advertisement
▼
Scroll to page 2
of 24
500 Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. TION A M R O T INF N A T R O USE IMP E R O F E ONS! I T C READ B U R NST I E S E H VE T A S E S A PLE April 2010 500 Series Display Cases Service and Installation Manual Contents RECEIVING & INSPECTING EQUIPMENT...............................2 SPECIFICATIONS...................................................................3 PRESSURE CONTROL SETTINGS..........................................5 INSTALLATION.................................................................. 5, 6 OPERATION...................................................................... 5, 6 CARE & CLEANING...............................................................6 WIRING DIAGRAMS 500-CR self-contained refrigerated units........................7 500-OR open refrigerated units......................................7 500-CD dry storage units...............................................8 500-CH curved heated units...........................................8 EXPLODED VIEWS & PARTS LISTS 537-CD...........................................................................9 549-CD...........................................................................9 561-CD.........................................................................10 573-CD.........................................................................10 537-CR, CRR................................................................11 549-CR, CRR................................................................11 561-CR, CRR................................................................12 573-CR, CRR................................................................12 549-CH.........................................................................13 561-CH.........................................................................13 573-CH.........................................................................14 549-OR.........................................................................14 FLUORESCENT LIGHT ASSEMBLY......................................15 DOOR ASSEMBLY................................................................16 REFRIGERATION ASSEMBLES............................................17 FOOD WELL ASSEMBLY......................................................18 REPLACEMENT PARTS LIST...............................................19 STANDARD LABOR GUIDELINES.........................................20 STANDARD WARRANTIES............................................. 21-22 NOTES.................................................................................23 Serial Number Location The Serial number on all 500 Series units is located on the rear of the unit, near the ON/OFF switch. Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots can be found at www.delfield.com. ©2010 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. “Delfield” is a registered trademark of The Delfield Company. Receiving and Inspecting the Equipment Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building. 1. 2. 3. 4. 5. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately. If damaged, open and inspect the contents with the carrier. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment. Check the lower portion of the unit to be sure adjustable feet are not bent. 6. 7. 8. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact. Freight carriers can supply the necessary damage forms upon request. Retain all crating material until an inspection has been made or waived. Uncrating the Equipment First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual 500 Series Specifications MODEL NUMBER DELFIELD PART # VOLTS/HERTZ PHASE Dry Storage Display Cases 537-CD 078-5371 549-CD 078-5491 561-CD 078-5611 573-CD 078-5731 MODEL NUMBER DELFIELD PART # 115/60/1 115/60/1 115/60/1 115/60/1 VOLTS/HERTZ PHASE AMPS 3 4 5 120, 208-240V/60/1 120, 208-240V/60/1 120, 208-240V/60/1 19.0/21.0 24.0/27.0 30.0/34.0 DELFIELD PART # H.P.* Remote Refrigerated Display Cases 537-CRR CONSULT FACTORY 549-CRR 078-5493 561-CRR 078-5613 573-CRR 078-5733 *Recommended horsepower MODEL NUMBER 1/2* 1/2* 3/4* 3/4* DELFIELD PART # H.P. Self-Contained Refrigerated Display Cases 537-CR 078-5372 549-CR 078-5492 561-CR 078-5612 573-CR 078-5732 MODEL NUMBER 1/2 1/2 3/4 3/4 DELFIELD PART# H.P. Open Front Refrigerated Display Cases 549-OR 078-5495 5.0 5.0 5.0 5.0 NUMBER OF 12 X 20 WELLS Heated Display Cases 549-CH 078-5494 561-CH 078-5614 573-CH 078-5734 MODEL NUMBER AMPS (includes lights & fan) 1/2 VOLTS/HERTZ PHASE AMPS 115/60/1 115/60/1 115/60/1 115/60/1 12.0 12.0 16.0 16.0 VOLTS/HERTZ PHASE AMPS 115/60/1 CABINET LOAD BTU/HOUR 180 190 190 290 1730 2250 2770 3290 5.0 5.0 6.0 6.0 VOLTS/HERTZ PHASE AMPS 115/60/1 115/60/1 115/60/1 115/60/1 EVAPORATOR CAPACITY BTU/°TD 12.0 CABINET LOAD BTU/HOUR SYSTEM CAPACITY BTU/HOUR REFRIGERATION CHARGE 404A 1730 2250 2770 3290 3258 3316 4919 5387 32 oz. 32 oz. 48 oz. 48 oz. CABINET LOAD BTU/HOUR SYSTEM CAPACITY BTU/HOUR REFRIGERATION CHARGE 404A 2030 3354 32 oz. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Installation: 500 CD, CR, CRR & OR Location To meet NSF standards, all units must be sealed to the floor. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. Contents fully loaded in this product line can weigh as much as 1500 lbs. Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out. Do not pack the refrigerator so full that air cannot circulate. Be sure that the exterior of the unit has access to ample air. Avoid hot corners and locations near stoves and ovens. Leveling To level unit, simply lower the four adjustable rubber feet located under the unit to the floor and adjust until unit is level. A level cabinet will perform better because the drain will empty properly, the doors will line up with the frames correctly and the cabinet will not be subject to undue strain. Plumbing Self-contained models are standard with a condensate evaporator. If the evaporator fails, the unit’s drain must have an outlet to an appropriate drainage area or container. Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner’s and CAUTION operator’s responsibility to provide a container or outlet for drainage. Electrical connection Refer to the amperage data on page 3, the serial tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord, or permanent connection to the unit. Self-contained units have an ON/OFF switch located on the operators side. Simply turn the switch to ON to begin operation. The power switch should be turned to OFF and the unit disconnected from the power source whenever performing service or maintenance functions. Operation: 500 CD, CR, CRR & OR On self-contained models, after turning the ON/OFF switch to ON, the unit’s compressor will begin operating. Delfield display cases are designed to maintain an operational temperature of 36°F to 40°F. Do not load the storage area in a way that restricts the air flow. Overloading will result in the loss of temperature. Do not throw items into the storage area. The interior of the cabinet and the blower coil may be damaged by this type of neglect, which is not covered under your warranty. These units use HFC-404A refrigerant, and have a lock-out high pressure limiting device. Under severe overloading conditions, in the event of a condenser fan failure or a plugged or blocked condenser, this device may shut down the refrigeration system. See page 17 for part number information if a replacement is required. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Control Settings: 500 CR & OR Pressure Control The temperature is controlled by an adjustable pressure control located in the machine compartment. An adjustable control has the word COLDER near the knob, with an arrow to indicate the adjustment direction. These controls are field adjustable and do not require a service agent. If you have any questions, feel free to contact the Delfield Service Department. The refrigeration systems on self-contained CR & OR models were adjusted at the factory to maintain between 36°F and 40°F. No adjustment should be necessary. If adjustment does become needed however, the factory recommended settings are: Low-pressure settings (CR models): 82 psi cut-in, 47 psi cut-out, 35 psi differential. Low-pressure settings (OR models): 82 psi cut-in, 40 psi cut-out, 42 psi differential. Operating pressures: High, 170 to 200 psi. Low, 30 to 37 psi. In attempting to adjust the pressure control, you can do damage to your unit by accidentally adjusting the differential. Please make small incremental adjustments if a temperature adjustment is necessary, please contact the service department at Delfield (800) 733-8829 #1, or your local service agent. Delfield is not responsible for charges incurred while having the pressure control adjusted. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Installation: 500 CH Installation should be done by personnel certified and licensed to install and maintain electrical appliances. Location Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. Contents fully loaded into this product line can weigh as much as 1500 lbs. Reinforce the floor as necessary to provide for maximum loading. Leveling A level cabinet looks better and will perform better because the drain pan will drain properly, the doors will line up with the frames properly, and the cabinet will not be subject to undue strain. Electrical connection Connections must be made in accordance with all applicable local codes and/or the National Electrical Code. Refer to the wiring diagrams on pages 6 and 7. Operation: 500 CH NOTE: Intended for DRY OPERATION ONLY. Before the unit is used the first time for serving, turn the temperature knob to “10” and heat the well for 20 minutes. Do not be alarmed if smoke appears; this preheat should burn off any residue or dust on the heating element. Hot surfaces can cause serious burns. Always wear some type of protective covering on your hands and arms when removing lids or pans from the unit. Never place food directly into the well. Always use pans. Always place covers on pans when not serving to prevent food from drying out and to reduce your operating cost. For most efficient operation, keep covered insets empty in each well during preheating and when the well is not in use. Dry operation STEPS 1)Pre-heat the well on “HIGH” for approximately 15 minutes. 2) After pre-heating, set the control to your desired serving temperature. Only 6” (15.2cm) deep insets should be used with a dry food well. When operated dry, the bottom of the food well will discolor. Refer to cleaning instructions to remove discoloration. Temperature Product in pans . . . . . . . . . . . . . . . . . . . . . . 140°F to 160°F Cleaning: All Models Clean the food wells daily. Wash with non-abrasive cleanser and non-abrasive pad. If necessary, a mild abrasive may be used. Do not use steel wool. For all stainless steel parts, use mild, non-abrasive soap or detergent and warm water. This may be followed by an application of stainless steel cleaner or polish which will eliminate water spotting and fingerprints and will bring out the finish of the stainless steel. Do not use a hose or pressure wash on these units. The water will damage the electrical components. Cleaning the condenser (refrigerated units) In order to maintain proper refrigeration, the condenser fins must be cleaned of dust, dirt and grease every three months. If condenser is totally blocked after three months increase cleaning frequency. Clean the condenser with a vacuum cleaner or stiff brush. If extremely dirty, use a commercially available condenser cleaner. Cleaning the sliding door assembly All Delfield 500 Series display cases feature a Pike sliding door assembly. Regular cleaning of door tracks with mild soap and water will keep them free of foreign matter insuring many years of use. The glass may be cleaned with a glass cleaner. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Wiring: 500 CR Wiring: 500 OR NEUTRAL NEUTRAL For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Wiring: 500 CD Wiring: 500 CH RED 2 1 L H 1 H 2 2 P L 120V 1 L H 1 H 2 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com WHT BLK WHT BLK WHT BLK WHT 2 H 2 HEATED SHELF BLK RED WHT WHT WHT P L 208V P WHT L H 1 H 2 RED 1 RED P L 208V BLK H 1 2 P WHT WHT L RED 1 BLK P L BLK P WHT WHT P WHT BLK BLK BLK 208V RED WHT RED BLK BLK BLK J 500 Series Display Cases Service and Installation Manual Replacement Parts List For 537-CD KEY Quantity 9 11 10 2 4 6 7 3 13 12 6 DELFIELD PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 001-5285 diffuser, air 537-CD/CR 6 2 XMK00127 fixture, flour. light, 24 remote 7 4 001-5407 support, shelf, 537-CD/CR 8 2 001-5026 clip, air diffuser, 537-CD 9 1 397-8137 shelf, adjustable, 21” x 33” 10 1 397-8138 shelf, adjustable, 26” x 33” 11 1 323-7490 door set, with lock, 537-CD/CR 12 4 932-1095 stud, threaded, s/s, 1/4-20 x .75 13 4 932-1401 nut, 1/4-20, locking Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 5 1 14 15 16 8 Replacement Parts List For 549-CD KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00128 fixture, flour. light, 36 remote shelf support 6 4 001-5235 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom 9 1 323-4697 door assembly, with lock 10 1 216-2677 fan, axial Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Replacement Parts List For 561-CD KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00129 fixture, flour. light, 48 remote shelf support 6 4 001-5277 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom door assembly, PIKE, with lock 9 1 323-4698 10 1 216-2677 fan, axial 11 1 397-8125 shelf, top center 12 1 397-8126 shelf, bottom center Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 Replacement Parts List For 573-CD KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00130 fixture, flour. light, 60 remote shelf support 6 4 001-5295 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom door assembly, PIKE, with lock 9 1 323-4699 10 1 216-2677 fan, axial 11 1 397-8127 shelf, top center 12 1 397-8128 shelf, bottom center Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & Pike door keys #323-3988 10 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Replacement Parts List For 537CR/CRR KEY Quantity 9 11 10 2 4 6 7 3 13 12 6 5 1 14 15 16 DELFIELD PART# DESCRIPTION 1 1 001-3131 mirror, acrylic, RH, 500-CR 2 1 001-3132 mirror, acrylic, LH, 500-CR 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 001-5285 diffuser, air 537-CD/CR 6 2 XMK00127 fixture, flour. light, 24 remote 7 4 001-5407 support, shelf, 537-CD/CR 8 1 001-5407 divider, air flow, 537-CR 9 1 397-8137 shelf, adjustable, 21” x 33” 10 1 397-8138 shelf, adjustable, 26” x 33” 11 1 323-7490 door set, with lock, 537-CD/CR 12 4 932-1095 stud, threaded, s/s, 1/4-20 x .75 13 4 932-1401 nut, 1/4-20, locking 14 1 001-5422 cover, coil, 537-CR 15 4 001-5252 clip, holding, coil cover 16 4 932-1238 screw, #8 x .75, H/N-P-TR-A Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 8 Replacement Parts List For 549-CR/CRR KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 2 1 001-3132 mirror, acrylic, RH mirror, acrylic, LH 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00128 fixture, flour. light, 36 remote 6 4 001-5235 shelf support 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom 9 1 323-4697 door assembly, with lock Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 11 500 Series Display Cases Service and Installation Manual Replacement Parts List For 561-CR/CRR KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 2 1 001-3132 mirror, acrylic, RH mirror, acrylic, LH 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00129 fixture, flour. light, 48 remote 6 4 001-5277 shelf support 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom door assembly, PIKE, with lock 9 1 323-4698 10 1 397-8125 shelf, top center 11 1 397-8126 shelf, bottom center Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 Replacement Parts List For 573-CR/CRR KEY Quantity DELFIELD PART# DESCRIPTION 1 1 001-3133 2 1 001-3132 mirror, acrylic, RH mirror, acrylic, LH 3 1 397-8121 holder, adj. shelf, RH 4 1 397-8120 holder, adj. shelf, LH 5 2 XMK00130 fixture, flour. light, 60 remote 6 4 001-5295 shelf support 7 2 397-8122 shelf, top 8 2 397-8123 shelf, bottom door assembly, PIKE, with lock 9 1 323-4699 10 1 397-8127 shelf, top center 11 1 397-8128 shelf, bottom center Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988 12 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Replacement Parts List For 549-CH KEY 15 1 11 4 3 10 4 3 5 13 14 6 2 12 7 8 9 16 DELFIELD PART# DESCRIPTION 1 323-4055 door set, 49” curved glass 2 345-5439 glass, curved, 1” insulated, 47” 3 219-3959 bulb, 25W, Teflon coated, clear 4 219-3960 lamp holder, twin-threaded 5 219-3970 heater, pad, 115V/90W 6 XMK00106 warmer, food, 208V, no drain 7 219-4212 switch, 30A 120/277V 8 219-0154 switch, rocker, 20A/125V, 15A/250V 9 351-6059 thermometer, digital, solar/batt 10 105-0183 extrusion, polyethylene, blk, vertical, RH 11 105-0173 extrusion, polyethylene, blk, vertical, LH 12 105-0184 extrusion, polyethylene, blk, curved, RH 13 105-0174 extrusion, polyethylene, blk, curved, LH 14 001-5414 trim, side, exterior, RH 15 001-5415 trim, side, exterior, LH 16 001-6855 trim, front, laminate Replacement Parts List For 561-CH KEY 15 1 323-4068 door set, 61” curved glass 2 345-5441 glass, curved, 1” insulated, 59” 3 219-3959 bulb, 25W, Teflon coated, clear 4 219-3960 lamp holder, twin-threaded 5 219-3970 heater, pad, 115V/90W 6 XMK00106 warmer, food, 208V, no drain 10 7 219-4212 switch, 30A 120/277V 4 3 8 219-0154 switch, rocker, 20A/125V, 15A/250V 1 11 13 4 3 5 14 6 2 12 16 DELFIELD PART# DESCRIPTION 7 8 9 9 351-6059 thermometer, digital, solar/batt 10 105-0183 extrusion, polyethylene, blk, vertical, RH 11 105-0173 extrusion, polyethylene, blk, vertical, LH 12 105-0184 extrusion, polyethylene, blk, curved, RH 13 105-0174 extrusion, polyethylene, blk, curved, LH 14 001-5414 trim, side, exterior, RH 15 001-5415 trim, side, exterior, LH 16 001-6866 trim, front, laminate For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 13 500 Series Display Cases Service and Installation Manual Replacement Parts List For 573-CH KEY 15 1 11 4 3 10 4 3 13 11 5 14 6 2 12 16 7 8 9 DELFIELD PART# DESCRIPTION 1 323-4069 door set, 73” curved glass 2 345-5443 glass, curved, 1” insulated, 71” 3 219-3959 bulb, 25W, Teflon coated, clear 4 219-3960 lamp holder, twin-threaded 5 219-3970 heater, pad, 115V/90W 6 XMK00106 warmer, food, 208V, no drain 7 219-4212 switch, 30A 120/277V 8 219-0154 switch, rocker, 20A/125V, 15A/250V 9 351-6059 thermometer, digital, solar/batt 10 105-0183 extrusion, polyethylene, blk, vertical, RH 11 105-0173 extrusion, polyethylene, blk, vertical, LH 12 105-0184 extrusion, polyethylene, blk, curved, RH 13 105-0174 extrusion, polyethylene, blk, curved, LH 14 001-5414 trim, side, exterior, RH 15 001-5415 trim, side, exterior, LH 16 001-6867 trim, front, laminate Replacement Parts List For 549-OR KEY 1 5 14 6 13 2 3 4 7 16 8 9 14 10 17 18 18 10 15 11 9 19 12 20 21 17 14 25 23 24 22 DELFIELD PART# DESCRIPTION 1 001-5558 baffle, fan 49” 2 216-2667 motor, fan, morrill 3 351-6075 blade, fan, 7” dia., aluminum 4 397-8070 bracket, fan motor 5 218-2414 harness, fan motor, 78” 6 351-6097 coil, evaporator, custom, 49” 7 351-6273 valve, expansion, 1/4, HI, 404A 8 XMK-00132 fixture, fluorescent light, 36” 9 001-5554 back, interior, louvered 10 001-5555 diffuser, air, LH & RH 11 105-0183 extrusion, polyethylene, blk, vert, RH 12 105-0173 extrusion, polyethylene, blk, vert, LH 13 105-0184 extrusion, polyethylene, blk, curved, RH 14 105-0174 extrusion, polyethylene, blk, curved, LH 15 001-5414 trim, side, exterior, RH 16 001-5415 trim, side, exterior LH 17 001-6855 trim, front, laminate, 549 18 001-5278 louvers, s/s, 15 x 17 19 351-6038 thermometer, dial 20 001-5243 panel, access 21 219-3903 ballast, rapid start, 36” lamp 22 219-3919 switch, 15A/120V 23 351-6247 control, pressure, high 24 509-0025 control, temperature, -30-100 25 352-6731 condensing unit, 1/2 hp, R-404A, med For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Fluorescent Light 7 1 8 9 2 7 5 4 6 3 KEY DELFIELD PART# DESCRIPTION 1 SMK00571 cap, end, top mtg, pigtail, -rem. 2 SMK00572 cap, end, top mtg, blank, -rem. 3 170-1045 diffuser, fluor. light, 24” 170-1046 diffuser, fluor. light, 36” 170-1047 diffuser, fluor. light, 48” 170-1054 diffuser, fluor. light, 60” 4 219-3906 lamp, fluorescent, 24” 219-3907 lamp, fluorescent, 36” 219-3908 lamp, fluorescent, 48” 219-3909 lamp, fluorescent, 60” 5 219-3939 lamp holder, left 6 219-3940 lamp holder, right 7 932-1266 screw, #8-32 x .50 8 218-3613 pigtail, male, 3.5”, rem. ballast 218-3595 pigtail, male, 9”, rem. ballast 9 932-1010 nut, hex, starlock, s/s, #6-32 *Refer to the exploded view of unit for a complete assembly part number For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 15 500 Series Display Cases Service and Installation Manual Door Assembly KEY DELFIELD PART# DESCRIPTION 323-7490 complete assembly, 537-CD/CR/CRR 323-4697 complete assembly, 549-CD/CR/CRR 323-4055 complete assembly, 549-CH 323-4698 complete assembly, 561-CD 323-4699 complete assembly, 573-CD 1 323-4636 single roller, 537, 549 & 561 323-4637 double roller, 573 2 order by size bumper gasket, 241/8 & 537 323-3936 bumper gasket, 245/32, 549, 561 & 573 3 order by size wiper gasket, 537 323-3936 wiper gasket, 2223/32, 549, 561 & 573 spring 12”, green, 537 4 323-3947 323-3949 spring 12”, 549 323-3945 spring 23”, gold, 561 5 6 323-3946 spring 30”, gold, 573 order by size bottom track, 34 3/16, 537, black 323-3904 bottom track, 46 3/16, 549, black order by size bottom track, 46 3/16, 549-CH, black 323-3909 bottom track, 58 3/16, 561, black 323-3912 bottom track, 70 3/16, 573, black order by size top track, 34 3/16, 537, black 323-3904 top track, 46 3/16, 549, black 323-3922 top track, 58 3/16, 561 order by size Alum. top track, 46 3/16, 549-CH 323-3925 top track, 70 3/16, 573 4 Please Note: Gaskets & tracks order by dimensions • Plastic door glides order by description reference #323-4055, 549-CH 6 2 3 4 1 1 2 1 1 16 5 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Compressor/Coil Assembly 537/549/561-CR/CRR KEY DELFIELD PART# DESCRIPTION 1 010-1916 coil pan assembly 2 001-5251 bracket, fan mounting 001-5417 bracket, fan mounting (537-CR) 3 219-3919 switch, toggle, SPST 4 219-3903 ballast, rapid start (549 & 537-CR) 219-3904 ballast, rapid start (561) 5 6 219-3942 control, SPST 219-3927 control, SPST (537-CR) 351-6231 evaporator coil, 404A 351-6072 evaporator coil, 404A (537-CR) 7 216-2667 motor, fan, 1450 rpm, CW (537, 549 & 561) 8 351-6184 blade, fan, 7” plastic, CW 9 352-6729 condensing unit, 1/2 h.p., 404A (549-CR) 352-6746 condensing unit, 1/3 h.p., 404A (537-CR) 352-6732 condensing unit, 3/4 h.p., 404A (561-CR) 10 351-6084 valve, expansion, 1/2”, 404A 11 218-3445 harness, evaporator fan Compressor/Coil Assembly 573-CR/CRR KEY DELFIELD PART# DESCRIPTION 1 010-1926 coil pan assembly 2 001-5292 bracket, fan mounting 3 219-3919 switch, toggle, SPST 4 219-3905 ballast, rapid start 5 219-3942 control, SPST 6 351-6246 evaporator coil, 404A 7 216-2667 motor, fan, 1450 rpm, CW 8 351-6184 blade, fan, 7” plastic, CW 9 352-6732 condensing unit, 3/4 h.p., 404A (573-CR only) 10 351-6084 valve, expansion, 1/2”, 404A 11 218-3445 harness, evaporator fan 17 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 17 500 Series Display Cases Service and Installation Manual Delfield Food Well (DFW) Assembly: with infinite control For 500-CH Heated Units KEY DELFIELD PART# DESCRIPTION XMK00106 Complete assembly, infinite w/o drain 1 GMK00061 Deflector plate 2 GMK00062 Bottom cover 3 016-0014 Food well, with drain 4 932-1353 Screw 5 219-4007 Element 6 932-1379 Screws (2) 7 343-4663 Insulation 8 219-4335 Thermostat non-adjustable 9 932-1007 Screw 10 GMK00063 Drain cover 11 932-1007 Screws (2) 12 219-4110 Infinite control, 240V 13 323-4557 Infinite control knob 14 219-4095 Pilot light, amber 10 2 4 7 NOTE: If you need four or more component parts, you must buy a complete assembly. 1 9 8 6 5 11 INFINITE CONTROL KNOB 3 14 12 18 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 13 500 Series Display Cases Service and Installation Manual Replacement Parts List — not shown on exploded views DELFIELD PART# DESCRIPTION DELFIELD PART# DESCRIPTION CR & CRR Models (misc. parts) OR Models (misc. parts) Harness, wiring-female, 84” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3596 Motor, evaporator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216-2667 Glass, curved, 1”, insulated, 35” (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5319 Blade, fan, 7” dia., CW, 20 deg, alum . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6075 Glass, curved, 1”, insulated, 47” (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5439 Harness, light/fan motor, 78’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3414 Glass, curved, 1”, insulated, 59” (561) . . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5441 Coil, evap., customer, 49” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6097 Glass, curved, 1”, insulated, 71” (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5443 Cond. unit, 1/2 h.p., R-404A, med . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352-6731 Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4696 Control, temperature, -30-100%D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 509-0025 Fixture, fluorescent light, 24” remote, top light (537) . . . . . . . . . . . . . . XMKOO131 Valve, Expansion, 1/4, R-404A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6273 Fixture, fluorescent light, 36” remote, top light (549) . . . . . . . . . . . . . . XMKOO132 Ballast, rapid start, 36” lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3903 Fixture, fluorescent light, 48” remote, top light (561) . . . . . . . . . . . . . . XMKOO133 Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3919 Fixture, fluorescent light, 60” remote, top light (573) . . . . . . . . . . . . . . XMKOO134 Timer, 24 hours, clock face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4345 Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5278 Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3445 Louver, s/s, 15 x 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5279 Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8070 Harness, light/fan motor, 78” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3414 Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5278 Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3919 Shelf, Lexan, .5” x 10” x 45.5” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354-5339 Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8121 Dial, Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6038 Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8120 CH Models (misc. parts) Control, pressure, dual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3942 Lamp holder, twin-threaded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3960 Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8070 Bulb, 25W, Teflon coating, clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3959 Blade, fan, 7” dia., Lexan, clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6184 Heater, pad, 115V/90W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3970 Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3445 Thermostat, nonadjustable, 480°F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4335 Support, shelf, (549-CR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5235 Thermometer/digital, solar/batt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6059 Shelf, top/end, adj., 21 x 22.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8122 Switch, rocker, 20A/125V, 15A/250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-0154 Shelf, bottom/end, adj., 26 x 22.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8123 Switch, 30A, 120/277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4212 Door set, 49” disp. case, with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4697 Door set, 61” disp. case, with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4698 Ballasts Shelf, top/center, adj., 21 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8125 120V ballast (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3902 Shelf, bottom/center, adj., 26 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8126 120V ballast (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3903 120V ballast (561) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3904 CD Models (misc. parts) 120V ballast (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3905 Harness, wiring-female, 84” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3596 220V ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . special order Glass, curved, .25”, insulated, 35” (537) . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5400 Glass, curved, .25”, insulated, 47” (549) . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5440 Glass, curved, .25”, insulated, 59” (561) . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5442 Glass, curved, .25”, insulated, 71” (573) . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5444 Fixture, fluorescent light, 24” remote, top light (537) . . . . . . . . . . . . . . XMKOO131 Fixture, fluorescent light, 36” remote, top light (549) . . . . . . . . . . . . . . XMKOO132 Fixture, fluorescent light, 48” remote, top light (561) . . . . . . . . . . . . . . XMKOO133 Fixture, fluorescent light, 60” remote, top light (573) . . . . . . . . . . . . . . XMKOO134 Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4696 Switch, 15A/120V, (2) SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3918 Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8121 Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8120 Pigtail, male, 9”, rem. ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3595 Support, shelf, (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5235 Shelf, bottom/end, adj., 21 x 22.5 (549 & 561) . . . . . . . . . . . . . . . . . . . . . 397-8122 Shelf, adjustable, 21 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8137 Shelf, top, center, adj. 21 x 24 (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8127 Shelf, bottom/end, adj., 26 x 22.5 (549 & 561) . . . . . . . . . . . . . . . . . . . . . 397-8123 Shelf, adjustable, 26 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8138 Shelf, bottom, center, adj. 26 x 24 (573) . . . . . . . . . . . . . . . . . . . . . . . . . 397-8128 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 19 500 Series Display Cases Service and Installation Manual Standard Labor Guidelines To Repair or Replace Parts on Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. • Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim. LABOR OF 1-HOUR IS ALLOWED TO REPLACE: • Thermostat • Infinite Switch • Door Jamb Switch • Solenoid Coil • Hi-limit/Thermal Protector Switch • Fan Delay/Defrost Termination Switch • Compressor Start Components and Overload Protector • Defrost Timer • Thermometer • Gear Box • • • • • • • • • Contactor/Relay Transformer Evaporator/Condenser Fan Motor and Blade Circulating Fan Motor and Blade Microprocessor Control Water Level Sensor/Probe Door Hinges, Locks, and Gaskets Condensate Element Springs/Lowerator LABOR OF 2 HOURS TO REPLACE: • Drawer Tracks/Cartridges • Defrost Element • Pressure Control • Heating Element • Solenoid Valve • Locate/Repair Leak LABOR OF 3 HOURS TO REPLACE: • EPR or CPR Valve • Condenser or Evaporator Coil • Expansion Valve LABOR OF 4 HOURS TO REPLACE • Compressor This includes recovery of refrigerant and leak check. $55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.) REFRIGERANTS • R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed. • R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed. • R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed. 20 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual Standard One Year Warranty (One year parts, 90 days labor.) The Delfield Company (“Delfield”) warrants to the Original Purchaser of the Delfield product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including the date of installation within thirty (30) days of receipt of the Unit, one (1) year from the date of installation. During this one year warranty period, Delfield will repair or replace any defective part or portion there of returned to Delfield by the Original Purchaser which Delfield determines was defective due to faulty material or workmanship. The Original purchaser will pay all labor, crating, freight and related costs incurred in the removal of the Unit of defective component and shipment to Delfield, except that during a period of either ninety (90) days from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including the date of installation within thirty (30) days of receipt of the Unit, ninety (90) days from the date of installation Delfield will pay all related labor costs. Delfield will pay the return costs if the Unit or part thereof was defective. The term “Original Purchaser” as used herein means that person, firm, association, or corporation for whom the Unit was originally installed. This warranty does not apply to any Unit or part thereof that has been subjected to misuse, neglect, alteration, or accident, such as accidental damage to the exterior finish, operated contrary to the recommendations specified by Delfield; or repaired or altered by anyone other than Delfield in any way so as to, in Delfield’s sole judgement, affect its quality or efficiency. This warranty does not apply to any Unit that has been moved from the location where it was originally installed. This warranty also does not cover the refrigerator drier or the light bulbs used in the Unit. The warranty is subject to the user’s normal maintenance and care responsibility as set forth in the Service and Installation Manual, such as cleaning the condenser coil, and is in lieu of all other obligations of Delfield. Delfield neither assumes, nor authorizes any other person to assume for Delfield, any other liability in connection with Delfield’s products. Removal or defacement of the original Serial Number or Model Number from any Unit shall be deemed to release Delfield from all obligations hereunder or any other obligations, express or implied. Parts furnished by suppliers to Delfield are guaranteed by Delfield only to the extent of the original manufacturer’s express warranty to Delfield. Failure of the Original Purchaser to receive such manufacturer’s express warranty to Delfield. Failure of the Original Purchaser to receive such manufacturers warranty shall in no way create any warranty, expressed or implied, or any other obligation or liability on Delfield’s part in respect thereof. IF THE CUSTOMER IS USING A PART THAT RESULTS IN A VOIDED WARRANTY AND A DELFIELD AUTHORIZED REPRESENTATIVE TRAVELS TO THE INSTALLATION ADDRESS TO PERFORM WARRANTY SERVICE, THE SERVICE REPRESENTATIVE WILL ADVISE CUSTOMER THE WARRANTY IS VOID. SUCH SERVICE CALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER’S THEN APPLICABLE TIME AND MATERIALS RATES. CONSIDER: CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE. If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective, the Original Purchaser must accept delivery of the replacement part of a C.O.D. basis, with credit being issued after the part has been received and inspected at Delfield’s plant and determined by Delfield to be within this warranty. Under no condition does this warranty give the Original Purchaser the right to replace the defective Unit with a complete Unit of the same manufacturer or of another make. Unless authorized by Delfield in writing, this warranty does not permit the replacement of any part, including the motor-compressor, to be made with the part of another make or manufacturer. No claims can be made under this warranty for spoilage of any products for any reason, including system failure. The installation contractor shall be responsible for building access, entrance and field conditions to insure sufficient clearance to allow any hood(s), vent(s), or Unit(s) if necessary, to be brought into the building. Delfield will not be responsible for structural changes or damages incurred during installation of the Unit or any exhaust system. Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war, governmental restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts of nature, short or reduced supply of raw materials, or discontinuance of the parts by the original part manufacturer. Except as provided in any Additional Four Year Protection Plan, if applicable, and the Service Labor Contract, if applicable, the foregoing is exclusive and in lieu of all other warranties, whether written or oral, express or implied. This warranty supersedes and excludes any prior oral or written representations or warranties. Delfield expressly disclaims any implied warranties of merchantability, fitness for a particular purpose of compliance with any law, treaty, rule or regulation relating to the discharge of substances into the environment. The sole and exclusive remedies of any person relating to the Unit, and the full liability of Delfield for any breach of this warranty, will be as provided in this warranty. Other than this Delfield Standard One Year Limited Warranty, any applicable Delfield Additional Four Year Protection Plan or applicable Delfield Service Labor Contract, the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the unit or any other part thereof. In no event will Delfield be liable for special, incidental or consequential damages, or for damages in the nature of penalties. IF DURING THE WARRANTY PERIOD, CUSTOMER USES A PART FOR THIS DELFIELD EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM DELFIELD OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, DELFIELD AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER. If the warranty becomes void, Customer may purchase from Delfield, if available, a Service Agreement or service at the then current time and materials rate. For more information on Delfield warranty’s log on and check out the service section of our web site at www.delfield.com. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 21 500 Series Display Cases Service and Installation Manual Additional Four Year Protection Plan Delfield Model# Serial # Installation Date In addition to the Standard One Year Warranty on the MotorCompressor contained in the above listed Delfield product (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield’s option, the defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or any part thereof, for the Original Purchaser only, at any time during the four (4) years following the initial one (1) year period commencing on the date of installation for the Original Purchaser. Failure of the Original Purchaser to register the registration card containing the Original Purchasers name, address, date of installation, model number and serial number of the Unit containing the Motor-Compressor within 30 days from the date of installation shall void this warranty. This additional warranty is only available if the Motor-Compressor is inoperative due to defects in material or factory workmanship, as determined by Delfield in its sole judgement and discretion. The Original Purchaser shall be responsible for returning the defective Motor-Compressor to Delfield prepaid, F.O.B. at the address shown on the back cover of this manual. The term “Original Purchaser” as used herein means that person, firm, association, or corporation for whom the Unit was originally installed. The term “Motor-Compressor” as used herein does not include unit base, air or water cooled condenser, receiver, electrical accessories such as relay, capacitors, refrigerant controls, or condenser fan/motor assembly. This warranty does not cover labor charges incidental to the replacement of parts. This warranty further does not include any equipment to which said condensing unit is connected, such as cooling coils, temperature controls or refrigerant metering devices. This warranty shall be void if the Motor-Compressor, in Delfield’s sole judgement, has been subjected to misuse, neglect, alteration or accident, operated contrary to the recommendations specified by the Unit manufacturer, repaired or altered by anyone other than Delfield in any way so as, in Delfield’s sole judgment, to affect its quality or efficiency or if the serial number has been altered, defaced or removed. This Warranty does not apply to a Motor-Compressor in any Unit that has been moved from the location where it was originally installed. The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty. 22 (for Motor-Compressor only) General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war, governmental restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts of nature, short or reduced supply of raw materials, or discontinuance of any part or the MotorCompressor by the unit manufacturer. Replacement of a defective Motor-Compressor is limited to one (1) Motor-Compressor by us during the four (4) year period. Delfield shall replace the Motor-Compressor at no charge. This warranty does not give the Original Purchaser of the MotorCompressor the right to purchase a complete replacement MotorCompressor of the same make or of another make. It further does not permit the replacement to be made with a Motor-Compressor of another kind unless authorized by Delfield. In the event Delfield authorizes the Original Purchaser to purchase a replacement Motor-Compressor locally, only the wholesale cost of the MotorCompressor is refundable. Expressly excluded from this warranty are damages resulting from spoilage of goods. Except as provided in any applicable Standard One Year Limited Warranty or applicable Service Labor Contract, the foregoing is exclusive and in lieu of all other warranties, whether written or oral, express or implied. This Warranty supersedes and excludes any prior oral or written representations or warranties. Delfield expressly disclaims any implied warranties of merchantability, fitness for a particular purpose or compliance with any law, treaty, rule or regulation relating to the MotorCompressor, and the full liability of Delfield for any breach of this warranty, will be as provided in this warranty. Other than any applicable Delfield Standard One year Limited Warranty, this Delfield Additional Four Year Protection Plan and any applicable Delfield Service Labor Contract, the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the Motor-Compressor or any part thereof. In no event will Delfield be liable for special, incidental or consequential damages, or for damages in the nature of penalties. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 500 Series Display Cases Service and Installation Manual notes: For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 23 Delfield ™ Mt. Pleasant, MI ® Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. Delfield ™ ® 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (989) 773-3210 • www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. ©2010 The Delfield Company. All rights reserved. Printed in the U.S.A. DM500 04/10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project