5564033-YTG-A-0918 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONER / GAS HEAT 14 SEER – R-410A – 1 PHASE 2 THRU 5 NOMINAL TONS - 208/230V 50 THRU 125 MBH HEAT INPUT MODELS: PCG4*24 THRU 60 • Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Extended 10-Years limited parts and compressor warranty Lifetime gas heat exchanger warranty with registration. * Extended warranty requires online registration within 90 days of purchase for replacement or closing for new home purchase. See limited warranty certificate in User’s Information Manual for details. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the indoor coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insures less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5564033-YTG-A-0918 • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • Pressure Switches - A high pressure switch is standard in all units. It is an automatic reset switch. When discharge pressure reaches 650 psi, the compressor will de-energize until pressure reaches 450 psi. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Outdoor Coil Grille - All models utilize a stamped slotted design that provides superior impact protection against small objects during transit and after installation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improve heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable and durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Loss of Charge Sensor (S1-2LC00024) - Kit provides Loss of Charge sensor and wiring to provide safe shutdown of compressor. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PHE4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCE4 price pages for more details. • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. 2 Johnson Controls Unitary Products 5564033-YTG-A-0918 NOMENCLATURE PCG 4 A 24 50 2 X 1 A 1 2 3 4 5 6 7 8 9 1. Model Family 5. Gas Heating Input BTU/Hr x 1000 PCG - packaged A/C with gas heat, 050 = 50,000 BTU/Hr. input, blank = electric heat PHG - packaged heat pump with gas heat, 6. Voltage-Phase-Frequency PCE - packaged A/C with electric heat, 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 PHE - packaged heat pump with electric heat 2. Nominal Cooling Efficiency 7. NOx Approval 4 = 14 SEER, 6 = 16 SEER, etc. X = low-NOx, blank = not low-Nox 3. Cabinet Size 8. Generation Level A = small 35 x 51, B = large 45 x 51 1 = first generation 4. Nominal Air Conditioning Cooling Capacity BTUx1000 9. Revision Level 24 = 24,000 BTU, etc. A = original release, B = second release Examples: PCG4B421002X1A is a packaged A/C with gas heat, 14 SEER, 3-1/2 ton, large cabinet, single-stage heat, 100,000 BTU gas heat, 230 volt, single phase, low-NOx model (first generation, first release) COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER BLOWER MOTOR HIGH VOLTAGE CONTACTOR TXV PRESSURE SWITCH INDOOR COIL DRAFT INDUCER BLOWER INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY A0297-001 UNIT LIMITATIONS Model A24 A30 A36 A42 B48 B60 Unit Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Johnson Controls Unitary Products Min 187 187 187 187 187 187 Unit Limitations Applied Voltage Max 252 252 252 252 252 252 Outdoor DB Temp Max (°F) 125 125 125 125 125 125 3 5564033-YTG-A-0918 ACCESSORIES • Propane Conversion Kit (S1-1NP0703, S1-1NP0704) - Kit includes burner orifices, gas valve conversion and installation instructions necessary to field convert unit from natural gas to propane. • Economizer for Downflow Applications (S1-2EE04710024, S1-2EE04710124) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor, and barometric relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Economizer for Horizontal Applications (S1-2EE04710224, S1-2EE04710324) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor. Separate field accessories of single enthalpy and dual enthalpy are also available. • Barometric Relief Hood (S1-1RD0501) - Used in conjunction with a horizontal economizer, the Barometric Relief Hood helps to equalize the building pressure that is caused by the fresh air that is introduced through the economizer fresh air hood. • Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) Sensor replaces supply air temperature dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature of indoor supply air plus the enthalpy content of the outdoor air. • Duct/Unit Mount CO2 Kit (S1-2AQ04700924) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Wall Mount CO2 Kit (S1-2AQ04701024) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) Outdoor supply air temperature sensor kit used with economizers. • Filter/Frame Kit (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. • Filter (S1-02647812000) - Washable 1" filter. Two filters are required for A base units. Three filters are required for B base units. • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are 4 preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PCG4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCG4 price pages for more details. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Transformer Kit (S1-2EC06700124) - Kit provides necessary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. (Required on installations with economizer or motorized damper). • Loss of Charge Switch (S1-2LC00024) - Kit provides Loss of Charge switch and wiring to provide safe shutdown of compressor. • Low Ambient Kit (S1-2LA04701024) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0ºF. Standard unit operation 45ºF. • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. • Thermostat (S1-THXU280*) - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with the York Hx™ Touchscreen Thermostat (S1-THXU280*) available through Source1. For more information, see the thermostat section of the Product Equipment Catalog. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. * For additional kit numbers refer to the price pages. Johnson Controls Unitary Products GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powderpainted steel, certified at 1000 hours salt spray test per ASTMB117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products 5564033-YTG-A-0918 Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXVs) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule (California requirement on single phase models only). 5 5564033-YTG-A-0918 PHYSICAL DATA COMPONENT PCG4A30 2.5 PCG4A36 3.0 MODELS PCG4A42 3.5 PCG4B48 PCG4B60 NOMINAL TONNAGE 4.0 5.0 AHRI Cooling Performance Gross Capacity @ AHRI A point (MBH) 23.7 30.1 37.2 43.5 47.7 57.0 AHRI net capacity (MBH) 22.8 29.0 34.6 41.0 45.5 55.0 EER 11.2 11.2 11.2 11.2 11.2 11.2 SEER 14.0 14.0 14.0 14.0 14.0 14.0 Nominal CFM 800 1000 1200 1400 1600 2000 System power (KW) 2.1 2.6 3.2 3.8 4.2 4.8 Refrigerant type R410A R410A R410A R410A R410A R410A Refrigerant charge (lb-oz) 6-0 9-0 8-8 9-4 11-3 12-0 AHRI Gas Heat Performance Heating model 50 75 50 75 50 75 100 75 100 65 100 125 65 100 125 Heat input (K Btu) 50.0 75.0 50.0 75.0 50.0 75.0 100.0 75.0 100.0 65.0 100.0 125.0 65.0 100.0 125.0 Heat output (K Btu) 40 60 40 60 40 60 80 60 80 52 80 100 52 80 100 AFUE % 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 No. burners 2 3 2 3 2 3 4 3 4 2 3 4 2 3 4 No. stages 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Temperature Rise Range (°F) 40-70 40-70 35-65 40-70 40-70 40-70 40-70 Max. Static Pressure w.c. 0.5 0.5 0.5 0.5 0.5 0.5 Max. Outlet Air Temp. (°F) 180 180 180 180 180 180 Gas piping connection (in.) 1/2 1/2 1/2 1/2 1/2 1/2 Dimensions (inches) Length 51-1/4 51-1/4 51 51 51 51 Width 35-3/4 35-3/4 35-3/4 35-3/4 45-3/4 45-3/4 Height 47 47 47 49 49 51 Operating WT. (lbs.) 341 351 386 390 394 401 405 441 443 460 468 473 477 481 488 Compressors Type Scroll Scroll Scroll Scroll Scroll Scroll Outdoor Coil Data Face area (Sq. Ft.) 15.1 15.1 15.1 16.9 19.5 21.5 Rows 1 2 2 2 2 2 Fins per inch 22 22 22 22 22 22 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Indoor Coil Data Face area (Sq. Ft.) 4.6 4.6 4.6 4.6 6.3 6,3 Rows 2 3 3 3 3 3 Fins per inch 16 16 16 16 16 16 Tube diameter 3/8 3/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV TXV TXV TXV Outdoor Fan Data Fan diameter (Inch) 24 24 24 24 26 26 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 1 Motor HP each 1/4 1/4 1/4 1/4 1/3 1/3 RPM 850 850 850 850 850 850 2400 Nominal total CFM 2400 2400 2400 3200 3200 Direct Drive Indoor Fan Data Fan Size (Inch) 11 x 8 11 x 8 11 x 10 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor HP each 1/3 1/2 1/3 1/2 1/2 3/4 3/4 3/4 1 RPM 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max Frame size 48 48 48 48 48 48 Filters Filter Size A A A A B B Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable filQuantity - Size ters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. 6 PCG4A24 2.0 Johnson Controls Unitary Products 5564033-YTG-A-0918 COOLING PERFORMANCE DATA - 2 TON PACKAGED UNIT MODEL NO. PCG4A24 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 23.2 24.3 55 / 45 S.C. 22.6 19.3 K.W. 1.15 1.14 T.C. 22.2 23.7 65 / 55 S.C. 21.7 19.1 K.W. 1.28 1.28 T.C. 21.3 23.0 75 / 63 S.C. 20.8 18.9 K.W. 1.41 1.42 T.C. 20.2 21.8 85 / 69 S.C. 19.9 18.2 K.W. 1.59 1.60 T.C. 19.0 20.7 95 / 75 S.C. 18.9 17.6 K.W. 1.78 1.78 T.C. 17.3 18.7 105 / 83 S.C. 16.9 16.5 K.W. 2.05 2.05 T.C. 15.6 16.7 115 / 89 S.C. 15.0 15.5 K.W. 2.31 2.32 T.C. 14.0 14.8 125 / 95 S.C. 13.1 14.4 K.W. 2.58 2.59 600 75 62 23.9 16.4 1.15 23.2 16.2 1.28 22.4 16.0 1.42 21.6 15.8 1.49 20.8 15.5 1.56 19.1 14.1 1.91 17.4 12.8 2.24 15.7 11.4 2.57 80 67 25.1 15.8 1.15 24.7 15.7 1.29 24.4 15.7 1.43 23.2 15.1 1.61 22.1 14.5 1.79 20.1 13.7 2.05 18.2 12.8 2.30 16.2 12.0 2.55 80 72 25.6 12.5 1.15 25.6 12.3 1.29 25.5 12.1 1.42 24.5 11.6 1.61 23.5 11.2 1.79 22.1 10.4 2.05 20.7 9.7 2.31 19.3 8.9 2.56 80 57 24.2 23.8 1.17 23.4 22.9 1.30 22.5 22.0 1.43 21.4 21.0 1.62 20.4 20.0 1.80 18.6 18.2 2.07 16.9 16.4 2.33 15.1 14.7 2.59 80 62 25.5 21.1 1.16 24.8 21.2 1.30 24.2 21.3 1.44 23.1 20.8 1.62 21.9 20.3 1.80 19.9 18.6 2.07 18.0 17.0 2.33 16.0 15.4 2.59 800 75 62 24.5 18.0 1.30 24.3 18.2 1.28 24.1 18.4 1.26 23.2 18.1 1.39 22.2 17.9 1.51 20.4 16.4 1.88 18.6 15.1 2.24 16.8 13.7 2.59 80 67 26.1 17.1 1.17 25.8 17.2 1.31 25.6 17.3 1.45 24.8 17.0 1.63 24.0 16.7 1.81 21.8 15.8 2.07 19.6 15.0 2.32 17.5 14.2 2.58 80 72 27.1 13.4 1.18 27.1 13.4 1.31 27.2 13.4 1.45 26.0 12.8 1.63 24.8 12.3 1.82 23.5 11.6 2.08 22.3 10.9 2.34 21.0 10.2 2.59 80 57 25.3 25.0 1.19 24.5 24.1 1.33 23.7 23.1 1.46 22.7 22.1 1.64 21.7 21.2 1.82 19.9 19.5 2.09 18.1 17.9 2.35 16.3 16.2 2.60 80 62 26.7 22.9 1.19 26.0 23.3 1.33 25.4 23.7 1.47 24.3 23.4 1.64 23.1 23.1 1.82 21.1 20.8 2.09 19.2 18.6 2.34 17.2 16.3 2.60 1000 75 62 25.1 19.6 1.46 25.5 20.1 1.28 25.9 20.7 1.11 24.8 20.5 1.29 23.7 20.3 1.47 21.7 18.8 1.85 19.8 17.3 2.23 18.0 15.9 2.61 80 67 27.1 18.4 1.19 26.9 18.6 1.33 26.8 18.9 1.47 26.4 18.9 1.65 25.9 18.8 1.83 23.5 17.9 2.09 21.1 17.1 2.35 18.7 16.3 2.60 80 72 28.5 14.4 1.20 28.7 14.5 1.34 28.9 14.7 1.47 27.5 14.1 1.66 26.2 13.4 1.84 25.0 12.8 2.11 23.8 12.1 2.36 22.7 11.5 2.62 80 67 37.3 23.0 1.38 35.8 22.3 1.53 34.4 21.6 1.68 31.7 20.1 1.89 29.0 18.6 2.10 26.4 17.6 2.39 23.9 16.6 2.67 21.4 15.7 2.95 80 72 40.5 18.7 1.39 39.1 18.1 1.55 37.6 17.5 1.71 35.5 16.5 1.92 33.4 15.5 2.12 30.5 14.4 2.41 27.6 13.2 2.68 24.8 12.0 2.96 80 57 34.6 33.8 1.43 33.0 32.2 1.59 31.4 30.6 1.76 29.5 28.8 1.97 27.6 27.0 2.18 25.5 25.1 2.46 23.5 23.2 2.74 21.4 21.3 3.02 80 62 36.1 30.2 1.43 34.3 29.7 1.59 32.6 29.2 1.75 30.6 27.9 1.96 28.6 26.7 2.17 25.8 24.4 2.46 23.1 22.1 2.74 20.4 19.9 3.02 1000 75 62 36.5 25.8 1.44 34.5 25.1 1.58 32.6 24.4 1.72 29.8 20.6 1.93 27.1 16.8 2.14 24.3 16.9 2.44 21.6 16.9 2.73 19.0 17.0 3.02 80 67 38.9 25.1 1.45 37.6 25.0 1.60 36.3 24.8 1.76 33.4 23.2 1.96 30.5 21.5 2.17 27.6 20.4 2.46 24.8 19.4 2.74 22.0 18.3 3.02 80 72 41.8 19.8 1.46 40.3 19.3 1.62 38.9 18.9 1.77 36.7 17.9 1.98 34.5 16.9 2.19 31.3 15.7 2.48 28.3 14.5 2.75 25.2 13.3 3.03 80 57 37.3 36.9 1.50 35.4 34.8 1.67 33.5 32.7 1.83 31.5 30.9 2.04 29.5 29.1 2.25 27.1 26.8 2.53 24.8 24.6 2.81 22.5 22.3 3.09 80 62 37.8 33.4 1.50 35.8 32.9 1.66 33.8 32.5 1.82 32.0 31.1 2.03 30.1 29.6 2.24 27.1 26.5 2.53 24.2 23.4 2.80 21.3 20.3 3.08 1200 75 62 38.2 28.2 1.51 36.2 27.6 1.67 34.3 27.0 1.83 31.0 22.6 2.04 27.7 18.1 2.24 24.7 18.2 2.53 21.8 18.2 2.81 18.9 18.3 3.08 80 67 40.5 27.2 1.52 39.3 27.6 1.67 38.1 28.1 1.83 35.1 26.2 2.03 32.0 24.4 2.24 28.8 23.2 2.52 25.7 22.1 2.80 22.5 21.0 3.08 80 72 43.0 21.0 1.52 41.6 20.6 1.68 40.1 20.3 1.84 37.9 19.3 2.05 35.6 18.3 2.26 32.2 17.0 2.55 28.9 15.8 2.82 25.6 14.6 3.10 COOLING PERFORMANCE DATA - 2.5 TON PACKAGED UNIT MODEL NO. PCG4A30 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 31.9 34.4 55 / 45 S.C. 30.6 27.0 K.W. 1.36 1.37 T.C. 30.6 32.9 65 / 55 S.C. 29.6 26.4 K.W. 1.52 1.52 T.C. 29.3 31.4 75 / 63 S.C. 28.5 25.9 K.W. 1.68 1.68 T.C. 27.5 29.2 85 / 69 S.C. 26.7 24.8 K.W. 1.90 1.89 T.C. 25.6 27.0 95 / 75 S.C. 25.0 23.8 K.W. 2.11 2.10 T.C. 23.9 24.5 105 / 83 S.C. 23.4 22.3 K.W. 2.40 2.39 T.C. 22.1 22.0 115 / 89 S.C. 21.8 20.8 K.W. 2.67 2.67 T.C. 20.4 19.4 125 / 95 S.C. 20.3 19.4 K.W. 2.95 2.95 Johnson Controls Unitary Products 800 75 62 34.7 23.5 1.37 32.8 22.7 1.49 30.9 21.9 1.61 28.7 18.7 1.82 26.4 15.5 2.04 23.9 15.6 2.35 21.5 15.6 2.65 19.1 15.7 2.95 7 5564033-YTG-A-0918 COOLING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. PCG4A36 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 36.0 38.3 55 / 45 S.C. 34.5 30.6 K.W. 1.82 1.83 T.C. 34.6 36.4 65 / 55 S.C. 33.2 29.8 K.W. 2.01 2.02 T.C. 33.2 34.6 75 / 63 S.C. 32.0 28.9 K.W. 2.20 2.20 T.C. 31.7 32.6 85 / 69 S.C. 30.4 26.9 K.W. 2.46 2.44 T.C. 30.1 30.6 95 / 75 S.C. 28.8 25.0 K.W. 2.72 2.67 T.C. 29.0 28.3 105 / 83 S.C. 27.5 23.9 K.W. 2.91 2.92 T.C. 27.9 26.0 115 / 89 S.C. 26.3 22.9 K.W. 3.11 3.16 T.C. 26.8 23.8 125 / 95 S.C. 25.1 21.9 K.W. 3.30 3.39 1000 75 62 40.3 27.6 1.83 37.4 26.0 2.02 34.5 24.5 2.21 32.2 23.3 2.47 29.8 22.2 2.73 27.8 20.9 2.95 25.9 19.6 3.17 24.0 18.3 3.39 80 67 44.9 27.9 1.83 42.6 26.8 2.03 40.3 25.7 2.22 37.8 24.6 2.48 35.3 23.4 2.74 32.8 21.8 2.96 30.4 20.3 3.19 28.0 18.7 3.41 80 72 48.1 22.6 1.85 46.1 21.6 2.04 44.0 20.7 2.23 41.2 19.3 2.49 38.4 17.9 2.74 36.1 16.9 2.97 33.9 15.9 3.20 31.7 14.9 3.42 80 57 38.9 37.1 1.89 37.3 35.6 2.09 35.7 34.1 2.28 34.0 32.4 2.53 32.3 30.8 2.79 31.1 29.4 2.95 30.0 28.1 3.10 28.9 26.8 3.25 80 62 40.4 33.8 1.90 38.3 32.9 2.09 36.3 32.0 2.28 34.0 30.3 2.53 31.7 28.6 2.77 29.6 27.1 3.01 27.4 25.8 3.24 25.3 24.4 3.47 1200 75 62 42.1 29.9 1.90 39.4 28.5 2.09 36.6 27.2 2.28 33.8 25.8 2.54 31.0 24.3 2.80 28.9 22.9 3.02 26.8 21.6 3.24 24.8 20.2 3.46 80 67 46.8 30.2 1.91 44.2 28.9 2.10 41.7 27.7 2.30 38.9 26.5 2.55 36.2 25.3 2.81 33.8 23.8 3.04 31.4 22.3 3.26 29.0 20.9 3.48 80 72 49.8 23.9 1.92 47.9 23.4 2.11 46.1 22.9 2.30 42.8 21.1 2.56 39.6 19.3 2.82 37.1 18.2 3.05 34.7 17.2 3.27 32.3 16.2 3.49 80 57 41.8 39.6 1.97 40.0 37.9 2.16 38.1 36.1 2.36 36.3 34.5 2.61 34.5 32.8 2.87 33.3 31.3 2.98 32.1 29.9 3.10 31.0 28.5 3.21 80 62 42.5 37.1 1.97 40.2 36.1 2.16 37.9 35.2 2.36 35.4 33.7 2.61 32.8 32.2 2.87 30.8 30.4 3.10 28.9 28.6 3.32 26.9 26.9 3.55 1400 75 62 43.9 32.2 1.98 41.3 31.0 2.17 38.7 29.9 2.36 35.4 28.2 2.61 32.1 26.5 2.87 29.9 25.0 3.10 27.8 23.5 3.32 25.6 22.1 3.54 80 67 48.8 32.5 1.99 45.9 31.1 2.18 43.1 29.7 2.37 40.1 28.4 2.63 37.1 27.2 2.88 34.7 25.8 3.11 32.3 24.4 3.33 30.0 23.1 3.55 80 72 51.5 25.1 1.99 49.8 25.1 2.19 48.2 25.0 2.38 44.5 22.8 2.63 40.8 20.7 2.89 38.1 19.6 3.12 35.5 18.5 3.35 33.0 17.4 3.57 80 67 51.8 34.4 2.38 48.9 32.8 2.62 46.0 31.3 2.87 42.7 28.5 3.18 39.3 25.8 3.48 34.9 24.5 3.90 30.7 23.1 4.30 26.5 21.8 4.70 80 72 57.3 28.7 2.38 54.1 27.5 2.61 51.0 26.2 2.84 47.6 24.5 3.15 44.1 22.8 3.47 39.4 20.9 3.90 34.7 19.0 4.31 30.1 17.2 4.73 80 57 46.5 45.5 2.42 44.4 43.7 2.55 42.2 41.9 2.67 39.3 39.2 2.98 36.5 36.5 3.29 32.5 32.5 3.72 28.7 28.7 4.14 24.9 24.9 4.57 80 62 48.6 42.1 2.44 45.6 40.5 2.68 42.6 38.8 2.93 40.0 36.1 3.24 37.4 33.3 3.54 33.0 30.3 3.97 28.8 27.4 4.38 24.5 24.5 4.79 1400 75 62 48.5 36.2 2.43 45.6 34.4 2.66 42.6 32.7 2.89 39.3 31.0 3.20 35.9 29.4 3.51 31.5 26.9 3.94 27.2 24.4 4.35 22.9 22.0 4.76 80 67 53.7 37.0 2.45 50.5 35.3 2.70 47.4 33.6 2.94 43.8 31.2 3.24 40.2 28.9 3.54 35.5 27.0 3.97 30.9 25.2 4.37 26.4 23.3 4.78 80 72 59.6 30.7 2.47 56.1 29.2 2.71 52.5 27.6 2.94 48.8 25.9 3.26 45.1 24.1 3.57 40.0 22.1 3.99 35.0 20.1 4.41 30.1 18.1 4.82 80 57 49.4 47.8 2.50 46.6 45.5 2.73 43.8 43.3 2.97 40.7 40.4 3.28 37.6 37.6 3.59 33.3 33.3 4.01 29.2 29.2 4.43 25.1 25.1 4.84 80 62 50.2 45.0 2.52 47.0 43.2 2.76 43.9 41.4 3.00 41.8 37.7 3.30 39.7 33.9 3.60 34.8 31.0 4.03 30.1 28.2 4.45 25.4 25.4 4.86 1600 75 62 50.2 38.5 2.51 47.0 36.4 2.74 43.7 34.3 2.97 40.1 32.8 3.28 36.5 31.3 3.59 31.8 28.4 4.01 27.3 25.6 4.42 22.8 22.8 4.83 80 67 55.5 39.6 2.53 52.1 37.7 2.77 48.7 35.9 3.01 44.9 33.9 3.31 41.1 32.0 3.60 36.1 29.5 4.03 31.1 27.2 4.45 26.2 24.8 4.87 80 72 61.9 32.6 2.56 58.0 30.8 2.80 54.1 29.0 3.04 50.0 27.3 3.36 46.0 25.5 3.67 40.6 23.3 4.09 35.3 21.2 4.50 30.1 19.1 4.91 COOLING PERFORMANCE DATA - 3.5 TON PACKAGED UNIT MODEL NO. PCG4A42 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 43.7 46.9 55 / 45 S.C. 43.1 39.2 K.W. 2.35 2.36 T.C. 42.2 44.1 65 / 55 S.C. 41.9 37.7 K.W. 2.36 2.61 T.C. 40.6 41.3 75 / 63 S.C. 40.6 36.3 K.W. 2.38 2.86 T.C. 38.0 38.2 85 / 69 S.C. 38.0 34.5 K.W. 2.69 3.17 T.C. 35.4 35.1 95 / 75 S.C. 35.4 32.7 K.W. 3.00 3.48 T.C. 31.7 31.2 105 / 83 S.C. 31.7 29.6 K.W. 3.44 3.90 T.C. 28.2 27.4 115 / 89 S.C. 28.2 26.7 K.W. 3.86 4.31 T.C. 24.7 23.7 125 / 95 S.C. 24.7 23.7 K.W. 4.29 4.71 8 1200 75 62 46.8 33.9 2.36 44.1 32.5 2.59 41.4 31.0 2.82 38.4 29.3 3.13 35.4 27.6 3.44 31.2 25.4 3.86 27.1 23.3 4.28 23.0 21.2 4.69 Johnson Controls Unitary Products 5564033-YTG-A-0918 COOLING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. PCG4B48 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 50.7 55.0 55 / 45 S.C. 48.2 44.8 K.W. 2.48 2.52 T.C. 48.0 52.0 65 / 55 S.C. 44.3 43.2 K.W. 2.76 2.79 T.C. 45.4 49.0 75 / 63 S.C. 40.3 41.7 K.W. 3.04 3.06 T.C. 42.9 45.4 85 / 69 S.C. 38.3 39.8 K.W. 3.41 3.42 T.C. 40.4 41.8 95 / 75 S.C. 36.4 38.0 K.W. 3.79 3.79 T.C. 36.7 37.6 105 / 83 S.C. 32.3 34.7 K.W. 4.30 4.30 T.C. 33.1 33.6 115 / 89 S.C. 28.4 31.6 K.W. 4.80 4.80 T.C. 29.5 29.5 125 / 95 S.C. 24.5 28.4 K.W. 5.30 5.29 1400 75 62 54.4 38.3 2.51 51.2 36.7 2.79 48.1 35.0 3.06 44.9 33.2 3.42 41.7 31.4 3.78 37.5 29.7 4.29 33.3 28.0 4.79 29.2 26.4 5.30 80 67 59.4 38.5 2.54 57.1 37.1 2.81 54.9 35.7 3.08 51.3 33.7 3.44 47.7 31.8 3.80 43.5 30.0 4.32 39.4 28.4 4.83 35.3 26.7 5.33 80 72 65.3 30.4 2.56 62.8 29.6 2.83 60.3 28.7 3.11 56.4 27.3 3.46 52.4 25.9 3.82 47.8 23.9 4.34 43.4 21.9 4.85 39.0 19.9 5.35 80 57 53.0 49.3 2.56 50.3 46.3 2.83 47.5 43.4 3.10 44.8 41.4 3.47 42.1 39.4 3.85 38.1 34.3 4.36 34.1 29.4 4.87 30.2 24.5 5.37 80 62 56.8 48.2 2.59 53.6 46.6 2.85 50.4 45.1 3.12 46.6 42.4 3.49 42.7 39.7 3.85 38.4 36.1 4.36 34.3 32.5 4.86 30.1 29.0 5.36 1600 75 62 56.1 41.0 2.58 52.9 39.3 2.85 49.6 37.6 3.12 46.1 35.7 3.48 42.6 33.8 3.83 38.0 31.1 4.35 33.6 28.6 4.86 29.2 26.0 5.36 80 67 61.2 40.7 2.61 58.7 39.4 2.88 56.2 38.1 3.14 52.5 36.3 3.50 48.7 34.5 3.86 44.3 32.6 4.38 40.0 30.7 4.89 35.7 28.8 5.39 80 72 67.2 31.9 2.62 64.4 30.8 2.89 61.6 29.7 3.17 57.7 28.4 3.53 53.8 27.0 3.89 48.9 24.9 4.41 44.2 22.9 4.91 39.5 20.9 5.41 80 57 55.4 50.3 2.64 52.5 48.4 2.90 49.6 46.4 3.16 46.7 44.4 3.53 43.9 42.4 3.90 39.5 36.4 4.43 35.2 30.5 4.93 30.9 24.6 5.44 80 62 58.6 51.5 2.65 55.2 50.0 2.92 51.8 48.4 3.18 47.7 44.9 3.55 43.6 41.4 3.91 39.2 37.4 4.42 35.0 33.5 4.92 30.7 29.6 5.42 1800 75 62 57.9 43.6 2.64 54.5 41.9 2.91 51.1 40.2 3.18 47.2 38.2 3.54 43.4 36.2 3.89 38.6 32.6 4.41 33.8 29.1 4.92 29.1 25.6 5.42 80 67 63.1 42.9 2.67 60.3 41.7 2.94 57.5 40.5 3.21 53.6 38.9 3.57 49.7 37.3 3.92 45.1 35.1 4.44 40.6 33.0 4.95 36.1 31.0 5.45 80 72 69.1 33.4 2.68 66.0 32.1 2.95 62.9 30.8 3.23 59.1 29.4 3.59 55.2 28.1 3.95 50.0 26.0 4.47 45.0 23.9 4.97 40.0 21.9 5.47 80 67 73.0 43.7 3.00 69.7 43.2 3.31 66.4 42.7 3.63 61.8 40.5 4.04 57.1 38.2 4.44 51.1 36.0 5.01 45.3 33.8 5.57 39.5 31.6 6.12 80 72 79.5 36.0 3.03 75.7 34.9 3.35 72.0 33.7 3.67 67.1 31.6 4.07 62.3 29.4 4.48 55.2 26.7 5.05 48.3 24.0 5.60 41.4 21.3 6.15 80 57 70.4 66.7 3.15 66.2 62.8 3.46 62.1 59.0 3.78 58.7 56.2 4.19 55.3 53.5 4.61 52.5 50.0 5.22 49.8 46.6 5.80 47.1 43.1 6.39 80 62 70.4 57.0 3.17 66.4 55.9 3.48 62.5 54.7 3.79 57.8 52.2 4.21 53.0 49.7 4.62 47.6 44.0 5.19 42.3 38.4 5.75 36.9 32.9 6.30 1800 75 62 69.3 48.8 3.18 65.1 46.7 3.49 60.9 44.7 3.80 56.6 43.1 4.21 52.3 41.5 4.62 45.6 37.3 5.19 39.0 33.3 5.74 32.5 29.2 6.30 80 67 74.8 46.3 3.21 71.0 45.4 3.52 67.1 44.5 3.84 62.3 42.5 4.24 57.5 40.4 4.65 51.0 37.8 5.22 44.7 35.3 5.77 38.3 32.8 6.32 80 72 80.8 37.1 3.24 76.5 35.7 3.56 72.2 34.3 3.88 67.4 32.8 4.28 62.6 31.2 4.68 55.2 28.1 5.25 47.9 25.0 5.80 40.7 21.9 6.35 80 57 72.7 70.1 3.36 68.4 65.3 3.68 64.0 60.6 3.99 60.0 57.5 4.41 56.1 54.4 4.82 52.8 50.4 5.40 49.7 46.6 5.96 46.6 42.7 6.52 80 62 71.7 59.2 3.38 67.5 58.3 3.69 63.2 57.5 4.00 58.4 55.0 4.42 53.7 52.5 4.83 47.9 45.8 5.40 42.3 39.4 5.95 36.8 32.9 6.51 2000 75 62 70.5 51.4 3.38 65.9 48.9 3.69 61.4 46.3 4.01 57.0 45.1 4.42 52.5 43.8 4.83 45.2 38.3 5.40 38.1 33.1 5.95 31.0 27.8 6.50 80 67 76.6 48.8 3.42 72.3 47.6 3.73 67.9 46.3 4.04 62.9 44.5 4.45 57.9 42.6 4.86 50.9 39.7 5.42 44.0 36.9 5.97 37.2 34.1 6.52 80 72 82.2 38.2 3.45 77.4 36.5 3.77 72.5 34.9 4.08 67.7 33.9 4.48 62.9 33.0 4.88 55.1 29.5 5.45 47.5 26.0 6.00 39.9 22.6 6.55 COOLING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. PCG4B60 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 68.0 69.1 S.C. 63.3 54.8 55 / 45 K.W. 2.93 2.97 T.C. 64.1 65.4 S.C. 60.3 53.4 65 / 55 K.W. 3.25 3.27 T.C. 60.2 61.8 S.C. 57.4 52.0 75 / 63 K.W. 3.56 3.58 T.C. 57.4 57.1 S.C. 55.0 49.4 85 / 69 K.W. 3.98 4.00 T.C. 54.5 52.4 S.C. 52.6 46.9 95 / 75 K.W. 4.40 4.42 T.C. 52.1 47.2 S.C. 49.5 42.1 105 / 83 K.W. 5.03 4.99 T.C. 49.8 42.2 S.C. 46.6 37.5 115 / 89 K.W. 5.65 5.54 T.C. 47.5 37.1 S.C. 43.6 32.8 125 / 95 K.W. 6.27 6.09 Johnson Controls Unitary Products 1600 75 62 68.1 46.2 2.97 64.3 44.6 3.28 60.5 43.1 3.59 56.2 41.1 4.01 52.0 39.2 4.42 45.9 36.3 4.99 40.0 33.4 5.54 34.1 30.6 6.09 9 5564033-YTG-A-0918 81,77233$1(/ &251(53267 ,1'225&2,/ &2,/*8$5' +,*+92/7$*( 23(1,1*´ & +,*+92/7$*( 23(1,1*´ &20%867,21$,5,17$.( +($7(;&+$1*(5$&&(663$1(/ &2035(6625 $&&(663$1(/ )/8((;+$867+22' &21'(16$7( '5$,1 %/2:(5 $&&(66 3$1(/ $ &21752/+($7 $&&(663$1(/ % /2:92/7$*(23(1,1*´ *$66833/<+2/(´:,7+ *5200(723(1,1*2)´ $ UNIT DIMENSIONS Model A24 A30 A36 A42 B48 B60 A 51-1/4 51-1/4 51-1/4 51-1/4 51-1/4 51-1/4 Dimensions - in inches B 35-3/4 35-3/4 35-3/4 35-3/4 45-3/4 45-3/4 C 47 47 47 49 49 51 Distance (in.) 36 36 0 Direction Power Entry (Right Side) Left Side Bottom4 Distance (in.) 36 24 1 UNIT CLEARANCES1 2 Direction Top3 Side Opposite Ducts Duct Panel 1. 2. 3. 4. 10 A 1" clearance must be provided between any combustible material and the supply air duct work. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. Units may be installed on combustible floors made from class A, B or C roof covering materials. Johnson Controls Unitary Products 5564033-YTG-A-0918 INDOOR BLOWER SPECIFICATIONS Motor Model HP 1/3 1/2 1/3 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 24050 24075 30050 30075 36050 36075 36100 42075 42100 48065 48100 48125 60065 60100 60125 RPM Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable Variable EFF. 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 SF 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Frame 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 SOUND PERFORMANCE Model (Tons) Sound Rating1 dB (A) A24 A30 A36 A42 B48 B60 75 75 74 74 74 76 125 62.4 60.5 58.5 63.5 63.5 72.3 250 61.5 61.6 61.8 63.9 63.9 65.0 Octave Band Centerline Frequency (Hz) 500 1000 2000 64.2 67.0 61.0 64.8 66.9 60.9 65.4 66.5 60.7 62.3 65.0 64.0 62.3 65.0 64.0 63.9 64.0 60.0 4000 57.3 56.0 54.8 54.1 54.1 55.5 8000 49.6 49.7 49.8 46.6 46.6 49.0 1. Rated in accordance with AHRI Standard 270. ELECTRICAL DATA Model 24050 24075 30050 30075 36050, 36075 36100 42075, 42100 48065, 48100, 48125 60065, 60100, 60125 Compressor Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 OD Fan Motor Supply Blower Motor RLA LRA MCC FLA FLA 12.8 12.8 14.1 14.1 16.7 16.7 17.9 21.8 24.4 58.3 58.3 73.0 73.0 79.0 79.0 112.0 117.0 144.2 20.0 20.0 22.0 22.0 26.0 26.0 28.0 34.0 38.0 0.7 0.7 0.8 0.8 1.3 1.3 1.3 1.7 1.7 2.6 3.8 2.6 3.8 3.8 5.4 5.4 5.4 7.0 MCA1 (Amps) 19.3 20.5 21.0 22.2 26.0 27.6 29.1 34.4 39.2 Max Fuse2/ Breaker3 Size (Amps) 30 30 35 35 40 40 45 50 60 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 11 5564033-YTG-A-0918 "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT Y "B" X A0295-001-TG WEIGHTS & DIMENSIONS Model 24050 24075 30050 30075 36050 36075 36100 42075 42100 48065 48100 48125 60065 60100 60125 12 Weight (lbs.) Shipping 346 356 391 395 399 406 410 446 448 465 473 478 482 486 493 Operating 341 351 386 390 394 401 405 441 443 460 468 473 477 481 488 Center of Gravity X 28 28 28 28 28 28 28 28 28 28 28 28 29 28 27 Y 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 4 Point Load Location (lbs.) A 120 124 139 146 141 135 139 145 148 189 169 164 174 177 151 B 95 96 99 93 107 115 113 112 110 116 139 145 142 140 167 C 81 81 90 82 94 103 99 99 96 93 115 124 124 117 141 D 71 76 84 95 78 74 80 85 89 117 100 95 92 102 84 Johnson Controls Unitary Products 5564033-YTG-A-0918 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION Model External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 567 517 470 415 674 628 579 530 676 631 583 533 865 823 778 739 1035 996 960 925 750 705 664 613 850 803 759 713 1039 993 949 906 1224 1185 1146 1107 1331 1318 1281 1241 554 512 461 411 779 735 692 650 868 826 787 747 958 918 874 837 1018 978 941 903 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 732 818 823 994 1148 887 978 1171 1349 1487 700 906 992 1075 1136 0.2 SCFM 667 771 774 948 1108 847 941 1114 1297 1462 657 868 951 1032 1089 0.3 SCFM 624 723 721 906 1071 802 898 1074 1265 1392 599 825 911 1000 1053 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 1076 1102 1191 1201 1370 1003 1180 1259 1314 1506 1225 1259 1314 1348 1506 1342 1425 1554 1658 1966 1315 1436 1020 1048 1140 1225 1329 952 1133 1209 1271 1471 1174 1209 1271 1306 1471 1302 1368 1503 1599 1914 1266 1382 984 1010 1112 1187 1283 904 1085 1166 1229 1403 1131 1166 1229 1259 1403 1260 1332 1465 1588 1862 1229 1342 943 974 1076 1151 1271 851 1042 1126 1186 1389 1090 1126 1186 1222 1389 1217 1293 1423 1530 1810 1194 1304 903 934 1038 1118 1209 790 995 1084 1144 1345 1046 1084 1144 1179 1345 1178 1251 1386 1495 1757 1156 1262 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 42100 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 48065 Medium (3) Medium/High (4) High (5) Continued on next page. 1458 1573 1966 1436 1544 1573 1681 1935 1046 1295 1620 1798 2146 1406 1523 1914 1382 1492 1523 1640 1887 1009 1250 1564 1722 2085 1365 1484 1862 1342 1455 1484 1599 1834 980 1213 1517 1669 2025 1327 1445 1810 1304 1416 1445 1557 1788 946 1172 1466 1620 1960 1286 1408 1757 1262 1376 1408 1517 1743 915 1133 1418 1572 1872 24050 24075 30050 30075 36050 36075 36100 Motor Speed 42075 Johnson Controls Unitary Products 0.8 SCFM 369 482 505 700 901 563 667 864 1063 1201 365 608 712 800 1.0 SCFM 277 386 448 622 853 463 575 780 975 1121 273 524 642 726 859 890 1000 1080 1176 730 942 1032 1097 1305 993 1032 1097 1133 1305 1134 1208 1346 1454 1705 1117 819 850 958 1041 1143 674 889 980 1049 1262 941 980 1049 1086 1262 1082 1163 1302 1414 1653 1080 869 779 810 919 1002 1109 633 834 928 998 1216 888 928 998 1036 1216 1034 1113 1257 1373 1600 1036 801 699 730 841 924 1041 551 724 824 896 1124 782 824 896 936 1124 938 1013 1167 1291 1496 948 1220 1244 1367 1705 1220 1336 1367 1478 1701 878 1087 1360 1527 1862 1179 1203 1327 1653 1179 1294 1327 1436 1651 844 1045 1308 1480 1798 1131 1155 1279 1600 1131 1248 1279 1393 1591 779 964 1206 1413 1735 1035 1059 1183 1496 1035 1156 1183 1307 1471 649 802 1002 1280 1609 13 5564033-YTG-A-0918 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued) Model 48100 48125 60065 60100 60125 1. 2. 3. 4. 5. 14 Motor Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) 0.1 SCFM 1620 1694 1798 1835 2146 1620 1798 1922 2001 2146 1073 1329 2054 2195 2445 1730 0.2 SCFM 1564 1630 1722 1758 2085 1564 1722 1863 1952 2085 1043 1292 1998 2144 2388 1682 0.3 SCFM 1517 1580 1669 1703 2025 1517 1669 1804 1890 2025 1009 1250 1934 2098 2306 1628 Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 1858 2054 2195 2445 2063 2130 2195 2275 2445 1807 1998 2144 2388 2008 2084 2144 2252 2388 1749 1934 2098 2306 1943 2032 2098 2169 2306 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1466 1418 1360 1308 1530 1482 1430 1380 1620 1572 1527 1480 1653 1604 1558 1511 1960 1872 1862 1798 1466 1418 1360 1308 1620 1572 1527 1480 1754 1724 1658 1612 1839 1820 1742 1696 1960 1872 1862 1798 988 963 941 917 1223 1192 1165 1136 1890 1843 1801 1757 2049 2003 1955 1883 2293 2235 2178 2129 1592 1552 1517 1479 1710 1890 2049 2293 1899 1983 2049 2154 2293 1667 1843 2003 2235 1851 1927 2003 2112 2235 1629 1801 1955 2178 1809 1951 1955 2065 2178 1589 1757 1883 2129 1763 1860 1883 1989 2129 0.8 SCFM 1206 1292 1413 1442 1735 1206 1413 1559 1651 1735 892 1105 1710 1868 2077 1.0 SCFM 1002 1116 1280 1304 1609 1002 1280 1453 1561 1609 842 1043 1616 1838 1973 1439 1546 1710 1868 2077 1717 1815 1868 1976 2077 1359 1460 1616 1838 1973 1625 1725 1838 1950 1973 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5564033-YTG-A-0918 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION Model External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 611 560 491 445 720 677 622 559 828 781 735 686 902 861 817 775 1085 1051 1013 975 782 734 685 630 879 834 787 735 1056 1016 975 935 1248 1211 1174 1127 1367 1369 1299 1264 575 520 467 410 795 745 706 658 900 855 811 770 995 949 908 864 1061 1020 978 938 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 754 867 951 1024 1204 899 1033 1186 1357 1480 726 928 1021 1109 1170 0.2 SCFM 710 815 908 982 1159 869 960 1133 1322 1439 676 886 983 1071 1134 0.3 SCFM 665 773 868 942 1121 827 924 1095 1284 1404 622 841 942 1029 1096 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 1076 1104 1205 1285 1406 1008 1190 1262 1324 1517 1231 1270 1317 1358 1517 1340 1409 1527 1663 1930 1332 1457 1042 1063 1170 1251 1375 962 1148 1223 1282 1475 1186 1225 1286 1317 1475 1299 1368 1492 1585 1892 1295 1419 1009 1025 1136 1213 1341 916 1106 1181 1245 1447 1146 1189 1245 1275 1447 1264 1334 1470 1594 1853 1263 1376 969 987 1098 1179 1306 861 1055 1137 1202 1400 1103 1140 1198 1238 1400 1224 1291 1419 1601 1805 1222 1340 930 947 1060 1141 1271 807 1008 1091 1161 1357 1069 1098 1151 1197 1357 1182 1253 1385 1521 1760 1185 1299 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 42100 Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) 48065 Medium (3) Medium/High (4) High (5) Continued on next page. 1451 1568 1978 1455 1566 1565 1675 1946 1032 1272 1611 1892 2131 1412 1524 1937 1414 1532 1530 1641 1909 999 1236 1574 1777 2058 1371 1491 1891 1379 1492 1491 1606 1863 970 1204 1518 1771 1998 1339 1464 1837 1335 1455 1458 1578 1815 938 1165 1494 1701 1949 1296 1425 1785 1294 1416 1419 1535 1771 910 1129 1439 1639 1892 24050 24075 30050 30075 36050 36075 36100 Motor Speed 42075 Johnson Controls Unitary Products 0.8 SCFM 391 505 631 721 938 575 685 891 1087 1226 376 607 729 826 1.0 SCFM 283 397 521 613 864 465 585 803 1007 1150 308 505 647 750 890 908 1025 1104 1236 757 955 1044 1112 1318 1030 1046 1110 1148 1318 1182 1201 1343 1480 1696 1148 849 869 985 1065 1198 700 914 994 1067 1275 977 1008 1064 1105 1275 1097 1173 1299 1440 1625 1110 899 808 830 943 1027 1163 650 863 952 1018 1232 912 960 1024 1057 1232 1049 1128 1250 1400 1553 1063 821 726 752 859 951 1093 550 761 868 920 1146 781 866 943 961 1146 953 1038 1152 1320 1409 967 1253 1257 1383 1725 1254 1372 1381 1495 1721 879 1081 1405 1617 1840 1215 1211 1345 1656 1212 1333 1336 1455 1654 843 1037 1357 1565 1788 1160 1165 1296 1604 1160 1280 1290 1412 1595 808 968 1266 1489 1728 1051 1072 1200 1502 1056 1174 1198 1326 1477 737 829 1083 1336 1608 15 5564033-YTG-A-0918 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION (Continued) Model 48100 48125 60065 60100 60125 1. 2. 3. 4. 5. 16 Motor Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) 0.1 SCFM 1598 1663 1789 1931 2131 1598 1766 1912 2105 2131 1026 1263 1987 2114 2369 1655 0.2 SCFM 1548 1612 1733 1814 2058 1548 1703 1875 2014 2058 999 1230 1933 2050 2308 1612 0.3 SCFM 1502 1568 1670 1808 1998 1502 1656 1805 2006 1998 989 1192 1861 2047 2249 1596 Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 1766 1987 2114 2369 1973 2024 2123 2191 2369 1720 1933 2050 2308 1924 1983 2075 2154 2308 1667 1861 2047 2249 1905 1937 2019 2117 2249 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 1454 1410 1362 1307 1522 1476 1422 1370 1650 1596 1578 1535 1736 1673 1650 1597 1949 1892 1840 1788 1454 1410 1362 1307 1611 1566 1518 1469 1787 1750 1713 1672 1931 1898 1845 1793 1949 1892 1840 1788 950 907 907 886 1165 1167 1101 1099 1817 1820 1715 1725 1974 1899 1889 1920 2183 2126 2088 2034 1531 1461 1462 1429 1629 1817 1974 2183 1826 1889 1970 2075 2183 1632 1820 1899 2126 1743 1886 1978 2002 2126 1539 1715 1889 2088 1744 1843 1862 1995 2088 1537 1725 1920 2034 1703 1799 1849 2028 2034 0.8 SCFM 1251 1297 1483 1519 1728 1251 1419 1636 1739 1728 862 1071 1651 1866 1990 1.0 SCFM 1139 1152 1379 1362 1608 1139 1319 1564 1631 1608 816 1015 1504 1758 1902 1391 1498 1651 1866 1990 1660 1759 1804 1974 1990 1316 1421 1504 1758 1902 1574 1679 1714 1866 1902 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5564033-YTG-A-0918 ADDITIONAL STATIC RESISTANCE Size (Tons) 024 (2.0) 030 (2.5) 036 (3.0) 042 (3.5) 048 (4.0) 060 (5.0) CFM 500 600 700 800 900 1000 1100 1200 700 800 900 1000 1100 1200 1300 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Wet Indoor Coil Economizer1 Filter/Frame Kit 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.01 0.02 0.04 0.06 0.08 0.10 0.13 0.16 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 2. Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. BOTTOM DUCT DIMENSIONS (Inches) ' ´ & $ 5(7851 $,5'8&7 +2/(´ ( ZLWK´JURPPHW RSHQLQJIRUJDVSLSH % +2/(´ $ IRUKLJK YROWDJH 6833/< $,5'8&7 +2/(´ IRU ORZYROWDJH ) Model 24, 30, 36, 42 48, 60 A 10 14 B 21.5 13.5 $ C 5 5 D 4.5 3.5 E 47.5 47.5 F 32 42 REAR DUCT DIMENSIONS (Inches) 127(6HH)LJXUHWLWOHG³8QLW'LPHQVLRQV´IRUVLGHKROHVL]HVRI HOHFWULFDODQGJDVOLQHV 5(7851 $,5'8&7 6833/< $,5'8&7 $ Model 24, 30, 36, 42 48, 60 Johnson Controls Unitary Products 9,(:/22.,1*83 $7%277202)81,7 ´ $ % A 9.6 13.6 $ B 22 14 17 5564033-YTG-A-0918 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324-001 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE TO GAS SUPPLY LINE 18 CONTROL WIRING TO INDOOR THERMOSTAT A0325-001 Johnson Controls Unitary Products 5564033-YTG-A-0918 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO GAS SUPPLY LINE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT Johnson Controls Unitary Products SUPPLY AIR DUCT A0326- 19 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2018 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5564033-YTG-A-0918 Supersedes: 5005562-YTG-H-1017
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement