5564039-YTG-A-1018 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONER / GAS HEAT 14 SEER – R-410A – 3 PHASE 3 THRU 5 NOMINAL TONS - 208/230V 50 THRU 125 MBH HEAT INPUT MODELS: PCG4*36 THRU 60 • Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Standard 1-Year limited parts warranty. Standard 5-Years limited compressor warranty. Lifetime gas heat exchanger warranty with registration. See limited warranty certificate in User’s Information Manual for details. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 6289 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5564039-YTG-A-1018 • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. 2 • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Filter Frame Kit - All 3 phase units include a filter frame kit, which is shipped inside the unit from production. Field installation is required. • Filters - All 3 phase units include an applicable number of 1" washable filters, which are shipped inside the unit from production. Field installation is required. Two filters are required for A base units. Three filters are required for B base units. Johnson Controls Unitary Products 5564039-YTG-A-1018 NOMENCLATURE PCG 1 4 2 A 3 24 4 050 5 1. Model Family PCG - packaged A/C with gas heat, PCE - packaged A/C with electric heat, PHE - packaged heat pump with electric heat 3 X 1 6 7 8 5. Gas Heating Input BTU/Hr x 1000 050 = 50,000 BTU/Hr. input, blank = electric heat 6. Voltage-Phase-Frequency 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 7. NOx Approval X = low-NOx, blank = not low-Nox 8. Generation Level 1 = first generation 9. Revision Level A = original release, B = second release A 9 2. Nominal Cooling Efficiency 4 = 14 SEER, 6 = 16 SEER, etc. 3. Cabinet Size A = small 35 x 51, B = large 45 x 51 4. Nominal Air Conditioning Cooling Capacity 24 = Nominal Capacity, etc. Examples: PCG4B421002X1A is a packaged A/C with gas heat, 14 SEER, 3-1/2 ton, large cabinet, three-stage heat, 100,000 BTU gas heat, 230 volt, three phase, low-NOx model (first generation, first release) COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER BLOWER MOTOR HIGH VOLTAGE CONTACTOR TXV PRESSURE SWITCH INDOOR COIL DRAFT INDUCER BLOWER INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY A0297-001 UNIT LIMITATIONS Model A36 A42 B48 B60 Unit Voltage 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Johnson Controls Unitary Products Min 187 187 187 187 Unit Limitations Applied Voltage Max 252 252 252 252 Outdoor DB Temp Max (°F) 125 125 125 125 3 5564039-YTG-A-1018 ACCESSORIES • Propane Conversion Kit (S1-1NP0703, S1-1NP0704) - Kit includes burner orifices, gas valve conversion and installation instructions necessary to field convert unit from natural gas to propane. • Economizer for Downflow Applications (S1-2EE04710024, S1-2EE04710124) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor, and barometric relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Economizer for Horizontal Applications (S1-2EE04710224, S1-2EE04710324) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood and dry bulb sensor. Separate field accessories of single enthalpy and dual enthalpy are also available. • Barometric Relief Hood (S1-1RD0501) - Used in conjunction with a horizontal economizer, the Barometric Relief Hood helps to equalize the building pressure that is caused by the fresh air that is introduced through the economizer fresh air hood. • Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • Duct/Unit Mount CO2 Kit (S1-2AQ04700924) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Wall Mount CO2 Kit (S1-2AQ04701024) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) Outdoor supply air temperature sensor kit used with economizers. 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. • Loss of Charge Switch (S1-2LC00024) - Kit provides Loss of Charge sensor and wiring to provide safe shutdown of compressor. • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PCG4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCG4 price pages for more details. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Filter/Frame Kit (Kit provided) (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. • Thermostat - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with the York Hx™ Touchscreen Thermostat available through Source1. For more information, see the thermostat section of the Product Equipment Catalog. • Filter (S1-02647812000) - Washable 1” filter. Two filters are required for A base units. Three filters are required for B base units. Washable filters are included inside shipped units for field installation. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through • Low Ambient Kit (S1-2LA04701024) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. 4 • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. Johnson Controls Unitary Products 5564039-YTG-A-1018 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powderpainted steel, certified at 1000 hours salt spray test per ASTMB117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV's) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40ºF. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule. 5 5564039-YTG-A-1018 PHYSICAL DATA COMPONENT NOMINAL TONNAGE AHRI Cooling Performance Gross Capacity @ AHRI A point (MBH) AHRI net capacity (MBH) EER SEER Nominal CFM System power (KW) Refrigerant type Refrigerant charge (lb-oz) AHRI Gas Heat Performance Heating model Heat input (K Btu) Heat output (K Btu) AFUE% No. burners No. stages Temperature Rise Range (°F) Max. Static Pressure w.c. Max. Outlet Air Temp. (°F) Gas piping connection (in.) Dimensions (inches) Length Width Height Operating WT. (lbs.) Compressors Type Outdoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Indoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Refrigerant control Outdoor Fan Data Fan diameter (Inch) Type Drive type No. speeds Motor HP each RPM Nominal total CFM Direct Drive Indoor Fan Data Fan Size (Inch) Type Motor HP each RPM Frame size Filter Filter Size Quantity - Size 6 50 50.0 40 81.0 2 1 35-65 394 PCG4A36 3.0 PCG4A42 3.5 37.2 34.6 11.0 14.0 1200 3.2 R410A 8-8 43.5 41.0 11.0 14.0 1400 3.8 R410A 9-4 75 100 75.0 100.0 60 80 81.0 81.0 3 4 1 1 40-70 0.5 180 1/2 51-1/4 35-3/4 47 401 405 75 100 75.0 100.0 60 80 81.0 81.0 3 4 1 1 40-70 0.5 180 1/2 51-1/4 35-3/4 49 441 443 MODELS PCG4B48 4.0 PCG4B60 5.0 47.7 45.5 11.0 14.0 1600 4.2 R410A 11-3 65 65.0 52 81.0 2 1 460 55.0 52.5 11.0 14.0 2000 4.8 R410A 12-0 100 100.0 80 81.0 3 1 40-70 0.5 180 1/2 125 125.0 100 81.0 4 1 51-1/4 45-3/4 49 468 473 65 65.0 52 81.0 2 1 477 100 100.0 80 81.0 3 1 40-70 0.5 180 1/2 51-1/4 45-3/4 51 481 Scroll Scroll Scroll Scroll 15.1 2 22 3/8 Interlaced 16.9 2 22 3/8 Interlaced 19.5 2 22 3/8 Interlaced 21.5 2 22 3/8 Interlaced 4.6 3 16 3/8 Interlaced TXV 4.6 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 24 Prop Direct 1 1/4 850 2400 24 Prop Direct 1 1/4 850 2400 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 11 x 10 Centrifugal 1/2 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 1 1200 Max 48 A B B A 3/4 125 125.0 100 81.0 4 1 488 Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable filters. For internal filter use, a filter rack kit is included with all three phase models. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. Johnson Controls Unitary Products 5564039-YTG-A-1018 COOLING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. PCG4A36 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 36.0 38.3 55 / 45 S.C. 34.5 30.6 K.W. 1.82 1.83 T.C. 34.6 36.4 65 / 55 S.C. 33.2 29.8 K.W. 2.01 2.02 T.C. 33.2 34.6 75 / 63 S.C. 32.0 28.9 K.W. 2.20 2.20 T.C. 31.7 32.6 85 / 69 S.C. 30.4 26.9 K.W. 2.46 2.44 T.C. 30.1 30.6 95 / 75 S.C. 28.8 25.0 K.W. 2.72 2.67 T.C. 29.0 28.3 105 / 83 S.C. 27.5 23.9 K.W. 2.91 2.92 T.C. 27.9 26.0 115 / 89 S.C. 26.3 22.9 K.W. 3.11 3.16 T.C. 26.8 23.8 125 / 95 S.C. 25.1 21.9 K.W. 3.30 3.39 1000 75 62 40.3 27.6 1.83 37.4 26.0 2.02 34.5 24.5 2.21 32.2 23.3 2.47 29.8 22.2 2.73 27.8 20.9 2.95 25.9 19.6 3.17 24.0 18.3 3.39 80 67 44.9 27.9 1.83 42.6 26.8 2.03 40.3 25.7 2.22 37.8 24.6 2.48 35.3 23.4 2.74 32.8 21.8 2.96 30.4 20.3 3.19 28.0 18.7 3.41 80 72 48.1 22.6 1.85 46.1 21.6 2.04 44.0 20.7 2.23 41.2 19.3 2.49 38.4 17.9 2.74 36.1 16.9 2.97 33.9 15.9 3.20 31.7 14.9 3.42 80 57 38.9 37.1 1.89 37.3 35.6 2.09 35.7 34.1 2.28 34.0 32.4 2.53 32.3 30.8 2.79 31.1 29.4 2.95 30.0 28.1 3.10 28.9 26.8 3.25 80 62 40.4 33.8 1.90 38.3 32.9 2.09 36.3 32.0 2.28 34.0 30.3 2.53 31.7 28.6 2.77 29.6 27.1 3.01 27.4 25.8 3.24 25.3 24.4 3.47 1200 75 62 42.1 29.9 1.90 39.4 28.5 2.09 36.6 27.2 2.28 33.8 25.8 2.54 31.0 24.3 2.80 28.9 22.9 3.02 26.8 21.6 3.24 24.8 20.2 3.46 80 67 46.8 30.2 1.91 44.2 28.9 2.10 41.7 27.7 2.30 38.9 26.5 2.55 36.2 25.3 2.81 33.8 23.8 3.04 31.4 22.3 3.26 29.0 20.9 3.48 80 72 49.8 23.9 1.92 47.9 23.4 2.11 46.1 22.9 2.30 42.8 21.1 2.56 39.6 19.3 2.82 37.1 18.2 3.05 34.7 17.2 3.27 32.3 16.2 3.49 80 57 41.8 39.6 1.97 40.0 37.9 2.16 38.1 36.1 2.36 36.3 34.5 2.61 34.5 32.8 2.87 33.3 31.3 2.98 32.1 29.9 3.10 31.0 28.5 3.21 80 62 42.5 37.1 1.97 40.2 36.1 2.16 37.9 35.2 2.36 35.4 33.7 2.61 32.8 32.2 2.87 30.8 30.4 3.10 28.9 28.6 3.32 26.9 26.9 3.55 1400 75 62 43.9 32.2 1.98 41.3 31.0 2.17 38.7 29.9 2.36 35.4 28.2 2.61 32.1 26.5 2.87 29.9 25.0 3.10 27.8 23.5 3.32 25.6 22.1 3.54 80 67 48.8 32.5 1.99 45.9 31.1 2.18 43.1 29.7 2.37 40.1 28.4 2.63 37.1 27.2 2.88 34.7 25.8 3.11 32.3 24.4 3.33 30.0 23.1 3.55 80 72 51.5 25.1 1.99 49.8 25.1 2.19 48.2 25.0 2.38 44.5 22.8 2.63 40.8 20.7 2.89 38.1 19.6 3.12 35.5 18.5 3.35 33.0 17.4 3.57 80 67 51.8 34.4 2.38 48.9 32.8 2.62 46.0 31.3 2.87 42.7 28.5 3.18 39.3 25.8 3.48 34.9 24.5 3.90 30.7 23.1 4.30 26.5 21.8 4.70 80 72 57.3 28.7 2.38 54.1 27.5 2.61 51.0 26.2 2.84 47.6 24.5 3.15 44.1 22.8 3.47 39.4 20.9 3.90 34.7 19.0 4.31 30.1 17.2 4.73 80 57 46.5 45.5 2.42 44.4 43.7 2.55 42.2 41.9 2.67 39.3 39.2 2.98 36.5 36.5 3.29 32.5 32.5 3.72 28.7 28.7 4.14 24.9 24.9 4.57 80 62 48.6 42.1 2.44 45.6 40.5 2.68 42.6 38.8 2.93 40.0 36.1 3.24 37.4 33.3 3.54 33.0 30.3 3.97 28.8 27.4 4.38 24.5 24.5 4.79 1400 75 62 48.5 36.2 2.43 45.6 34.4 2.66 42.6 32.7 2.89 39.3 31.0 3.20 35.9 29.4 3.51 31.5 26.9 3.94 27.2 24.4 4.35 22.9 22.0 4.76 80 67 53.7 37.0 2.45 50.5 35.3 2.70 47.4 33.6 2.94 43.8 31.2 3.24 40.2 28.9 3.54 35.5 27.0 3.97 30.9 25.2 4.37 26.4 23.3 4.78 80 72 59.6 30.7 2.47 56.1 29.2 2.71 52.5 27.6 2.94 48.8 25.9 3.26 45.1 24.1 3.57 40.0 22.1 3.99 35.0 20.1 4.41 30.1 18.1 4.82 80 57 49.4 47.8 2.50 46.6 45.5 2.73 43.8 43.3 2.97 40.7 40.4 3.28 37.6 37.6 3.59 33.3 33.3 4.01 29.2 29.2 4.43 25.1 25.1 4.84 80 62 50.2 45.0 2.52 47.0 43.2 2.76 43.9 41.4 3.00 41.8 37.7 3.30 39.7 33.9 3.60 34.8 31.0 4.03 30.1 28.2 4.45 25.4 25.4 4.86 1600 75 62 50.2 38.5 2.51 47.0 36.4 2.74 43.7 34.3 2.97 40.1 32.8 3.28 36.5 31.3 3.59 31.8 28.4 4.01 27.3 25.6 4.42 22.8 22.8 4.83 80 67 55.5 39.6 2.53 52.1 37.7 2.77 48.7 35.9 3.01 44.9 33.9 3.31 41.1 32.0 3.60 36.1 29.5 4.03 31.1 27.2 4.45 26.2 24.8 4.87 80 72 61.9 32.6 2.56 58.0 30.8 2.80 54.1 29.0 3.04 50.0 27.3 3.36 46.0 25.5 3.67 40.6 23.3 4.09 35.3 21.2 4.50 30.1 19.1 4.91 COOLING PERFORMANCE DATA - 3.5 TON PACKAGED UNIT MODEL NO. PCG4A42 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 43.7 46.9 55 / 45 S.C. 43.1 39.2 K.W. 2.35 2.36 T.C. 42.2 44.1 65 / 55 S.C. 41.9 37.7 K.W. 2.36 2.61 T.C. 40.6 41.3 75 / 63 S.C. 40.6 36.3 K.W. 2.38 2.86 T.C. 38.0 38.2 85 / 69 S.C. 38.0 34.5 K.W. 2.69 3.17 T.C. 35.4 35.1 95 / 75 S.C. 35.4 32.7 K.W. 3.00 3.48 T.C. 31.7 31.2 105 / 83 S.C. 31.7 29.6 K.W. 3.44 3.90 T.C. 28.2 27.4 115 / 89 S.C. 28.2 26.7 K.W. 3.86 4.31 T.C. 24.7 23.7 125 / 95 S.C. 24.7 23.7 K.W. 4.29 4.71 Johnson Controls Unitary Products 1200 75 62 46.8 33.9 2.36 44.1 32.5 2.59 41.4 31.0 2.82 38.4 29.3 3.13 35.4 27.6 3.44 31.2 25.4 3.86 27.1 23.3 4.28 23.0 21.2 4.69 7 5564039-YTG-A-1018 COOLING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. PCG4B48 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 50.7 55.0 55 / 45 S.C. 48.2 44.8 K.W. 2.48 2.52 T.C. 48.0 52.0 65 / 55 S.C. 44.3 43.2 K.W. 2.76 2.79 T.C. 45.4 49.0 75 / 63 S.C. 40.3 41.7 K.W. 3.04 3.06 T.C. 42.9 45.4 85 / 69 S.C. 38.3 39.8 K.W. 3.41 3.42 T.C. 40.4 41.8 95 / 75 S.C. 36.4 38.0 K.W. 3.79 3.79 T.C. 36.7 37.6 105 / 83 S.C. 32.3 34.7 K.W. 4.30 4.30 T.C. 33.1 33.6 115 / 89 S.C. 28.4 31.6 K.W. 4.80 4.80 T.C. 29.5 29.5 125 / 95 S.C. 24.5 28.4 K.W. 5.30 5.29 1400 75 62 54.4 38.3 2.51 51.2 36.7 2.79 48.1 35.0 3.06 44.9 33.2 3.42 41.7 31.4 3.78 37.5 29.7 4.29 33.3 28.0 4.79 29.2 26.4 5.30 80 67 59.4 38.5 2.54 57.1 37.1 2.81 54.9 35.7 3.08 51.3 33.7 3.44 47.7 31.8 3.80 43.5 30.0 4.32 39.4 28.4 4.83 35.3 26.7 5.33 80 72 65.3 30.4 2.56 62.8 29.6 2.83 60.3 28.7 3.11 56.4 27.3 3.46 52.4 25.9 3.82 47.8 23.9 4.34 43.4 21.9 4.85 39.0 19.9 5.35 80 57 53.0 49.3 2.56 50.3 46.3 2.83 47.5 43.4 3.10 44.8 41.4 3.47 42.1 39.4 3.85 38.1 34.3 4.36 34.1 29.4 4.87 30.2 24.5 5.37 80 62 56.8 48.2 2.59 53.6 46.6 2.85 50.4 45.1 3.12 46.6 42.4 3.49 42.7 39.7 3.85 38.4 36.1 4.36 34.3 32.5 4.86 30.1 29.0 5.36 1600 75 62 56.1 41.0 2.58 52.9 39.3 2.85 49.6 37.6 3.12 46.1 35.7 3.48 42.6 33.8 3.83 38.0 31.1 4.35 33.6 28.6 4.86 29.2 26.0 5.36 80 67 61.2 40.7 2.61 58.7 39.4 2.88 56.2 38.1 3.14 52.5 36.3 3.50 48.7 34.5 3.86 44.3 32.6 4.38 40.0 30.7 4.89 35.7 28.8 5.39 80 72 67.2 31.9 2.62 64.4 30.8 2.89 61.6 29.7 3.17 57.7 28.4 3.53 53.8 27.0 3.89 48.9 24.9 4.41 44.2 22.9 4.91 39.5 20.9 5.41 80 57 55.4 50.3 2.64 52.5 48.4 2.90 49.6 46.4 3.16 46.7 44.4 3.53 43.9 42.4 3.90 39.5 36.4 4.43 35.2 30.5 4.93 30.9 24.6 5.44 80 62 58.6 51.5 2.65 55.2 50.0 2.92 51.8 48.4 3.18 47.7 44.9 3.55 43.6 41.4 3.91 39.2 37.4 4.42 35.0 33.5 4.92 30.7 29.6 5.42 1800 75 62 57.9 43.6 2.64 54.5 41.9 2.91 51.1 40.2 3.18 47.2 38.2 3.54 43.4 36.2 3.89 38.6 32.6 4.41 33.8 29.1 4.92 29.1 25.6 5.42 80 67 63.1 42.9 2.67 60.3 41.7 2.94 57.5 40.5 3.21 53.6 38.9 3.57 49.7 37.3 3.92 45.1 35.1 4.44 40.6 33.0 4.95 36.1 31.0 5.45 80 72 69.1 33.4 2.68 66.0 32.1 2.95 62.9 30.8 3.23 59.1 29.4 3.59 55.2 28.1 3.95 50.0 26.0 4.47 45.0 23.9 4.97 40.0 21.9 5.47 80 67 73.0 43.7 3.00 69.7 43.2 3.31 66.4 42.7 3.63 61.8 40.5 4.04 57.1 38.2 4.44 51.1 36.0 5.01 45.3 33.8 5.57 39.5 31.6 6.12 80 72 79.5 36.0 3.03 75.7 34.9 3.35 72.0 33.7 3.67 67.1 31.6 4.07 62.3 29.4 4.48 55.2 26.7 5.05 48.3 24.0 5.60 41.4 21.3 6.15 80 57 70.4 66.7 3.15 66.2 62.8 3.46 62.1 59.0 3.78 58.7 56.2 4.19 55.3 53.5 4.61 52.5 50.0 5.22 49.8 46.6 5.80 47.1 43.1 6.39 80 62 70.4 57.0 3.17 66.4 55.9 3.48 62.5 54.7 3.79 57.8 52.2 4.21 53.0 49.7 4.62 47.6 44.0 5.19 42.3 38.4 5.75 36.9 32.9 6.30 1800 75 62 69.3 48.8 3.18 65.1 46.7 3.49 60.9 44.7 3.80 56.6 43.1 4.21 52.3 41.5 4.62 45.6 37.3 5.19 39.0 33.3 5.74 32.5 29.2 6.30 80 67 74.8 46.3 3.21 71.0 45.4 3.52 67.1 44.5 3.84 62.3 42.5 4.24 57.5 40.4 4.65 51.0 37.8 5.22 44.7 35.3 5.77 38.3 32.8 6.32 80 72 80.8 37.1 3.24 76.5 35.7 3.56 72.2 34.3 3.88 67.4 32.8 4.28 62.6 31.2 4.68 55.2 28.1 5.25 47.9 25.0 5.80 40.7 21.9 6.35 80 57 72.7 70.1 3.36 68.4 65.3 3.68 64.0 60.6 3.99 60.0 57.5 4.41 56.1 54.4 4.82 52.8 50.4 5.40 49.7 46.6 5.96 46.6 42.7 6.52 80 62 71.7 59.2 3.38 67.5 58.3 3.69 63.2 57.5 4.00 58.4 55.0 4.42 53.7 52.5 4.83 47.9 45.8 5.40 42.3 39.4 5.95 36.8 32.9 6.51 2000 75 62 70.5 51.4 3.38 65.9 48.9 3.69 61.4 46.3 4.01 57.0 45.1 4.42 52.5 43.8 4.83 45.2 38.3 5.40 38.1 33.1 5.95 31.0 27.8 6.50 80 67 76.6 48.8 3.42 72.3 47.6 3.73 67.9 46.3 4.04 62.9 44.5 4.45 57.9 42.6 4.86 50.9 39.7 5.42 44.0 36.9 5.97 37.2 34.1 6.52 80 72 82.2 38.2 3.45 77.4 36.5 3.77 72.5 34.9 4.08 67.7 33.9 4.48 62.9 33.0 4.88 55.1 29.5 5.45 47.5 26.0 6.00 39.9 22.6 6.55 COOLING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. PCG4B60 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 68.0 69.1 55 / 45 S.C. 63.3 54.8 K.W. 2.93 2.97 T.C. 64.1 65.4 65 / 55 S.C. 60.3 53.4 K.W. 3.25 3.27 T.C. 60.2 61.8 75 / 63 S.C. 57.4 52.0 K.W. 3.56 3.58 T.C. 57.4 57.1 85 / 69 S.C. 55.0 49.4 K.W. 3.98 4.00 T.C. 54.5 52.4 95 / 75 S.C. 52.6 46.9 K.W. 4.40 4.42 T.C. 52.1 47.2 105 / 83 S.C. 49.5 42.1 K.W. 5.03 4.99 T.C. 49.8 42.2 115 / 89 S.C. 46.6 37.5 K.W. 5.65 5.54 T.C. 47.5 37.1 125 / 95 S.C. 43.6 32.8 K.W. 6.27 6.09 8 1600 75 62 68.1 46.2 2.97 64.3 44.6 3.28 60.5 43.1 3.59 56.2 41.1 4.01 52.0 39.2 4.42 45.9 36.3 4.99 40.0 33.4 5.54 34.1 30.6 6.09 Johnson Controls Unitary Products 5564039-YTG-A-1018 81,77233$1(/ &251(53267 ,1'225&2,/ &2,/*8$5' +,*+92/7$*( 23(1,1*´ & +,*+92/7$*( 23(1,1*´ &20%867,21$,5,17$.( +($7(;&+$1*(5$&&(663$1(/ &2035(6625 $&&(663$1(/ )/8((;+$867+22' &21'(16$7( '5$,1 %/2:(5 $&&(66 3$1(/ $ % /2:92/7$*(23(1,1*´ *$66833/<+2/(´:,7+ *5200(723(1,1*2)´ &21752/+($7 $&&(663$1(/ $ UNIT DIMENSIONS Model A36 A42 B48 B60 A 51-1/4 51-1/4 51-1/4 51-1/4 Dimensions B 35-3/4 35-3/4 45-3/4 45-3/4 C 47 49 49 51 UNIT CLEARANCES1,2 Direction Top3 Side Opposite Ducts Duct Panel 1. 2. 3. 4. Distance (in.) 36 36 0 Direction Power Entry (Right Side) Left Side Bottom4 Distance (in.) 36 24 1 A 1" clearance must be provided between any combustible material and the supply air duct work. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. Units may be installed on combustible floors made from class A, B or C roof covering materials. Johnson Controls Unitary Products 9 5564039-YTG-A-1018 INDOOR BLOWER SPECIFICATIONS Motor Model HP 1/3 1/2 1/3 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 24050 24075 30050 30075 36050 36075 36100 42075 42100 48065 48100 48125 60065 60100 60125 RPM Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable EFF. 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 SF 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Frame 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 SOUND PERFORMANCE Model (Tons) Sound Rating1 dB (A) A36 A42 B48 B60 74 74 74 76 125 58.5 63.5 63.5 72.3 250 61.8 63.9 63.9 65.0 Octave Band Centerline Frequency (Hz) 500 1000 2000 65.4 66.5 60.7 62.3 65.0 64.0 62.3 65.0 64.0 63.9 64.0 60.0 4000 54.8 54.1 54.1 55.5 8000 49.8 46.6 46.6 49.0 1. Rated in accordance with AHRI Standard 270. ELECTRICAL DATA Model 36050, 36075 36100 42075, 42100 48065, 48100, 48125 60065, 60100, 60125 Compressor Voltage 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 OD Fan Motor Supply Blower Motor RLA LRA MCC FLA FLA 10.4 10.4 13.5 13.7 16.0 73.0 73.0 88.0 83.1 110.0 16.3 16.3 21.1 21.4 24.9 1.3 1.3 1.3 1.7 1.7 3.8 5.4 5.4 5.4 7.0 MCA1 (Amps) 18.1 18.1 23.6 24.2 28.7 Max Fuse2/ Breaker3 Size (Amps) 25 25 35 35 40 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. 10 Johnson Controls Unitary Products 5564039-YTG-A-1018 "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT Y "B" X A0295-001-TG WEIGHTS AND DIMENSIONS Model Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 36050 36075 36100 42075 Shipping 399 406 410 446 Operating 394 401 405 441 X 28 28 28 28 Y 15 15 15 15 A 141 135 139 145 B 107 115 113 112 C 94 103 99 99 D 78 74 80 85 42100 48065 48100 48125 60065 60100 60125 448 465 473 478 482 486 493 443 460 468 473 477 481 488 28 28 28 28 29 28 27 15 15 15 15 15 15 15 148 189 169 164 174 177 151 110 116 139 145 142 140 167 96 93 115 124 124 117 141 89 117 100 95 92 102 84 Johnson Controls Unitary Products 11 5564039-YTG-A-1018 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION Model External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 851 790 730 674 1042 995 942 889 1126 1084 1032 980 1186 1144 1097 1049 1389 1345 1305 1262 1090 1046 993 941 1126 1084 1032 980 1186 1144 1097 1049 1222 1179 1133 1086 1389 1345 1305 1262 1217 1178 1134 1082 1293 1251 1208 1163 1423 1386 1346 1302 1530 1495 1454 1414 1810 1757 1705 1653 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 1003 1180 1259 1314 1506 1225 1259 1314 1348 1506 1342 1425 1554 1658 1966 0.2 SCFM 952 1133 1209 1271 1471 1174 1209 1271 1306 1471 1302 1368 1503 1599 1914 0.3 SCFM 904 1085 1166 1229 1403 1131 1166 1229 1259 1403 1260 1332 1465 1588 1862 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 1315 1436 1458 1573 1966 1436 1544 1573 1681 1935 1046 1295 1620 1798 2146 1620 1694 1798 1835 2146 1620 1798 1266 1382 1406 1523 1914 1382 1492 1523 1640 1887 1009 1250 1564 1722 2085 1564 1630 1722 1758 2085 1564 1722 1229 1342 1365 1484 1862 1342 1455 1484 1599 1834 980 1213 1517 1669 2025 1517 1580 1669 1703 2025 1517 1669 1194 1304 1327 1445 1810 1304 1416 1445 1557 1788 946 1172 1466 1620 1960 1466 1530 1620 1653 1960 1466 1620 1156 1262 1286 1408 1757 1262 1376 1408 1517 1743 915 1133 1418 1572 1872 1418 1482 1572 1604 1872 1418 1572 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 60065 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 60100 Medium (3) Medium/High (4) High (5) Continued on next page. 1922 2001 2146 1073 1329 2054 2195 2445 1730 1858 2054 2195 2445 1863 1952 2085 1043 1292 1998 2144 2388 1682 1807 1998 2144 2388 1804 1890 2025 1009 1250 1934 2098 2306 1628 1749 1934 2098 2306 1754 1839 1960 988 1223 1890 2049 2293 1592 1710 1890 2049 2293 1724 1820 1872 963 1192 1843 2003 2235 1552 1667 1843 2003 2235 36050 36075 36100 42075 42100 48065 48100 48125 12 Motor Speed 0.8 SCFM 633 834 928 998 1216 888 928 998 1036 1216 1034 1113 1257 1373 1.0 SCFM 551 724 824 896 1124 782 824 896 936 1124 938 1013 1167 1291 1117 1220 1244 1367 1705 1220 1336 1367 1478 1701 878 1087 1360 1527 1862 1360 1430 1527 1558 1862 1360 1080 1179 1203 1327 1653 1179 1294 1327 1436 1651 844 1045 1308 1480 1798 1308 1380 1480 1511 1798 1308 1600 1036 1131 1155 1279 1600 1131 1248 1279 1393 1591 779 964 1206 1413 1735 1206 1292 1413 1442 1735 1206 1496 948 1035 1059 1183 1496 1035 1156 1183 1307 1471 649 802 1002 1280 1609 1002 1116 1280 1304 1609 1002 1527 1658 1742 1862 941 1165 1801 1955 2178 1517 1629 1801 1955 2178 1480 1612 1696 1798 917 1136 1757 1883 2129 1479 1589 1757 1883 2129 1413 1559 1651 1735 892 1105 1710 1868 2077 1439 1546 1710 1868 2077 1280 1453 1561 1609 842 1043 1616 1838 1973 1359 1460 1616 1838 1973 Johnson Controls Unitary Products 5564039-YTG-A-1018 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued) 1. 2. 3. 4. 5. Model Motor Speed 60125 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 2063 2130 2195 2275 2445 0.2 SCFM 2008 2084 2144 2252 2388 0.3 SCFM 1943 2032 2098 2169 2306 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1899 1851 1809 1763 1983 1927 1951 1860 2049 2003 1955 1883 2154 2112 2065 1989 2293 2235 2178 2129 0.8 SCFM 1717 1815 1868 1976 2077 1.0 SCFM 1625 1725 1838 1950 1973 0.8 SCFM 1.0 SCFM Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION Model External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 861 807 757 700 Low (1) 0.1 SCFM 1008 0.2 SCFM 962 0.3 SCFM 916 Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 1190 1262 1324 1517 1231 1270 1317 1358 1517 1340 1409 1527 1663 1930 1332 1457 1451 1568 1978 1455 1566 1148 1223 1282 1475 1186 1225 1286 1317 1475 1299 1368 1492 1585 1892 1295 1419 1412 1524 1937 1414 1532 1106 1181 1245 1447 1146 1189 1245 1275 1447 1264 1334 1470 1594 1853 1263 1376 1371 1491 1891 1379 1492 1055 1137 1202 1400 1103 1140 1198 1238 1400 1224 1291 1419 1601 1805 1222 1340 1339 1464 1837 1335 1455 1008 1091 1161 1357 1069 1098 1151 1197 1357 1182 1253 1385 1521 1760 1185 1299 1296 1425 1785 1294 1416 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 48065 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 48100 Medium (3) Medium/High (4) High (5) Continued on next page. 1565 1675 1946 1032 1272 1611 1892 2131 1598 1663 1789 1931 2131 1530 1641 1909 999 1236 1574 1777 2058 1548 1612 1733 1814 2058 1491 1606 1863 970 1204 1518 1771 1998 1502 1568 1670 1808 1998 1458 1578 1815 938 1165 1494 1701 1949 1454 1522 1650 1736 1949 1419 1535 1771 910 1129 1439 1639 1892 1410 1476 1596 1673 1892 36050 36075 36100 42075 Motor Speed 42100 Johnson Controls Unitary Products 955 1044 1112 1318 1030 1046 1110 1148 1318 1182 1201 1343 1480 1696 1148 1253 1257 1383 1725 1254 914 994 1067 1275 977 1008 1064 1105 1275 1097 1173 1299 1440 1625 1110 1215 1211 1345 1656 1212 650 863 952 1018 1232 912 960 1024 1057 1232 1049 1128 1250 1400 1553 1063 1160 1165 1296 1604 1160 550 761 868 920 1146 781 866 943 961 1146 953 1038 1152 1320 1409 967 1051 1072 1200 1502 1056 1372 1381 1495 1721 879 1081 1405 1617 1840 1362 1422 1578 1650 1840 1333 1336 1455 1654 843 1037 1357 1565 1788 1307 1370 1535 1597 1788 1280 1290 1412 1595 808 968 1266 1489 1728 1251 1297 1483 1519 1728 1174 1198 1326 1477 737 829 1083 1336 1608 1139 1152 1379 1362 1608 13 5564039-YTG-A-1018 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION (Continued) Model 48125 60065 60100 60125 1. 2. 3. 4. 5. 14 Motor Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 1598 1766 1912 2105 2131 1026 1263 1987 2114 2369 1655 1766 1987 2114 2369 0.2 SCFM 1548 1703 1875 2014 2058 999 1230 1933 2050 2308 1612 1720 1933 2050 2308 0.3 SCFM 1502 1656 1805 2006 1998 989 1192 1861 2047 2249 1596 1667 1861 2047 2249 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 1973 2024 2123 2191 2369 1924 1983 2075 2154 2308 1905 1937 2019 2117 2249 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1454 1410 1362 1307 1611 1566 1518 1469 1787 1750 1713 1672 1931 1898 1845 1793 1949 1892 1840 1788 950 907 907 886 1165 1167 1101 1099 1817 1820 1715 1725 1974 1899 1889 1920 2183 2126 2088 2034 1531 1461 1462 1429 1629 1632 1539 1537 1817 1820 1715 1725 1974 1899 1889 1920 2183 2126 2088 2034 1826 1889 1970 2075 2183 1743 1886 1978 2002 2126 1744 1843 1862 1995 2088 1703 1799 1849 2028 2034 0.8 SCFM 1251 1419 1636 1739 1728 862 1071 1651 1866 1990 1391 1498 1651 1866 1.0 SCFM 1139 1319 1564 1631 1608 816 1015 1504 1758 1902 1316 1421 1504 1758 1990 1660 1759 1804 1974 1990 1902 1574 1679 1714 1866 1902 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5564039-YTG-A-1018 ADDITIONAL STATIC RESISTANCE Size (Tons) A36 (3.0) A42 (3.5) B48 (4.0) B60 (5.0) CFM 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 BOTTOM DUCT DIMENSIONS (Inches) 1 Wet Indoor Coil Economizer 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 Filter/Frame Kit 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. ' 9,(:/22.,1*83 $7%277202)81,7 ´ ´ & 5(7851 $,5'8&7 $ +2/(´ ( ZLWK´JURPPHW RSHQLQJIRUJDVSLSH % +2/(´ IRUKLJK YROWDJH 6833/< $,5'8&7 $ +2/(´ IRU ORZYROWDJH ) Model 36, 42 48, 60 A 10 14 B 21.5 13.5 $ C 5 5 D 4.5 3.5 E 47.5 47.5 F 32 42 REAR DUCT DIMENSIONS (Inches) 127(6HH)LJXUHWLWOHG³8QLW'LPHQVLRQV´IRUVLGHKROHVL]HVRI HOHFWULFDODQGJDVOLQHV 5(7851 $,5'8&7 6833/< $,5'8&7 $ Model 36, 42 48, 60 Johnson Controls Unitary Products $ % A 9.6 13.6 $ B 22 14 15 5564039-YTG-A-1018 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A032 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE TO GAS SUPPLY LINE 16 CONTROL WIRING TO INDOOR THERMOSTAT A0325-001 Johnson Controls Unitary Products 5564039-YTG-A-1018 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO GAS SUPPLY LINE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT Johnson Controls Unitary Products SUPPLY AIR DUCT A0326-001 17 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2018 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5564039-YTG-A-1018 Supersedes: 5006143-YTG-F-1017
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement