Kobe Milo CH27 SQ3-XX Installation Manual

Kobe Milo CH27 SQ3-XX Installation Manual

KOBE Range Hoods Premium Series Milo CH27 Series

Model No.: Under Cabinet: CH2730SQ3 XX (30”) CH2736SQ3 XX (36”) Wall Mount: CH2730SQ3-WM XX (30”) CH2736SQ3-WM XX (36”) CH2748SQ3-WM XX (48”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

IMPORTANT READ THIS FIRST

READ BEFORE INSTALLATION

1. Carefully check all contents of packages. 2. Thoroughly inspect the unit for any shipping damages, cosmetic damages or defects. 3. Have a certified contractor/electrician test the unit before installation.

IF THERE IS ANY PROBLEM:

1.

DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL.

2. Have your original invoice as proof of purchase and product serial number ready.

3. Contact your merchant for product replacement due to shipping damages, cosmetic damages or defects.

4. For all other issues, call 1-877-BUY-KOBE (289-5623), or e-mail to [email protected]

.

NO RETURN, NO REFUND, NO EXCHANGE IF: 1. PRODUCT HAS BEEN INSTALLED 2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED 3. MISSING ORIGINAL PACKAGING MATERIAL AND/OR PARTS

[ENGLISH]

- READ AND SAVE THESE INSTRUCTIONS -

CONTENTS

IMPORTANT SAFETY INSTRUCTIONS ......................................................................... 1 COMPONENTS OF PACKAGE ....................................................................................... 3 INSTALLATION ............................................................................................................... 5 OPERATING INSTRUCTIONS...................................................................................... 11 MAINTENANCE ............................................................................................................ 13 SPECIFICATIONS ......................................................................................................... 14 MEASUREMENTS & DIAGRAMS................................................................................. 15 PARTS LIST .................................................................................................................. 17 CIRCUIT DIAGRAM ...................................................................................................... 21 TROUBLE SHOOTING ................................................................................................. 22 WARRANTY .................................................................................................................. 23 WARRANTY INFORMATION FORM ............................................................................. 25

- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -

A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S

IMPORTANT SAFETY INSTRUCTIONS

- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -

WARNING:

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING.

1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE PANEL. b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages. NOTE - - This warranty is void without an authorized agent’s receipt or if unit is damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty. KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.

WARNING:

TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE TOP GREASE FIRE:

1) Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container. 2) Always turn hood ON when cooking. 3) Use high settings on cooking range ONLY when necessary. 4) Do not leave cooking range unattended when cooking. 5) Always use cookware and utensils appropriate for the type and amount of food prepared. 6) Use this unit only in the manner intended by the manufacturer. 7) Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally. 8) Clean ventilating fan frequently. 1

What to Do In The Event Of a Range Top Grease Fire

• SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. • NEVER PICK UP A BURNING PAN – You May Get Burned. • DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result. • Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.

What to Do If You Smell Gas

• Extinguish any open flame. • Do not try to turn on the lights or any type of appliance. • Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away.

CAUTION

1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion 3) and exhausting of gases through the flue (chimney) to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities. 4) Activating any switch on may cause ignition or an explosion. 5) Due to the size and weight of this hood, installation by 2 persons is recommended.

ELETRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amount of mercury, which must be recycled or disposed of according to Local, State, and Federal Code.

2

COMPONENTS OF PACKAGE

(Must keep all material for returns or refunds)

For Under Cabinet Application

CH2730SQ3 XX (30”) / CH2736SQ3-XX (36”)

Range Hood Box {A} KOBE Range Hood {B} Warranty Registration Card {C} Quick Reference Guide {D} Airflow Efficiency Panel x 1 (30” hood) {E} 6” Round Plastic Collar x 3 (36” hood) {F} Wire Cap x 3 {G} Screws Package {H} Stainless Steel Filter x 1 {A} {B} {C} {D} {E}

*Pre-Installed

{F}

Wire caps (3)

{G}

M4 x 1 1/2” (4)

{H}

*Pre-Installed • FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.koberangehoods.com OR CONTACT KOBE RANGE HOODS AT (626) 775-8880. 3

(Must keep all material for returns or refunds)

For Wall Mount Application

CH2730SQ3-WM XX (30”) / CH2736SQ3-WM-XX (36”) / CH2748SQ3-WM-XX (48”)

Range Hood Box {A} KOBE Range Hood {B} Warranty Registration Card {C} Quick Reference Guide {D} Airflow Efficiency Panel x 1 (30” hood) x 3 (36” & 48” hood) {E} 6” Round Plastic Collar {F} Duct cover Mounting Bracket {G} Adjustable Duct Cover {H} Screws Package {I} Wire Cap x 3 {J} Screws Package {K} Stainless Steel Filter x 1 {A} {B} {C} {D} {E}

*Pre-Installed

{F} {G} {H}

3/16 “x 3/8” (8PCS)

{I}

Wire Caps (3)

{J}

M4 x 1 1/2” (4)

{K}

*Pre-Installed • FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.koberangehoods.com

OR CONTACT KOBE RANGE HOODS AT (626) 775-8880. 4

INSTALLATION

Calculation before Installation

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING To calculate installation, please refer to TABLE 1 and TABLE 2. (All calculation in inches).

- FOR UNDER THE CABINET - TABLE 1

A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”)

C = Preferred Height of Counter Top to Hood Bottom (Minimum 26” to 30”)

D = Height of Hood E = Height of the Cabinet

- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) - TABLE 2

A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”)

C = Preferred Height of Counter Top to Hood Bottom (Minimum 26” to 30”)

D = Height of Hood E = Height of Duct Cover [F [A – (B+C)] – D] F = Height of the Hood Installation 5

SAFETY WARNING

HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: DO NOT USE AN ELECTRIC SCREWDRIVER. USE HAND TOOLS ONLY. DO NOT OVER TIGHTEN SCREWS AS THIS MAY CAUSE DAMAGE TO THE HOOD.

Installation Contents UNDER CABINET INSTALLATION WALL MOUNT INSTALLATION 7 9 6

UNDER CABINET INSTALLATION

Applicable Model: CH2730SQ3 XX (30”) / CH2736SQ3-XX (36”)

Preparation before Installation

Figure 1 - - - NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE - VENT OPENING. Decide the location of the venting pipe from the hood - - - - to the outside. (Figure 1) A straight, short vent run will allow the hood to perform more efficiently. Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. Temporarily wire the hood to test for proper operation before installing. If the hood does not operate, check the circuit breaker or house fuse. If the hood is still not working, disconnect power supply and check the continuity of all wire connections. Peel protective film off the hood (if any). Use duct tape to seal joints between pipe sections. Make sure the cabinet has full access opening for the hood as shown on Figure 2. Using reference on Page 15 to measurement and create access opening for electrical wire and exhaust under the cabinet.

Hood Installation

Figure 2

CAUTION: Do not use an electric screwdriver. Use hand tools only. Do not over tighten screws as this may cause damage to the hood.

Figure 3

CAUTION: If moving the cooking range is necessary to install the hood, turn off the power in an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. And use a protective covering to protect cooktop and/or countertop from damage.

1. Using references on TABLE 1 and measurements on page 15 mark the leveling point for hood mounting bracket inside the cabinet. 2. Secure two hood mounting screws (provided) inside the cabinet leaving 1/8” away from the cabinet as shown on Figure 3. 3. Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws as shown in Figure 4. 4. Refer to Figure 5. Align hood-mounting bracket to the mounting screws inside the cabinet and hook hood into place. Secure and tighten the mounting screws. Figure 4

CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

7

Ductwork Installation

5. Use steel pipe to connect the 6” round plastic collar {F} on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6.

Wiring to Power Supply THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

6. If hood is operating normally, connect three wires (black, white and green) to house wires and cap with wire connections. 7. Store wires in the wiring box.

Install / Uninstall Accessories

8. Place the airflow efficiency panel underneath the hood. (Figure 7)

Final Assembly

9. Turn power ON in control panel. Check all lights and fan operation. 10. Leave this Installation Instructions Operation Manual for the homeowner. and 8 Figure 5 Figure 6 Figure 7

WALL MOUNT INSTALLATION

Applicable Model: CH2730SQ3-WM XX (30”) / CH2736SQ3-WM-XX (36”) / CH2748SQ3-WM-XX (48”)

Preparation before Installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE - - VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 8. A straight, short venting run will allow the hood to perform more efficiently. - - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. Temporarily wire the hood to test for proper operation before installation. If the hood does not operate, check the circuit breaker or house fuse. If the hood is still not working, disconnect power supply and check the continuity of all wire - - - connections. Peel protective film off the hood (if any). Use duct tape to seal the joints between pipe sections. If necessary, prepare back wall frame with cross framing lumber for secure installation. Using references on TABLE 2 and measurements on page 15-16, decide the level of the lumber. Refer to Figure 9.

Hood Installation CAUTION: Do not use an electric screwdriver. Use hand tools only. Do not over tighten screws as this may cause damage to the hood.

Figure 8 Figure 9 Figure 10 Mounting Screws

CAUTION: If moving the cooking range is necessary to install the hood, turn off the power in an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. And use a protective covering to protect cooktop and/or countertop from damage.

1. Use reference on TABLE 2 and measurements on page 15-16, mark the leveling point of the hood. Position mounting screws (provided) on the wall, leaving 1/8” away from the wall as shown in Figure 10. 2. Optional step for adjusting hood-mounting bracket height: - Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws as shown in Figure 11. 3. Align hood-mounting bracket to the two screws on the wall and hook hood into place. Tighten screws to secure hood to the wall. Figure 11

CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

9

Wiring to Power Supply THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

4. If hood is operating normally, connect three wires (black, white and green) to house wires and cap with wire connectors. 5. Store wires in wiring box.

Ductwork Installation

6. Use steel pipe to connect the exhaust on the hood to the ductwork. Use duct tape to make all joints secure and air tight.

Duct Cover Installation

7. Mark the position of the Duct Cover-Mounting Bracket {G}. Use reference

E

from TABLE 2 and measurements on page 15-16. Attach and secure Duct Cover-Mounting Bracket {G} with two screws (provided). Refer to Figure 12. NOTE: Inner duct cover will cover the Duct Cover-Mounting Bracket. 8. Position the entire duct cover up onto the hood. 9. Secure the inner duct cover with two (3/16” x 3/8”) screws {I} to the Duct Cover-Mounting Bracket {G}. Shown in Figure 13. 10. Secure the outer duct cover with two (3/16” x 3/8”) screws {I} to the Blower Housing.

Install / Uninstall Accessories

11. Place the airflow efficiency panel underneath the hood. (Figure 14)

Final Assembly

12. Turn power ON in control panel. Check all lights and fan operation. and 13. Leave this Installation Instructions Operation Manual for the homeowner. 10 Figure 12 Figure 13 Figure 14 Attach Together

OPERATING INSTRUCTIONS

Control Panel Light Indicator

Q L H D ON Standby QuietMode™ speed Low speed High speed Delay Shut-Off On Mode Auto Mode

Auto Mode

• The hood has advanced built-in temperature sensors. When the sensor detects by ~7°F degrees** of temperature differential between the hood and the surrounding environment, the fan and lights on the hood will turn on automatically. • The hood has 3 speeds - QuietMode™ (Q), Low (L), and High (H). The speed will automatically adjust to the higher and lower speeds depending on ~7°F degrees** of temperature differential between the hood and the surrounding environment. • Auto Mode is always enabled on this unit. You can still manually control functions such as speed, light, and delay shut-off. However, if the hood detects any lingering heat even after the range has been turned off, the Auto Mode function will turn the hood back on even if you manually shut off the fan and lights, so that it can continue to refresh the air quality.

Automatic Delay Shut-Off

• When your hood is on and the temperature of the hood equals the surrounding room temperature, the hood will automatically activate the delay shut-off and the fan speed will go into QuietMode (lowest speed). • The fan and the lights will automatically shut-off after 3 minutes. • Once the delay shut-off has been activated, the D and ON lights will both be on and you will hear a single audible beep. While the 3-minute countdown is running, the speed level can still be adjusted by pressing the fan speed button. • To override the Automatic Delay Shut-Off, press and hold the power button for 3 seconds, which will turn off the hood immediately. 11

*Please note the sensor will override this automatically when the sensor detects the 7°F-degree** temperature differential; and the hood and lights will turn on again.

Power Button

• To manually turn on the hood, press the power button once. • To Manually Activate the delay shut-off: When the ON light is green, you can manually activate the delay shut-off by pressing the power button and you will see the D + ON light turn on to indicate delay shut-off is activated. OR If the hood is on STANDBY mode, you can activate the delay shut-off by pressing the power button twice (once to turn it on and second time to activate delay shut-off). • To manually turn off the hood, press and hold the power button for 3 seconds to put on standby. • *Please note the sensor will override this automatically when the sensor detects the 7°F-degree** temperature differential between the hood and the surrounding environment, and the hood and lights will turn on again. When manually setting the delay shut-off, the fan and the lights will automatically shut-off after 5 minutes.

Light Button

• Press once for On/Off Light button control *Please note that when you manually turn on the hood, the lights will turn on as well.

Speed Button

• Press the speed control button to adjust the speed after the hood is on. • The fan cycle speeds are: QuietMode™ (Q) -> Low (L) -> High (H) **Please note: ~7°F degrees vary depending on the condition of your environment and stove/range you use. 12

MAINTENANCE

For optimal performance, clean the range hood surface and filters regularly.

To Clean Hood Surface CAUTION: NEVER USE ABRSIVE CLEANERS, PADS, OR CLOTHS.

***Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner.

Caution: Do not leave on too long as this may cause damage to hood finish.

Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood. 3. DO NOT allow deposits to accumulate or remain on the hood. 4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting. 5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful to the hood. Rinse with water after exposure and wipe dry with a clean lint free cloth.

To Clean Stainless Steel Filter / Airflow Efficiency Panel CAUTION: DRAIN OIL FROM STAINLESS STEEL FILTER & AIRFLOW EFFICIENCY PANEL REGULARLY TO PREVENT OVERFLOW.

1. Remove all the filters and panels.

RECOMMENDED USAGE OF GLOVES WHILE REMOVING

2. Using a sponge, wash with warm soapy water. Dry completely before returning into place.

***Note: Stainless Steel Filters & Airflow Efficiency Panels are top rack dishwasher safe.

13

SPECIFICATIONS

MODEL / SIZE COLOR CONSUMPTION / AMPERE Power Rating NUMBER OF BLOWER DESIGN BLOWER TYPE EXHAUST CONTROLS LIGHTS HOOD DIMENSION (W x D x H) DUCT COVER DIMENSION (W x D x H) OPTIONAL ACCESSORIES (W x D x H) WEIGHT (lbs) SPEED Air Capacity (CFM) Sone* (dB)

Under Cabinet Application Wall Mount Application CH2730SQ3 XX (30”) CH2730SQ3-WM-XX (30”) CH2736SQ3 XX (36”) CH2736SQ3-WM-XX (36”) CH2748SQ3-WM XX (48”) 18-Gauge Commercial Grade Stainless Steel 420W / 3.5A 120V / 60Hz 1 Seamless / Satin Finish Single Horizontal Squirrel Cage Top 6” Round 3-Speed Push Button with Temperature Sensor 3-Watt LED Light x 2 (30” , 36”) 3 Watt LED Light x 4 (48”)

CH2730SQ3-XX / CH2730SQ3-WM XX (30”)

29 3/4” x 19-11/16” x 13-1/4”

CH2736SQ3-XX / CH2736SQ3-WM XX (36”)

35 3/4” x 19-11/16” x 13-1/4”

CH2748SQ3-WM XX (48”)

47 3/4” x 19-11/16” x 13-1/4” 1) Standard Duct Cover (2pc. Adjustable)

CH02DC-1

(11-

CH02DC30-1

15/16” x 12-7/16” x 18-7/8”~37-3/8”) 2) Inner Duct Extension (Sold Separately) (11 15/16” x 12-7/16” x 30”) 1) 2) 30” Stainless Steel Back Panel

SSP30

(30” x 1/10” x 32”) 36” Stainless Steel Back Panel

SSP36

(36” x 1/10” x 32”) CH2730SQ3 CH2736SQ3 XX (30”) XX (36”) CH2730SQ3-WM XX (30”) CH2736SQ3-WM XX (36”) CH2748SQ3-WM XX (48”) QuietMode™ 250 2.0 NET 34.5 lbs 40.0 lbs 42.0 lbs 48.5 lbs 55.0 lbs Low 430 5.0 GROSS 44.0 lbs 50.0 lbs 53.5 lbs 60.0 lbs 69.5 lbs High 600 7.0 *One sone is equivalent to the sound of a refrigerator at 40 decibels. **Specifications subject to change without notice. 14

MEASUREMENTS & DIAGRAMS

***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters.

MODEL NO.: - FOR UNDER THE CABINET – CH2730SQ3 XX (30”) / CH2736SQ3-XX (36”) MODEL NO.: - FOR WALL MOUNT – CH2730SQ3-WM XX (30”) / CH2736SQ3-WM-XX (36”) / CH2748SQ3-WM-XX (48”)

15

***Hood-Mounting Bracket ***Duct Cover-Mounting Bracket 16

PARTS LIST

MODEL NO.: CH2730SQ3 XX (30”) CH2736SQ3 XX (36”) NO.

1 2 3 4 5 6 7 8 9 10 11

DESCRIPTION

6” Round Plastic Exhaust Blower System Stainless Steel Filter Control Unit Capacitor x 1PCS LED Light Driver

MODEL / SIZE

Temperature Sensor Processor Board CH2730SQ3-XX Light Panel Support CH2736SQ3-XX LED Light (3W) Airflow Efficiency Panel (14-5/8 ” x 12-7/16”) CH2730SQ3-XX Airflow Efficiency Panel (10-3/8 ” x 12-7/16”) CH2736SQ3-XX

PART NO.

L1-0505-0007 L1-0302-0120-590RO B101-27300-09-M L1-0404-3001-A L1-0401-0120-24 L1-0402-D001 L1-0404-3001-C L1-0404-3001-B B101-N2730-06 B101-N2736-06 L1-0403-0301 B010-27900-09-30 B010-27900-09-36 17

MODEL NO.: CH2730SQ3 XX (30”) CH2736SQ3 XX (36”)

18

MODEL NO.: CH2730SQ3-WM XX (30”) CH2736SQ3-WM XX (36”) CH2748SQ3-WM XX (48”) NO.

1 2 3 4 5 6 7 8 9 10 11 12 13 Duct Cover-Mounting Bracket Duct Cover 6” Round Plastic Exhaust Blower System Stainless Steel Filter Control Unit

DESCRIPTION

Capacitor x 1PCS LED Light Driver Temperature Sensor Processor Board

MODEL / SIZE

CH02DC-1 CH2730SQ3-XX Light Panel Support CH2736SQ3-XX CH2748SQ3-XX LED Light (3W) Airflow Efficiency Panel (14-5/8 ” x 12-7/16”) CH2730SQ3-WM-XX Airflow Efficiency Panel (10-3/8 ” x 12-7/16”) CH2736SQ3-WM-XX Airflow Efficiency Panel (14-9/16 ” x 12-7/16”) CH2748SQ3-WM-XX

PART NO.

L1-0203-0390 12-27900 L1-0505-0007 L1-0302-0120-590RO B101-27300-09-M L1-0404-3001-A L1-0401-0120-24 L1-0402-D001 L1-0404-3001-C L1-0404-3001-B B101-N2730-06 B101-N2736-06 B101-N2748-06 L1-0403-0301 B010-27900-09-30 B010-27900-09-36 B010-27900-09-48 19

MODEL NO.: CH2730SQ3-WM XX (30”) CH2736SQ3-WM XX (36”) CH2748SQ3-WM XX (48”)

20

CIRCUIT DIAGRAM

MODEL NO.: CH2730SQ3-XX and CH2730SQ3-WM XX (30”) CH2736SQ3-XX and CH2736SQ3-WM XX (36”) CH2748SQ3-WM XX (48”)

21

TROUBLE SHOOTING

Issue Possible Cause

After installation, both motors and lights are not working. The power is not on. The wire connection is not secure. The control panel is defective.

Solution

Make sure the circuit breaker and the unit’s power is ON. Use a voltage meter to check the power supply. Check and tighten wire connection. Replace the control panel. Lights are working, but motor(s) is not. The motor(s) is defective. The capacitor(s) is defective. Replace the motor(s). Replace the capacitor(s). The range hood is vibrating. The motor is working, but the lights are not working. The range hood is not venting out correctly. Cold air is coming into the home. The control panel is defective. The light wiring(s) is loose. The control panel or LED light driver is defective. The range hood is installed outside of the manufacture recommended clearance. There is no make-up air inside the house. Obstacle blocking the pipe work. The pipe size is smaller than the suggested pipe size. The pipe connection is not properly sealed. The damper is not properly installed or is missing from the installation. The damper is not installed. Replace the control panel The blower system is not secure. The turbine impeller/squirrel cage is not balanced. Hood is not secure in place. LED light fixture(s) is defective. Tighten the turbine impeller/squirrel cage and air chamber. Replace the turbine impeller/squirrel cage. Check the installation of hood, tighten the mounting bracket. Replace LED light fixture(s). Check wire continuity from Control Panel to LED Driver to LED light fixture(s). Replace the control panel or LED light driver. Adjust the clearance between the range hood and cook top to 26” to 30”. For Island range hood, the clearance between the range hood and cook top is 30” to 36”. Open the window to enhance the performance of the range hood by creating a sufficient make-up air. Remove all obstacles from the duct work. Change the ducting according to the manufacture suggestion. Check the pipe installation. Check the damper installation. Installing the damper will help eliminate air backflow. 22

WARRANTY WARRANTY CERTIFICATE

In order to obtain warranty service, you must provide proof of original purchase from a KOBE authorized Dealer. Please keep a copy of your original invoice as proof of purchase. TWO-YEAR LIMITED LABOR WARRANTY ON KOBE PREMIUM SERIES:

For two years from the date of your original invoice from a KOBE authorized dealer, we will repair any parts or components free of charge that failed due to manufacturing defects. KOBE reserves the right to replace, rather than repair the product free of charge at our sole discretion. It is your sole responsibility to ensure the product is readily accessible for the service technician to perform repairs.

The service technician will not, under any circumstance, remove, alter or modify any fixture built around and/or connected to the product to gain access to perform repairs. TWO-YEAR LIMITED PARTS WARRANTY ON KOBE PREMIUM SERIES:

For two years from the date of your original invoice from a KOBE authorized dealer, we will provide non-consumable replacement parts or components free of charge that failed due to manufacturing defects. Consumable parts such as light bulbs, filters, fuses, and oil cups are not covered by this warranty.

WHAT IS COVERED:

This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owner of this product. In Hawaii, Alaska and Canada, this warranty is limited. There may be additional shipping charges for parts and service technician travel costs in remote areas or locations 30 miles outside of KOBE authorized service area.

WHAT IS NOT COVERED:

1. Normal wear and tear, regular service and maintenance required for the product. 2. Consumable parts such as light bulbs, filters, fuses, and oil cups. 3. Chips, scratches or dents due to abuse or misuse of the product, use of corrosive and abrasive cleaning products. 4. Damages caused by accident, fire, flood and other Acts of God. 5. Services in remote areas or locations 30 miles outside of KOBE authorized service area. 6. Labor cost incurred in connection with the removal of range hood, and reinstallation of replacement range hood, nor does it cover any other contingent expenses. 7. Scratches inside the hood, back of the baffle filter, and inside the duct cover. 23

THIS WARRANTY WILL BE VOIDED BY:

1. Improper installation and failure to follow installation instructions. 2. Any repair, alteration, modification not authorized by KOBE. 3. Duct alteration, medication and connection. 4. Incorrect electric current, voltage or wiring. 5. Improper usage of the product such as commercial, outdoor or other usage other than residential indoor usage. 6. Purchasing this product from an unauthorized KOBE dealer. 7. Damaging the product due to negligence, misuse, abuse or accident. If we determine that the warranty exclusions listed above applies or if you fail to provide all necessary documentation for warranty service, you will be responsible for all expenses associated with the requested service, including parts, labor, shipping, travelling, and any other expense related to the service request.

TO REQUEST WARRANTY SERVICE, PLEASE CONTACT KOBE RANGE HOODS SERVICE CENTER: From the 48 contiguous states: Email (best): [email protected]

Phone: 1-626-775-8880 Toll Free: 1-877-BUY-KOBE (289-5623) From Alaska, Hawaii, and Canada: Email (best): [email protected]

Phone: 1-626-775-8880

24

WARRANTY INFORMATION FORM

Fill in the blanks and keep this paper with the

original invoice

in a safe place for future service purpose. 1. Date of purchase : ______________________________ 2. Model No.

3. Serial No.

: ______________________________ : ______________________________

For warranty service or spare parts purchase in US, contact:

KOBE Service Center Email (best): [email protected]

Phone: 1-626-775-8880 Toll Free: 1-877-BUY-KOBE (289-5623)

For warranty service or spare parts purchase in Canada, contact:

Email (best): [email protected]

Phone: 1-626-775-8880

25

11775 Clark Street KOBE Range Hoods Arcadia, CA 91006 USA

www.koberangehoods.com

This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country.

Using a KOBE hood overseas is at your own risk and will void your warranty.

Cette hotte KOBE est fabriquée pour usage aux États-Unis et au Canada seulement. Il n’est pas recommandé d’utiliser cette hotte à l’étranger puisque l’alimentation électrique pourrait ne pas être compatible et enfreindre le code de l’électricité de ce pays.

L’usage de la hotte KOBE à l’étranger est à votre propre risque et la garantie sera annulée.

Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE.UU. y CANADÁ. No recomendamos la utilización de esta campana en el extranjero debido a que la fuente de energía podría no ser compatible y podría violar el código eléctrico de dicho país.

Utilizar una campana KOBE en el extranjero será a su propio riesgo y anulará la garantía.

VER. 190718 Information subject to change without notice.

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF