JENN-AIR ® DETAILED PLANNING DIMENSIONS
1 of 4
30" JX3™ GAS DOWNDRAFT COOKTOP
JGD3430G – 2959⁄64" x 185⁄16" x 211⁄2"
PRODUCT DIMENSIONS
A A
MODEL #
B B
TOP VIEW
A A
C C
I
I
H HJ J
E E
JGD3430G
in
cm
A
Overall width
2959⁄64
76.0
B
Overall depth
211⁄2
54.6
C
Width of cooktop base
28 ⁄64
72.1
D
Width of assembled blower motor and plenum
14 ⁄64
36.7
E
Height from blower motor to underside
of cooktop
185⁄16
46.5
F
Width from left side of cooktop base to
blower motor
17⁄32
3.1
G
Width from plenum to right side of cooktop base
1223⁄32
32.3
H
49⁄64
10.5
137⁄64
4.0
J
Height of cooktop base
B B with grates
Height of cooktop
K K
Height from gas inlet to top of grates
47
6 ⁄64
17.1
K
Depth of cooktop base
19 ⁄64
50.7
L
Height from plenum to underside of cooktop
L L
E E
16 ⁄64
42.6
I
25
29
61
49
F F
D D
G G
FRONT VIEW
B
K
L
E
SIDE VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8991AdZw117
JENN-AIR ® DETAILED PLANNING DIMENSIONS
2 of 4
30" JX3™ GAS DOWNDRAFT COOKTOP
JGD3430G – 2959⁄64" x 185⁄16" x 211⁄2"
OPENING/CLEARANCE DIMENSIONS
MODEL #
JGD3430G
in
cm
Width of combustible area above
cooking surface (min.)
Width from cooktop to fixed wall or
B
other combustible material (min.)
Width to center of vent opening option
C
(min.)
D Width to outer edge of outlet (min.)
Side
Height to bottom
of uncovered wood
Cabinet
E* or metal cabinet above cooking surface
(min.)
L
Height to bottom of uncovered wood
F
or metal cabinet (min.)
Height to center
M of vent opening
G
option
H Height to top edge of outlet (min.)
Height to top of gas installation area
I
(wall installation)
J** Depth to center of vent opening option
Depth of gas installation area (floor
K
installation)
L Depth of upper cabinet (recommended)
M Depth from cutout to wall (min.)
N Width of cutout
O Depth of cutout
Depth from cutout to front of
P
countertop (min.)
e Recommended electrical access location
g Recommended gas supply line location
Recommended venting location –
v
see pages 3-4 for ducting information
A
A
E*
F
B
B
G
I
H
e
v
D
C
J**
K
v
C
FRONT VIEW
30
76.2
6
15.2
77⁄8
20.0
10
25.4
30
76.2
18
45.7
1411⁄16
37.3
12
30.5
6
15.2
171⁄8
43.5
6
15.2
13
213⁄32
285⁄8
1915⁄16
33.0
6.1
72.7
50.6
21⁄8
5.4
*Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
**Based on installation in a 24" (61.0 cm) deep by 341⁄2" (87.6 cm) high
base cabinet with a 11⁄2" (3.8 cm) thick counter top.
GAS REQUIREMENTS
Natural Gas
This cooktop is factory-set for use with natural gas.
A
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert to
LP gas, use the LP gas conversion kit provided with the cooktop.
Side
Cabinet
L
E*
ELECTRICAL REQUIREMENTS
M
120 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required. A
time-delay fuse or dedicated circuit is recommended.
VENTING REQUIREMENTS
B
This cooktop must be exhausted outdoors unless using the duct-free filter
H
kit (JDA7000WX). Refer to kit instructions for further information.
N
M
O
P
SIDE VIEW
LOCATION REQUIREMENTS
v than
• To ensure cooktop base clearance, cabinet side walls need to be wider
the cutout.
C
• A minimum clearance of 2" (5.1 cm) is recommended between the blower
motor and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.
J**
• An under counter built-in oven cannot be installed under this cooktop.
v
TOP VIEW
C
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
I
G
8991AdZw117
e
D
K
JENN-AIR ® DETAILED PLANNING DIMENSIONS
3 of 4
DUCT-FREE KIT
JDA7000WX – 175⁄8" x 103⁄8" x 71⁄2"
JX3™ DOWNDRAFT COOKTOPS WITH DUCT-FREE VENTILATION
The duct-free filter kit (JDA7000WX) is approved for use with JX3™ downdraft cooktop models
JGD3536G, JGD3430G, JED4536G, JED3536G, JED4430G and JED3430G. The kit filters the air
from the downdraft system and ventilates the conditioned air into the room through the toe kick
of the base cabinet. Do not ventilate the air from the downdraft system into the base cabinet,
base cabinet pedestal, crawl space, wall or attic.
PRODUCT DIMENSIONS
MODEL #
B
A
B
A
JDA7000WX
in
cm
A
Width of housing
17 ⁄8
44.7
5
B
Height of housing
10 ⁄8
26.5
C
Depth of housing
71⁄2
19.0
D
Minimum height of toe kick
3
7.6
E
Minimum depth to toe kick
2 ⁄2
6.4
3
1
EXHAUST CUTOUT LOCATION
The cutout location in the toe kick area of the cabinet floor is
dependent upon the dimensions of the cooktop and base cabinet.
FRONT VIEW
C
D
Airflow
E
SIDE VIEW
C
Floor
D
Airflow
E
Floor
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8991AdZw117
JENN-AIR ® DETAILED PLANNING DIMENSIONS
4 of 4
DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops
also offer a duct-free installation option. For more details, refer to page 3.
DUCTING CONFIGURATIONS
DUCTING REQUIREMENTS
Roof jack
COOKTOP
31⁄4" x 10"
(8.3 cm x 25.4 cm) duct –
54' (16.5 m) max.
Gas
DUCT LENGTH
DUCT SIZE
10' (3.0 m) or less*
5" (12.7 cm)
diameter*
Between 10' (3.0 m)
and 60' (18.3 m)
10' (3.0 m) or less**
Electric
Transition elbow
Between 10' (3.0 m)
and 60' (18.3 m)
6" (15.2 cm)
diameter
31⁄4" x 10"
(8.3 cm x 25.4 cm)
5" (12.7 cm)
diameter**
6" (15.2 cm)
diameter
31⁄4" x 10"
(8.3 cm x 25.4 cm)
*Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
**May be used to vent straight out the back of the cooktop and directly
through the wall.
REAR DUCTING IN WALL TO ROOF
CALCULATING MAXIMUM DUCTING LENGTH
•M
aximum ducting length is 60' (18.3 m).
•E
ach 90° elbow equals 5' (1.5 m) duct.
•U
se no more than three 90° elbows.
• F lexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
• For ducting runs up to 30' (9.1 m), install cooktop as shipped.
• For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter ring
on the blower inlet housing.
• For altitudes above 4500' (1272.0 m), reduce recommended vent run by
20% for best performance.
REAR DUCTING THROUGH WALL TO OUTSIDE
6" (15.2 cm) diameter duct –
511⁄2' (15.7 m) max.
5" (12.7 cm ) to 6" (15.2 cm)
diameter transition
31∕4" x 10"
(8.3 cm x 25.4 cm) duct
Transition elbow
SIDE DUCTING IN TOE KICK TO OUTSIDE
6" (15.2 cm)
diameter wall cap
6" (15.2 cm)
diameter elbow
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8991AdZw117
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement