Legrand RF Remote Control Combo - 364697-01 Installation Instruction

Legrand RF Remote Control Combo - 364697-01 Installation Instruction

301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com

INSTRUCTION/INSTALLATION SHEET RF Remote Control Combo IS-0239 REV. C

RF Remote Receiver Housing RF Remote Keyfob Transmitter Keyfob Transmitter

R1 COMMON R1 N/O R1 N/C R2 COMMON R2 N/O R2 N/C +12VDC GND R3 COMMON R3 N/O R3 N/C R4 COMMON R4 N/O R4 N/C +12VDC GND R5 COMMON R5 N/O R5 N/C R6 COMMON R6 N/O R6 N/C +12VDC GND

RF Remote Interface Board

Figure 1

1. Introduction

relays. The P/N 364697-01 (see

Figure 1

) On-Q/Legrand RF Remote Control Combo provides remote control features for use with On-Q Home Lighting and Home Management Systems. The RF Remote Receiver features 6 general purpose and installer configurable relay outputs. The RF Remote Keyfob Transmitter buttons operate each of the 6

2. Description

The RF Remote Interface board provides connection points for wiring the RF Remote Receiver to an On-Q Home Lighting or Home Management System controller. Connection points are provide for the “Normally Open”, “Normally Closed” and “Common” terminals of each of the 6 receiver relays. 12VDC and GND (ground) connection points are provided for connecting power to the RF Remote Receiver. All connection points consist of 110 style IDC connectors for connection of category 3, 5 or 5E cable. The total cumulative length of all cabling connecting the RF Remote Receiver to the controller should not exceed 250 feet.

DEFAULT CONFIGURATION

The RF Remote Receiver’s relays are preprogrammed for Mode No. 3 (Validity) operation. The included RF Remote Keyfob Transmitter will activate the relays as such: ● Keyfob Button 1 = Relay 1 ● Keyfob Button 2 = Relay 2 ● Keyfob Button 3 = Relay 3 ● Keyfob Button 4 = Relay 4 ● Keyfob Buttons 1 & 2 (simultaneously) = Relay 5 ● Keyfob Buttons 3 & 4 (simultaneously) = Relay 6

ADDING A NEW KEYFOB

A total of 7 P/N 364708-01 keyfobs may be programmed into the receiver. To add a new keyfob into the receiver, use the following steps: ©Copyright 2008 by On-Q/Legrand All Rights Reserved . 1. Press and release the Program button, the receiver LED will turn on solid. 2. Press and release button 1 on the keyfob until the receiver LED turns off. This should require 3 presses.

DELETING KEYFOBS

To delete all keyfobs from the receiver’s memory without affecting keyfob button and relay output mode programming, follow these steps: 1. Push and hold the receiver’s Program button. 2. Watch to see the receiver’s LED turn on for 3 seconds, turn off for 3 seconds and then turn back on. 3. When the LED turns back on, release the Program button. 4. Follow the “ADDING A NEW TRANSMITTER” instructions to add keyfobs back into the receiver.

3. Programming

IMPORTANT PROGRAMMING STEPS

If the receiver is in default mode (Mode 3, Validity), always delete all memory prior to beginning new programming. ● Always ensure that the keyfob that you are going to use for programming is learned into the receiver. ● Always program the keyfob button first and then the relay output mode immediately afterwards, unless it is desired to leave the relay output mode in the default mode setting. ● All keyfob buttons may be programmed at once and then all of the output modes.

KEYFOB BUTTON PROGRAMMING

To program a keyfob button to operate a particular receiver relay, use the following steps. Multiple buttons or combinations of buttons may be associated with an individual relay. Multiple relays may be associated with a single button or combination of buttons. 1. Remove Jumper No. 1. 2. Press the Program button the number of times corresponding to the relay to be activated (1-6). 3. Watch to see that the receiver LED flashes the same number of times that the Program button was pushed. 4. Press the button or button combinations on the keyfob that are intended to operate the selected relay. 5. Watch to see that the receiver LED flashes back once to confirm. 6. Repeat steps 2-6 for any additional keyfob button programming required. 7. When programming is completed, replace Jumper No. 1.

RELAY OUTPUT MODE PROGRAMMING PROCEDURES

To change the relay output mode to something other than the default (Mode 3, Validity), follow these steps: 1. Remove Jumper No. 2. 2. Press the Program button the number of times corresponding to the relay to be activated (1-6). 3. Watch to see that the receiver LED flashes the same number of times that the Program button was pushed. 4. Press the button or button combinations on the keyfob corresponding to the output mode that is desired. 5. Verify that the receiver LED flashes once to confirm. 6. Repeat steps 2-5 for additional relay output programming. 7. When programming is completed, replace Jumper No. 2. Page 1 of 3

INSTRUCTION/INSTALLATION SHEET RF Remote Control Combo

301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com

The relay output modes are as follows: Mode 1 = Momentary (1 second activation) Mode 2 = Latching Mode 3 = Validity (remains active until keyfob button is released) Mode 4 = Timed 30 seconds Mode 5 = Timed 1 minute Mode 6 = Timed 5 minutes Mode 7 = Timed 20 minutes Mode 8 = Strobe (.5 seconds on, .5 seconds off) To program, use the following keyfob button/button combinations to configure the relay output modes: Mode 1 = Button 1 Mode 2 = Button 2 Mode 3 = Button 3 Mode 4 = Button 4 Mode 5 = Buttons 1 and 2 simultaneously Mode 6 = Buttons 3 and 4 simultaneously Mode 7 = Buttons 1 and 3 simultaneously Mode 8 = Buttons 2 and 4 simultaneously (Visable from Rear of RF Remote Interface Board) Programming LED Antenna Program Button Jumper No. 1 Jumper No. 2

Figure 2 DELETING KEYFOB BUTTONS AND RELAY OUTPUT MODES

To delete all programmed keyfob buttons and relay output mode programming, follow these steps: 1. Remove Jumper No. 1 and Jumper No.2. 2. Press and release the Program button once. 3. Watch to verify that the receiver LED flashes once to confirm. 4. Replace both jumpers.

TO CHANGE PROGRAMMING

Keyfob Buttons ● Keyfob buttons CANNOT be deleted without deleting all memory. Additional keyfob buttons can be added to control relay outputs. ● To add additional keyfob buttons, follow the directions in “KEYFOB BUTTON PROGRAMMING” ● The relay mode programming must be reprogrammed immediately after the keyfob button is added by following the steps in “RELAY OUTPUT MODE PROGRAMMING”. Otherwise, the relay will revert back to the default mode (Mode 3, Validity). ©Copyright 2008 by On-Q/Legrand All Rights Reserved .

IS-0239 REV. C

Relay Output Mode ● The relay output mode can be changed at any time by following the directions in “RELAY OUTPUT MODE PROGRAMMING”.

RESTORING DEFAULT MODE

To reset the receiver to the default settings, follow these steps: 1. Remove Jumper No. 1 and Jumper No.2. 2. Press and release the Program button once. 3. Watch to verify that the receiver LED flashes once to confirm. 4. Replace both jumpers. 5. Remove 12 VDC power from the receiver. 6. Apply 12 VDC power to the receiver.

4. Installation

The RF Remote Interface board mounts directly to any two-gang electrical box or old-work construction ring. Subsequent to termination of all cables, the RF Receiver housing may be inserted into the electrical box and the interface board may be mounted and covered with a blank two-gang cover plate. The transmission range of the RF Remote Keyfob is approximately 400ft in open air conditions. If it is intended that the RF Remote Control is to be operated from a vehicle, best results will be obtained by locating the RF Receiver in the garage. When operated from a vehicle, the transmission range of the RF Remote Keyfob transmitter will be approximately 100 ft. Two application modules are available for use with the RF Remote Receiver. The P/N 364645-01, ALC Distribution Module provides connection points for up to 4 of the receiver’s relays. The Distribution Module supports direct wiring of the RF Remote Receiver to provide a structured wiring installation. Switch inputs.

Figure 3

below depicts a typical application where the “Normally Open” positions of relay outputs 1 thru 4 are interfaced the On-Q Home Lighting Controller’s 4 Virtual Scene on

· Q

-

1 4 7 2 3

+ + + ON ON ON OF F OF F OF F CO M CO M CO M

5 6

+ + + ON + ON + OF F CO M OF F I 1 CO M + + CONTROLLER

8 1 0

+ ON OF F CO M 1 IN GND 2 IN

9 1 1

12V GND 3 IN GND ALC Distribution Module 4 IN

RF Remote Receiver Located In Garage

R1 COMMON R1 N/O R1 N/C R2 R2 N/O R2 N/C +12VDC GND R3 COMMON R3 N/O R3 N/C R4 R4 N/O R4 N/C +12VDC GND R5 COMMON R5 N/O R5 N/C R6 R6 N/O R6 N/C +12VDC GND Page 2 of 3

INSTRUCTION/INSTALLATION SHEET RF Remote Control Combo

301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com

IS-0239 REV. C RF RECEIVER R1 Common R1 Normally Open (N/O) R2 Common R2 Normally Open (N/O) R3 Common R3 Normally Open (N/O) R4 Common R4 Normally Open (N/O) +12 VDC HOME LIGHTING CONTROLLER or ALC DISTRIBUTION MODULE GND IN 1 GND IN 2 GND IN 3 GND IN 4 12 VDC

5. Warranty

On-Q/Legrand warrants to the end-user, each new ALC module to be free of defects in materials or workmanship for a period of one year from the date of original purchase from On-Q or its authorized reseller or installer. Each product is deemed warrantable under conditions of normal use and when installed and operated within On-Q specifications and in accordance with the applicable National Electrical Code and Safety Standards of Underwriters Laboratories. When determined to be warrantable, On-Q shall at its option and expense, replace any defective product with a new or reconditioned product. On Q will continue to warrant any replaced product for a period of ninety (90) days from shipment, or through the end of the original warranty period, which ever is longer.

Table 1

Alternatively, the On-Q P/N 364696-01 RF Remote Distribution Module provides connection points for all 6 of the receiver’s relay outputs (see

Figure 4

). Additionally, connection points are provided to allow access to each relays “Normally Open”, “Normally Closed” and “Common” outputs. The RF Remote Distribution Module supports direct wiring to the RF Remote Interface board to provide a structured wiring installation. on

· Q

12VDC + C N O R1 NC C N O R2 NC 1 2 V G N D C N O R3 NC C N O R4 NC 1 2 V G N D C N O R5 NC C N O R6 NC RF Remote Distribution Module 1 2 V G N D

RF Remote Receiver Located In Garage

R1 COMMON R1 N/O R1 N/C R2 COMMON R2 N/O R2 N/C +12VDC GND

Figure 4

R3 COMMON R3 N/O R3 N/C R4 COMMON R4 N/O R4 N/C +12VDC GND R5 COMMON R5 N/O R5 N/C R6 COMMON R6 N/O R6 N/C +12VDC GND ©Copyright 2008 by On-Q/Legrand All Rights Reserved . Page 3 of 3