand-alone 9. ON = Stand-alone slave OFF = Stand-alone master/single 10. ON = Stand-alone OFF = DMX
1 2 3 4 5 6 7 8 910
4. Tube 4 (04 models) 7. ON = Crossfading OFF = Blackout fading 5/6. Program speed
Quick reference Cyclo IP65 Directional stand-alone operation DIP switch settings
www.martin-architectural.com • Olof Palmes Allé 18 Tel: +45 8740 0000 • • 8200 Aarhus N Fax +45 8740 0010 • Denmark