Thermador VCIN36GWS 36-Inch Professional Custom Insert Specification Sheet

Thermador VCIN36GWS 36-Inch Professional Custom Insert Specification Sheet
VCIN36GWS
36-INCH CUSTOM INSERT
P R OFESSION AL ® SER I ES
G E N E RA L P RO P E RT I E S
Features
Multi-Level LED Lights with Fading Transitions, Automatic Mode, Check
Filter Reminder Light, Delay Shut-Off
F E ATURES & BEN EF I TS
-R
evel in creative freedom with Professional® Series custom
inserts that can blend in with cabinetry or make a bold
statement
- Equipped with the Thermador Connected Experience by
Home Connect™
Operating Mode
Ducted
Maximum CFM
Blower Sold Separately
Number of Speed Settings
4-Stage
Number of Lights
2
Bulb Type
LED
Total Power of the Lamps (W)
2.4 W
Damper Included
Yes
Grease Filter Material
Washable Stainless
Steel
Grease Filter Type
Stainless-Steel
Commercial Style
Baffle Filter
Home Connect™ (Wi-Fi Enabled)
Yes
-P
owerfully Quiet® system accepts integral, inline, and
remote blowers
T E CH N I CA L D E TA I L S
Watts (W)
See Chart on Page 3
- Beautiful illumination with multi-level, vivid LED lights
Current (A)
See Chart on Page 3
-F
eatures automatic mode, delay shut-off, and check filter
light
Volts (V)
120 V
Frequency (Hz)
60 Hz
Plug Type
Fixed Connection
Power Cord / Conduit Length (in)
Direct Wire at
Junction Box
A C C ESSORIES ( OPT I O N AL )
25 ft. Blower Connector Cable - EXTNCB25W
For use with the following inline and remote blowers: VTR630W,
VTR1030W, VTR1330W, VTI610W, VTI1010W
Roofplates
RFPLT600P - For use with 600 CFM remote blower VTR630W
RFPLT1000P - For use with 1000 CFM remote blower
VTR1030W and 1300 CFM blower VTR1330W
DIMENSIONS & WEIGHT
Overall Appliance Dimensions
(Width of Canopy Included) (HxWxD) (in)
12 13/16" x 33 3/4" x
22"
Minimum Required Distance Above Gas /
Electric Cooking Surface
30" Electric / 30" Gas
Diameter of Air Duct (in.) Top
10"
VCIN Trim Notes
Net Weight (lbs)
54 lbs
NOTE: VCIN_GWS series custom insert models include hood
trim pieces to complete the installation.
A CCE S S O RI E S ( RE Q U I RE D )
Remote Control Panel
REMCPW - Ability to vertically install on cabinetry or wall to
control hood in a convenient location
Blower (Sold Separately)
BL O W E R O P T I O N S
Remote Blowers
(Mounted to Roof or External Wall)
VTR630W - 600 CFM
VTR1030W - 1000 CFM
VTR1330W - 1300 CFM
Inline Blowers
(Mounted Between Kitchen and External Wall)
VTI610W - 600 CFM
Integrated Blower (Mounted in Hood)
VTN630W - 600 CFM
VTI1010W - 1000 CFM
VTN1090R - 1000 CFM
WA RRA N T Y
Limited Warranty Parts and Labor
2 Year
THERMADOR® EXCLUSIVE
Page 1 of 5
3 / 19
VCIN36GWS
36-INCH CUSTOM INSERT
P R OF ESSION AL ® SER I ES
H OOD DIMEN SION S
NOTE: VCIN Custom Insert models include hood trim pieces.
OP T I O N AL ACCESSO R I ES
R E MOT E CON TROL PANEL
R E MC P W
Convenience at your fingertips: The remote
control accessory offers the freedom to extend
your hood controls to a more reachable spot
Page 2 of 5
3 / 19
VCIN36GWS
36-INCH CUSTOM INSERT
P R OF ESSION AL ® SER I ES
ELECTRIC LOAD
MODEL
DESCRIPTION
VCIN36GWS
36" Custom Insert
VTN630W
VTN1090R
VTI610W
VTI1010W
VTR630W
VTR1030W
VTR1330W
Amps
4.0
7.4
5.9
7.8
5.9
7.8
11.3
Watts
480
888
708
936
708
936
1,356
R E MOTE BLOWERS ( M O UN TED TO R O O F O R EX T E RN A L WA L L )
V T R1 0 3 0 W – 1 0 0 0 CF M
V T R 6 3 0W–600 CFM
V T R 1 3 30W–1300 CFM
Page 3 of 5
3 / 19
VCIN36GWS
36-INCH CUSTOM INSERT
P R OF ESSION AL ® SER I ES
INLI NE BLOWERS ( MO UN TED B ETWEEN K I TC H EN A N D E XT E RN A L WA L L )
V T I6 1 0W–600 CFM
V T I 1 0 1 0 W – 1 0 0 0 CF M
INT E GRATED BLOWE R S ( M O UN TED I N H O O D )
V T N6 30W–600 CFM
V T N 1 0 9 0 R– 1 0 0 0 CF M
Page 4 of 5
3 / 19
VCIN36GWS
36-INCH CUSTOM INSERT
P R OF ESSION AL ® SER I ES
R E MOTE BLOWER AC C ESSO R I ES
R OOF PLATE–RFPLT60 0 P
R O O F P L AT E – RF P LT 1 0 0 0 P
E XT N CB2 5 W
For use with the following Inline and
Remote Blowers: VTR630W, VTR1030W,
VTR1330W, VTI610W, VTI1010W
These warranties give you specific legal rights and you may have other rights that vary from state to state. Full warranty and limited warranty from date of installation. For complete warranty
details, refer to your Use & Care manual, or ask your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation
engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model
number. Specifications are correct at time of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products that are transported from the U.S. for use in Canada.
1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2020 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED.
Page 5 of 5
3 / 19
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement