Sick AOD1 Evaluation unit for OD Mini Pro (RS485) Quickstart
SICK AOD1 Evaluation unit for OD Mini Pro (RS485) is an evaluation unit that can be used with up to two displacement measurement sensors of the type OD Mini Pro (RS485), OD5000, and OL1. The SICK AOD1 Evaluation unit is used in combination with two sensor heads in order to carry out measurements of height differences or thickness. It can be used in various applications, such as:
- Level measurement
- Thickness measurement
- Position measurement
- Object detection The SICK AOD1 Evaluation unit has a variety of features that make it a versatile and powerful tool for displacement measurement. These features include:
PDF
Download
Document
Advertisement
Advertisement
8019684/120Q/2018-11-05 Master Slave SICK AG Erwin-Sick-Straße 1 D-79183 Waldkirch www.sick.com AOD1 1 QUICKSTART 1 Intended use AOD1 is an evaluation unit that can be used with up to two displacement mea‐ surement sensors of the type OD Mini Pro (RS485), OD5000, and OL1. The set‐ tings of the displacement measurement sensor are adjusted via the evaluation unit. The evaluation unit is used in combination with two sensor heads in order to carry out measurements of height differences or thickness. By mounting an additional AOD1 (slave), up to four sensor heads can be offset against each other 2 About this document The purpose of the Quickstart is to allow you to commission the product quickly and easily and to achieve initial measurement results. The operating instructions must have been read and understood prior to the commencement of any work. 2.1 Supplementary and other relevant documents • OD Mini Pro operating instructions (German/English: no. 8017923) • OD5000 operating instructions (German no. 8021390, English no. 8021391) • OL1 operating instructions (German no. 8022329, English no. 022330) • WI180C-PB PROFIBUS coupler quickstart (German/English: no. 8017973) • WI180C-PB PROFIBUS coupler operating instructions (German no. 8017974, English no. 8018416) You can download the documents in the Internet at www.sick.com. To do this, enter the part number of the publication. Additional information (e.g. application examples, other documents, associated software) can be found at www.sick.com/OD_Mini in the accessories section. 3 Commissioning Ensure that installation is done by a qualified person. 3.1 Scope of delivery • AOD1 in the version ordered. • Protective cap included or possibly attached to the device. Without connect‐ ing cables and brackets. • Printed Quickstart (this document): English (no. 8019684), German (no. 8019683), French (no. 8019685) 3.2 Mounting 1. Ensure that the device is not connected to a voltage supply. 2. Clamp the device onto a mounting rail. 2 1 Figure 1: Mounting rail mounting 3. Check whether the mounting hook is correctly clicked into place and the device is securely mounted. 3.3 Master/slave connection (optional) 1. Clamp the downstream devices (e.g. another AOD1 or a WI180C-PB) onto the mounting rail as shown in their mounting instructions. 2. Push the downstream devices onto the 5-pin connection (1) of the AOD1. While doing so, ensure the order is correct (refer to the operating instruc‐ tions for the respective device). 8019684/120Q/2018-11-05/en 1 en Figure 2: Master/slave connection 3. 4. Check whether the devices are correctly contacted. Fix the connected devices on the mounting rail without any spaces. 4 Electrical installation 1. Contact the cable ends as shown in the following graphic. brn 1 blu 2 blk 3 yel 4 pur 5 gra 6 pnk 7 shield 8 wht 9 L+ 0V Q1 Q2 Q3 IN1 IN2 Analog ground QA Figure 3: AOD1-xxx7Dx: connection diagram 12-24 V DC supply voltage (brown) 1 Supply voltage 0 V (blue) 2 Output Q1 (black) 3 Output Q2 (yellow) 4 Output Q3 (violet) 5 Input IN1 (gray) 6 Input IN2 (pink) 7 Analog ground (shield) 8 Analog output QA (white) 9 brn 1 blu 2 blk 3 yel 4 pur 5 shield 6 wht 7 shield 8 pnk 9 L+ 0V Q1 Q2 IN Analog ground QA1 Analog ground QA2 Figure 4: AOD1-xxx7Dx: connection diagram 12-24 V DC supply cable (brown) 1 Supply voltage 0 V (blue) 2 Output Q1 (black) 3 Output Q2 (yellow) 4 Input IN (violet) 5 Analog ground QA1 6 Analog output QA1 (white) 7 Analog ground QA2 8 Analog output QA2 (pink) 9 2. Connect the device to the voltage supply. ✓ The display lights up. ✓ When switching on for the first time, the function for setting the dialog lan‐ guage is opened. 3. To select the language, press the pushbuttons or and confirm your selection by pressing the A pushbutton. ✓ The device display changes to the main view. The dialog language can also be changed at a later date via the configuration menu. AOD1 | SICK 1 5 Device description Dimensions Overview 2 1 3 1 PWR Head 2 32.44 OUT1 A 42.41 AOD1 Select 10 OUT3 78 34 Head 1 OUT2 33,2 1 B 9,6 Figure 5: Display and operating elements Status LEDs 1 Device display 2 Operating elements 3 6 Status indicators LED Display Status PWR O (green) Normal operation Ö (green) Energy-saving mode Ö (red) Error O (orange) Interface switched on O= illuminated; Ö = flashing Operating help Operating help symbols are displayed on the device display. Operating help Symbol , Meaning , , Displays the actions that can be executed by pressing the pushbut‐ tons , , , . Displays the actions that can be executed by pressing the pushbutton A . Displays the actions that can be executed by pressing and holding the pushbutton A . Displays the actions that can be executed by pressing the pushbutton B. Displays that the selected entry has not been confirmed. Displays that the selected entry has been confirmed. Displays which function/setting is selected. Displays that the value can be changed. Operating elements Operating elements Pushbutton Function A Confirm settings. B Return to previous view. , , , Select settings, change view, increase/lower values. Fault indication (summary) Detecting errors Display Cause 9999 (instead of measured value) Compatible sensor connected, but measurement not possible. Possi‐ ble cause: The measuring value is outside of the measuring range. 99999 (instead of calculated value) Calculation not possible because at least one sensor is not returning a measured value. ––––– (instead of measured value/ calculated value) No compatible sensor connected. 8019684/120Q/2018-11-05/en 18,8 36,6 Figure 6: Dimensional drawing (dimensions in mm) Interface (sensor side), 2x M8 female connectors, 4-pin 1 Status LEDs OUT1, OUT2, OUT3 9,6 Operation Switching display on/off After 10 minutes of no pushbutton being pressed, the display is switched off, the PWR LED flashes green. 1. Press any pushbutton to switch the display on again. Locking pushbutton 1. Press and hold the pushbutton B for at least 2 seconds to lock the pushbut‐ tons. ✓ --- Key Locked --- is shown on the bottom edge of the display. 2. Press and hold the pushbutton B for at least 2 seconds again to unlock the pushbuttons. Changing the display view 1. To switch between the main view and the calculation view, press the push‐ button or . Opening the configuration menu 1. In the main view, press the pushbuttons or . ✓ lights up at the left edge of the display and shows the currently selected device (Head1, Head2 or AOD1). 2. To select the device, press the pushbuttons or and confirm your selec‐ tion by pressing the A pushbutton. ✓ The top menu view of the selected device opens. 7 Configuring evaluation unit Changing the language 1. Open the top menu view of the AOD1, see Opening the configuration menu, page 2. 2. To open the ExpertSettings menu, press the pushbutton . 3. To show the Language (言語選択) function, press the pushbuttons or . The following languages can be selected: ° English (英語表示) ° Japanese (日本語表示) 4. To select the language, press the pushbuttons or and confirm your selection by pressing the A pushbutton. Performing a reset 1. Open the top menu view of the AOD1, see Opening the configuration menu, page 2. 2. To open the ExpertSettings menu, press the pushbutton . 3. To show the Reset Settings function, press the pushbuttons or . 4. To select Execute by (perform a reset) press the pushbuttons or and confirm the selection by pressing the pushbutton A : ✓ Finished (reset performed) is displayed instead of Execute by . Selecting the application The application functions selectable in AOD1 can only be used in connection with OD1 or OD500. 1. Open the top menu view of the AOD1, see Opening the configuration menu, page 2. 2. To open the Application Settings menu, press the pushbutton . The following applications can be selected: ° Not use: No preconfigured application, processing operations must be set manually. ° Independent: The two sensors measure independently of one another, no calculation of the measured values takes place. ° Thickness: Thickness measurement of the measured values from the two sensors, see Application descriptions, page 4. AOD1 | SICK 2 Parameter Description Analog Source The assignment of the analog output must be set in the menu I/O Settings. Setting the output value: • Not Use: No output • Active: Output of the measuring object thickness Head 1 ° 5. Head 2 6. Difference: Difference measurement of the measured values from the two sensors, see Application descriptions, page 4. Head 1 Head 2 Parameter Description Difference Teach Use assistant to determine the difference target value between the two measured values. Difference Value Enter difference target value (min. -100.0, max. 100.00). Upper Limit Enter the upper limit of the permissible deviation from the difference target value (min. -327.68, max. 327.67 - Differ‐ ence Value). Lower Limit Enter the lower limit of the permissible deviation from the difference target value (min. -327.68, max. 327.67 - Thick‐ ness Value). Analog Source The assignment of the analog output must be set in the menu I/O Settings. Setting the output value: • Not Use: No output • Active: Output of the measuring object thickness or and confirm your To select the parameters, press the pushbuttons selection by pressing the A pushbutton. Make the parameter settings and confirm the entry by pressing the pushbut‐ ton A . NOTE The assignment of the digital outputs is automatically changed to: • OUT1 : Go Head1 Result • OUT2 : Go Head2 Result This assignment can be changed in the I/O Settings menu. Figure 7: Application thickness ° Difference: Differential value calculation 8 Technical data (excerpt) NFPA79 applications only. Adapters providing field wiring leads are available. as marked on device Refer to the product information. Technical data Figure 8: Application difference 3. 4. To select the pushbuttons, press or and confirm your selection by pressing the A pushbutton. To show the parameter selection, press the pushbutton . The following parameters can be selected for the individual applications: ° Not use: (no adjustable parameters) ° Independent: No calculation ° Parameter Description Analog Source The assignment of the analog output must be set in the menu I/O Settings. Setting the output value: • Not Use: No output • Head1: Output of the measured value from sensor 1 • Head1: Output of the measured value from sensor 2 Thickness: Thickness calculation Parameter Description Thickness Value Enter the target thickness value of the measuring object (min. 0, max. 100.00). Upper Limit Enter the upper limit of the permissible deviation from the thickness target value (min. -327.68, max. [327.67 - Thick‐ ness Value]). Lower Limit Enter the lower limit of the permissible deviation from the thickness target value (min. -327.68, max. 327.67 - Thick‐ ness Value). Characteristic Values Mounting method DIN mounting rail Measuring device interfaces 2x M8, 4-pin Display 128x 96 pixels Status LEDs Voltage supply: red/green Analog outputs: orange Analog outputs AOD1-xxx7Cx: 1x4-20 mA AOD1-xxx7Dx: 2x4-20 mA / 0-10 V switchable Digital inputs 1 Digital outputs 2; NPN/PNP open collector 24 V DC, ≤ 100 mA (residual voltage ≤ 1.8 V) Voltage supply Master: 12-24 V DC including 10% residual ripple Slave: supply via Master Power consumption ≤ 100 mA (at 12 V) Circuit protection Reverse polarity protection Enclosure rating IEC Standard, IP50 Ambient temperature Operation: -20 …+50 °C (no ice formation) Storage: -20 … +60 °C (no ice formation) Ambient humidity Operation: 35 … 85% RH (no condensation) Operation: 35 … 85% RH (no condensation) Vibration resistance 10 … 55 Hz, amplitude 1.5 mm, 2 h across all axes (x, y, z) Shock resistance 500 m/s, 3x across all axes (x, y, z) Housing Polycarbonate Teaching Distance Use the assistant for determining the distance between the measuring devices. Head Distance 8019684/120Q/2018-11-05/en Manually enter the distance between the measuring devices. AOD1 | SICK 3 9 Application descriptions Differential calculation (OD1, OD5000) Thickness calculation (OD1, OD5000) Head 1 Head 2 1 2 Head 1 4 6 6 3 7 5 2 Head 2 Figure 9: Application difference Center of measuring range Head1 1 Center of measuring range Head2 2 Thickness of reference object 3 Measured value Head1 4 Measured value Head2 5 Distance of heads 6 Reference object 7 A description of how easily the device can be configured for measuring thick‐ nesses appears below. This description is based on example values. Parameter Value Sensor heads used (example) 2x OD1-x35x15 Center of measuring range Head1 1 and Head2 2 35 mm Thickness of reference object 7 5 mm Upper and lower limit of differential measurement +0.5 mm / -0.5 mm Assumed distance of heads 6 23.18 mm 1. 2. 3. 4. 5. 6. 7. 8. ✓ 5 4 1 Select Thickness in the AOD1 APP Settings menu. Enter the thickness of the reference object 7 (5 mm). Enter the upper and lower limits of the differential measurement (+0.5 mm and -0.5 mm). Position the reference object in the measuring range of the two sensor heads. Run Teaching - Distance (6 = 3 + 4 + 5) by pressing A (a measured value of 23.18 mm is assumed here). Adjust the Head Distance manually if necessary. Go back to the main screen. to check the calculation. Press the pushbutton The calculated thickness value is displayed: 3 Figure 10: Application description for differential calculation Center of measuring range Head1 1 Center of measuring range Head2 2 Thickness of reference object (differential value) 3 Measured value 1 4 Measured value 2 5 Reference object 6 A description of how easily the device can be configured for measuring differ‐ ences appears below. This description is based on example values. Parameter Value Sensor heads used (example) 2x OD1-x35x15 Center of measuring range Head1 1 and Head2 2 35 mm Thickness of reference object 6 5 mm Upper and lower limit of differential measurement +0.5 mm / -0.5 mm 1. 2. 3. 4. 5. 6. ✓ Select Difference in the AOD1 APP Settings menu. Position the reference object 6 in the measuring range of sensor head Head2. Run Difference - Teach (3 = 4 - 5) by pressing A (a measured value of 5.00 mm is assumed here). Adjust the Difference value manually if necessary. Enter the upper and lower limits of the thickness measurement (+0.5 mm and -0.5 mm). Go back to the main screen. to check the calculation. Press the pushbutton The calculated distance value is displayed: Difference 5.00 + 0.50 5.00 0.50 Threshold Edge and width detection (OL1) Application examples for edge and width detection can be found in the OL1 oper‐ ating instructions publication (German: no. 8022329, English: no. 022330) Thickness 5.00 + 0.50 5.00 0.50 Threshold 8019684/120Q/2018-11-05/en AOD1 | SICK 4 ">

Public link updated
The public link to your chat has been updated.
Advertisement