Thermador UCVM36XS 36" Masterpiece Downdraft, 15" Snorkle Specification Sheet

Thermador UCVM36XS 36" Masterpiece Downdraft, 15" Snorkle Specification Sheet
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S TERPIECE ® SER I ES
G E N E RA L P RO P E RT I E S
F E ATURES & BEN EF I TS
-1
5" telescopic design rises to capture heat, smoke, grease, and
steam
Operating Mode
Convertible: Ducted /
Recirculating
Maximum CFM
Blower Sold Separately
Number of Speed Settings
3-Stage
Sones*
1.2 LS / 10.5 HS
Motor Location
External
Number of Lights
N/A
Damper Included
No
Grease Filter Material
Washable Synthetic
Grease Filter Type
Multilayer Cassette
T E CH N I CA L D E TA I L S
Current (A)
10 A
Volts (V)
120 V
Frequency (Hz)
60 Hz
- Features automatic mode, delay shut-off, and check filter light
Plug Type
120V-3 prong
-R
ecirculation kit available, use with induction/electric cooktops
only
Power Cord Length (in)
30"
-F
lexible discharge design gives 6 configurations to maximize
space
-R
emote or inline blowers to reduce noise, integral for top
performance
B LOWERS AN D TRAN SI TI O N S
Remote Blowers
VTR630W – 600 CFM
VTR1030W – 1000 CFM
VTR1330W – 1300 CFM
Inline Blowers
VTI610W – 600 CFM
VTI1010W – 1000 CFM
Flexible Blower
DIMENSIONS & WEIGHT
Overall Appliance Dimensions
(Width of Canopy Included) (HxWxD) (in)
44 3/8" x 37" x 2 3/4"
Height of the Rise (in.)
15"
Diameter of Air Duct (in.) Internal
8"
Diameter of Air Duct (in.) External
6", 8" or 10"
Net Weight (lbs)
47 lbs
A CCE S S O RI E S ( RE Q U I RE D )
Blower (Sold Separately)
WA RRA N T Y
Limited Warranty Parts and Labor
2 Year
VTD600P – 600 CFM
Remote and Inline Blower Downdraft Transitions
A CCE S S O RI E S ( O P T I O N A L )
CVTSIDE6 – 6" Side / Rear Transition
Recirculation Kit – Use with induction/electric cooktops only
CVTSIDE8 – 8" Side / Rear Transition
UCVRECIRC
CVTSIDE10 – 10" Side / Rear Transition
Replacement Charcoal Filters
CVTFRONT6 – 6" Round Front Plate
UCVFILTER
CVTFRONT8 – 8" Round Front Plate
Downdraft Gas Cooktop Seal Trim Kit (Required for Installation with Gas
Cooktops)
CVTFRONT10 – 10" Round Front Plate
CVDUCT2 – 2' Rectangular Duct
CVTRECT2 – Transition for Rectangular Duct
UCV36ST
5 ft. Electrical Panel Extension Cable
EXTNCE5
Roofplates
RFPLT600P – For Use with Remote Blower VTR630W
RFPLT1000P – For Use with 1000 CFM Remote Blower VTR1030W and
1300 CFM Blower VTR1330W
25 ft. Blower Connector Cable
For use with the following inline, remote and flexible blowers: VTR630W,
VTR1030W, VTR1330W, VTI610W, VTI1010W, VTD600P
*Sound test performed as per HVI standards at independent lab.
Page 1 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
H OOD DIMEN SION S
Page 2 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
CU T OUT AN D CLEARAN C E DI M EN SI O N S
Page 3 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
E LE CTRIC OR IN DUCTI O N C O O K TO P C UTO UT AN D CL E A RA N CE D I M E N S I O N S
25-7/16" - 25-9/16"
(646 - 649)
Template
2-1/8" (54)
22-11/16" - 22-13/16"
(576 - 579)
Downdraft cutout width:
30" (762) is 27-1/16" (687)
36" (914) is 33-1/16" (840)
19-7/8" - 20"
(505 - 508)
11/16"
(17)
BT
MIN.
1/2"
(13)
Cooktop cutout width
2-1/4" (57)
GA S COOKTOP CUTO UT AN D C L EAR AN C E DI M ENS I O N S
Template
2-1/8" (54)
24-11/16" (628)
22-5/16" (567)
Downdraft cutout width:
30" (762) is 27-1/16" (687)
36" (914) is 33-1/16" (840)
19-1/8" (486)
1-1/16"
(27)
BT
MIN.
1/2"
(13)
Cooktop cutout width
1-7/8" (48)
Page 4 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N
AVAILABLE REMOTE B L O WER S
V T R 6 3 0W – 600 CFM
VTR 1 0 30 W – 1 0 0 0 CF M
AVAILABLE IN LIN E BL O WER S
V T I6 1 0W – 600 CFM
V T R1 3 3 0 W – 1 3 0 0 CF M
AVA I L A BL E F L E XI BL E B LO W ER
VTI 1 0 1 0 W – 1 0 0 0 CF M
V T D 6 0 0 P – 6 0 0 CF M
103/8"
(264 mm)
123/4"
(324 mm)
11 5/8"
(295 mm)
11 5/8"
(295 mm)
51/8"
(130 mm)
5"
123/4" (127 mm)
(324 mm)
73/8"
(187 mm)
51/4"
(133 mm)
measurements in inches (mm)
AVAILABLE ROOFPL ATES
R F P LT 600P – FOR US E WI TH
R E MOTE BLOWER VTR 6 3 0 W
R FPLT1 00 0 P – F O R U S E W I T H 1 0 0 0 CF M RE M O T E BL O W E R
VTR 1 0 3 0 W A N D 1 3 0 0 CF M BL O W E R V T R1 3 3 0 W
Page 5 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N C O NT I N U E D
B LOWER DOWN DRA FT TR AN SI TI O N S
C VTSI D E6
6" round transition allows
for left, right, or rear
venting. Use with inline
and remote blowers, and
ducting with 6" round duct
connections.
CV T F RO NT 6
6" front rough-in plate
allows for front venting.
Use with inline and remote
blowers, and ducting with
6" round duct connections.
C VTSI D E8
8" round transition allows for
left, right, or rear venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
CV T F RO NT 8
8" round front plate allows
for front downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
C VTSI D E1 0
10" round transition allows
for left, right, or rear venting.
Use with inline and remote
blowers, and ducting with
10" round duct connections.
CV T F RO NT 10
10" front rough-in plate
allows for front venting.
Use with inline and remote
blowers, and ducting with
10" round duct connections.
C VD UC T2
Rectangular 2 ft. long x 1 7/8
in deep x 19 in wide duct.
CVDUCT2 transition required
to directly connect CVDUCT2
to sides or rear of downdraft
housing. Can be used as an
extension to exhaust through
a cabinet or wall, and can be
cut to modify length. For use
with installation of inline or
remote blower applications
with CVTSIDE6, CVTSIDE8,
and CVTSIDE10.
Page 6 of 13
CV T RE CT2
Transition required to connect CVDUCT2 rectangular
duct to downdraft housing
at left, right, or rear
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
RE MOTE OR IN LIN E B L O WER I N STAL L ATI O N C O NT I N U E D
OP T I O N AL ACCESSO R I ES
RE P L A CE M E N T CH A RCO A L F ILT ER
U CV F I LT E R
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
R EC I R C UL ATI O N KI T
UC VR EC I R C
E XT N CE 5
Includes 1 charcoal filter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
This cable extends 5 ft. to move the electrical panel
out of the way to offer full installation flexibility in
any ducting scenario while installing the downdraft.
Ability to connect two cables together to make a
10 ft. cable.
E XT N CB2 5 W
For use with the following inline, remote and flexible blowers:
VTR630W, VTR1030W, VTR1330W, VTI610W, VTI1010W, VTD600P
D O WN DR AFT G A S
C O O K TO P SE A L T RI M
K I T UC V3 6 ST
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
Page 7 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
F LE XIBLE BLOWER I N STAL L ATI O N – FR O N T EX H A U S T E XA M P L E
103/8"
(264 mm)
RE Q U I RE D BL O W E R
103/8"
(264 mm)
123/4"
(324 mm)
123/4"
(324 mm)
11 5/8"
(295 mm)
51/8"
(130 mm)5
11 5/8"
(295 mm)
V T D 6 0 0P – 600 CF M
600 CFM flexible blower
can be installed as an
11 5/8"
integrated or inline
blower
(295
mm)
11 /8"
(295 mm)
51/8"
(130 mm)
5"
123/4" (127 mm)
(324 mm)
5"
123/4" (127 mm)
(324 mm)
73/8"
(187 mm)
51/4"
(133 mm)
73/8"
(187 mm)
51/4"
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
O P T I O N A L A CCE S S O RI E S
A P P LICATION
RE CI RCULAT IO N KIT
U CV RE C IR C
- Front downward application with space under floor line for ductwork*
- Integral blower with front downward application can be used with
optional recirculation kit*
Includes 1 charcoal filter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
- Integral blower can rotate for left or right exhaust
- Elbow and ductwork are not included
D O W N D R A F T GA S
CO O KT O P S EA L T R IM
KI T U CV36S T
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
RE P L A CE M E N T CH A RCO A L F ILT ER
U CV F I LT E R
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
E XT N CE 5
This cable extends 5 ft. to move the electrical panel
out of the way to offer full installation flexibility in
any ducting scenario while installing the downdraft.
Ability to connect two cables together to make a
10 ft. cable.
*For only front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical
panel to downdraft. Refer to installation manual.
Page 8 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
(4) BOLTS
elected,F LEBLOWER
XIBLE BLOWER I N STAL L ATI O N – FR O N T EX H A U S T W I T H F L E XI BL E BL O W E R BE L O W F L O O R L I N E E XA MPLE
SUPPORT LEGS
103/8"
RE Q U I RE(264
D BL
OWER
mm)
123/4"
103/8"
(324 mm) (264 mm)
123/4"
(324 mm)
11 5/8"
(295 mm)
600 CFM flexible blower
can be installed as an
11 5/8" integrated or inline blower
(295 mm)
51/8"
(130 mm)
on g
11 5/8"
(295 mm)
51/8"
(130 mm)
5"
123/4" (127 mm)
(324 mm) 5"
123/4" (127 mm)
(324 mm)
on -
V T D 6 0 0 P – 600 CF M
11 5/8"
(295 mm)
73/8"
(187 mm)
51/4" 73/8"
(187 mm)
(133
mm)
1
5 /4"
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
RE Q U I RE D A CCE S S O RI E S
5.
this time.
B - Installation using inline or remote
blowers - with ducting through front
panel opening
CV T F RO NT 8
8" round front plate allows
for front downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
A P P LICATION
CAUTION
- Front downward application with space under floor line for ductwork*
- Elbow
and for
ductwork
not be
included
alone
support.are
It may
necessary to add extra support for
6", 8", OR 10” (152MM, 203MM,
OR 254MM) ROUND
REMOTE ROUGH-IN
PLATE (Purchase Separately)
O P T I O N A L A CCE S S O RI E S
FRONT
PANEL
D O W N D R A F T GA S
CO O KT O P S EA L T R IM
KI T U CV36S T
If blower
discharge is
down,
electrical
panel must be
relocated.
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.
E XT N CE 5
This cable extends 5 ft. to move the electrical panel
out of the way to offer full installation flexibility in
any ducting scenario while installing the downdraft.
Ability to connect two cables together to make a
10 ft. cable.
1. Remove hex nuts to remove front panel cover.
2. If blower discharge is down, remove (4) #8-32 hex nuts and
3. Place 6”, 8”, or 10” (152mm, 203mm, or 254mm) round rough-in
plate (purchase separately) over studs around front panel opening.
4. Tighten hex nuts to secure remote discharge plate in place.
*For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel
to downdraft. Refer to installation manual.
Page 15
Page 9 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
F LE XIBLE BLOWER I N STAL L ATI O N – L EFT O R R I GH T S I D E E XH A U S T E XA M P L E
A P P L I CAT I O N
- Left or right side exhaust options to preserve precious kitchen storage space or if
ducting is more convenient for these configurations*
- Requires at least 18" of clearance to fit the blower and transition
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
RE Q U I RE D BL O W E R
1033/8"
10 mm)
/8"
(264
(264 mm)
1233/4"
12 mm)
/4"
(324
(324 mm)
RE Q U I RE D A CCE S S O RY
11 55/8"
11 mm)
/8"
(295
(295 mm)
Left Side Exhaust
11 55/8"
11 mm)
/8"
(295
(295 mm)
511/8"
5 mm)
/8"
(130
(130 mm)
5"
mm)
1233/4" (1275"
(127
mm)
12 mm)
/4"
(324
(324 mm)
733/8"
7 mm)
/8"
(187
511/4" (187 mm)
5
/
4
"
(133 mm)
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
V T D 6 0 0 P – 6 0 0 CF M
600 CFM flexible blower can
be installed as an integrated
or inline blower
Right Side Exhaust
CV T S I D E 8
8" round transition allows for left or right
venting. Use with VTD600P blower as an
inline installation, and ducting with 8" round
duct connections.
OP T I O N AL ACCESSO R I ES
R EC I R C UL ATI O N KI T
UC VR EC I R C
Includes 1 charcoal filter and 1 metal grill
vent plate (blower sold separately). Use
with induction/electric cooktops only.
EXTNC E5
This cable extends 5 ft. to move the electrical panel out of the way to
offer full installation flexibility in any ducting scenario while installing
the downdraft. Ability to connect two cables together to make a
10 ft. cable.
RE P L A CE M E N T CH A RCO A L F I LT ER
U CV F I LT E R
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
D O W N D RA F T G A S CO O KT O P SEA L
T RI M KI T U CV 3 6 S T
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas cooktops.
*For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired.
Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual.
NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and/or ductwork. Refer to installation manual.
Page 10 of 13
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
F LE XIBLE BLOWER I N STAL L ATI O N – R EAR O R DO W N WA RD E XH A U S T E XA M P L E
A P P L I CAT I O N
- Rear or downward exhaust options to preserve precious kitchen storage space or if
ducting is more convenient for these configurations*
- Requires at least 18" of clearance to fit the blower and transition
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
RE Q U I RE D BL O W E R
1033/8"
10 mm)
/8"
(264
(264 mm)
1233/4"
12 mm)
/4"
(324
(324 mm)
11 55/8"
11 mm)
/8"
(295
(295 mm)
11 55/8"
11 mm)
/8"
(295
(295 mm)
511/8"
5 mm)
/8"
(130
(130 mm)
Rear Exhaust
RE Q U I RE D A CCE S S O RY
5"
mm)
1233/4" (1275"
(127
mm)
12 mm)
/4"
(324
(324 mm)
733/8"
7 mm)
/8"
(187
511/4" (187 mm)
5
/
4
"
(133 mm)
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
V T D 6 0 0 P – 6 0 0 CF M
600 CFM flexible blower can
be installed as an integrated
or inline blower
CV T S I D E 8
8" round transition allows for rear or
downward venting. Use with VTD600P
blower as an inline installation, and ducting
with 8" round duct connections.
*For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel
can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5
accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual.
NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to
fit the blower and/or ductwork. Refer to installation manual.
Downward Exhaust
OP T I O N AL ACCESSO R I ES
R EC I R C UL ATI O N KI T
UC VR EC I R C
Includes 1 charcoal filter and 1 metal grill
vent plate (blower sold separately). Use
with induction/electric cooktops only.
EXTNC E5
This cable extends 5 ft. to move the electrical panel out of the way to
offer full installation flexibility in any ducting scenario while installing
the downdraft. Ability to connect two cables together to make a
10 ft. cable.
Page 11 of 13
RE P L A CE M E N T CH A RCO A L F I LT ER
U CV F I LT E R
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
D O W N D RA F T G A S CO O KT O P SEA L
T RI M KI T U CV 3 6 S T
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas cooktops.
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
F LE XIBLE BLOWER I N STAL L ATI O N – SI DE EX H AU S T W I T H S L I M 2 ' RE CTA N G U L A R D U CT E XA M P L E
A P P L I CAT I O N
- Side exhaust option to preserve precious kitchen storage space
or if ducting is more convenient for this configuration*
- A slim 2' rectangular duct is available to place flexible blower in
areas such as unused corner in island or peninsula applications
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
103/8"
(264 mm)
RE Q U I RE D BL O W E R
123/4"
(324 mm)
103/8"
(264 mm)
11 5/8"
(295 mm)
123/4"
(324 mm)
51/8"
(130 mm)
51/8"
(130 mm)
RE QUIRED ACCESSO R I ES
5"
123/4" (127 mm)
(324 mm)
C VTSI D E8
8" round transition to connect
CVDUCT2 to VTD600P. Use with
VTD600P blower as an inline installation, and ducting with 8" round
duct connections.
11 5/8"
(295 mm)
5"
123/4" (127 mm)
(324 mm)
11 5/8"
(295 mm)
V TD600P –
6 00 CF M
600 CFM flexible
11 5/8"
blower can
be mm)
(295
installed as an
integrated or
inline blower3
7 /8"
(187 mm)
51/4"
(133 mm)
73/8"
(187 mm)
51/4"
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
O P T I O N A L A CCE S S O RI E S
RECIR CU LAT IO N
KI T U CVR ECIR C
C VDUC T2
Rectangular 2 ft. long x 1 7/8 in
deep x 19 in wide duct. CVDUCT2
transition required to directly
connect CVDUCT2 to sides or rear
of downdraft housing. Can be
used as an extension to exhaust
through a cabinet or wall, and can
be cut to modify length. For use
with installation of inline or remote
blower applications with CVTSIDE6,
CVTSIDE8, and CVTSIDE10.
Includes 1 charcoal
filter and 1 metal
grill vent plate
(blower sold
separately). Use with
induction/electric
cooktops only
RE P L A CE M E N T CH A RCOA L F ILT ER
U CV F I LT E R
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
D O W N D RA F T G A S CO O KT O P S EA L
T RI M KI T U CV 3 6 S T
C VTR EC T2
Transition required to connect
CVDUCT2 rectangular duct
to downdraft housing at left,
right, or rear
*For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel
can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5
accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual.
NOTE: Some applications may require deeper cabinets. Refer to installation manual.
Page 12 of 13
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas
cooktops.
E XT N CE 5
This cable extends 5 ft. to move the electrical
panel out of the way to offer full installation
flexibility in any ducting scenario while
installing the downdraft. Ability to connect
two cables together to make a 10 ft. cable.
9 / 19
UCVM36XS
3 6 - I N C H D O W N D R A F T V E N T I L AT I O N
MA S T ERPIECE ® SERIES
F LE XIBLE BLOWER I N STAL L ATI O N – R EC I R C UL AT I O N E XA M P L E
RE Q U I RE D BL O W E R
103/8"
(264 mm)
123/4"
(324 mm)
51/8"
(130 mm)
5"
123/4" (127 mm)
(324 mm)
103/8"
(264 mm)
123/4"
(324 mm)
11 5/8"
(295 mm)
11 5/8"
V T D 6 0 0(295
P –mm)
600 CF M
600 CFM flexible blower
can be installed as an
5/8"
integrated or11inline
blower
(295 mm)
51/8"
(130 mm) 11 5/8"
(295 mm)
5"
73/8"
123/4" (127 mm)
(187 mm)
(324 mm)
51/4"
(133 mm)
73/8"
(187 mm)
51/4"
(133 mm)
measurements in inches (mm)
measurements in inches (mm)
RE Q U I RE D A CCE S S O RI E S
A P P LICATION
RE CI RCULAT IO N KIT
U CV RE C IR C
-A
llows for non-ducted downdraft installation by eliminating the need
to exhaust to the exterior of the home*
Includes 1 charcoal filter
and 1 metal grill vent plate
(blower sold separately).
Use with induction/electric
cooktops only
-R
ecirculation module and metal grill vent plate placement can be
rotated for flexible exhaust placement
- Elbow and ductwork are not included
- Use with induction/electric cooktops only
EXHAUST
THROUGH
CABINET
SIDE
N B O X 14 1/2”
EXHAUST
THROUGH
CABINET
SIDE
O P T I O N A L A CCE S S O RI E S
RE P L A CE M E N T CH A RCO A L FILT ER
U CV F I LT E R
14 1/2”
(368)
(368)
of exhaust.
recirculation box inlet will align.
Includes 1 replacement charcoal filter for
UCVRECIRC recirculation kit
opening in cabinet base.
ing.
nsert exhaust end down into opening. 15” 3 1/2" (89) x 14 1/4" (362)
t.
(380)
toe space, rear, or side of cabinet.
EXHAUST OPENING
15”
DECORATIVE
3 1/2" (89) x 14 1/4" (362)
(380)
GRILLEEXHAUST OPENING
.
EXHAUST
THROUGH
CABINET
BACK
ecorative grille.
n cabinet base.
ot
83) x 14” (356) duct extension (not
n box outlet toMeasurements
decorative grille
in inches (mm).
and tape to make them secure and
minum
Measurements
in inches (mm).14 1/2"
D O W N D RA F T G A S CO O KT O P S EA L T R IM
KI T U CV 3 6 S T
DECORATIVE
GRILLE
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas cooktops.
EXHAUST
THROUGH
CABINET
BACK
E XT N CE 5
This cable extends 5 ft. to move the electrical panel
out of the way to offer full installation flexibility in
any ducting scenario while installing the downdraft.
Ability to connect two cables together to make a
10 ft. cable.
14 1/2"
(368)
(368)
e.
e recirculation box to cabinet base.
15"
(380)
blower
exhaust to recirculation box
x
3 1/2" (89) x 14 1/4" (362)
DECORATIVE
inum tape to make
them secure and EXHAUST OPENING
DECORATIVE
and
GRILLE
GRILLE
of
s recirculation box and attach legs
5” screws.
15"
(380)
3 1/2" (89) x 14 1/4" (362)
EXHAUST OPENING
*For front downward ducting applications, electrical panel must be remotely mounted.
Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed
electrical panel to downdraft. Refer to installation manual.
DIMENSIONS
DIMENSIONS
16”
16”
16”
(406)
17 rights
1/2”
These warranties(406)
give you specific legal
other
that vary from state to state. Full warranty and limited warranty from date of installation. For complete warranty
16” rights
17 1/2”and you may have
(406)
(445)
(406)
8” your dealer.
details, refer to your
ask
8” Use & Care manual, or(445)
(203)
(203)
4 1/2”
OPTIONAL
REMOTE BLOWER
4 1/2” MOUNT
UNT
(114)
(114)
Specifications
are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation
ower mounted to
3 1/4”
3 1/4” For the most detailed information,
engineer for your specific ventilation requirements.
refer to installation instructions accompanying product or write to Thermador indicating the model
(83)
aming in remote
(83)
location - usingnumber. Specifications are correct at time6 1/2”
of printing. Thermador reserves the right
to change product specifications or design without notice. Some models are certified for use in Canada.
3 3/4”
6 1/2”
3
3/4”
(165)
(95)
ounting brackets.
Thermador is (165)
not responsible for products that are transported
from
14”the U.S. for use in Canada.
(95)
14”
(356)
12 1/4”
Blower outlet and
(356)
Measurements
12 1/4”
BLOWER
(311)
recirculation box1 800 Measurements
735 4328 | USA(311)
THERMADOR.COM
| CANADA
THERMADOR.CA | 15”
©2019 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED.
in inches (mm).
15”
(380)
in inches (mm).
inlet must align.
(380)
16”
(See below.)
16”
(406)
ETAL 8” ROUND DUCT
(per local codes)
(406)
Page 13 of 13