Sick OL1 Operating instructions
SICK OL1 is an optical micrometer that, when used with evaluation unit AOD1, provides precise distance measurements within a 10mm range. It consists of two sensor heads, a sender and a receiver, that can be aligned using the built-in alignment LEDs to ensure accurate measurements. The device is ideal for various applications, including edge detection, width measurement, and gap measurement. The OL1 offers adjustable sensitivity settings, allowing it to adapt to different materials and measurement scenarios.
PDF
Download
Document
Advertisement
Advertisement
8022330/0000/2018-05-09 5. 6. SICK AG Erwin-Sick-Straße 1 D-79183 Waldkirch ✓ ✓ 7. www.sick.com OL1 OPERATING INSTRUCTIONS 1 Complete with A . ON is bracketed. The alignment LEDs are flashing. Align sensor heads so that both LEDs light up, but do not flash. ° If no LED lights up on the receiver: Align sensor heads to one another. ° When the red LED flashes: Move receiver upwards until both LEDs light up. ° When the green LED flashes: Move receiver downwards until both LEDs light up. Intended use CAUTION Optical radiation: Laser class 1 The accessible radiation does not pose a danger when viewed directly for up to 100 seconds. It may pose a danger to the eyes and skin in the event of incorrect use. • Do not open the housing. Opening the housing may increase the level of risk. • Current national regulations regarding laser protection must be observed. About this document OL1 sender OL1 receiver Upper Lower 1 2 3 4 8. 9. confirm with A . Hold B to return to the basic screen. 4 Electrical installation 1. Connect OL1 sensor heads without voltage to the AOD1 with the supplied Ycable. 2 2.1 Supplementary and other relevant documents • AOD1 Quickstart (no. 8019684) • AOD1 operating instructions (no. 8020327) You can download the documents in the Internet at www.sick.com. To do this, enter the part number of the publication. Additional information (e.g. application examples, other documents, associated software) can be found at www.sick.com/OL1 1 Commissioning , select Off and After alignment: End Direction Checking: Click on The operating instructions are used to put the product into operation quickly and easily to get the first measurement results. 3 to select ON. en The optical OL1 micrometer must be used in conjunction with evaluation unit AOD1. Up to two sets of OL1 measurement sensors can be configured and controlled with the evaluation unit. 2 Press 3 4 OL1 sender (connected with gray cable) 1 OL1 receiver (connected with black cable) 2 Y-cable 3 AOD1 (not included with delivery) 4 2. Connect AOD1 to the voltage supply (see AOD1 Quickstart). 2 4 Ensure that installation is done by a qualified person. 3.1 • • • • 3.2 1. 2. 3. 4. Scope of delivery OL1 in the version ordered Y-cable for connecting the OL1 sender and OL1 receiver Printed operating instructions (this document) Distance sensor safety notes (no. 8019331) 1 Y-cable connection diagram to AOD1, M8, 4-pin Mounting Ensure that the device is not connected to a voltage supply. Mount the AOD1 on the mounting rail. Mount the OL1 over the fixing holes. Align sensor heads in relation to the reference surfaces so that both top sides and both side surfaces lie in the same plane. 2 1 3 3 3 3 3 3 Pin Description Color 1 Vcc Brown 2 B (RS-485) White 3 0V Blue 4 A (RS-485) Black 5 Device description Dimensions Dimensions: A LED display OL1E (receiver) 1 1 2 3 2 Sender Receiver Reference surface 3.3 Alignment of sender - receiver (“direction checking”) The receiver has two alignment LEDs to correctly assembly and align the sensor heads. To use the alignment LEDs, the Direction Checking function in the AOD1 menu must be activated. 1. Keep pressing until an arrow appears in front of Head 1 or 2 (depending on where the OL1 is connected). 2. Press A to get to the Top Menu. 3. Press to select Setup mode. 4. Press to display Direction Checking. 8022330/0000/2018-05-09/en Name Color Description Power Green • • Lights up: Supply voltage on Flashing: Device is in Direction check‐ ing mode (Direction checking) Alarm Red • • Lights up: Device displaying an alarm Flashing: Device is in Direction check‐ ing mode (Direction checking) AOD1 display and OL1 NOTE See AOD1 Quickstart (no. 8019684) for an exact description of the operating elements and menu structure of the AOD1. OL1 | SICK 1 AOD1 display Schematic image Description 9.999 background changes to white There is no object in the measuring range. 9.999 background remains black The object is larger than the measuring range. -xxx The object protrudes into the measuring range from above. Measure polarity Set in a negative direction +xxx +xxx The object protrudes from below into the measuring range. 1. 2. 6.2 OL1 “Teach mode” teach-in menu Teach-in option Measure polarity Set in a positive direction Number Function Comment 1 Zeroing – 2 Reset Zeroing – 3 Translucent Teach Adapts the sensitivity value. Translucent Teach is recommended for semi-transparent materials to improve the detection results It is only possible to use the Translucent Teach if the sensitivity is set to Adjusted in the Setup modesee OL1 “Setup mode” configuration menu, page 2. The Transluent Teach is run without an object in the measuring range. Measure polarity Set in a negative direction -xxx 6 Measure polarity Set in a positive direction OL1 sender 1 OL1 receiver 2 Upper 3 Lower 4 How the measured values are displayed from the top or bottom (cable side) is set here. Positive: Top -5.000 mm, bottom +5.000 mm Negative: Top +5.000 mm, bottom -5.000 mm OL1 menu Keep pressing until an arrow appears in front of Head 1 or 2 (depending on where the OL1 is connected). Press A to get to the Top menu. 7 1. Top menu Num‐ ber Function Parameter Comment 1 Top Menu Teach mode – Setup mode – Back Return to basic screen 2. 3. 4. 5. 6.1 OL1 “Setup mode” configuration menu 1. Starting from the Top Menu , press to get to the configuration menu. 6. Adjustment options 8. Num‐ ber Function Parameter Comment 1 Sensitivity Mini Sense – 2nd Sense – 3rd Sense – 4th Sense – Max Sense – Adjusted Is set via Translucent Teach see OL1 “Teach mode” teachin menu, page 2 Positive Negative see “Measure polar‐ ity” direction func‐ tion, page 2 2 Measure polarity 3 Moving averaging 1 to 128 – 4 Zeroing value -5.000 Up to 9.999 (0.000) – 5 Measure Type Edge – Width – Top Object comes into light band from above Bottom Object comes into light band from below OFF ON see Alignment of sender - receiver (“direction check‐ ing”), page 1 Not Reset – Execute by A – 6 7 8 Measure direction Direction Checking Reset Settings “Measure polarity” direction function Direction function only works with edge measurement (Edge). 8022330/0000/2018-05-09/en 7. Application examples Keep pressing until an arrow appears in front of Head 1 or 2 (depending on where the OL1 is assembled). Press A to get to the Top Menu. Press to select Setup mode. Press Press until Measure Type is displayed. or to select Edge or Width. Press A to confirm. Hold B to return to the basic screen. Press B to leave the AOD1, Head 1, Head 2 selection mode in the basic screen. “Edge” detection application • Measure the edge position relating to the measuring range center of the light band with leading edge detection see AOD1 display and OL1, page 1. • When more than one edge is in the measuring range, the device cannot measure and show the value 9.999 (background remains black). “Edge” detection application for transparent objects NOTE Safe edge detection is not guaranteed for very transparent objects (in the range from about 80% transmission). • • • The function works the same as for edge detection of non-transparent objects. The “Adjusted” value must be set in the “Sensitivity” setting for edge detec‐ tion of transparent objects. For optimal sensitivity adjustment, there must be no measuring object between the sender and the receiver see OL1 “Setup mode” configuration menu, page 2. The direction from which the object protrudes into the measuring range must be specified in the "Measure polarity" menu item see “Measure polarity” direction function, page 2. “Width” and diameter measurement application • Measures the distance between two edges. • In this measurement type, the device shows the measured value of 0.000 mm to 9.999 mm. • The device distinguishes between light-dark and dark-light edges. Then the width function can measure both the width and the gap. • In “Width” mode, there must always be exactly two edges inside the measur‐ ing range. If there are more than two edges inside the measuring range, the output measured values are not specified. OL1 | SICK 2 If there is no or only one edge in the measuring range, the device shows an alarm or “cannot be measured”. The direction function (Measure polarity) does not work for width mea‐ surement. • • Typ. light spot size 3 mm x 14 mm Linearity ±40 µm Repeatability 10 µm Measuring frequency 2 ≤ 2 kHz Mounting M3 screws Connection type Cable with M8 male connector, 4pin, 30 cm Status LEDs Sender Voltage supply: Green Receiver Voltage supply: Green Alarm: Red Supply voltage DC 12 V ... DC 24 V Power Consumption < 20 mA (12 V) Protection Reverse polarity protected Enclosure rating IP50 Ambient temperature, operation –10 °C ... +50 °C Ambient temperature, storage –20 °C ... +60 °C Figure 2: Measurement of object width Min rel. air humidity (noncondensing) 35% 8 Max rel. air humidity (non- 85% condensing) Figure 1: Measurement of the gap between two objects edges Voltage supply Ambient data Cleaning NOTICE Equipment damage due to improper cleaning. Improper cleaning may result in equipment damage. • Only use recommended cleaning agents. • Never use sharp objects for cleaning. 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis, 2 hours each) Shock resistance 500 m/s2 (x-, y-, z-axis, 3 times each) Housing material Clean the front screens at regular intervals and in the event of contamina‐ tion with a lint-free lens cloth (part no. 4003353) and plastic cleaning agent (part no. 5600006). The cleaning interval essentially depends on the ambi‐ ent conditions. 9 Vibration resistance Weight 1 Technical data Distance between sender and receiver Max. 300 mm Measuring range 10 mm Light sender 1 Laser, red Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 2 Aluminum Sender 30 g Receiver 30 g Wavelength: 660 nm Max. pulse output: 0.39 W Max. average power: 0.16 mW Max. pulse length: 0.5 ms The AOD1 does not communicate in sync with the measuring frequency. The AOD1 reac‐ tion after scanning the sensor head is delayed by a maximum 1.5 ms. A 9.6 21 (0.38) (0.83) (0.13) 4 3.3 (0.13) 14.4 36.5 4 5.5 61 2x Ø 3.2 (2.40) 42 3 (1.65) 25.2 (0.99) 23.5 (0.93) 19 (0.75) 1 11.8 (0.46) 2 (1.44) (0.24) (0.22) 6 5 (0.57) 1 2 3 4 5 Window Sender Receiver LED Connecting cable 8022330/0000/2018-05-09/en OL1 | SICK 3 8022330/0000/2018-05-09/en OL1 | SICK 4 ">

Public link updated
The public link to your chat has been updated.
Advertisement