5005568-YTG-H-1017 DESCRIPTION These packaged cooling/heating heat pumps are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP / ELECTRIC HEAT 14 SEER – R-410A – 1 PHASE 2 THRU 5 NOMINAL TONS - 208/230V MODELS: PHE4*24 THRU 60 • Operating Efficiency - All PHE4 heat pump models are rated at 14.0 SEER, 11.0 EER and 8.0 HSPF for cooling and heating operation. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A refrigerant and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Extended 10-Years limited parts and compressor warranty * Extended warranty requires online registration within 90 days of purchase for replacement or closing for new home purchase. See limited warranty certificate in User’s Information Manual for details. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the indoor coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5005568-YTG-H-1017 • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance and provide cut protection to the installer • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. • Low Maintenance - Long life, permanently lubricated outdoor and indoor fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly and indoor coil assembly can be easily removed for cleaning or service. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed and heating speeds are factory set at test design conditions but can be field adjusted. This allows maximum comfort capabilities. • Simple Control Circuit - A printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-n-lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of scroll bypass and a temperature thermal overload sensor which protect the compressor if undesirable operating conditions occur. • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils will use tin-coated copper tubing with aluminum fins for effective heat transfer. • Electric Heat - All electric heat models use 6HK electric heat, which are available in 230v/1/60 from 2 kW to 25 kW. Most kits stageable above 10 kW. Single phase single point field wiring kits are available for all applications except 25kW. • Easy Service Access - Individual access panels are provided in access to all major components - compressors, indoor coils, blower, controls/electric heat kits, filters, etc. that makes servicing easy. Removing these panels allow easy removal of the components such as the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Controls - Demand defrost curves pre-loaded into defrost control for optimized performance based on unit capacities. • Loss of Charge Switch - All models include a loss of charge switch to provide safe shutdown of compressor. 2 Johnson Controls Unitary Products 5005568-YTG-H-1017 NOMENCLATURE PHE 4 A 24 2 1 1 2 3 4 6 8 1. Model Family 5. Gas Heating Input BTU/Hr x 1000 PHE - packaged heat pump with electric heat, 050 = 50,000 BTU/Hr. input, blank = electric heat PCG - packaged A/C with gas heat, 6. Voltage-Phase-Frequency PHG - packaged heat pump with gas heat, 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 PCE - packaged A/C with electric heat 2. Nominal Cooling Efficiency 7. NOx Approval 4 = 14 SEER, 6 = 16 SEER, etc. X = low-NOx, blank = not low-Nox 3. Cabinet Size 8. Generation Level A = small 35 x 51, B = large 45 x 51 1 = first generation 4. Nominal Air Conditioning Cooling Capacity BTUx1000 9. Revision Level 24 = 24,000 BTU, etc. A = original release, B = second release Examples: PHE4B4221A is a packaged heat pump, 14 SEER, 3-1/2 ton, large cabinet, 230 volt, 1-phase model, (first generation, first release). A 9 COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL AMBIENT TEMPERATURE SENSOR CONTROL BOARD OUTDOOR TXV CAPACITOR REVERSING VALVE INDOOR TXV TRANSFORMER COMPRESSOR BLOWER MOTOR OPTIONAL ELECTRIC HEAT KIT INDOOR COIL INDOOR BLOWER REMOVABLE BASE RAILS A0380-001 UNIT LIMITATIONS Model PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 Unit Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Johnson Controls Unitary Products Min 187 187 187 187 187 187 Unit Limitations Applied Voltage Max 252 252 252 252 252 252 Outdoor DB Temp Max (°F) 125 125 125 125 125 125 3 5005568-YTG-H-1017 ACCESSORIES • Economizer for Downflow Applications (S1-2EE04710024, S1-2EE04710124) - Modulating integrated economizer provides simultaneous operation between mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single/dual enthalpy kits are also available. • Economizer for Horizontal Applications (S1-2EE04710224, S1-2EE04710324) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are available. • Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • Duct/Unit Mount CO2 Kit (S1-2AQ04700924) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Wall Mount CO2 Kit (S1-2AQ04701024) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) Outdoor supply air temperature sensor kit used with economizers. • Filter/Frame Kit (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. • Filter (S1-02647812000) - Washable 1" filter. Two filters are required for A base units. Three filters are required for B base units. • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct 4 openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed for assembly through hinge pins in each corner. Kit also provides seal strip to assure air tight seal. These are 14 inch high roof curbs. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PHE4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PHE4 price pages for more details. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications and unit mounted down supply/return applications. Includes hood and screen assembly. • Loss of Charge Switch (S1-2LC00024) - Kit provides Loss of Charge switch and wiring to provide safe shutdown of compressor. • Low Ambient Kit (S1-2LA04701024) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. • Transformer Kit (S1-2EC06700124) - Kit provides necessary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. (Required on installations with economizer or motorized damper). • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. • Single Point Wiring Kits for 6HK Electric Heat Applications (S1-SPWK*) - Kit provides field option for connecting electrical power supplies to the field installed 6HK kits to allow single point connections for single phase electric heat applications with the exception of 25kW kits. • Thermostat (S1-THXU280*) - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with the York Hx™ Touchscreen Thermostat (S1-THXU280*) available through Source1. For more information, see the thermostat section of the Product Equipment Catalog. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic non power stealing and electromechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. * For additional kit numbers refer to the price pages. Johnson Controls Unitary Products 5005568-YTG-H-1017 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. Heat pumps provide electric cooling and electric heating, with field installed electric heat kits from 5 kW to 25 kW for backup supplemental heating operation. DESCRIPTION Units shall be factory-assembled, single packaged, Heat Pumps with Electric Cooling/Electric Heating units, designed for outdoor installation. They shall have built in, equal size, field convertible duct connections for downflow supply/return or horizontal supply/return. The units shall be factory wired, piped, and charged with R-410A Refrigerant and factory tested prior to shipment. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed to the UL 1995/CAN/CSA No. 236-M90 standards. • Operating Efficiency - All heat pump models shall be rated at a minimum of 14.0 SEER, 11.0 EER and 8.0 HSPF for cooling and heating operation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. Sound ratings as tested under AHRI test procedures shall be less than 77 dbA for all models. UNIT CABINET Unit cabinet shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for fork truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. • On Site Flexibility - All model sizes shall use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. Johnson Controls Unitary Products • Durable Finish - The cabinet shall be is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel shall provide a better paint-to-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). • Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement shall be used which requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance and prevent water penetration. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Utility Connections Made Easy - Electric utility access shall be provided through the bottom or the side of the unit. Utility connections should be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Easy Service Access - Individual access panels are provided in access to all major components - compressors, indoor coils, blower, controls/electric heat kits, filters, etc. that makes servicing easy. Removing these panels allow easy removal of the components such as the blower assembly for maintenance and ease of troubleshooting. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. Indoor Blower Assembly - Blower shall be direct drive design. Blower wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Design shall use constant torque motors. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. 5 5005568-YTG-H-1017 REFRIGERANT COMPONENTS CONTROLS • Protected Compressor - The compressor shall be a fully hermetic type, direct drive compressor, that is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of operation of scroll bypass valve and a temperature thermal overload sensor which protect the compressor if undesirable operating conditions occur. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. Compressors shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. • Simple Control Circuit - A printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-n-lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. • Indoor Coils - Indoor coils shall be of the direct expansion, draw through design and have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. • Controls - Demand defrost curves pre-loaded into defrost control for optimized performance based on unit capacities. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the indoor coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Outdoor Coils - Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed, and be a draw through design. • Refrigerant Circuit and Refrigerant Safety Components shall include: Thermal expansion devices (TXV's) shall be factory mounted and provided, Filter/strainer to eliminate any foreign matter, reversing valves to control refrigerant flow. 6 • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Factory Testing - Installation time and costs are reduced by easy power and control wiring connections. All units are completely wired, charged with refrigerant R-410A refrigerant and tested prior to shipment. Test stations using a stateof-the-art computerized process system shall be used to insure product quality. Refrigerant charge and component part numbers are verified via computer bar code scans during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. This data could be provided by serial number tracking if necessary. • Electric Heat - All electric heat models use 6HK electric heat, which are available in 230v/1/60 from 2 kW to 25 kW, 230v/3/60 10kW to 25kW, and 460v/3/60 10kW to 25kW. Most kits stageable above 10 kW. Single point accessory kits are available for single phase models. Single phase single point field wiring kits are available for all applications except 25kW. Electric heat kits must be certified to UL 1995 standard requirements. Johnson Controls Unitary Products 5005568-YTG-H-1017 PHYSICAL DATA COMPONENT NOMINAL TONNAGE: AHRI Cooling Performance Gross Capacity @ AHRI A point (MBH) AHRI net capacity (MBH) EER SEER Nominal CFM System power (KW) Refrigerant type Refrigerant charge (lb-oz) AHRI Heating Performance 47 Capacity Rating (MBH) System Power (kW/COP) 17 F Capacity Rating (MBH) HSPF (BTU/Watts-hr.) Dimensions (inches) Length Width Height Operating WT. (lbs.) Compressors Type Outdoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Refrigerant control Indoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Refrigerant control Outdoor Fan Data Fan diameter (Inch) Type Drive type No. speeds Motor HP each RPM Nominal total CFM Direct Drive Indoor Blower Data Fan Size (Inch) Type Motor HP each RPM Frame size Filters Filter size Quantity - Size Johnson Controls Unitary Products MODELS PHE4B3621 PHE4B4221 3.0 3.5 PHE4A2421 2.0 PHE4A3021 2.5 PHE4B4821 4.0 PHE4B6021 5.0 24.1 23.8 11.0 14.0 800 1.8 R410A 8-5 30.1 29.6 11.0 14.0 1000 2.2 R410A 9-8 36.4 35.8 11.0 14.0 1200 2.8 R410A 11-13 42.3 41.5 11.0 14.0 1400 3.2 R410A 13-0 48.2 47.0 11.0 14.0 1600 3.7 R410A 12-13 59.9 58.0 11.0 14.0 1800 4.7 R410A 15-8 22.0 3.7 12.0 8.0 27.2 3.6 14.8 8.0 33.8 3.6 19.6 8.0 38.0 3.6 22.0 8.0 45.5 3.7 26.0 8.0 56.0 3.6 32.0 8.0 51-1/4 35-3/4 47 377 51-1/4 35-3/4 49 392 51-1/4 45-3/4 49 448 51-1/4 45-3/4 49 471 51-1/4 45-3/4 53 496 51-1/4 45-3/4 55 523 Scroll Scroll Scroll Scroll Scroll Scroll 15.1 2 22 3/8 Interlaced TXV 16.9 2 22 3/8 Interlaced TXV 19.4 2 22 3/8 Interlaced TXV 19.4 2 22 3/8 Interlaced TXV 23.8 2 22 3/8 Interlaced TXV 25.9 2 22 3/8 Interlaced TXV 4.6 3 16 3/8 Interlaced TXV 4.6 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 6.3 4 16 3/8 Interlaced TXV 24 Prop Direct 1 1/10 850 2400 24 Prop Direct 1 1/8 850 2400 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 11 x 8 Centrifugal 1/2 1200 Max 48 11 x 8 Centrifugal 1/2 1200 Max 48 11 x 10 Centrifugal 1/2 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 1 1200 Max 48 A A B B B B Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable filters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. 7 5005568-YTG-H-1017 COOLING PERFORMANCE DATA - 2 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PHE4A2421 80 57 24.9 23.5 0.98 24.2 22.5 1.10 23.4 21.5 1.21 22.3 20.4 1.36 21.2 19.4 1.51 19.3 17.8 1.71 17.4 16.2 1.91 15.6 14.7 2.11 80 62 28.3 19.9 0.98 26.9 19.2 1.09 25.4 18.5 1.21 23.5 17.7 1.35 21.7 16.8 1.50 19.5 15.9 1.71 17.4 15.1 1.91 15.3 14.3 2.12 600 75 62 28.3 18.0 0.98 26.9 17.0 1.08 25.5 16.1 1.19 23.7 15.2 1.34 21.9 14.4 1.49 19.7 13.2 1.70 17.5 12.2 1.90 15.4 11.1 2.11 80 67 31.8 17.8 0.98 30.0 16.9 1.09 28.2 16.0 1.20 26.4 15.1 1.35 24.6 14.3 1.50 22.5 13.4 1.71 20.5 12.5 1.91 18.4 11.6 2.11 80 72 34.8 15.0 0.97 33.1 14.1 1.08 31.5 13.2 1.20 29.5 12.4 1.35 27.5 11.6 1.50 24.7 10.5 1.71 22.1 9.5 1.91 19.4 8.5 2.11 80 57 28.3 26.5 1.03 27.2 25.3 1.15 26.1 24.2 1.27 24.7 22.8 1.41 23.4 21.4 1.56 20.9 19.4 1.76 18.6 17.5 1.96 16.2 15.5 2.16 80 62 30.6 23.4 1.03 29.0 22.6 1.15 27.5 21.9 1.26 25.3 20.7 1.41 23.1 19.5 1.55 20.8 18.2 1.76 18.6 16.9 1.96 16.4 15.7 2.17 800 75 62 31.0 20.7 1.03 29.2 19.6 1.14 27.3 18.5 1.25 25.2 17.4 1.40 23.1 16.3 1.54 20.6 15.2 1.75 18.2 14.1 1.96 15.8 13.0 2.16 80 67 34.5 20.2 1.03 32.3 19.4 1.14 30.1 18.7 1.25 28.2 17.6 1.40 26.2 16.6 1.55 23.5 15.5 1.76 20.8 14.4 1.96 18.2 13.2 2.16 80 72 36.9 16.1 1.02 35.2 15.4 1.14 33.6 14.8 1.25 31.4 14.0 1.40 29.2 13.1 1.55 26.2 11.9 1.76 23.3 10.7 1.96 20.4 9.5 2.16 80 57 31.6 29.5 1.08 30.2 28.1 1.20 28.8 26.8 1.32 27.1 25.1 1.47 25.5 23.4 1.61 22.5 21.0 1.82 19.7 18.7 2.01 16.8 16.4 2.21 80 62 32.8 26.8 1.08 31.2 26.0 1.20 29.5 25.2 1.31 27.0 23.7 1.46 24.5 22.1 1.60 22.1 20.4 1.81 19.8 18.8 2.02 17.5 17.1 2.22 1000 75 62 33.8 23.4 1.08 31.4 22.2 1.19 29.1 21.0 1.31 26.7 19.6 1.45 24.4 18.2 1.59 21.6 17.1 1.81 18.9 16.1 2.01 16.2 15.0 2.22 80 67 37.1 22.6 1.08 34.6 22.0 1.19 32.0 21.4 1.31 29.9 20.2 1.45 27.8 18.9 1.60 24.4 17.6 1.81 21.2 16.2 2.01 18.0 14.9 2.21 80 72 39.0 17.1 1.07 37.3 16.8 1.19 35.6 16.4 1.31 33.3 15.5 1.45 30.9 14.7 1.60 27.7 13.3 1.81 24.6 11.9 2.01 21.5 10.5 2.21 80 67 37.2 22.6 1.50 35.6 21.7 1.67 34.0 20.7 1.84 31.6 19.8 2.04 29.2 18.9 2.24 26.0 17.3 2.53 22.8 15.7 2.80 19.7 14.2 3.08 80 72 42.9 18.8 1.51 39.8 17.4 1.67 36.8 16.0 1.84 35.0 15.3 2.04 33.2 14.7 2.25 29.6 13.4 2.54 26.1 12.2 2.81 22.6 10.9 3.09 80 57 32.8 32.2 1.50 31.2 30.7 1.66 29.6 29.3 1.82 27.4 27.1 2.03 25.2 25.0 2.23 22.6 22.4 2.52 20.0 19.9 2.80 17.5 17.4 3.08 80 62 35.3 28.9 1.50 33.5 28.3 1.66 31.7 27.8 1.83 29.5 26.4 2.03 27.3 25.0 2.23 23.8 22.2 2.52 20.4 19.5 2.80 16.9 16.8 3.07 1000 75 62 35.8 24.8 1.50 33.7 23.8 1.66 31.5 22.8 1.82 28.9 21.8 2.03 26.3 20.8 2.23 22.8 18.7 2.51 19.4 16.6 2.79 16.1 14.6 3.07 80 67 39.4 24.4 1.50 37.6 23.9 1.67 35.8 23.4 1.84 33.1 22.3 2.04 30.5 21.2 2.24 27.1 19.4 2.53 23.7 17.6 2.80 20.4 15.9 3.08 80 72 45.4 20.1 1.51 42.7 19.1 1.67 40.0 18.1 1.84 37.4 17.2 2.05 34.8 16.3 2.25 30.8 14.7 2.54 27.0 13.2 2.81 23.1 11.6 3.09 80 57 35.3 35.1 1.50 33.4 33.2 1.66 31.5 31.3 1.83 29.1 28.9 2.03 26.7 26.5 2.24 24.0 23.8 2.53 21.3 21.2 2.81 18.7 18.6 3.09 80 62 37.2 31.7 1.50 35.4 31.4 1.66 33.6 31.1 1.83 30.9 29.5 2.03 28.1 27.9 2.24 24.6 24.4 2.53 21.1 21.0 2.80 17.7 17.5 3.08 1200 75 62 37.8 27.1 1.51 35.5 26.1 1.67 33.2 25.2 1.83 30.3 24.2 2.03 27.4 23.1 2.23 23.6 20.7 2.51 19.9 18.4 2.79 16.1 16.0 3.07 80 67 41.6 26.2 1.51 39.6 26.1 1.67 37.6 26.1 1.84 34.7 24.8 2.04 31.8 23.5 2.24 28.2 21.5 2.53 24.6 19.6 2.80 21.1 17.6 3.08 80 72 47.9 21.5 1.51 45.5 20.9 1.68 43.2 20.3 1.85 39.8 19.1 2.05 36.5 17.9 2.25 32.1 16.0 2.54 27.9 14.2 2.81 23.6 12.3 3.09 COOLING PERFORMANCE DATA - 2.5 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. 8 PHE4A3021 80 57 30.3 29.3 1.50 29.0 28.3 1.66 27.6 27.3 1.82 25.6 25.4 2.02 23.6 23.4 2.23 21.1 21.0 2.52 18.7 18.6 2.80 16.3 16.2 3.08 80 62 33.5 26.1 1.50 31.7 25.3 1.66 29.9 24.5 1.83 28.1 23.3 2.03 26.4 22.1 2.23 22.9 20.1 2.51 19.6 18.1 2.79 16.2 16.1 3.07 800 75 62 33.8 22.5 1.50 31.8 21.5 1.66 29.9 20.5 1.82 27.5 19.5 2.02 25.2 18.6 2.23 22.1 16.7 2.51 19.0 14.9 2.79 16.0 13.1 3.07 Johnson Controls Unitary Products 5005568-YTG-H-1017 COOLING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PHE4B3621 80 57 40.4 40.0 1.97 37.9 37.9 2.17 35.4 35.4 2.36 33.1 33.1 2.63 30.7 30.7 2.89 27.8 27.8 3.26 25.1 25.1 3.63 22.3 22.3 3.99 80 62 43.9 34.9 1.98 41.2 33.7 2.18 38.5 32.5 2.39 35.4 30.8 2.65 32.2 29.1 2.91 28.4 26.7 3.28 24.8 24.3 3.64 21.1 21.1 4.00 1000 75 62 43.9 30.5 1.98 41.4 29.1 2.17 38.9 27.6 2.36 35.8 26.1 2.63 32.7 24.6 2.89 28.7 22.7 3.27 24.9 20.9 3.63 21.1 19.0 4.00 80 67 47.3 29.3 1.98 45.1 28.4 2.18 42.8 27.4 2.39 39.7 25.9 2.65 36.6 24.3 2.91 32.2 22.5 3.28 27.9 20.7 3.63 23.7 18.9 3.99 80 72 46.7 22.4 1.98 47.2 22.3 2.18 47.6 22.1 2.39 44.4 20.7 2.65 41.1 19.4 2.91 36.6 17.6 3.28 32.3 15.8 3.64 27.9 14.1 4.00 80 57 43.3 42.9 2.06 40.4 40.4 2.26 37.5 37.5 2.46 34.7 34.7 2.72 32.0 32.0 2.98 28.8 28.8 3.35 25.7 25.7 3.72 22.6 22.6 4.08 80 62 45.1 40.4 2.07 42.4 38.1 2.27 39.8 35.7 2.48 36.5 34.0 2.74 33.1 32.2 3.00 29.1 28.8 3.37 25.2 25.2 3.73 21.3 21.3 4.09 1200 75 62 45.4 32.6 2.07 42.6 32.7 2.27 39.8 32.9 2.47 36.6 30.0 2.73 33.4 27.1 2.98 29.0 24.6 3.36 24.7 22.2 3.73 20.5 19.8 4.09 80 67 47.7 31.2 2.07 46.0 30.6 2.28 44.2 29.9 2.48 40.7 28.2 2.74 37.1 26.5 3.00 32.3 24.6 3.37 27.7 22.8 3.72 23.0 21.0 4.08 80 72 47.3 23.3 2.07 47.8 23.5 2.28 48.4 23.7 2.48 45.2 22.3 2.74 42.1 21.0 3.00 37.1 19.0 3.37 32.2 17.1 3.73 27.3 15.3 4.09 80 57 46.2 45.9 2.16 42.8 42.8 2.36 39.5 39.5 2.56 36.4 36.4 2.81 33.4 33.4 3.07 29.8 29.8 3.44 26.4 26.4 3.81 22.9 22.9 4.17 80 62 46.2 45.9 2.16 43.7 42.5 2.36 41.1 39.0 2.57 37.5 37.1 2.83 33.9 33.9 3.09 29.7 29.7 3.46 25.6 25.6 3.82 21.5 21.5 4.18 1400 75 62 46.8 34.6 2.16 43.8 36.4 2.37 40.7 38.2 2.58 37.4 33.9 2.83 34.1 29.6 3.08 29.3 26.5 3.45 24.5 23.6 3.82 19.8 19.8 4.18 80 67 48.2 33.0 2.16 46.9 32.7 2.37 45.7 32.5 2.58 41.6 30.6 2.83 37.6 28.7 3.09 32.5 26.8 3.46 27.4 24.9 3.81 22.4 22.4 4.17 80 72 47.8 24.3 2.16 48.5 24.7 2.37 49.1 25.2 2.58 46.0 23.9 2.83 43.0 22.6 3.09 37.5 20.5 3.46 32.1 18.5 3.82 26.8 16.4 4.18 80 67 53.3 33.0 2.28 52.0 32.9 2.51 50.7 32.7 2.74 46.5 30.7 3.04 42.4 28.7 3.35 37.2 26.6 3.76 32.2 24.7 4.16 27.1 22.7 4.56 80 72 55.3 25.6 2.28 55.3 25.6 2.52 55.4 25.5 2.76 51.5 24.0 3.05 47.6 22.5 3.35 42.4 20.4 3.76 37.4 18.4 4.17 32.3 16.5 4.58 80 57 47.6 47.6 2.37 44.8 44.8 2.60 41.9 41.9 2.82 38.5 38.5 3.12 35.2 35.2 3.41 32.0 32.0 3.83 28.9 28.9 4.23 25.8 25.8 4.63 80 62 51.3 42.5 2.37 48.6 42.1 2.60 45.8 41.8 2.82 41.6 39.1 3.12 37.5 36.4 3.41 33.1 32.5 3.83 28.8 28.7 4.24 24.6 24.6 4.64 1400 75 62 51.2 36.2 2.37 48.7 35.8 2.60 46.3 35.3 2.82 41.9 33.0 3.12 37.6 30.6 3.42 32.1 27.5 3.83 26.8 24.5 4.23 21.5 21.5 4.63 80 67 54.1 34.4 2.38 52.9 34.9 2.61 51.8 35.3 2.85 47.2 33.0 3.14 42.7 30.8 3.44 37.1 28.5 3.85 31.6 26.3 4.25 26.1 24.1 4.65 80 72 56.6 26.5 2.38 56.2 26.7 2.62 55.8 26.8 2.86 52.2 25.4 3.15 48.6 23.9 3.45 42.8 21.7 3.86 37.1 19.7 4.26 31.5 17.6 4.66 80 57 49.5 49.5 2.47 46.4 46.4 2.70 43.4 43.4 2.93 39.9 39.9 3.22 36.5 36.5 3.51 33.3 33.3 3.93 30.1 30.1 4.33 27.0 27.0 4.73 80 62 52.3 44.6 2.47 49.8 45.0 2.69 47.3 45.4 2.92 42.7 42.0 3.22 38.1 38.1 3.51 34.1 34.1 3.93 30.1 30.1 4.34 26.2 26.2 4.74 1600 75 62 52.1 37.9 2.46 49.7 38.0 2.69 47.3 38.1 2.92 42.6 35.5 3.22 38.0 32.9 3.51 32.2 29.0 3.92 26.6 25.1 4.32 21.0 21.0 4.72 80 67 54.9 35.9 2.47 53.9 36.9 2.71 52.9 37.9 2.95 47.9 35.4 3.24 43.0 32.9 3.53 36.9 30.4 3.95 31.0 28.0 4.35 25.1 25.1 4.75 80 72 57.9 27.4 2.47 57.0 27.8 2.71 56.2 28.2 2.95 52.9 26.7 3.25 49.7 25.3 3.55 43.2 23.1 3.96 36.9 20.9 4.36 30.6 18.7 4.75 COOLING PERFORMANCE DATA - 3.5 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PHE4B4221 80 57 45.8 45.8 2.26 43.1 43.1 2.49 40.3 40.3 2.72 37.1 37.1 3.02 34.0 34.0 3.31 30.8 30.8 3.73 27.7 27.7 4.13 24.6 24.6 4.53 Johnson Controls Unitary Products 80 62 50.4 40.4 2.27 47.4 39.3 2.50 44.4 38.2 2.73 40.6 36.1 3.02 36.8 34.1 3.31 32.1 30.4 3.73 27.5 26.9 4.14 23.0 23.0 4.54 1200 75 62 50.3 34.5 2.28 47.8 33.5 2.51 45.3 32.6 2.73 41.2 30.4 3.03 37.2 28.3 3.33 32.0 26.1 3.74 27.0 24.0 4.14 21.9 21.8 4.53 9 5005568-YTG-H-1017 COOLING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PHE4B4821 80 57 48.0 48.0 2.63 45.0 45.0 2.90 42.0 42.0 3.16 39.3 39.3 3.53 36.6 36.6 3.91 33.2 33.2 4.40 29.9 29.9 4.89 26.5 26.5 5.37 80 62 51.3 44.1 2.64 48.1 41.5 2.92 44.9 38.9 3.21 41.4 36.4 3.56 37.9 34.0 3.91 34.2 32.3 4.40 30.7 30.6 4.89 27.1 27.1 5.37 1400 75 62 52.4 37.9 2.63 48.9 35.6 2.90 45.4 33.3 3.16 41.9 31.0 3.52 38.5 28.6 3.87 34.7 26.9 4.38 31.1 25.2 4.87 27.5 23.5 5.36 80 67 56.5 40.8 2.66 54.0 37.5 2.94 51.6 34.2 3.22 48.2 32.0 3.57 44.8 29.8 3.93 41.0 27.7 4.43 37.3 25.6 4.91 33.6 23.6 5.39 80 72 64.4 33.6 2.70 60.8 31.0 2.96 57.2 28.4 3.22 53.7 26.1 3.58 50.1 23.8 3.95 46.0 21.9 4.44 42.1 20.1 4.92 38.2 18.3 5.40 80 57 50.6 50.6 2.77 47.3 47.3 3.03 44.1 44.1 3.30 41.1 41.1 3.66 38.1 38.1 4.03 34.4 34.4 4.53 30.8 30.8 5.02 27.2 27.2 5.50 80 62 53.7 47.6 2.77 50.1 44.8 3.05 46.4 41.9 3.32 42.8 39.4 3.68 39.1 36.9 4.04 35.4 34.8 4.53 31.7 31.7 5.01 28.1 28.1 5.49 1600 75 62 54.5 40.5 2.77 50.9 38.1 3.03 47.3 35.7 3.30 43.5 33.2 3.65 39.7 30.8 4.01 35.9 28.9 4.51 32.1 27.1 5.00 28.3 25.2 5.48 80 67 60.0 42.6 2.80 56.8 39.6 3.07 53.5 36.6 3.35 49.9 34.3 3.70 46.4 32.0 4.06 42.2 29.7 4.56 38.1 27.5 5.04 34.0 25.3 5.52 80 72 66.5 35.0 2.82 62.7 32.6 3.09 59.0 30.1 3.35 55.3 27.7 3.72 51.5 25.3 4.08 47.3 23.4 4.57 43.3 21.5 5.05 39.2 19.7 5.53 80 57 53.1 53.1 2.91 49.7 49.7 3.17 46.2 46.2 3.43 42.9 42.9 3.79 39.7 39.7 4.16 35.7 35.7 4.66 31.8 31.8 5.15 27.9 27.9 5.64 80 62 56.1 51.0 2.90 52.0 48.0 3.17 47.9 45.0 3.44 44.1 42.4 3.81 40.4 39.8 4.17 36.5 36.5 4.66 32.8 32.8 5.14 29.0 29.0 5.62 1800 75 62 56.7 43.2 2.90 53.0 40.6 3.16 49.3 38.0 3.43 45.2 35.5 3.79 41.0 33.0 4.15 37.0 31.0 4.64 33.1 29.0 5.12 29.1 27.0 5.60 80 67 63.6 44.3 2.93 59.5 41.7 3.21 55.4 39.0 3.48 51.7 36.6 3.84 48.0 34.2 4.19 43.4 31.7 4.69 38.9 29.4 5.17 34.4 27.1 5.65 80 72 68.5 36.4 2.95 64.7 34.2 3.22 60.8 31.9 3.49 56.8 29.4 3.85 52.9 26.9 4.20 48.6 24.9 4.70 44.4 22.9 5.18 40.3 21.0 5.66 80 67 68.6 55.3 3.41 67.4 49.0 3.77 66.2 42.6 4.14 61.5 40.5 4.60 56.7 38.4 5.05 50.1 36.5 5.71 43.6 34.6 6.35 37.1 32.8 6.99 80 72 81.4 37.3 3.45 77.8 36.9 3.82 74.3 36.5 4.18 69.1 33.4 4.64 63.8 30.2 5.10 57.4 27.7 5.75 51.1 25.2 6.39 44.9 22.8 7.02 80 57 65.3 65.3 3.54 62.3 62.3 3.87 59.2 59.2 4.20 55.1 55.1 4.67 51.1 51.1 5.14 46.5 46.5 5.83 42.1 42.1 6.49 37.7 37.7 7.16 80 62 74.6 49.2 3.59 64.4 48.6 4.06 54.1 47.9 4.53 52.4 48.3 4.85 50.6 48.6 5.17 45.1 43.9 5.84 39.9 39.3 6.50 34.6 34.6 7.15 1800 75 62 70.4 50.6 3.56 65.8 48.5 3.90 61.2 46.4 4.25 56.2 44.1 4.70 51.2 41.8 5.15 44.7 38.2 5.82 38.5 34.7 6.47 32.3 31.2 7.12 80 67 70.6 60.0 3.57 69.2 53.0 3.93 67.8 46.1 4.30 62.7 43.8 4.76 57.5 41.6 5.22 50.2 39.0 5.88 43.0 36.4 6.52 35.9 33.8 7.16 80 72 80.6 38.1 3.61 78.2 37.8 3.98 75.8 37.6 4.35 70.5 34.8 4.81 65.3 32.0 5.26 58.2 29.4 5.91 51.4 26.9 6.55 44.6 24.4 7.18 80 57 69.1 69.1 3.72 65.6 65.6 4.05 62.1 62.1 4.39 57.8 57.8 4.85 53.5 53.5 5.31 48.6 48.6 5.99 43.8 43.8 6.66 39.0 39.0 7.32 80 62 74.7 52.1 3.74 62.1 48.7 4.37 49.5 45.4 5.01 50.6 48.6 5.17 51.7 51.7 5.33 46.0 46.0 6.00 40.5 40.5 6.66 35.0 35.0 7.31 2000 75 62 72.3 54.2 3.72 67.4 52.0 4.06 62.5 49.8 4.41 57.4 47.3 4.87 52.4 44.8 5.32 45.4 40.4 5.99 38.6 36.2 6.63 31.8 31.8 7.28 80 67 72.6 64.6 3.73 71.1 57.1 4.10 69.5 49.5 4.47 63.9 47.1 4.93 58.3 44.8 5.39 50.3 41.4 6.04 42.5 38.1 6.68 34.8 34.8 7.32 80 72 79.7 38.9 3.76 78.5 38.8 4.14 77.3 38.7 4.52 72.0 36.2 4.97 66.7 33.8 5.42 59.1 31.1 6.07 51.7 28.5 6.71 44.3 25.9 7.34 COOLING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER IDDB ENTERING AIR TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. S.C. 65 / 55 K.W. T.C. S.C. 75 / 63 K.W. T.C. S.C. 85 / 69 K.W. T.C. S.C. 95 / 75 K.W. T.C. S.C. 105 / 83 K.W. T.C. S.C. 115 / 89 K.W. T.C. S.C. 125 / 95 K.W. 10 PHE4B6021 80 57 61.5 61.5 3.37 58.9 58.9 3.69 56.3 56.3 4.01 52.5 52.5 4.49 48.6 48.6 4.97 44.5 44.5 5.66 40.5 40.5 6.33 36.5 36.5 7.00 80 62 74.6 46.4 3.44 66.6 48.4 3.75 58.7 50.4 4.06 54.1 47.9 4.53 49.5 45.4 5.01 44.3 41.6 5.68 39.2 37.9 6.34 34.1 34.1 6.99 1600 75 62 68.4 47.0 3.40 64.2 45.0 3.74 60.0 42.9 4.09 55.0 40.8 4.54 50.0 38.8 4.99 44.1 35.9 5.66 38.4 33.2 6.31 32.7 30.4 6.97 Johnson Controls Unitary Products 5005568-YTG-H-1017 HEATING PERFORMANCE DATA - 2 TON PACKAGED UNIT MODEL NO. PHE4A2421 AIR TEMP. ENTERING OUTDOOR COIL 60 47 40 30 17 10 AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 MBH 28.1 26.7 25.3 23.4 22.3 21.3 20.7 19.8 18.8 17.1 16.7 16.2 13.6 600 COP 4.56 3.92 3.39 4.00 3.42 2.96 3.61 3.09 2.66 3.08 2.69 2.38 2.57 KW 1.80 1.99 2.18 1.71 1.91 2.10 1.67 1.87 2.06 1.62 1.80 1.99 1.54 70 80 60 70 80 12.7 11.8 12.2 11.4 10.5 2.14 1.80 2.36 1.97 1.65 1.73 1.91 1.51 1.68 1.86 MBH 29.3 27.8 26.4 24.1 23.0 21.9 21.4 20.4 19.4 17.6 17.0 16.3 13.9 ID CFM 800 COP 5.06 4.34 3.75 4.31 3.70 3.20 3.87 3.32 2.87 3.28 2.83 2.47 2.65 KW 1.69 1.87 2.05 1.63 1.82 2.00 1.61 1.79 1.97 1.57 1.75 1.93 1.52 MBH 30.5 29.0 27.5 24.9 23.7 22.5 22.0 21.0 20.0 18.2 17.3 16.4 14.1 1000 COP 5.63 4.82 4.16 4.66 4.00 3.46 4.16 3.58 3.10 3.48 2.98 2.57 2.75 KW 1.58 1.76 1.93 1.56 1.73 1.90 1.54 1.71 1.88 1.53 1.69 1.86 1.50 12.9 12.0 12.1 11.3 10.4 2.22 1.87 2.37 1.99 1.67 1.69 1.87 1.49 1.66 1.82 13.1 12.2 12.1 11.3 10.4 2.31 1.95 2.38 2.01 1.70 1.66 1.82 1.48 1.63 1.79 KW 2.06 2.27 2.48 2.03 2.23 2.44 2.00 2.21 2.43 1.94 MBH 36.6 35.0 33.5 30.1 28.7 27.2 26.7 25.3 23.9 21.6 1200 COP 5.29 4.62 4.05 4.41 3.81 3.31 3.95 3.39 2.93 3.26 KW 2.02 2.22 2.41 1.99 2.20 2.40 1.97 2.18 2.38 1.93 2.14 2.35 1.87 2.08 2.29 1.84 2.03 2.21 20.7 19.7 15.9 14.5 13.2 13.6 12.4 11.2 2.83 2.47 2.47 2.06 1.71 2.13 1.77 1.47 2.13 2.32 1.88 2.06 2.24 1.86 2.04 2.22 HEATING PERFORMANCE DATA - 2.5 TON PACKAGED UNIT MODEL NO. PHE4A3021 AIR TEMP. ENTERING OUTDOOR COIL 60 47 40 30 17 10 AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 Johnson Controls Unitary Products MBH 34.6 33.3 32.0 29.1 27.7 26.2 25.5 24.3 23.0 21.2 800 COP 4.82 4.19 3.67 4.13 3.55 3.07 3.69 3.15 2.71 3.17 KW 2.10 2.32 2.55 2.06 2.27 2.49 2.02 2.25 2.48 1.95 MBH 35.6 34.2 32.8 29.6 28.2 26.7 26.1 24.8 23.5 21.4 ID CFM 1000 COP 5.05 4.40 3.86 4.27 3.68 3.19 3.82 3.27 2.82 3.22 20.3 19.3 16.3 14.3 12.4 13.7 12.7 11.7 2.74 2.38 2.55 2.00 1.55 2.20 1.84 1.54 2.16 2.37 1.86 2.10 2.33 1.81 2.01 2.21 20.5 19.5 16.1 14.5 12.8 13.6 12.5 11.4 2.78 2.42 2.51 2.03 1.63 2.16 1.81 1.51 11 5005568-YTG-H-1017 HEATING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. PHE4B3621 AIR TEMP. ENTERING OUTDOOR COIL AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 40 30 17 10 MBH 41.6 39.9 38.2 35.3 33.8 32.3 31.5 30.1 28.7 26.8 25.3 23.9 20.1 18.7 17.3 17.6 16.1 14.7 1000 COP 4.67 4.08 3.58 4.14 3.59 3.13 3.76 3.26 2.84 3.29 2.82 2.43 2.54 2.16 1.84 2.28 1.90 1.59 KW 2.60 2.86 3.11 2.49 2.75 3.01 2.45 2.70 2.95 2.38 2.62 2.87 2.31 2.52 2.74 2.25 2.48 2.70 MBH 42.7 40.9 39.1 35.8 34.2 32.7 32.0 30.5 29.1 27.0 25.6 24.1 20.3 18.4 16.5 17.6 16.3 14.9 ID CFM 1200 COP 4.87 4.25 3.73 4.23 3.67 3.21 3.83 3.33 2.91 3.31 2.85 2.47 2.54 2.11 1.75 2.26 1.89 1.59 KW 2.56 2.81 3.06 2.47 2.72 2.97 2.44 2.68 2.92 2.38 2.62 2.86 2.33 2.54 2.76 2.28 2.50 2.72 MBH 43.8 41.9 40.0 36.3 34.7 33.0 32.4 31.0 29.5 27.2 25.8 24.4 20.4 18.0 15.7 17.7 16.4 15.0 1400 COP 5.08 4.42 3.88 4.33 3.76 3.29 3.90 3.40 2.97 3.33 2.88 2.50 2.54 2.06 1.65 2.23 1.89 1.60 KW 2.52 2.77 3.01 2.45 2.69 2.93 2.42 2.66 2.90 2.39 2.62 2.84 2.35 2.56 2.77 2.31 2.52 2.74 MBH 49.1 46.9 44.7 40.7 38.5 36.3 35.7 33.4 31.1 27.9 26.4 25.0 22.0 19.8 17.5 17.0 16.0 14.9 ID CFM 1400 COP 4.36 3.83 3.38 3.75 3.27 2.86 3.31 2.82 2.41 2.65 2.30 2.00 2.13 1.76 1.45 1.65 1.44 1.26 KW 3.29 3.58 3.86 3.16 3.44 3.71 3.15 3.46 3.77 3.08 3.36 3.64 3.02 3.28 3.53 3.01 3.24 3.46 MBH 50.1 47.8 45.4 41.2 39.0 36.8 36.1 33.6 31.1 30.3 27.0 23.8 22.5 19.6 16.7 16.4 15.3 14.1 1600 COP 4.33 3.82 3.38 3.68 3.22 2.83 3.22 2.75 2.35 2.76 2.27 1.86 2.08 1.68 1.33 1.51 1.31 1.14 KW 3.38 3.65 3.92 3.27 3.54 3.80 3.27 3.57 3.87 3.20 3.47 3.74 3.16 3.41 3.65 3.16 3.38 3.60 HEATING PERFORMANCE DATA - 3.5 TON PACKAGED UNIT MODEL NO. PHE4B4221 AIR TEMP. ENTERING OUTDOOR COIL 60 47 40 30 17 10 12 AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 MBH 48.1 46.0 43.9 40.1 38.0 35.9 35.3 33.2 31.1 25.5 25.8 26.1 21.6 20.0 18.4 17.6 16.7 15.8 1200 COP 4.38 3.84 3.38 3.83 3.32 2.89 3.41 2.90 2.47 2.52 2.32 2.16 2.19 1.86 1.57 1.80 1.58 1.39 KW 3.21 3.50 3.79 3.06 3.34 3.63 3.02 3.35 3.67 2.95 3.24 3.53 2.87 3.14 3.41 2.85 3.09 3.32 Johnson Controls Unitary Products 5005568-YTG-H-1017 HEATING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. PHE4B4821 AIR TEMP. ENTERING OUTDOOR COIL AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 47 40 30 17 10 MBH 56.5 54.9 53.3 48.4 46.7 45.0 43.3 40.5 37.8 37.5 35.2 32.9 28.4 27.2 26.0 25.8 24.1 22.4 1400 COP 4.87 4.29 3.80 4.33 3.77 3.32 3.94 3.36 2.88 3.50 2.93 2.47 2.71 2.33 2.02 2.53 2.13 1.80 KW 3.39 3.74 4.09 3.27 3.62 3.97 3.21 3.52 3.84 3.13 3.51 3.88 3.06 3.41 3.76 2.98 3.30 3.62 MBH 57.8 56.0 54.2 49.2 47.4 45.6 43.8 41.7 39.7 37.0 34.7 32.3 28.2 27.0 25.9 25.5 24.0 22.6 ID CFM 1600 COP 4.95 4.37 3.89 4.37 3.82 3.36 3.96 3.44 3.00 3.40 2.88 2.45 2.66 2.30 2.00 2.43 2.09 1.80 KW 3.41 3.74 4.07 3.29 3.62 3.96 3.23 3.55 3.86 3.18 3.52 3.86 3.09 3.43 3.77 3.05 3.36 3.66 MBH 59.0 57.0 55.1 49.9 48.1 46.2 44.3 42.9 41.5 36.6 34.2 31.8 28.0 26.9 25.8 25.1 24.0 22.9 1800 COP 5.03 4.46 3.98 4.42 3.87 3.41 3.98 3.51 3.12 3.31 2.83 2.42 2.61 2.27 1.99 2.34 2.05 1.81 KW 3.43 3.74 4.05 3.30 3.63 3.95 3.25 3.57 3.89 3.23 3.53 3.84 3.13 3.46 3.79 3.12 3.41 3.70 MBH 71.2 68.4 65.5 58.7 56.5 54.3 52.8 50.4 48.1 38.2 37.9 37.7 32.5 30.5 28.5 29.9 28.2 26.5 ID CFM 1800 COP 4.54 3.98 3.51 3.93 3.44 3.03 3.61 3.13 2.73 2.77 2.49 2.25 2.41 2.04 1.74 2.21 1.90 1.65 KW 4.59 5.03 5.46 4.36 4.80 5.25 4.28 4.71 5.13 4.03 4.46 4.88 3.94 4.36 4.78 3.96 4.32 4.69 MBH 72.2 69.1 66.1 59.0 56.8 54.6 53.0 51.1 49.1 38.2 36.3 34.4 35.4 33.4 31.5 29.8 28.0 26.2 2000 COP 4.57 4.02 3.56 3.88 3.42 3.03 3.54 3.13 2.77 2.68 2.35 2.06 2.48 2.16 1.88 2.12 1.83 1.59 KW 4.61 5.03 5.44 4.44 4.86 5.26 4.38 4.78 5.17 4.15 4.51 4.88 4.17 4.53 4.88 4.11 4.46 4.82 HEATING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. PHE4B6021 AIR TEMP. ENTERING OUTDOOR COIL 60 47 40 30 17 10 AIR TEMP. ENTERING INDOOR COIL 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 Johnson Controls Unitary Products MBH 70.2 67.6 65.0 58.4 56.3 54.1 52.5 49.8 47.0 38.2 39.5 40.9 29.5 27.6 25.6 30.1 28.4 26.8 1600 COP 4.50 3.94 3.48 3.98 3.46 3.03 3.69 3.15 2.70 2.87 2.63 2.45 2.33 1.92 1.59 2.31 1.98 1.71 KW 4.55 5.01 5.46 4.28 4.76 5.23 4.17 4.63 5.09 3.89 4.38 4.88 3.71 4.19 4.69 3.79 4.19 4.57 13 5005568-YTG-H-1017 &2,/*8$5' +,*+92/7$*( 23(1,1*´ & +,*+92/7$*( 23(1,1*´ +($76(&7,21 $&&(663$1(/ &2035(6625 $&&(663$1(/ &21'(16$7( '5$,1 %/2:(5 $&&(66 3$1(/ % $ /2:92/7$*(23(1,1*´ &21752/+($7 $&&(663$1(/ $ UNIT DIMENSIONS Model A 51-1/4 51-1/4 51-1/4 51-1/4 51-1/4 51-1/4 PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 Dimensions B 35-3/4 35-3/4 45-3/4 45-3/4 45-3/4 45-3/4 C 47 49 49 49 53 55 UNIT CLEARANCES Direction Top1 Side Opposite Ducts Duct Panel Distance (in.) 36 36 0 Direction Right Side Left Side Bottom 2, 3 Distance (in.) 36 24 1 1. Minimum Clearance of 1inch all sides of supply air duct for the first 3 foot of duct for 20 & 25 kW., zero inches there after. For all other heaters, zero inch clearance all sides for entire length of duct. 2. Units must be installed outdoors. Over hanging structure or shrubs should not obscure outdoor air discharge outlet. 3. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. Note: For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch? between combustible roof curb material and this supply air duct. ELECTRIC HEAT MINIMUM SUPPLY AIR Model Voltage PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 14 Minimum Blower Speed for Electric Heat Heater kW 2 5 8 10 13 15 18 20 25 Low #1 Low #1 Med. Low #2 Med. #3 Med. Hi #4 ----Low #1 Low #1 Low #1 Med. Low #2 Med #3 High #5 ---Low #1 Low #1 Low #1 Low #1 Med. Low #2 High #5 ----Low #1 Low #1 Low #1 Low #1 Med. Low #2 Med. Hi #4 High #5 --Low #1 Low #1 Low #1 Low #1 Low #1 Med. Low #2 Med. High #4 --Low #1 Low #1 Low #1 Low #1 Low #1 Low #1 Med. Low #2 Med. High #4 Johnson Controls Unitary Products 5005568-YTG-H-1017 INDOOR BLOWER SPECIFICATIONS Motor Model HP 1/2 1/2 1/2 3/4 3/4 1 PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 RPM Variable Variable Variable Variable Variable Variable EFF. 0.8 0.8 0.8 0.8 0.8 0.8 SF 1.0 1.0 1.0 1.0 1.0 1.0 Frame 48 48 48 48 48 48 COOLING SOUND PERFORMANCE Model (Tons) Sound Rating1 dB (A) PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 72.4 68.7 73.2 73.6 125 61.8 58.3 61.8 62.4 250 60.5 58.8 63.2 59.0 74.0 74.1 62.0 65.9 62.0 61.8 125 64.7 57.5 60.1 62.4 66.0 61.6 250 59.2 58.0 62.5 58.3 63.3 59.4 Octave Band Centerline Frequency (Hz) 500 1000 2000 63.1 62.5 57.1 56.6 57.3 54.0 60.5 64.4 58.9 61.5 64.9 60.3 60.9 60.8 64.7 63.5 60.1 58.7 4000 51.8 48.4 53.4 55.8 8000 44.0 43.0 45.9 50.6 56.6 55.5 49.2 48.3 4000 49.2 47.6 53.0 54.4 56.4 55.1 8000 43.2 49.7 46.0 47.9 48.9 51.4 1. Rated in accordance with AHRI Standard 270. HEATING SOUND PERFORMANCE Model (Tons) Sound Rating1 dB (A) PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 PHE4B4821 PHE4B6021 70.3 69.0 72.8 73.6 74.6 73.7 Octave Band Centerline Frequency (Hz) 500 1000 2000 59.8 58.1 54.3 58.0 63.8 53.2 60.4 64.5 58.8 61.5 65.7 59.7 61.1 64.6 60.2 60.5 63.6 58.7 1. Rated in accordance with AHRI Standard 270. Johnson Controls Unitary Products 15 5005568-YTG-H-1017 ELECTRICAL DATA - 208/230-1-60 SINGLE SOURCE POWER SINGLE POINT CONNECTION KIT REQUIRED Model Compressor RLA LRA MCC OD Fan Blower Motor Motor FLA FLA PHE4A024 10 62 16 0.7 3.8 PHE4A030 14 73 22 0.6 3.8 PHE4B036 17 79 26 1.7 3.8 PHE4B042 18 112 28 1.7 5.4 PHE4B048 22 117 34 1.7 5.4 PHE4B060 24 144 38 1.7 7 1. 2. 3. 4. 16 Electric Heat Option Heater Kit4 none 6HK16500206 6HK16500506 6HK16500806 6HK16501006 6HK16501306 none 6HK16500206 6HK16500506 6HK16500806 6HK16501006 6HK16501306 6HK16501506 none 6HK16500206 6HK16500506 6HK16500806 6HK16501006 6HK16501306 6HK16501506 none 6HK16500506 6HK16500806 6HK16501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 none 6HK16500506 6HK16500806 6HK16501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 none 6HK16500506 6HK16500806 6HK16501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 Heater kW 208 -1.8 3.6 5.8 7.2 9.4 -1.8 3.6 5.8 7.2 9.4 10.8 -1.8 3.6 5.8 7.2 9.4 10.8 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 230 -2.2 4.4 7.1 8.8 11.5 -2.2 4.4 7.1 8.8 11.5 13.2 -2.2 4.4 7.1 8.8 11.5 13.2 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 Stages -1 1 1 1 2 -1 1 1 1 2 2 -1 1 1 1 2 2 -1 1 1 2 2 2 2 -1 1 1 2 2 2 2 -1 1 1 2 2 2 2 Heater Amps 208 -8.7 17.3 27.9 34.6 45.2 -8.7 17.3 27.9 34.6 45.2 51.9 -8.7 17.3 27.9 34.6 45.2 51.9 -17.3 27.9 34.6 45.2 51.9 62.5 69.2 -17.3 27.9 34.6 45.2 51.9 62.5 69.2 -17.3 27.9 34.6 45.2 51.9 62.5 69.2 230 -9.6 19.1 30.9 38.3 50.0 -9.6 19.1 30.9 38.3 50.0 57.4 -9.6 19.1 30.9 38.3 50.0 57.4 -19.1 30.9 38.3 50.0 57.4 69.1 76.5 -19.1 30.9 38.3 50.0 57.4 69.1 76.5 -19.1 30.9 38.3 50.0 57.4 69.1 76.5 MCA1 Max Fuse2 or Amps Breaker Size3 208 17.4 28.2 39.0 52.2 60.6 73.9 22.0 32.8 43.7 56.9 65.3 78.5 86.9 26.4 37.2 48.0 61.2 69.6 82.9 91.3 29.5 51.1 64.3 72.7 86.0 94.4 107.6 116.0 34.4 56.0 69.2 77.6 90.8 99.3 112.5 120.9 39.2 60.8 74.1 82.5 95.7 104.1 117.3 125.7 230 17.4 29.3 41.3 56.0 65.2 79.9 22.0 34.0 45.9 60.6 69.9 84.5 93.8 26.4 38.3 50.3 65.0 74.2 88.9 98.1 29.5 53.4 68.1 77.3 92.0 101.2 115.9 125.1 34.4 58.3 72.9 82.2 96.9 106.1 120.8 130.0 39.2 63.1 77.8 87.0 101.7 110.9 125.6 134.9 208 25 35 40 60 70 80 35 40 50 60 70 80 90 40 50 60 70 70 90 100 45 60 70 80 90 100 110 125 50 70 80 90 100 100 125 125 60 80 90 90 100 110 125 150 230 25 35 45 60 70 80 35 45 50 70 70 90 100 40 50 60 70 80 90 100 45 60 70 80 100 110 125 150 50 70 80 90 100 110 125 150 60 80 90 100 110 125 150 150 MCA = Minimum Circuit Ampacity. Maximum Over Current Protection per standard UL 1995. Fuse or HACR circuit breaker size installed at factory or field installed. Single Point Connection Kit required. Johnson Controls Unitary Products 5005568-YTG-H-1017 ELECTRICAL DATA FOR - 208-1-60 MULTI SOURCE POWER Model Compressor RLA LRA MCC OD Fan Blower Motor Motor FLA FLA Multi Source: Compressor Circuit and Heat Circuits A24 10 45 14 0.7 3.8 A30 14 57 15 0.6 3.8 B36 17 78 23 1.7 3.8 B42 18 112 28 1.7 5.4 B48 22 117 34 1.7 5.4 Electric Heat Option Multi Source Heater kW Heater Amps Heater Kit Stages 208 208 208 208 208 208 208 208 208 208 Circuit #1 Compressor Circuit Circuit #2 Heat MCA1 MCA1 MCA1 MCA1 MOP2 MOP2 MOP2 MOP2 Multi Source: Amps Amps Amps Amps Circuit #2 Heat none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK26501306 none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK26501306 6HK26501506 none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK26501306 6HK26501506 none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 -1.8 3.6 5.8 7.2 9.4 9.4 -1.8 3.6 5.8 7.2 9.4 10.8 9.4 10.8 -1.8 3.6 5.8 7.2 9.4 10.8 9.4 10.8 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 9.4 10.8 13.0 14.4 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 9.4 10.8 13.0 14.4 Circuit #3 Heat --1 8.7 1 17.3 1 27.9 1 34.6 2 45.2 1 45.2 --1 8.7 1 17.3 1 27.9 1 34.6 2 45.2 2 51.9 1 45.2 1 51.9 --1 8.7 1 17.3 1 27.9 1 34.6 2 45.2 2 51.9 1 45.2 2 51.9 1 -1 17.3 1 27.9 1 34.6 2 45.2 2 51.9 2 62.5 2 69.2 1 45.2 1 51.9 1 62.5 1 69.2 --1 17.3 1 27.9 1 34.6 2 45.2 2 51.9 2 62.5 2 69.2 1 45.2 1 51.9 1 62.5 2 69.2 Circuit #1 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 Circuit #2 --10.8 15 21.6 25 34.9 40 43.3 45 37.7 40 56.5 60 --10.8 15 21.6 25 34.9 40 43.3 45 37.7 40 43.3 50 56.5 60 64.9 70 --10.8 15 21.6 25 34.9 40 43.3 45 37.7 40 43.3 50 56.5 60 64.9 70 --21.6 25 34.9 40 43.3 45 56.5 40 43.3 50 52.1 40 43.3 45 56.5 60 64.9 70 78.1 80 86.5 90 --21.6 25 34.9 40 43.3 45 56.5 40 43.3 50 52.1 40 43.3 45 56.5 60 64.9 70 78.1 80 86.5 90 Circuit #3 ----------18.8 20 ------------18.8 20 21.6 25 --------------18.8 20 21.6 25 ------------21.6 20 21.6 25 26.0 40 43.3 45 ----------------21.6 20 21.6 25 26.0 40 43.3 45 --------- Circuit #4 --------------------------------------------------------------------------------------------------- For notes, see end of table on next page. Johnson Controls Unitary Products 17 5005568-YTG-H-1017 ELECTRICAL DATA FOR - 208-1-60 MULTI SOURCE POWER (Continued) Model Compressor RLA LRA MCC OD Fan Blower Motor Motor FLA FLA Multi Source: Compressor Circuit and Heat Circuits B60 24 144 38 1.7 7.0 Electric Heat Option Multi Source Heater kW Heater Amps Heater Kit Stages 208 208 208 208 208 208 208 208 208 208 Circuit #1 Compressor Circuit Circuit #2 Heat MCA1 MCA1 MCA1 MCA1 MOP2 MOP2 MOP2 MOP2 Multi Source: Amps Amps Amps Amps Circuit #2 Heat none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 6HK16502506 6HK26502506 -3.6 5.8 7.2 9.4 10.8 13.0 14.4 9.4 10.8 13.0 14.4 18.0 18.0 Circuit #3 Heat --1 17.3 1 27.9 1 34.6 2 45.2 2 51.9 2 62.5 2 69.2 1 45.2 1 51.9 1 62.5 1 69.2 3 86.5 1 86.5 Circuit #1 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 Circuit #2 --21.6 25 34.9 40 43.3 45 56.5 40 43.3 50 52.1 40 43.3 45 56.5 60 64.9 70 78.1 80 86.5 90 43.3 45 108.2 110 Circuit #3 --------21.6 20 21.6 25 26.0 40 43.3 45 --------43.3 45 --- Circuit #4 ------------------------21.6 25 --- 1. MCA = Minimum Circuit Ampacity. 2. MOP = Maximum Over Current Protection device; must be HACR type circuit breaker or time delay fuse. ELECTRICAL DATA FOR 230-1-60 MULTI SOURCE POWER Model Compressor RLA LRA MCC OD Fan Blower Motor Motor FLA FLA Multi Source: Compressor Circuit and Heat Circuits A24 10 45 14 0.7 3.8 A30 14 57 15 0.6 3.8 B36 17 78 23 1.7 3.8 Electric Heat Option Multi Source Heater kW Heater Amps Heater Kit Stages 230 230 230 230 230 230 230 230 230 230 Circuit #1 Compressor Circuit Circuit #2 Heat MCA1 MCA1 MCA1 MCA1 MOP2 MOP2 MOP2 MOP2 Multi Source: Amps Amps Amps Amps Circuit #2 Heat none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK26501306 none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK26501306 6HK26501506 none 6HK(0,1)6500206 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK26501306 6HK26501506 -2.2 4.4 7.1 8.8 11.5 11.5 -2.2 4.4 7.1 8.8 11.5 13.2 11.5 13.2 -2.2 4.4 7.1 8.8 11.5 13.2 11.5 13.2 Circuit #3 Heat --1 9.6 1 19.1 1 30.9 1 38.3 2 50.0 1 50.0 --1 9.6 1 19.1 1 30.9 1 38.3 2 50.0 2 57.4 1 50.0 1 57.4 --1 9.6 1 19.1 1 30.9 1 38.3 2 50.0 2 57.4 1 50.0 2 57.4 Circuit #1 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 17.4 25 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 22.0 35 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 26.4 40 Circuit #2 --12.0 15 23.9 25 38.6 40 47.8 50 41.7 45 62.5 70 --12.0 15 23.9 25 38.6 40 47.8 50 41.7 45 47.8 50 62.5 70 71.7 80 --12.0 15 23.9 25 38.6 40 47.8 50 41.7 45 47.8 50 62.5 70 71.7 80 Circuit #3 ----------20.8 25 ------------20.8 25 23.9 25 --------------20.8 25 23.9 25 ----- Circuit #4 --------------------------------------------------- For notes, see end of table on next page. 18 Johnson Controls Unitary Products 5005568-YTG-H-1017 ELECTRICAL DATA FOR 230-1-60 MULTI SOURCE POWER Model Compressor RLA LRA MCC OD Fan Blower Motor Motor FLA FLA Multi Source: Compressor Circuit and Heat Circuits B42 18 112 28 1.7 5.4 B48 22 117 34 1.7 5.4 B60 24 144 38 1.7 7.0 Electric Heat Option Multi Source Heater kW Heater Amps Heater Kit Stages 230 230 230 230 230 230 230 230 230 230 Circuit #1 Compressor Circuit Circuit #2 Heat MCA1 MCA1 MCA1 MCA1 MOP2 MOP2 MOP2 MOP2 Multi Source: Amps Amps Amps Amps Circuit #2 Heat none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 none 6HK(0,1)6500506 6HK(0,1)6500806 6HK(0,1)6501006 6HK16501306 6HK16501506 6HK16501806 6HK16502006 6HK26501306 6HK26501506 6HK26501806 6HK26502006 6HK16502506 6HK26502506 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 11.5 13.2 15.9 17.6 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 11.5 13.2 15.9 17.6 -4.4 7.1 8.8 11.5 13.2 15.9 17.6 11.5 13.2 15.9 17.6 22.0 22.0 Circuit #3 Heat 1 -1 19.1 1 30.9 1 38.3 2 50.0 2 57.4 2 69.1 2 76.5 1 50.0 1 57.4 1 69.1 1 76.5 --1 19.1 1 30.9 1 38.3 2 50.0 2 57.4 2 69.1 2 76.5 1 50.0 1 57.4 1 69.1 2 76.5 --1 19.1 1 30.9 1 38.3 2 50.0 2 57.4 2 69.1 2 76.5 1 50.0 1 57.4 1 69.1 1 76.5 3 95.7 1 95.7 Circuit #1 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 29.5 45 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 34.4 50 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 39.2 60 Circuit #2 --23.9 25 38.6 40 47.8 50 62.5 45 47.8 50 57.6 45 47.8 50 62.5 70 71.7 80 86.4 90 95.7 100 --23.9 25 38.6 40 47.8 50 62.5 45 47.8 50 57.6 45 47.8 50 62.5 70 71.7 80 86.4 90 95.7 100 --23.9 25 38.6 40 47.8 50 62.5 45 47.8 50 57.6 45 47.8 50 62.5 70 71.7 80 86.4 90 95.7 100 47.8 50 119.6 125 Circuit #3 --------23.9 25 23.9 25 28.8 45 47.8 50 ----------------23.9 25 23.9 25 28.8 45 47.8 50 ----------------23.9 25 23.9 25 28.8 45 47.8 50 --------47.8 50 --- Circuit #4 ------------------------------------------------------------------------23.9 25 --- 1. MCA = Minimum Circuit Ampacity. 2. MOP = Maximum Over Current Protection device; must be HACR type circuit breaker or time delay fuse. SINGLE POINT WIRING KIT Single Point Kit P/N Unit Model Number Breaker Size Heat Kit S1-2SPWK006 S1-2SPWK002 S1-2SPWK007 S1-2SPWK003 S1-2SPWK004 S1-2SPWK005 PHE4A24 PHE4A30 PHE4B36 PHE4B42 PHE4B48 PHE4B60 25 Amp 35 Amp 40 Amp 45 Amp 50 Amp 60 Amp up to 13 kW up to 15 kW up to 15 kW up to 20 kW up to 20 kW up to 20 kW Johnson Controls Unitary Products 19 5005568-YTG-H-1017 "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT X Y "B" A0295-001-TG WEIGHTS & DIMENSIONS Model Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) PHE4A2421 PHE4A3021 PHE4B3621 PHE4B4221 Shipping 382 397 453 476 Operating 377 392 448 471 X 29 29 29 30 Y 15 15 15 15 A 133 127 158 164 B 88 101 108 119 C 86 99 101 111 D 75 70 86 82 PHE4B4821 PHE4B6021 501 528 496 523 29 30 15 15 168 177 130 136 119 128 84 87 20 Johnson Controls Unitary Products 5005568-YTG-H-1017 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION Model 24 30 36 42 48 60 1. 2. 3. 4. 5. Motor Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 791 849 927 999 1176 768 941 1026 1112 1176 1108 1283 1362 1403 1623 0.2 SCFM 739 801 882 958 1143 715 898 987 1076 1143 1050 1225 1308 1347 1569 0.3 SCFM 727 789 871 948 1133 702 887 977 1067 1133 984 1168 1252 1290 1519 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 1436 1544 1573 1681 1935 1620 1694 1798 1835 2146 1730 1858 2054 2195 2445 1382 1492 1523 1640 1887 1564 1630 1722 1758 2085 1682 1807 1998 2144 2388 1342 1455 1484 1599 1834 1517 1580 1669 1703 2025 1628 1749 1934 2098 2306 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 668 614 564 518 733 683 635 590 819 772 727 683 899 855 812 769 1092 1052 1014 976 642 586 536 490 836 789 744 701 930 886 844 802 1023 982 942 902 1092 1052 1014 976 921 857 791 726 1115 1054 993 924 1199 1142 1079 1015 1235 1177 1118 1058 1470 1418 1362 1306 1304 1416 1445 1557 1788 1466 1530 1620 1653 1960 1592 1710 1890 2049 2293 1262 1376 1408 1517 1743 1418 1482 1572 1604 1872 1552 1667 1843 2003 2235 1220 1336 1367 1478 1701 1360 1430 1527 1558 1862 1517 1629 1801 1955 2178 1179 1294 1327 1436 1651 1308 1380 1480 1511 1798 1479 1589 1757 1883 2129 0.8 SCFM 439 512 607 696 908 409 625 729 832 908 660 860 979 995 1.0 SCFM 279 356 456 549 771 248 475 584 692 771 528 733 905 869 1246 1131 1248 1279 1393 1591 1206 1292 1413 1442 1735 1439 1546 1710 1868 2077 1125 1035 1156 1183 1307 1471 1002 1116 1280 1304 1609 1359 1460 1616 1838 1973 Airflow tested with dry coil conditions, without air filters, at 230 volts. Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 21 5005568-YTG-H-1017 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION Model 24 30 36 42 48 60 1. 2. 3. 4. 5. 22 Motor Speed Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 0.1 SCFM 791 851 938 1069 1207 768 943 1039 1190 1207 1127 1306 1354 1397 1634 0.2 SCFM 755 813 905 978 1182 730 911 1013 1099 1182 1082 1265 1315 1348 1591 0.3 SCFM 745 801 890 969 1185 720 900 998 1090 1185 1021 1205 1259 1297 1548 Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) High (5) 1455 1566 1565 1675 1946 1598 1663 1789 1931 2131 1655 1766 1987 2114 2369 1414 1532 1530 1641 1909 1548 1612 1733 1814 2058 1612 1720 1933 2050 2308 1379 1492 1491 1606 1863 1502 1568 1670 1808 1998 1596 1667 1861 2047 2249 External Static Pressure (Inches WC) 0.4 0.5 0.6 0.7 SCFM SCFM SCFM SCFM 686 632 585 537 743 692 648 603 836 788 745 702 921 872 830 787 1122 1106 1066 1023 659 604 555 508 847 800 759 716 949 905 865 825 1048 1002 963 923 1122 1106 1066 1023 952 889 825 759 1154 1094 1029 963 1212 1153 1093 1024 1256 1195 1135 1077 1497 1446 1382 1309 1335 1455 1458 1578 1815 1454 1522 1650 1736 1949 1531 1629 1817 1974 2183 1294 1416 1419 1535 1771 1410 1476 1596 1673 1892 1461 1632 1820 1899 2126 1254 1372 1381 1495 1721 1362 1422 1578 1650 1840 1462 1539 1715 1889 2088 1212 1333 1336 1455 1654 1307 1370 1535 1597 1788 1429 1537 1725 1920 2034 0.8 SCFM 455 524 623 713 952 424 641 748 853 952 689 892 990 1014 1.0 SCFM 290 367 465 565 810 258 490 596 713 810 549 751 920 888 1250 1160 1280 1290 1412 1595 1251 1297 1483 1519 1728 1391 1498 1651 1866 1990 1131 1056 1174 1198 1326 1477 1139 1152 1379 1362 1608 1316 1421 1504 1758 1902 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5005568-YTG-H-1017 ADDITIONAL STATIC RESISTANCE Size (Tons) 24 (2.0) 30 (2.5) 36 (3.0) 42 (3.5) 48 (4.0) 60 (5.0) CFM 500 600 700 800 900 1000 1100 1200 700 800 900 1000 1100 1200 1300 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 BOTTOM DUCT DIMENSIONS (Inches) 1 Wet Indoor Coil Economizer 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 Filter/Frame Kit 0.01 0.02 0.04 0.06 0.08 0.10 0.13 0.16 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 ' 9,(:/22.,1*83 $7%277202)81,7 & $ 5(7851 $,5'8&7 ( % +2/(´ IRUKLJKYROWDJH $ +2/(´ IRU ORZYROWDJH 6833/< $,5'8&7 ) Model 24, 30 36, 42, 48, 60 A 10 14 B 21.5 13.5 $ C 5 5 D 4.5 3.5 E 47.5 47.5 F 32 42 REAR DUCT DIMENSIONS (Inches) 127(6HH)LJXUHWLWOHG³8QLW'LPHQVLRQV´IRUVLGHKROHVL]HVRI HOHFWULFDOOLQHV 6833/< $,5'8&7 5(7851 $,5'8&7 $ Model 24, 30 36, 42, 48, 60 $ % A 9.6 13.6 $ B 22 14 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. Johnson Controls Unitary Products 23 5005568-YTG-H-1017 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324-001 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN CONTROL WIRING TO INDOOR THERMOSTAT 24 A0390-001 Johnson Controls Unitary Products 5005568-YTG-H-1017 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT Johnson Controls Unitary Products SUPPLY AIR DUCT A0389-001 25 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2017 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5005568-YTG-H-1017 Supersedes: 5005568-YTG-G-0717
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement