SICK WTB4C-3_A71 Betjeningsvejledning

Add to my manuals
3 Pages

advertisement

SICK WTB4C-3_A71 Betjeningsvejledning | Manualzz

WTB4C-3_A71

2146637628

9243603 139J

Australia

Phone +61 3 9457 0600

Belgium/Luxembourg

Phone +32 (0)2 466 55 66

Brasil

Phone +55 11 3215-4900

Canada

Phone +1 905 771 14 44

Česká republika

Phone +420 2 57 91 18 50

China

Phone +86 4000 121 000

+852-2153 6300

Danmark

Phone +45 45 82 64 00

Deutschland

Phone +49 211 5301-301

España

Phone +34 93 480 31 00

France

Phone +33 1 64 62 35 00

Great Britain

Phone +44 (0)1727 831121

India

Phone +91–22–4033 8333

Israel

Phone +972-4-6801000

Italia

Phone +39 02 27 43 41

Japan

Phone +81 (0)3 5309 2112

Magyarország

Phone +36 1 371 2680

Nederland

Phone +31 (0)30 229 25 44

SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch

Österreich

Phone +43 (0)22 36 62 28 8-0

Norge

Phone +47 67 81 50 00

Polska

Phone +48 22 837 40 50

România

Phone +40 356 171 120

Russia

Phone +7-495-775-05-30

Schweiz

Phone +41 41 619 29 39

Singapore

Phone +65 6744 3732

Slovenija

Phone +386 (0)1-47 69 990

South Africa

Phone +27 11 472 3733

South Korea

Phone +82 2 786 6321/4

Suomi

Phone +358-9-25 15 800

Sverige

Phone +46 10 110 10 00

Taiwan

Phone +886-2-2375-6288

Türkiye

Phone +90 (216) 528 50 00

United Arab Emirates

Phone +971 (0) 4 8865 878

USA/México

Phone +1(952) 941-6780

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee.

Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Änderungen vorbehalten ∙ Angegebene Produkteigenschaften und

technische Daten stellen keine Garantieerklärung dar.

Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie.

Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia.

Flere repræsentanter og agenturer på www.sick.com ∙ Med forbehold for

ændringer og fejl ∙ De anførte produktegenskaber og tekniske data udgør ikke nogen garantierklæring.

Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia.

Meer vestigingen en vertegenwoordigingen vindt u op www.sick.com ∙

Wijzigingen en correcties voorbehouden ∙ Aangegeven producteigenschap pen en technische gegevens vormen geen garantieverklaring.

Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía.

欲了解更多代表机构和代理商信息,请登录 www.sick.com

如有更改, 不另行通知 ∙ 对所给出的产品特性和技术参数

的正确性不予保证。.

Please note the validity of the additional operating instructions for automation functions

Page 1 of 3

ENGLISH

1. Physical layer

Note: The IO-Link Device's max. current consumption (inclusive load current) shall not exceed the master port's max. output power current.

SIO Modus

Min Cycle Time

Baudrate

2

Process Data Length (IN)

IODD version

Valid for IO-Link version yes

2.3 ms

COM2

2 Byte

V1.19790

1.1.0

2. Process data

Record: 2 Byte

Bitoffset

15

Byte 0 cntval

Type/Subindex Unsigned Integer 14

14 13 12 11 10 9 8

DEUTSCH

1. Physikalische Schicht

Hinweis: Max. Stromaufnahme des IO-Link Devices (inkl. Lastströme) darf max. Ausgangsstrom des Master-Ports nicht

überschreiten.

SIO Modus

Min. Zykluszeit

Baudrate

2

Prozessdatenlänge (IN)

IODD Version

Gültig für IO-Link Version ja

2.3 ms

COM2

2 Byte

V1.19790

1.1.0

2. Prozessdaten

Record: 2 Byte

Bitoffset

15

Byte 0 cntval

Type/Subindex Unsigned Integer 14

14 13 12 11

3

10 9 8

Bitoffset

Byte 1

7

Type/Subindex cntval

Unsigned Integer 14

6 5 4 3

2

2

3

Bit1

Boolean

1

1

2

Bit0

Boolean

0

0

1

Bitoffset

Byte 1

7

Type/Subindex cntval

Unsigned Integer 14

6 5 4 3

2

2

3

Bit1

Boolean

1

1

2

Bit0

Boolean

0

0

1

3. Service data

The following ISDUs will not be saved via Data-Storage: Profile Characteristic, Teach-In Channel, Teach-In State, Setpoint 1, Q1 configuration, Setpoint 2, Q2 configuration, Device / function name, Sender configuration, Counter Version, Debounce Version,

Quality D1, Quality D2 and SLTI Version

IO-Link specific

Index dec (hex)

0 (0x00)

Name

Direct Parameters 1

Format

(Offset)

Length Access

Record 16 Byte rw

1

Default

Value

1 (0x01) Direct Parameters 2

12 (0x0C) Device Access Locks

1 (0x01)

2 (0x02)

Record

Record

16 Byte

2 Byte

Parameter (write)

Access Lock

Bit (0) 1 Bit

Data Storage Lock Bit (1) 1 Bit rw rw rw rw

Value / Range Remark [Unit]

3 (0x03)

4 (0x04)

16 (0x10)

18 (0x12)

19 (0x13)

20 (0x14)

Local Parameterization Lock

Local User Interface

Lock

Vendor Name

Product Name

Product ID

Product Text

Bit (2)

Bit (3)

1 Bit

1 Bit rw rw

String 7 Byte ro

String 18 Byte ro

String 13 Byte ro

String 45 Byte ro

21 (0x15) Serial Number

22 (0x16) Hardware Version

String 8 Byte

String 4 Byte ro ro

23 (0x17) Firmware Version String 19 Byte ro

24 (0x18) Application Specific Tag String 32 Byte rw

36 (0x24) Device Status UInt 8 Bit ro

SICK AG

*******

0 = Device is OK

1 = Maintenance required

2 = Out of specification

3 = Functional check

4 = Failure

5...255 = Reserved

40 (0x28) Process Data Input

SICK device specific

Index dec (hex)

Name

13 (0x0D) Profile Characteristic

14 (0x0E) PDInput Descriptor

15 (0x0F) PDOutput Descriptor

58 (0x3A) Teach-In Channel

59 (0x3B) Teach-In State

1 (0x01) Teach Flags

2 (0x02) Teach State

PD In 2 Byte

Format

(Offset)

Array

Length Access

1

Default

Value

10 Byte ro

Array

Array

UInt

6 Byte

3 Byte

8 Bit ro ro rw 0

Record 1 Byte

Bit (4) 1 Bit ro ro

Bit (0) 4 Bit ro ro

Value / Range

Unsigned Integer16 [5]

Octet String [2]

Octet String [1]

0...2 = Default

BDC false = Teachpoint 1 not taught true = Teachpoint

1 successfully taught

0 = IDLE

1 = SP1 SUCCESS

5 = BUSY

Remark [Unit]

60 (0x3C) Setpoint 1 Record 3 Byte rw

3. Servicedaten

Die folgenden ISDUs werden nicht über Data-Storage gesichert: Profile Characteristic, Teach-in-Kanal, Teach-in-Status, Setpoint

1, Q1-Konfiguration, Setpoint 2, Q2-Konfiguration, Gerätename / -funktion, Einstellung Sender, Counter-Version, Debounce-

Version, Qualität D1, Qualität D2 und SLTI Version

IO-Link spezifisch

Index dez (hex)

0 (0x00)

Name

Direkte Parameter 1

Format

(Offset)

Länge Zugriff

Record 16 Byte rw

1

Standard

Wert

1 (0x01) Direkte Parameter 2 Record 16 Byte rw

12 (0x0C) Gerätezugriffssperren Record 2 Byte rw

1 (0x01) Bit (0) 1 Bit rw

2 (0x02)

Parameter (Schreib-

)Zugriffssperre

Datenspeicherungssperre

Bit (1) 1 Bit rw

3 (0x03)

4 (0x04)

Lokale Parameterisierungssperre

Lokale Benutzerinterface-Sperre

Bit (2) 1 Bit

Bit (3) 1 Bit rw rw

SICK AG 16 (0x10) Herstellername

18 (0x12) Produktname

19 (0x13) Produkt-ID

20 (0x14) Produkttext

21 (0x15) Seriennummer

22 (0x16) Hardwareversion

23 (0x17) Firmwareversion

24 (0x18) Anwendungsspezifische Markierung

36 (0x24) Gerätestatus

String 7 Byte ro

String 18 Byte ro

String 13 Byte ro

String 45 Byte ro

String 8 Byte

String 4 Byte ro ro

String 19 Byte ro

String 32 Byte rw

UInt 8 Bit ro

*******

Wertebereich Bemerkung [Einheit]

0 = Gerät ist OK

1 = Wartung erforderlich

2 = Außerhalb der

Spezifikation

3 = Funktionsprüfung

4 = Fehler

5...255 = Reserviert

40 (0x28) Prozessdaten Eingang PD In 2 Byte ro

SICK spezifisch

Index dez (hex)

Name

13 (0x0D) Profile Characteristic

Format

(Offset)

Array

Länge Zugriff

1

Standard

Wert

10 Byte ro

Wertebereich Bemerkung [Einheit]

14 (0x0E) PDInput Descriptor

15 (0x0F) PDOutput Descriptor

58 (0x3A) Teach-in-Kanal

Array

Array

UInt

6 Byte

3 Byte

8 Bit ro ro rw 0

Unsigned Integer16 [5]

Octet String [2]

Octet String [1]

0...2 = Standard-

BDC

59 (0x3B) Teach-in-Status

1 (0x01) Teach Flags

Record 1 Byte

Bit (4) 1 Bit ro ro

2 (0x02) Teach Status Bit (0) 4 Bit ro false = Teachpunkt 1 nicht gesetzt true = Teachpunkt 1 gesetzt

0 = Bereit

1 = SP1 erfolgreich

5 = In Arbeit

60 (0x3C) Setpoint 1 Record 3 Byte rw

1

2 ro = read only, wo = write only, rw = read/write / ro = nur lesen, wo = nur schreiben, rw = lesen/schreiben

COM values specify the bitrate (see IO-Link specification) / COM Werte spezifizieren die Baudrate (s. IO-Link Spezifikation): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)

3

WTB4C-3_A71

2146637628

9243603 139J

Australia

Phone +61 3 9457 0600

Belgium/Luxembourg

Phone +32 (0)2 466 55 66

Brasil

Phone +55 11 3215-4900

Canada

Phone +1 905 771 14 44

Česká republika

Phone +420 2 57 91 18 50

China

Phone +86 4000 121 000

+852-2153 6300

Danmark

Phone +45 45 82 64 00

Deutschland

Phone +49 211 5301-301

España

Phone +34 93 480 31 00

France

Phone +33 1 64 62 35 00

Great Britain

Phone +44 (0)1727 831121

India

Phone +91–22–4033 8333

Israel

Phone +972-4-6801000

Italia

Phone +39 02 27 43 41

Japan

Phone +81 (0)3 5309 2112

Magyarország

Phone +36 1 371 2680

Nederland

Phone +31 (0)30 229 25 44

SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch

Österreich

Phone +43 (0)22 36 62 28 8-0

Norge

Phone +47 67 81 50 00

Polska

Phone +48 22 837 40 50

România

Phone +40 356 171 120

Russia

Phone +7-495-775-05-30

Schweiz

Phone +41 41 619 29 39

Singapore

Phone +65 6744 3732

Slovenija

Phone +386 (0)1-47 69 990

South Africa

Phone +27 11 472 3733

South Korea

Phone +82 2 786 6321/4

Suomi

Phone +358-9-25 15 800

Sverige

Phone +46 10 110 10 00

Taiwan

Phone +886-2-2375-6288

Türkiye

Phone +90 (216) 528 50 00

United Arab Emirates

Phone +971 (0) 4 8865 878

USA/México

Phone +1(952) 941-6780

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee.

Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Änderungen vorbehalten ∙ Angegebene Produkteigenschaften und

technische Daten stellen keine Garantieerklärung dar.

Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie.

Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia.

Flere repræsentanter og agenturer på www.sick.com ∙ Med forbehold for

ændringer og fejl ∙ De anførte produktegenskaber og tekniske data udgør ikke nogen garantierklæring.

Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia.

Meer vestigingen en vertegenwoordigingen vindt u op www.sick.com ∙

Wijzigingen en correcties voorbehouden ∙ Aangegeven producteigenschap pen en technische gegevens vormen geen garantieverklaring.

Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía.

欲了解更多代表机构和代理商信息,请登录 www.sick.com

如有更改, 不另行通知 ∙ 对所给出的产品特性和技术参数

的正确性不予保证。.

Please note the validity of the additional operating instructions for automation functions

Page 2 of 3

SICK device specific

Index dec (hex)

1 (0x01)

Name

Sensing range

Format

(Offset)

Length

Bit (8) 16 Bit

ENGLISH

Access

1

Default

Value rw

Value / Range

0...65535

0 = SP2 not used

Remark [Unit]

Default value device specific

[mm]

2 (0x02) SP2

61 (0x3D) Q1 configuration

1 (0x01) Logic

2 (0x02) Mode

3 (0x03) Hysteresis

62 (0x3E) Setpoint 2

1 (0x01) Sensing range

2 (0x02) SP2

Bit (0) 8 Bit

Record 4 Byte

Bit (24) 8 Bit

Bit (16) 8 Bit

Bit (0) 16 Bit

Record 3 Byte

Bit (8) 16 Bit

Bit (0) 8 Bit

63 (0x3F) Q2 configuration

1 (0x01) Logic

2 (0x02)

3 (0x03)

Mode

Hysteresis

Record

Bit (0)

4 Byte

Bit (24) 8 Bit

Bit (16) 8 Bit

16 Bit rw rw rw rw

64 (0x40) Device / function name String 32 Byte rw

97 (0x61) Sender configuration UInt 8 Bit rw rw rw rw rw rw rw rw rw

121 (0x79) Pin 2 configuration UInt 8 Bit rw

128

128

0

128 = Vendor specific

128 = Vendor specific

0 = Autodefined hysteresis

0...65535

0 = SP2 not used

Default value device specific

128

128

0

128 = Vendor specific

128 = Vendor specific

0 = Autodefined hysteresis

*******

0

1

0 = Sender active

1 = Sender not active

0 = Deactivated

1 = External input

16 = Sender off

17 = Teach-in

32 = Detection output Q/

34 = Switching signal QL2

205 (0xCD) SICK profile version

219 (0xDB) Article No.

1 (0x01) Article No. IO-Link

Device

226 (0xE2) System state

1 (0x01) Detection output

Q.int

String 4 Byte

Record 7 Byte

Bit (0) 7 Byte

Record 1 Byte

Bit (0) 1 Bit ro ro ro ro ro

227 (0xE3) Notification handling UInt

1000

(0x3E8)

1001

(0x3E9)

1002

(0x3EA)

1003

(0x3EB)

1004

(0x3EC)

1005

(0x3ED)

1032

(0x408)

1033

(0x409)

1034

(0x40A)

1035

(0x40B)

1036

(0x40C)

1080

(0x438)

Counter Version

Counter Mode

Preset Mode

8 Bit rw

String 8 Byte

UInt

UInt

8 Bit

8 Bit ro rw rw

Preset Value UInt

Comparator Value Low UInt

16 Bit

16 Bit

Comparator Value High UInt

Debounce Version String

16 Bit

8 Byte

Debounce Time 1

Quality D1

Debounce Time 2

Quality D2

SLTI Version

UInt

UInt

UInt

UInt

16 Bit

16 Bit

16 Bit

16 Bit

String 8 Byte rw ro rw ro ro rw rw rw ro

0

0

0

0

10

10

0

0 false = No object detected true = Object detected

0 = all enabled

1 = all disabled

2 = Events enabled, PD invalid flag disabled

3 = Events disabled, PD invalid flag enabled

0 = up

1 = down

0 = preset internal disabled

1 = preset internal enabled

0...16383

0...16383

0...16383

0...30000

0...100

0...30000

0...100

[ms]

[%]

[ms]

[%]

DEUTSCH

SICK spezifisch

Index dez (hex)

1 (0x01)

Name

Schaltabstand

Format

(Offset)

Länge

Bit (8) 16 Bit

2 (0x02) SP2

61 (0x3D) Q1-Konfiguration

1 (0x01) Logik

2 (0x02) Modus

3 (0x03) Hysterese

62 (0x3E) Setpoint 2

1 (0x01) Schaltabstand

2 (0x02) SP2

Bit (0) 8 Bit

Record 4 Byte

Bit (24) 8 Bit

Bit (16) 8 Bit

Bit (0) 16 Bit

Record 3 Byte

Bit (8) 16 Bit

Bit (0) 8 Bit

63 (0x3F) Q2-Konfiguration

1 (0x01) Logik

2 (0x02)

3 (0x03)

Modus

Hysterese

Record

Bit (0)

4 Byte

Bit (24) 8 Bit

Bit (16) 8 Bit

16 Bit rw rw rw rw

64 (0x40) Gerätename / -funktion String 32 Byte rw

97 (0x61) Einstellung Sender UInt 8 Bit rw rw rw rw rw rw rw rw rw

121 (0x79) Pin-2-Konfiguration UInt 8 Bit

Zugriff

1

Standard

Wert rw

128

128

0

Wertebereich

0...65535

0 = SP2 nicht genutzt

128 = Herstellerspezifisch

128 = Herstellerspezifisch

0 = Automatische

Hysterese

Bemerkung [Einheit]

Standardwert gerätespezifisch

[mm] rw

128

128

0

0...65535

0 = SP2 nicht genutzt

128 = Herstellerspezifisch

128 = Herstellerspezifisch

0 = Automatische

Hysterese

*******

0

1

0 = Sender aktiv

1 = Sender nicht aktiv

0 = Deaktiviert

1 = Externer Eingang

16 = Sender Aus

17 = Teach-in

32 = Detektionsausgang Q/

34 = Schaltsignal

QL2

Standardwert gerätespezifisch

205 (0xCD) SICK-Profilversion

219 (0xDB) Artikelnummer

1 (0x01) Artikelnummer IO-

Link-Gerät

226 (0xE2) Systemstatus

1 (0x01) Detektionsausgang

Q.int

String 4 Byte

Record 7 Byte

Bit (0) 7 Byte

Record 1 Byte

Bit (0) 1 Bit ro ro ro ro ro

227 (0xE3) Benachrichtigungseinstellungen

UInt 8 Bit rw 0 false = Kein Objekt detektiert true = Objekt detektiert

0 = alle aktiviert

1 = alle deaktiviert

2 = Events aktiviert, PD-invalid-

Flag deaktiviert

3 = Events deaktiviert, PD-invalid-

Flag aktiviert

1000

(0x3E8)

1001

(0x3E9)

1002

(0x3EA)

1003

(0x3EB)

1004

(0x3EC)

1005

(0x3ED)

1032

(0x408)

1033

(0x409)

1034

(0x40A)

1035

(0x40B)

1036

(0x40C)

1080

(0x438)

Counter-Version

Zählermode

Vorwahlmode

Zählervorwahl

Vergleichswert unten

Vergleichswert oben

Debounce-Version

Entprellzeit 1

Qualität D1

Entprellzeit 2

Qualität D2

SLTI Version

String 8 Byte

UInt

UInt

8 Bit

8 Bit

UInt

UInt

UInt

String 8 Byte

UInt

UInt

UInt

UInt

16 Bit

16 Bit

16 Bit

16 Bit

16 Bit

16 Bit

16 Bit

String 8 Byte ro rw rw rw rw rw ro rw ro rw ro ro

0

0

0

10

10

0

0

0 = aufwärts

1 = abwärts

0 = interne Vorwahl aus

1 = interne Vorwahl ein

0...16383

0...16383

0...16383

0...30000

0...100

0...30000

0...100

[ms]

[%]

[ms]

[%]

1

2 ro = read only, wo = write only, rw = read/write / ro = nur lesen, wo = nur schreiben, rw = lesen/schreiben

COM values specify the bitrate (see IO-Link specification) / COM Werte spezifizieren die Baudrate (s. IO-Link Spezifikation): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)

WTB4C-3_A71

2146637628

9243603 139J

Australia

Phone +61 3 9457 0600

Belgium/Luxembourg

Phone +32 (0)2 466 55 66

Brasil

Phone +55 11 3215-4900

Canada

Phone +1 905 771 14 44

Česká republika

Phone +420 2 57 91 18 50

China

Phone +86 4000 121 000

+852-2153 6300

Danmark

Phone +45 45 82 64 00

Deutschland

Phone +49 211 5301-301

España

Phone +34 93 480 31 00

France

Phone +33 1 64 62 35 00

Great Britain

Phone +44 (0)1727 831121

India

Phone +91–22–4033 8333

Israel

Phone +972-4-6801000

Italia

Phone +39 02 27 43 41

Japan

Phone +81 (0)3 5309 2112

Magyarország

Phone +36 1 371 2680

Nederland

Phone +31 (0)30 229 25 44

SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch

Österreich

Phone +43 (0)22 36 62 28 8-0

Norge

Phone +47 67 81 50 00

Polska

Phone +48 22 837 40 50

România

Phone +40 356 171 120

Russia

Phone +7-495-775-05-30

Schweiz

Phone +41 41 619 29 39

Singapore

Phone +65 6744 3732

Slovenija

Phone +386 (0)1-47 69 990

South Africa

Phone +27 11 472 3733

South Korea

Phone +82 2 786 6321/4

Suomi

Phone +358-9-25 15 800

Sverige

Phone +46 10 110 10 00

Taiwan

Phone +886-2-2375-6288

Türkiye

Phone +90 (216) 528 50 00

United Arab Emirates

Phone +971 (0) 4 8865 878

USA/México

Phone +1(952) 941-6780

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee.

Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Änderungen vorbehalten ∙ Angegebene Produkteigenschaften und

technische Daten stellen keine Garantieerklärung dar.

Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie.

Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia.

Flere repræsentanter og agenturer på www.sick.com ∙ Med forbehold for

ændringer og fejl ∙ De anførte produktegenskaber og tekniske data udgør ikke nogen garantierklæring.

Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia.

Meer vestigingen en vertegenwoordigingen vindt u op www.sick.com ∙

Wijzigingen en correcties voorbehouden ∙ Aangegeven producteigenschap pen en technische gegevens vormen geen garantieverklaring.

Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía.

欲了解更多代表机构和代理商信息,请登录 www.sick.com

如有更改, 不另行通知 ∙ 对所给出的产品特性和技术参数

的正确性不予保证。.

Please note the validity of the additional operating instructions for automation functions

Page 3 of 3

SICK device specific

Index dec (hex)

1083

(0x43B)

Name

Logic 1

1084

(0x43C)

1085

(0x43D)

1086

(0x43E)

Logic 2

Timer 1 Mode

Timer 2 Mode

Format

(Offset)

UInt

Length

8 Bit

UInt

UInt

UInt

8 Bit

8 Bit

8 Bit

ENGLISH

Access

1

Default

Value rw 0 rw rw rw

0

0

0

Value / Range

0 = DIRECT

3 = Window Mode

4 = Hysteresis

Remark [Unit]

0 = DIRECT

3 = Window Mode

4 = Hysteresis

0 = deactivated

1 = T-on delay

2 = T-off delay

3 = T-on/T-off delay

4 = Impulse (one shot)

0 = deactivated

1 = T-on delay

2 = T-off delay

3 = T-on/T-off delay

4 = Impulse (one shot)

1087

(0x43F)

1088

(0x440)

1089

(0x441)

1090

(0x442)

Time 1 Setup

Time 2 Setup

Inverter 1

Inverter 2

UInt

UInt

UInt

UInt

16 Bit

16 Bit

8 Bit

8 Bit rw rw rw rw

1

1

0

0

Standard command

Index dec (hex)

Access

2 (0x02) Standard Command wo

1

Value

65

Name

Single Value Teach

130 Restore Factory Settings

192 Reset Counter

193 Preset Counter

1...30000

1...30000

0 = not inverted

1 = inverted

0 = not inverted

1 = inverted

Remark [Unit]

[ms]

[ms]

Events

Code dec (hex)

36000

(0x8CA0)

36001

(0x8CA1)

36004

(0x8CA4)

36005

(0x8CA5)

36006

(0x8CA6)

Name

Short Circuit on Qx

New parameters

Qualtiy of run alarm

Teach / value out of specified range

Value out of specified range

Error

Code dec (hex)

Additional Code

128 (0x80) 17 (0x11)

128 (0x80) 18 (0x12)

Name

Type

Notification

Notification

Notification

Notification

Notification

Index not available

Subindex not available

128 (0x80) 32 (0x20)

128 (0x80) 35 (0x23) Access denied

Remark [Unit]

Short circuit on outputs

Parameters have been changed

Low device performance, clean sensor

Teach / distance value out of specified range

Setup value out of specified range

Service temporarily not available

Remark [Unit]

Access occurs to a not existing index

Access occurs to a not existing subindex

Parameter is not accessible due to the current state of the device application

Write access on a read-only parameter

128 (0x80) 48 (0x30)

128 (0x80) 51 (0x33)

128 (0x80) 52 (0x34)

128 (0x80) 64 (0x40)

128 (0x80) 65 (0x41)

Parameter value out of range

Parameter length overrun

Parameter length underrun

Invalid parameter set

Inconsistent parameter set

Written parameter value is outside its permitted value range

Written parameter length is above its predefined length

Written parameter length is below its predefined length

Written single parameter collides with other actual parameter settings

Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed

Events

Code dez (hex)

36000

(0x8CA0)

36001

(0x8CA1)

36004

(0x8CA4)

36005

(0x8CA5)

36006

(0x8CA6)

DEUTSCH

SICK spezifisch

Index dez (hex)

1083

(0x43B)

Name

Logik 1

Format

(Offset)

UInt

Länge Zugriff

1

Standard

Wert rw 0

Wertebereich Bemerkung [Einheit]

1084

(0x43C)

1085

(0x43D)

1086

(0x43E)

Logik 2

Timer 1 Modus

Timer 2 Modus

UInt

UInt

UInt

8 Bit

8 Bit

8 Bit

8 Bit rw rw rw

0

0

0

0 = DIREKT

3 = Fenster Modus

4 = Hysterese

0 = DIREKT

3 = Fenster Modus

4 = Hysterese

0 = deaktiviert

1 = Einschaltverzögerung

2 = Ausschaltverzögerung

3 = Ein- / Ausschaltverzögerung

4 = Impuls (One

Shot)

0 = deaktiviert

1 = Einschaltverzögerung

2 = Ausschaltverzögerung

3 = Ein- / Ausschaltverzögerung

4 = Impuls (One

Shot)

1...30000

1087

(0x43F)

1088

(0x440)

1089

(0x441)

1090

(0x442)

Zeitwert 1

Zeitwert 2

Inverter 1

Inverter 2

UInt

UInt

UInt

UInt

16 Bit

16 Bit

8 Bit

8 Bit rw rw rw rw

1

1

0

0

1...30000

Standardkommando

Index dez (hex)

Zugriff

2 (0x02) Standardkommando wo

1

Wert

65

Name

Einzelpunkt-Teach

130 Auslieferungszustand wiederherstellen

192 Zähler rücksetzen

193 Zähler vorwählen

0 = nicht invertiert

1 = invertiert

0 = nicht invertiert

1 = invertiert

[ms]

[ms]

Bemerkung [Einheit]

Name

Kurzschluss Qx

Neue Parameter

Alarmausgang Betriebssicherheit

Teach / Wert außerhalb Wertebereich Notification

Wert außerhalb des zulässigen Bereichs

Typ

Notification

Notification

Notification

Notification

Bemerkung [Einheit]

Kurzschluss an Ausgang detektiert

Parameter wurden geändert

Schlechte Geräteperformance, Sensor reinigen

Teach / Distanzwert außerhalb des spezifizierten Bereichs

Einstellwert außerhalb des zulässigen Bereichs

Fehlercodes

Code dez (hex)

Additional Code

128 (0x80) 17 (0x11)

128 (0x80) 18 (0x12)

Name

Index nicht vorhanden

Subindex nicht vorhanden

Bemerkung [Einheit]

128 (0x80) 32 (0x20)

128 (0x80) 35 (0x23)

128 (0x80) 48 (0x30)

128 (0x80) 51 (0x33)

128 (0x80) 52 (0x34)

128 (0x80) 64 (0x40)

128 (0x80) 65 (0x41)

Service zur Zeit nicht verfügbar

Zugriff verweigert

Parameterwert außerhalb des gültigen

Bereichs

Parameterlänge zu groß

Parameterlänge zu klein

Ungültiger Parametersatz

Inkonsistenter Parametersatz

Zugriff auf einen nicht existierenden Index

Zugriff auf einen nicht existierenden Subindex

Auf den Parameter kann gerade nicht zugegriffen werden. Das Gerät erlaubt dies im aktuellen Zustand nicht

Schreibzugriff auf einen schreibgeschützten Parameter

Geschriebener Parameterwert liegt außerhalb des zulässigen Wertebereichs

Geschriebene Parameterlänge ist größer als erlaubt

Geschriebene Parameterlänge ist kleiner als erlaubt

Geschriebener Einzelparameterwert kollidiert mit den anderen Parametereinstellungen

Am Ende des Blockparametertransfers wurden Inkonsistenzen erkannt. Der Geräteplausibilitätscheck schlug fehl

1

2 ro = read only, wo = write only, rw = read/write / ro = nur lesen, wo = nur schreiben, rw = lesen/schreiben

COM values specify the bitrate (see IO-Link specification) / COM Werte spezifizieren die Baudrate (s. IO-Link Spezifikation): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement