Legrand PDFC-1A Multi-way Paddle Fan Speed Control Installation Instruction

advertisement

Legrand PDFC-1A Multi-way Paddle Fan Speed Control Installation Instruction
Multi-way Paddle
Fan Speed Control
Locator LED
On/Off Switch
Fan Speed Slider
SPECIFICATIONS
Voltage ............................................................... 120VAC, 60Hz
Maximum Load Rating ....................................................... 1.6A
Minimum Load Rating .............No minimum load requirement
Load (Multi-way) .................. Use only with ceiling paddle fans
Environment ..................................................... Indoor use only
Operating Temperature ............................0-25°C (32-77°F)
Humidity ...................................... 93% RH, non-condensing
Electrical Supply Wire Requirement
Minimum temperature rating ..........................75°C (167°F)
Tools Needed................ Insulated Screwdriver, Wire Strippers
Santa Clara, CA 95050
Installation Instructions
PDFC-1A
DESCRIPTION AND OPERATION
The PDFC-1A Paddle Fan Speed Control is designed to replace a standard fan
speed control switch. It controls ceiling paddle fans only. There are 3 fan speeds:
low, medium, and high. To change the fan speed move the slider up or down
until it clicks into place. To turn the fan OFF, press the bottom of the paddle. The
Locator LED turns ON. To turn ON the fan press the top of the paddle. The Locator
LED turns OFF. The fan will turn back on to the preset speed.
Caution: Use only with ceiling paddle fans. Do not use this device on a fan/light kit.
Important Notes
1. Only one fan speed control can be used in a 3-way circuit.
2. It is normal for the fan speed control to feel warm to the touch during
operation.
3. Protect the fan speed control from dust and dirt when painting or spackling.
4. Due to varying standards by fan manufacturers, the speeds on this control
may vary on all settings. Some fans may turn too fast on the high setting;
others may turn too slowly on the low setting.
5. Do not use to control a fan and light that can be operated by the same
switch.
6. The fan must have a thermal protection feature.
Derating
No derating is required for multi-gang installations.
INSTALLATION AND WIRING
1. Prior to installation, set fan pull chain to its highest speed (be sure fan is
operating at full speed before disconnecting power).
WARNING
Disconnect power to the wall switch box by turning OFF
the circuit breaker or removing the fuse from the circuit before
installing the PDFC-1A, or doing any electrical work.
2. Prepare the switch box
After the power is turned OFF at the circuit breaker box, remove the existing
wall plate and mounting screws. Pull the old switch out from the wall box.
Visit our website for FAQs: www.wattstopper.com
3. Identify the type of circuit
HOT (power from
circuit box)
You may connect the PDFC-1A to a single
pole or multi-way circuit. If you are unable
to clearly identify some or all of the wires
mentioned in this manual, you should consult
with a qualified electrician.
NEUTRAL
LOAD
(power
to fan)
Ground
Fig 1: Typical Single Pole
Switch Wiring
In a 3-way circuit (Fig. 2) two traveler wires connect to both switches. Another
wire provides power from the circuit box to one of the switches. A wire
connects from one switch to the load. A ground wire may also be connected to
a ground terminal on the old switches.
CEILING FAN
MASTER SWITCH
AUXILIARY SWITCH
TRAVELER
NEUTRAL
TRAVELER
LOAD/Common
(power to fan)
NEUTRAL
GROUND
HOT/Common
(power from circuit box)
GROUND
Fig. 2: Typical 3-Way Switch Wiring
Caution – For your safety: Connecting a proper ground wire to the fan speed
control provides protection against electrical shock in the event of certain
fault conditions. If a proper ground is not available, consult with a qualified
electrician before continuing installation.
4. Prepare the Wires
Strip Gage
Tag the wires currently connected to the existing switch
so that they can be identified later. Disconnect the wires.
1/2"
12.7 mm
Make sure the insulation is stripped off of the wires to
expose their copper cores to the length indicated by the Fig. 3 : #12 or
“Strip Gage” in Fig. 3 (approx. ½ inch).
#14 AWG
Call 800.879.8585 for Technical Support
5. Wire the fan speed control
Connect the wires to the flying leads on the PDFC-1A fan speed control(s) as
indicated in either step 5a or 5b.
5a. Single Pole Circuit: Wiring 1 PDFC-1A (Fig. 4)
• Connect the green or non-insulated (copper) GROUND wire from the circuit
to the green wire on the fan speed control.
• Connect the power wire from the circuit (HOT) to the black wire on the fan
speed control.
• Connect the fan (LOAD) to the appropriate red wire on the fan speed control
(See Fig. 4).
• The 2nd red wire is not used for a single pole circuit.
NEUTRAL
CEILING
FAN
(Cap off - do not use
for single pole wiring)
MADE IN CHINA
USE FOR
3-WAY
RED
RED
WARRANTY VOID IF OPENED
120VAC/60HZ
TURN OFF POWER
GREEN
BLACK
HOT
GROUND
FAN SPEED CONTROL
Fig. 4: Single Pole Wiring
Visit our website for FAQs: www.wattstopper.com
5b. 3-way wiring (Fig. 5)
• Note: Only one fan speed control can be used on a 3-way/multi-way circuit.
• Connect the green or non-insulated (copper) GROUND wire from the circuit
to the green wire on the fan speed control.
• Connect the power wire from the circuit (HOT) to the black wire on the fan
speed control.
• Connect one of the red wires to either of the remaining wires removed from
the switch.
• Connect the remaining red wire to the remaining wire removed from the
switch.
6. Put all the new switches into their wall boxes. Position the fan speed control
with the word “TOP” right side up. Use the captive screws on the mounting
strap to secure the switches to their wall boxes.
7. Attach the cover plates.
8. Set the PDFC-1A to OFF by pressing the bottom of the paddle.
9. Restore power and test. Cycle through the 3 speeds to make sure that the
fan does not stall in any of the ON positions. Do not allow the fan to remain
in a stalled position. DO NOT USE THE PULL CHAIN AFTER THE FAN
SPEED CONTROL IS INSTALLED.
NEUTRAL
3-WAY
SWITCH
MADE IN CHINA
RED
USE FOR
3-WAY
RED
HOT
CEILING FAN
WARRANTY VOID IF OPENED
120VAC, 60Hz
TURN OFF POWER
BLACK
GREEN
GROUND
GROUND
Fig. 5: Multi-way Wiring
COVER PLATES
WattStopper PD fan speed controls fit behind industry standard decorator style
switch cover plates.
Call 800.879.8585 for Technical Support
WARRANTY INFORMATION
WattStopper warranties its products to be free of defects in materials
and workmanship for a period of five (5) years. There are no obligations
or liabilities on the part of WattStopper for consequential damages
arising out of, or in connection with, the use or performance of this
product or other indirect damages with respect to loss of property,
revenue or profit, or cost of removal, installation or reinstallation.
Please
Recycle
2800 De La Cruz Boulevard, Santa Clara, CA 95050
Technical Support: 800.879.8585 • www.wattstopper.com
13142r2 6/2010