Superior Pump 91370 Utility Pump Owner Manual

Superior Pump 91370 Utility Pump Owner Manual
OWNER’S MANUAL
INSTALLATION AND
OPERATION INSTRUCTIONS FOR
SUBMERSIBLE UTILITY PUMP
Model:
91270, 91270-25, 91370, 91370-25
91570, 91575
2301 Traffic St. NE
Minneapolis, MN 55413
1-800-495-9278
Superior Pump SD Utility Revised 08-11
8
If for any reason you have questions concerning your new Superior Pump, call us toll free at
1-800-495-9278.
Carefully read and understand all of the Warnings and installation instructions in this
manual. Failure to follow these instructions could lead to serious bodily injury and/or
property damage. Retain these instructions for future reference.
This pump has been manufactured with your needs in mind. Properly installed in the right
application, your new Superior Pump will give you years of carefree performance.
DANGER !
Water and electricity can be dangerous if certain precautions are not adhered to. This pump is
designed to operate perfectly safe in a water environment; however, improper use and installation
can result in personal harm from electrical shock. Please pay attention to the following warnings.
WARNING !
Never touch any electrical device, including this pump, when it is touching water, in water, or
even in a moist environment. Always unplug (disconnect the electricity) when working on or
installing the unit.
WARNING !
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Decko Products warrants this product free from material and/or manufacturing defects for one
year from date of purchase (three years on select cast iron pumps). As the sole and exclusive
remedy for a breach of this limited warranty, if the product is found by Decko Products to be
defective, Decko Products, at its option, will refund the purchase price or replace the product
with an equivalent product if it is returned to the place of purchase or returned postpaid to
Decko Products, ATTN: Warranty Dept., 2301 Traffic St. NE, Minneapolis, MN 55413, with
proof of purchase. Any disassembly, modification, or abuse of this product voids this limited
warranty. This product is not designed for pumping flammable or corrosive fluids, and use of
this product to pump such materials also voids this limited warranty
DECKO PRODUCTS DISCLAIMS ALL OTHER
EXPRESS OR IMPLIED WARRANTIES,
INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPORTANT NOTICE: Some commercial and residential insurance policies extend coverage
for damages incurred by product failure. In most cases, you will need to have possession of
the product to support your claim. In the case where you need to retain possession of the
product to support a damage claim you submit to your insurance company, Decko Products will
exchange the unit or refund the original price once the claim is settled with the insurer.
RISK OF ELECTRICAL SHOCK. This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle.
WARNING !
Do not use the power cord or discharge hose to carry or handle the pump. Doing so may cause
damage to the power cord or discharge hose. Use the carrying handle supplied with the pump.
WARNING !
Always use a grounded outlet. A three-prong mating type receptacle is needed for safe use.
This should be in accordance with the National Electric Code and any additional codes or laws
required by your local government.
NOTICE !
It is strongly recommended to use a ground fault interrupt device on any electrical appliance,
including this pump, when used in a wet or moist environment. This is required by many local
codes and enforcement agencies. It is strongly recommended by Superior Pump as it provides a
much safer installation and will greatly reduce possible injury from electrical shock.
2
7
DANGER !
REPLACEMENT PARTS
To order replacement parts call
1-800-495-9278
Do not use this pump to pump chemicals, flammable liquids, sewage or corrosive liquids. You
could injure yourself and the pump will fail. Pumping these types of liquids voids the warranty.
Superior Pump and other pump companies manufacture pumps for these types of liquids. Make
sure you purchase a pump designed for your specific needs. This pump will handle fluids with
the same characteristics as water. If you have any questions call us at 1-800-495-9278.
WARNING !
Your pump has thermal over-load protection built in. It is not recommended for pumping liquids
over 120° F. The thermal overload protector will automatically shut down the pump in an
overheat situation. It will then reset itself once the pump cools down. This overload is designed
as a safety device and it will fail after repeated use. Normal operation is for fluids between 32° F
& 120° F.
WARNING !
DO NOT RUN THE PUMP DRY. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to parts of
the pump. It may also shorten the life of your pump.
NOTICE !
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof type
cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
DANGER !
Keep all electrical connections away from wet and moist environments. Wet connections can
cause electrical shock resulting in personal injury.
Ref#
Description
Part #
1
Power Cord
99009
2
Handle
99050
4
Oil Fill Plug with O-ring
99056
5
Shaft Seal
99057
6
Impeller
99096
7
Gasket
99088
8
Volute/Base
99185
9
Intake Screen
99186
6
3
USE AND INSTALLATION
NOTICE ! Height and/or piping restriction will reduce the pump output performance. See
WARNING !
Always disconnect the power source before attempting to install, service or perform maintenance
on the pump. failure to do so may result in fatal electrical shock. Always disconnect the power
source before
the performance chart below. Whenever possible use the same or larger size pipe than the
pump discharge for optimum performance. Reducing the pipe size will not harm your pump, it
will just reduce the output.
PERFORMANCES
Your Superior Pump is designed and built to give you reliable performance and long life. It will
pump water automatically for years when properly installed in the right environment.
Model
INSTALLATION/OPERATION
1. Place the pump on a hard surface in the water. Do not set the pump directly in mud or sand.
This may cause the intake screen to clog or damage to your pump.
2. The water level must be at least ½” deep for the pump to operate.
3. Plug the power cord into a grounded 120-volt AC outlet. The pump will start to operate as
soon as the cord is plugged in.
4. The pump will remove water down to 1/2” of the surface
5. The pump should be turned off once the water reaches these levels.
6. Do not let the pump run dry. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to
parts of the pump. It may also shorten the life of your pump.
91270, 91270-25
91370, 91370-25
91575
Output in gallons per minute at listed discharge height
above pumping level
0’
5’
10’
15’
20’
25’
30
48
55
22
44
48
20
40
42
16
36
34
9
23
25
2
16
16
SPECIFICATIONS
Power supply requirements
120V, 60 Hz
Anything that will pass through the intake screen holes will pass through the pump without
causing damage. The intake screen on the pump removes easily for cleaning. The pump can
also be back-flushed using the garden hose adapter.
Motor
1/2 HP, Continuous Duty,
Split Capacitor
Thermally Protected
NOTE: This pump has a built in anti-airlock device. Leakage is normal from this device
1/4 HP Amps
3.8
1/3 HP Amps
4.1
1/2 HP Amps
4.1
Liquid Temperature Range
32°F-120°F (0°C - 49°C)
Circuit Requirements
15 amp minimum
Solids Handling
3/8”
Discharge Size
1-1/2” NPT or
Garden Hose
(with supplied adapter)
1/4 HP & 1/3 HP Warranty
1 Years
1/2 HP Warranty
3 Years
TROUBLESHOOTING
PROBLEM
If the pump does not
start or run
If the pump runs but
moves little or no
water
POSSIBLE CAUSES
HOW TO CORRECT
Pump is not plugged in, switch or breaker is off
Plug pump in or turn on switch/breaker
Check for blown fuses or tripped circuit breakers
or tripped GFCI outlets
Replace fuse, reset breaker, reset GFCI outlet
Motor thermal protector tripped
Allow pump to cool. Pump will reset
Clogged intake screen
Clean or replace screen
Clogged discharge hose/pipe
Remove clog
Frozen discharge hose/pipe
Allow hose/pipe to thaw
Pump is air locked
Clean out airlock hole with a paper clip or
pipe cleaner
Low line voltage
Check wire size and increase if necessary
Check valve is stuck in the closed position
Inspect, repair or replace if necessary
Worn, damaged or clogged pump parts
Inspect for wear, damage or clog and clean or
replace if necessary
Discharge head exceeds pump capacity
If pumping height is over 25’, the pump will not
move water. See performance chart
4
5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project