UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S TERPIECE ® SER I ES G E N E RA L P RO P E RT I E S F E ATURES & BEN EF I TS -1 8" telescopic design rises to capture heat, smoke, grease, and steam Operating Mode Convertible: Ducted / Recirculating Maximum CFM Blower Sold Separately Number of Speed Settings 3-Stage Sones* 1.2 LS / 10.5 HS Motor Location External Number of Lights 2 Bulb Type White LED Damper Included No Grease Filter Material Washable Synthetic Grease Filter Type Multilayer Cassette - Beautiful illumination with white multiple level LED lighting T E CH N I CA L D E TA I L S -F lexible discharge design gives 6 configurations to maximize space Current (A) 10 A Volts (V) 120 V Frequency (Hz) 60 Hz Plug Type 120V-3 prong Power Cord Length (in) 30" -R emote or inline blowers to reduce noise, integral for top performance - Features automatic mode, delay shut-off, and check filter light B LOWERS AN D TRAN SI TI O N S DIMENSIONS & WEIGHT Remote Blowers Overall Appliance Dimensions (Width of Canopy Included) (HxWxD) (in) 47 3/8" x 37" x 2 3/4" VTR630W – 600 CFM Height of the Rise (in.) 18" VTR1030W – 1000 CFM Diameter of Air Duct (in.) Internal 8" VTR1330W – 1300 CFM Diameter of Air Duct (in.) External 6", 8" or 10" Inline Blowers Net Weight (lbs) 47 lbs VTI610W – 600 CFM A CCE S S O RI E S ( RE Q U I RE D ) VTI1010W – 1000 CFM Blower (Sold Separately) Flexible Blower WA RRA N T Y VTD600P – 600 CFM Limited Warranty Parts and Labor 2 Year Remote and Inline Blower Downdraft Transitions CVTSIDE6 – 6" Side / Rear Transition CVTSIDE8 – 8" Side / Rear Transition CVTSIDE10 – 10" Side / Rear Transition CVTFRONT6 – 6" Round Front Plate CVTFRONT8 – 8" Round Front Plate CVTFRONT10 – 10" Round Front Plate A CCE S S O RI E S ( O P T I O N A L ) Recirculation Kit – Use with induction/electric cooktops only UCVRECIRC Replacement Charcoal Filters UCVFILTER CVDUCT2 – 2' Rectangular Duct Downdraft Gas Cooktop Seal Trim Kit (Required for Installation with Gas Cooktops) CVTRECT2 – Transition for Rectangular Duct UCV36ST 5 ft. Electrical Panel Extension Cable EXTNCE5 Roofplates RFPLT600P – For Use with Remote Blower VTR630W RFPLT1000P – For Use with 1000 CFM Remote Blower VTR1030W and 1300 CFM Blower VTR1330W 25 ft. Blower Connector Cable *Sound test performed as per HVI standards at independent lab. For use with the following inline, remote and flexible blowers: VTR630W, VTR1030W, VTR1330W, VTI610W, VTI1010W, VTD600P Page 1 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES H OOD DIMEN SION S Page 2 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES CU T OUT AN D CLEARAN C E DI M EN SI O N S Page 3 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES E LE CTRIC OR IN DUCTI O N C O O K TO P C UTO UT AN D CL E A RA N CE D I M E N S I O N S 25-7/16" - 25-9/16" (646 - 649) Template 2-1/8" (54) 22-11/16" - 22-13/16" (576 - 579) Downdraft cutout width: 30" (762) is 27-1/16" (687) 36" (914) is 33-1/16" (840) 19-7/8" - 20" (505 - 508) 11/16" (17) BT MIN. 1/2" (13) Cooktop cutout width 2-1/4" (57) GA S COOKTOP CUTO UT AN D C L EAR AN C E DI M ENS I O N S Template 2-1/8" (54) 24-11/16" (628) 22-5/16" (567) Downdraft cutout width: 30" (762) is 27-1/16" (687) 36" (914) is 33-1/16" (840) 19-1/8" (486) 1-1/16" (27) BT MIN. 1/2" (13) Cooktop cutout width 1-7/8" (48) Page 4 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N AVAILABLE REMOTE B L O WER S V T R 6 3 0W – 600 CFM VTR 1 0 30 W – 1 0 0 0 CF M AVAILABLE IN LIN E BL O WER S V T I6 1 0W – 600 CFM V T R1 3 3 0 W – 1 3 0 0 CF M AVA I L A BL E F L E XI BL E B LO W ER VTI 1 0 1 0 W – 1 0 0 0 CF M V T D 6 0 0 P – 6 0 0 CF M 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) 11 5/8" (295 mm) 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) AVAILABLE ROOFPL ATES R F P LT 600P – FOR US E WI TH R E MOTE BLOWER VTR 6 3 0 W R FPLT1 00 0 P – F O R U S E W I T H 1 0 0 0 CF M RE M O T E BL O W E R VTR 1 0 3 0 W A N D 1 3 0 0 CF M BL O W E R V T R1 3 3 0 W Page 5 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N C O NT I N U E D B LOWER DOWN DRA FT TR AN SI TI O N S C VTSI D E6 6" round transition allows for left, right, or rear venting. Use with inline and remote blowers, and ducting with 6" round duct connections. CV T F RO NT 6 6" front rough-in plate allows for front venting. Use with inline and remote blowers, and ducting with 6" round duct connections. C VTSI D E8 8" round transition allows for left, right, or rear venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. CV T F RO NT 8 8" round front plate allows for front downward venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. C VTSI D E1 0 10" round transition allows for left, right, or rear venting. Use with inline and remote blowers, and ducting with 10" round duct connections. CV T F RO NT 10 10" front rough-in plate allows for front venting. Use with inline and remote blowers, and ducting with 10" round duct connections. C VD UC T2 Rectangular 2 ft. long x 1 7/8 in deep x 19 in wide duct. CVDUCT2 transition required to directly connect CVDUCT2 to sides or rear of downdraft housing. Can be used as an extension to exhaust through a cabinet or wall, and can be cut to modify length. For use with installation of inline or remote blower applications with CVTSIDE6, CVTSIDE8, and CVTSIDE10. Page 6 of 13 CV T RE CT2 Transition required to connect CVDUCT2 rectangular duct to downdraft housing at left, right, or rear 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N C O NT I N U E D OP T I O N AL ACCESSO R I ES RE P L A CE M E N T CH A RCO A L F ILT ER U CV F I LT E R Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit R EC I R C UL ATI O N KI T UC VR EC I R C E XT N CE 5 Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. E XT N CB2 5 W For use with the following inline, remote and flexible blowers: VTR630W, VTR1030W, VTR1330W, VTI610W, VTI1010W, VTD600P D O WN DR AFT G A S C O O K TO P SE A L T RI M K I T UC V3 6 ST Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. Page 7 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES F LE XIBLE BLOWER I N STAL L ATI O N – FR O N T EX H A U S T E XA M P L E 103/8" (264 mm) RE Q U I RE D BL O W E R 103/8" (264 mm) 123/4" (324 mm) 123/4" (324 mm) 11 5/8" (295 mm) 51/8" (130 mm)5 11 5/8" (295 mm) V T D 6 0 0P – 600 CF M 600 CFM flexible blower can be installed as an 11 5/8" integrated or inline blower (295 mm) 11 /8" (295 mm) 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 5" 123/4" (127 mm) (324 mm) 73/8" (187 mm) 51/4" (133 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) O P T I O N A L A CCE S S O RI E S A P P LICATION RE CI RCULAT IO N KIT U CV RE C IR C - Front downward application with space under floor line for ductwork* - Integral blower with front downward application can be used with optional recirculation kit* Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only - Integral blower can rotate for left or right exhaust - Elbow and ductwork are not included D O W N DR A F T GA S CO O KT OP S EA L T R IM KI T U CV 36S T Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. RE P L A CE M E N T CH A RCO A L F ILT ER U CV F I LT E R Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit E XT N CE 5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. *For only front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. Page 8 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES (4) BOLTS elected,F LEBLOWER XIBLE BLOWER I N STAL L ATI O N – FR O N T EX H A U S T W I T H F L E XI BL E BL O W E R BE L O W F L O O R L I N E E XA MPLE SUPPORT LEGS 103/8" RE Q U I RE(264 D BL OWER mm) 123/4" 103/8" (324 mm) (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) 600 CFM flexible blower can be installed as an 11 5/8" integrated or inline blower (295 mm) 51/8" (130 mm) on g 11 5/8" (295 mm) 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 5" 123/4" (127 mm) (324 mm) on - V T D 6 0 0 P – 600 CF M 11 5/8" (295 mm) 73/8" (187 mm) 51/4" 73/8" (187 mm) (133 mm) 1 5 /4" (133 mm) measurements in inches (mm) measurements in inches (mm) RE Q U I RE D A CCE S S O RI E S 5. this time. B - Installation using inline or remote blowers - with ducting through front panel opening CV T F RO NT 8 8" round front plate allows for front downward venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. A P P LICATION CAUTION - Front downward application with space under floor line for ductwork* - Elbow and for ductwork not be included alone support.are It may necessary to add extra support for 6", 8", OR 10” (152MM, 203MM, OR 254MM) ROUND REMOTE ROUGH-IN PLATE (Purchase Separately) O P T I O N A L A CCE S S O RI E S FRONT PANEL D O W N D R A F T GA S CO O KT O P S EA L T R IM KI T U CV36S T If blower discharge is down, electrical panel must be relocated. Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. E XT N CE 5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. 1. Remove hex nuts to remove front panel cover. 2. If blower discharge is down, remove (4) #8-32 hex nuts and 3. Place 6”, 8”, or 10” (152mm, 203mm, or 254mm) round rough-in plate (purchase separately) over studs around front panel opening. 4. Tighten hex nuts to secure remote discharge plate in place. *For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. Page 15 Page 9 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES F LE XIBLE BLOWER I N STAL L ATI O N – L EFT O R R I GH T S I D E E XH A U S T E XA M P L E A P P L I CAT I O N - Left or right side exhaust options to preserve precious kitchen storage space or if ducting is more convenient for these configurations* - Requires at least 18" of clearance to fit the blower and transition - Blower must be accessible for maintenance - Elbow and ductwork are not included RE Q U I RE D BL O W E R 1033/8" 10 mm) /8" (264 (264 mm) 1233/4" 12 mm) /4" (324 (324 mm) RE Q U I RE D A CCE S S O RY 11 55/8" 11 mm) /8" (295 (295 mm) Left Side Exhaust 11 55/8" 11 mm) /8" (295 (295 mm) 511/8" 5 mm) /8" (130 (130 mm) 5" mm) 1233/4" (1275" (127 mm) 12 mm) /4" (324 (324 mm) 733/8" 7 mm) /8" (187 511/4" (187 mm) 5 / 4 " (133 mm) (133 mm) measurements in inches (mm) measurements in inches (mm) V T D 6 0 0 P – 6 0 0 CF M 600 CFM flexible blower can be installed as an integrated or inline blower Right Side Exhaust CV T S I D E 8 8" round transition allows for left or right venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. OP T I O N AL ACCESSO R I ES R EC I R C UL ATI O N KI T UC VR EC I R C Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only. EXTNC E5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. RE P L A CE M E N T CH A RCO A L F I LT ER U CV F I LT E R Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit D O W N D RA F T G A S CO O KT O P SEA L T RI M KI T U CV 3 6 S T Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. *For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and/or ductwork. Refer to installation manual. Page 10 of 13 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES F LE XIBLE BLOWER I N STAL L ATI O N – R EAR O R DO W N WA RD E XH A U S T E XA M P L E A P P L I CAT I O N - Rear or downward exhaust options to preserve precious kitchen storage space or if ducting is more convenient for these configurations* - Requires at least 18" of clearance to fit the blower and transition - Blower must be accessible for maintenance - Elbow and ductwork are not included RE Q U I RE D BL O W E R 1033/8" 10 mm) /8" (264 (264 mm) 1233/4" 12 mm) /4" (324 (324 mm) 11 55/8" 11 mm) /8" (295 (295 mm) 11 55/8" 11 mm) /8" (295 (295 mm) 511/8" 5 mm) /8" (130 (130 mm) Rear Exhaust RE Q U I RE D A CCE S S O RY 5" mm) 1233/4" (1275" (127 mm) 12 mm) /4" (324 (324 mm) 733/8" 7 mm) /8" (187 511/4" (187 mm) 5 / 4 " (133 mm) (133 mm) measurements in inches (mm) measurements in inches (mm) V T D 6 0 0 P – 6 0 0 CF M 600 CFM flexible blower can be installed as an integrated or inline blower CV T S I D E 8 8" round transition allows for rear or downward venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. *For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and/or ductwork. Refer to installation manual. Downward Exhaust OP T I O N AL ACCESSO R I ES R EC I R C UL ATI O N KI T UC VR EC I R C Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only. EXTNC E5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. Page 11 of 13 RE P L A CE M E N T CH A RCO A L F I LT ER U CV F I LT E R Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit D O W N D RA F T G A S CO O KT O P SEA L T RI M KI T U CV 3 6 S T Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES F LE XIBLE BLOWER I N STAL L ATI O N – SI DE EX H AU S T W I T H S L I M 2 ' RE CTA N G U L A R D U CT E XA M P L E A P P L I CAT I O N - Side exhaust option to preserve precious kitchen storage space or if ducting is more convenient for this configuration* - A slim 2' rectangular duct is available to place flexible blower in areas such as unused corner in island or peninsula applications - Blower must be accessible for maintenance - Elbow and ductwork are not included 103/8" (264 mm) RE Q U I RE D BL O W E R 123/4" (324 mm) 103/8" (264 mm) 11 5/8" (295 mm) 123/4" (324 mm) 51/8" (130 mm) 51/8" (130 mm) RE QUIRED ACCESSO R I ES 5" 123/4" (127 mm) (324 mm) C VTSI D E8 8" round transition to connect CVDUCT2 to VTD600P. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. 11 5/8" (295 mm) 5" 123/4" (127 mm) (324 mm) 11 5/8" (295 mm) V TD600P – 6 00 CF M 600 CFM flexible 11 5/8" blower can be mm) (295 installed as an integrated or inline blower3 7 /8" (187 mm) 51/4" (133 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) O P T I O N A L A CCE S S O RI E S RECIR CU LAT IO N KI T U CVR ECIR C C VDUC T2 Rectangular 2 ft. long x 1 7/8 in deep x 19 in wide duct. CVDUCT2 transition required to directly connect CVDUCT2 to sides or rear of downdraft housing. Can be used as an extension to exhaust through a cabinet or wall, and can be cut to modify length. For use with installation of inline or remote blower applications with CVTSIDE6, CVTSIDE8, and CVTSIDE10. Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only RE P L A CE M E N T CH A RCOA L F ILT ER U CV F I LT E R Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit D O W N D RA F T G A S CO O KT O P S EA L T RI M KI T U CV 3 6 S T C VTR EC T2 Transition required to connect CVDUCT2 rectangular duct to downdraft housing at left, right, or rear *For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. NOTE: Some applications may require deeper cabinets. Refer to installation manual. Page 12 of 13 Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. E XT N CE 5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. 9 / 19 UCVP36XS 3 6 - I N C H D E L U X E D O W N D R A F T V E N T I L AT I O N MA S T ERPIECE ® SERIES F LE XIBLE BLOWER I N STAL L ATI O N – R EC I R C UL AT I O N E XA M P L E RE Q U I RE D BL O W E R 103/8" (264 mm) 123/4" (324 mm) 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) 11 5/8" V T D 6 0 0(295 P –mm) 600 CF M 600 CFM flexible blower can be installed as an 5/8" integrated or11inline blower (295 mm) 51/8" (130 mm) 11 5/8" (295 mm) 5" 73/8" 123/4" (127 mm) (187 mm) (324 mm) 51/4" (133 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) RE Q U I RE D A CCE S S O RI E S A P P LICATION RE CI RCULAT IO N KIT U CV RE C IR C -A llows for non-ducted downdraft installation by eliminating the need to exhaust to the exterior of the home* Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction/electric cooktops only -R ecirculation module and metal grill vent plate placement can be rotated for flexible exhaust placement - Elbow and ductwork are not included - Use with induction/electric cooktops only EXHAUST THROUGH CABINET SIDE N B O X 14 1/2” EXHAUST THROUGH CABINET SIDE O P T I O N A L A CCE S S O RI E S RE P L A CE M E N T CH A RCO A L FILT ER U CV F I LT E R 14 1/2” (368) (368) of exhaust. recirculation box inlet will align. Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit opening in cabinet base. ing. nsert exhaust end down into opening. 15” 3 1/2" (89) x 14 1/4" (362) t. (380) toe space, rear, or side of cabinet. EXHAUST OPENING 15” DECORATIVE 3 1/2" (89) x 14 1/4" (362) (380) GRILLEEXHAUST OPENING . EXHAUST THROUGH CABINET BACK ecorative grille. n cabinet base. ot 83) x 14” (356) duct extension (not n box outlet toMeasurements decorative grille in inches (mm). and tape to make them secure and minum Measurements in inches (mm).14 1/2" DECORATIVE GRILLE D O W N D RA F T G A S CO O KT O P S EA L T R IM KI T U CV 3 6 S T Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. EXHAUST THROUGH CABINET BACK E XT N CE 5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. 14 1/2" (368) (368) e. e recirculation box to cabinet base. 15" (380) blower exhaust to recirculation box x 3 1/2" (89) x 14 1/4" (362) DECORATIVE inum tape to make them secure and EXHAUST OPENING DECORATIVE and GRILLE GRILLE of s recirculation box and attach legs 5” screws. 15" (380) 3 1/2" (89) x 14 1/4" (362) EXHAUST OPENING *For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. DIMENSIONS DIMENSIONS 16” 16” 16” (406) 17 rights 1/2” These warranties(406) give you specific legal other that vary from state to state. Full warranty and limited warranty from date of installation. For complete warranty 16” rights 17 1/2”and you may have (406) (445) (406) 8” your dealer. details, refer to your ask 8” Use & Care manual, or(445) (203) (203) 4 1/2” OPTIONAL REMOTE BLOWER 4 1/2” MOUNT UNT (114) (114) Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation ower mounted to 3 1/4” 3 1/4” For the most detailed information, engineer for your specific ventilation requirements. refer to installation instructions accompanying product or write to Thermador indicating the model (83) aming in remote (83) location - usingnumber. Specifications are correct at time6 1/2” of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada. 3 3/4” 6 1/2” 3 3/4” (165) (95) ounting brackets. Thermador is (165) not responsible for products that are transported from 14”the U.S. for use in Canada. (95) 14” (356) 12 1/4” Blower outlet and (356) Measurements 12 1/4” BLOWER (311) recirculation box1 800 Measurements 735 4328 | USA(311) THERMADOR.COM | CANADA THERMADOR.CA | 15” ©2019 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED. in inches (mm). 15” (380) in inches (mm). inlet must align. (380) 16” (See below.) 16” (406) ETAL 8” ROUND DUCT (per local codes) (406) Page 13 of 13 9 / 19
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement