- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- Simplicity
- 01575-0
- User manual
advertisement
▼
Scroll to page 2
of 16
3100WATT Portable Generator Owner’s Manual Pro blem Bef Ques ore tion s? t a bac k k to ing yo s? call u the the st r unit gen ore, h 1-80 elpline erator 0-2 at M-F 70-1 8-5 408 CT Model No. 1575–0 (3,100 Watt AC Generator) Manual No. 188385 Revision 0 (4/6/2001) Visit our Generac website: www.generac-portables.com This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Generac Portable Products 3,100 Watt Generator EQUIPMENT DESCRIPTION SAFETY RULES This generator set was designed and manufactured for specific applications. Do Not attempt to modify the unit or use it for any application it was not designed for. If you have any questions about your generator’s application, ask your dealer/distributor or consult the factory. The generator is an engine-driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliance, tool and motor loads. This manual contains information for a generator that operates 120 and/or 240 Volt, single phase, 60 Hz devices that require up to 3,100 watts (3.1 kW) of power that pull up to 25.8 Amps at 120 Volts or 12.9 Amps at 240 Volts. The manufacturer could not possibly anticipate every circumstance that might involve a hazard. For that reason warnings in the manual and warnings on tags or decals affixed to the unit are not all–inclusive. If you intend to handle, operate or service the unit by a procedure or method not specifically recommended by the manufacturer, first make sure that such a procedure or method will not render this equipment unsafe or pose a threat to you and others. CAUTION! Do Not exceed the generator’s wattage/amperage capacity. Add up the rated watts of all devices you are connecting to generator receptacles at one time. This total should not be greater than 3,100 watts. See “Don’t Overload the Generator” on page 8. Read this manual carefully and become familiar with your generator set. Know its applications, its limitations and any hazards involved. The 3,100 watt portable generator has the following features: WARNING: • 120/240 Volt, 20 Amp locking receptacle. • 120 Volt, 20 Amp duplex receptacle. The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. • 3 quart overhead fuel tank. • The generator’s revolving field is driven at about 3,600 rpm by a Briggs and Stratton 5.5 h.p. engine. DANGER! You must isolate the generator from the electric utility by opening the electrical system’s main circuit breaker or main switch if this unit is used for backup power. Failure to isolate the generator from the power utility may result in injury or death to electric utility workers and damage to the generator due to a backfeed of electrical energy. Whenever unit is providing backup power, the electric utility must be notified. CAUTION! Do Not tamper with engine governed speed. High operating speeds are dangerous and increase risk of personal injury or damage to equipment. The generator supplies correct rated frequency and voltage only when running at proper governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads. Operating at excessively low speeds imposes a heavy load at such reduced speeds, when adequate engine power is not available, and may shorten engine life. DANGER! Generator exhaust gases contain DEADLY carbon monoxide gas. Carbon monoxide, if breathed in sufficient concentrations, can cause unconsciousness or death. Operate this equipment outdoors where adequate ventilation is available. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual. 2 Generac Portable Products 3,100 Watt Generator • The generator produces a very powerful voltage that can cause serious injury or death by electrocution. Never touch bare wires or receptacles. Never permit a child or any unqualified person to operate the generator. • Never operate the generator: in rain; in any enclosed compartment; when connected electrical devices overheat; if electrical output is lost; if engine or generator sparks; if flame or smoke is observed while unit is running; if unit vibrates excessively. • Never handle any kind of electrical cord or device while standing in water, while barefoot or while hands or feet are wet. Death or serious injury from electrocution may result. GROUNDING THE GENERATOR • Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area (such as metal decking or steel work). The National Electric Code requires the frame and external electrically conductive parts of the generator be properly connected to approved earth ground. Local electrical codes may also require proper grounding of the unit. For this purpose, a grounding wing nut (Figure 1) is provided on the cradle. • Never use worn, bare, frayed or otherwise damaged electrical cords with the generator. Death, serious injury and property damage from electrical shock may result. • Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. Never allow smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. Comply with all laws regulating storage and handling of gasoline. • Do Not overfill the fuel tank. Always allow room for fuel expansion. If tank is overfilled, fuel can overflow onto a hot engine and cause a FIRE or an EXPLOSION. • Never store a generator with fuel in the tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater, clothes dryer). FIRE or an EXPLOSION may result. • The unit requires an adequate flow of cooling air for its continued proper operation. Never operate the unit inside any room or enclosure where the free flow of cooling air into and out of the unit might be obstructed. Allow at least 2 feet of clearance on all sides of generator, even while operating unit outdoors, or you could damage the unit. • Never start, or stop the unit with electrical loads connected to receptacles with the connected devices turned ON. Start the engine and let it stabilize before connecting any electrical loads. Disconnect all electrical loads before shutting down the generator. • Do Not insert any object through cooling slots of the engine. You could damage the unit or injure yourself. Figure 1 — Grounding Wing Nut Grounding Wing Nut Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area. Be sure to keep the ground wire attached while you connect the electrode. Properly grounding the generator helps prevent electrical shock if ground fault conditions exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices. 3 Generac Portable Products 3,100 Watt Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Tank 120/240 Volt AC, 20 Amp Receptacle 120 Volt AC, 20 Amp Duplex Receptacle Circuit Breakers (AC) Grounding Wing Nut 120 Volt AC, 20 Amp Duplex Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads. Circuit Breakers (AC) — Each receptacle is provided with a push-to-reset circuit breaker to protect the generator against electrical overload. 120/240 Volt AC, 20 Amp Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads. Grounding Wing Nut — Provides a tie-point for connecting the generator frame to earth ground. Fuel Tank — Capacity of 3 U.S. quarts. 4 Generac Portable Products 3,100 Watt Generator • Use regular UNLEADED gasoline in the generator. Do Not use premium gasoline. Do Not mix oil with gasoline. Do Not overfill the gas tank. CARTON CONTENTS Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-270-1408. Review “Cold Weather Operation” on page 6. Shipped with your generator are: • Main unit • Engine and generator owner’s manuals • Clean area around fuel fill cap; remove cap. • Fill fuel tank with clean, fresh, unleaded gasoline. Be careful not to overfill. Allow 1.5" of tank space for fuel expansion, as shown in Figure 2. Figure 2 — Typical Tank Expansion Space BEFORE STARTING THE ENGINE Add Engine Oil • Make sure unit is on a level surface. • Follow the oil recommendations and oil fill instructions given in the engine owner’s manual. CAUTION! Any attempt to crank or start the engine • Install fuel cap and wipe up any spilled gasoline. before it has been properly serviced with the recommended oil results in an engine failure. IMPORTANT: It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel filter, fuel hose or tank during storage. Also, experience indicates that alcohol–blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See “Storage” on page 9. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur. NOTE: The generator’s revolving field rides on a pre–lubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing. Add Gasoline WARNING! Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do Not light a cigarette or smoke when filling the fuel tank. WARNING! Do Not overfill the fuel tank. Always leave room for expansion. IMPORTANT: When running your unit in cold weather be sure to shelter the unit from the wind. 5 Generac Portable Products 3,100 Watt Generator OPERATING THE GENERATOR CAUTION! Never start or stop unit with electrical loads connected AND with the connected devices turned ON. 4. Grasp the recoil handle and pull slowly until slight resistance is felt. Then pull rapidly to start engine. 5. Move choke lever to “Run” position a short distance at a time over several seconds in warm weather or minutes in cold weather. Let engine run smoothly before each change. Operate with choke in “Run” position. Starting the Engine Refer to the engine owner’s manual for complete starting instructions. Disconnect all electrical loads from the generator. Use the following start instruction steps by numerical order: Connecting Electrical Loads 1. • Let engine stabilize and warm up for a few minutes after starting. Turn the fuel valve to the “On” position (Figure 3). Figure 3 — Fuel Valve • Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads. • Do Not connect 240 Volt loads to the 120 Volt duplex receptacles. • Do Not connect 3–phase loads to the generator. Fuel Valve is shown in the On position • Do Not connect 50 Hz loads to the generator. 2. • DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator” on page 8. Place the choke lever in the “Choke” position (Figure 4). Stopping the Engine Figure 4 — Choke Positions • Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned ON. • Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator. • Move rocker switch to “Off” position. • Move the fuel valve to the “Off” position. 3. Cold Weather Operation Set the rocker switch to “On” position (Figure 5). Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your Generac generator may experience problems. Figure 5 — Rocker Switch In an emergency, use the original shipping box as a temporary shelter: • Cut off all flaps. • Cut out one of the long sides of the box to expose exhaust side of unit. Ensure a minimum of two feet clearance between open side of box and nearest object. Rocker Switch is shown in On position • Cut appropriate slots to access receptacles of unit. 6 Generac Portable Products 3,100 Watt Generator • Start unit, then place box over it. Figure 7 — 120 Volt, 20 Amp Duplex Receptacle CAUTION! Remove shelter when temperature is above 40°F [4°C]. For a more permanent shelter, build a structure that will enclose three sides and the top of the generator. • Make sure entire muffler-side of generator is exposed, as shown in Figure 6. Figure 6 — Temporary Cold Weather Shelter Wind 120/240 Volt AC, 20 Amp Locking Receptacle Use a NEMA L14-20 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volts AC at 20 Amps (or greater) (Figure 8). You can use the same 4-wire cord if you plan to run a 120 Volt load. Figure 8 — 120/240 Volt, 20 Amp Locking Receptacle NOTE: A typical unit is shown here, your unit may differ in appearance. • Ensure a minimum of two feet clearance between open side of box and nearest object. • Face exposed end away from wind and elements. • Enclosure should hold enough heat created by the generator to prevent problems. RECEPTACLES This generator is equipped with the following receptacles: 120 Volt AC, 20 Amp Duplex Receptacle This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 3,100 watts of power at 20 Amps for 120 Volts or 3,100 watts of power (3.1 kW) at 12.9 Amps for 240 Volts. The outlet is protected by a push-to-reset circuit breaker. This receptacle (Figure 7) is protected against overload by a push-to-reset circuit breaker. Use each receptacle to operate 120 Volt AC, single-phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volts at 20 Amps (or greater). CAUTION! Although this outlet states it has a 120/240 Volt 20 Amp rating (up to 4,800 watts), the generator is only rated for 3,100 watts. Powering loads that exceed the wattage/amperage capacity of the generator can damage it or cause serious injuries. 7 Generac Portable Products 3,100 Watt Generator • If the appliance, tool or motor does not give wattage, multiply 120 Volts times ampere rating to determine watts (volts x amps = watts). DON’T OVERLOAD THE GENERATOR • Some electric motors, such as induction types, require about three times more watts of power for starting than for running. This surge of power lasts for only a few seconds when starting such motors. Be sure you allow for this high starting wattage when selecting electrical devices to connect to your generator. First figure the watts needed to start the largest motor. Add to that figure the running watts of all other connected loads. Overloading a generator in excess of its rated wattage capacity can result in damage to generator and to connected electrical devices. Observe the following, to prevent overloading the unit: • Add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity. • The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usually be found on a data plate or decal affixed to the device. • A Wattage Reference Guide (Figure 10) is provided to help you determine how many items the generator can operate at one time. Figure 10 — Wattage Reference Guide Professional/Contractor Uses Tool/Appliance....................................................Watts *1/3 hp airless sprayer.............................................................600 3/8" hammer drill......................................................................600 Variable speed Sawzall®..........................................................960 ½" power drill.........................................................................1000 Quartz-halogen work light...................................................1000 Belt sander...............................................................................1200 7 ¼" circular saw....................................................................1500 7 ¼" worm drive saw............................................................1600 *1½ hp air compressor ........................................................1800 *10" power miter saw ...........................................................1800 6" bench grinder.....................................................................1800 *6" table planer.......................................................................1800 *10" table/radial arm saw .....................................................2000 Wire feed welder ...................................................................2400 * allow 3 times listed watts for starting this device Recreational/Home Uses Tool/Appliance....................................................Watts AM/FM clock radio.....................................................................50 Light bulb....................................................................................100 Fan................................................................................................200 20" color TV..............................................................................400 *Deep freezer............................................................................500 Personal computer and 15" monitor ...................................800 *1/3 hp furnace fan blower.....................................................800 Microwave oven ........................................................................800 *18 cu ft refrigerator ...............................................................800 Sump pump..............................................................................1000 Electric skillet ..........................................................................1250 *½ hp water well pump........................................................1400 *12,000 Btu window air conditioner .................................1400 Space heater ............................................................................1800 Electric water heater.............................................................4000 8 Generac Portable Products 3,100 Watt Generator eventually decrease the insulation resistance of these windings. SPECIFICATIONS Maximum Surge Watts . . . . . . . . . . . . . . . 3,875 Watts Continuous Wattage Capacity . . . . . . . . . 3,100 Watts Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0 Rated Maximum Continuous Load Current At 120 Volts . . . . . . . . . . . . . . . . . . . . . . 25.8 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . . . . 12.9 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . 60 Hertz To Clean the Generator • Use a damp cloth to wipe exterior surfaces clean. • Soft, bristle brush may be used to loosen caked on dirt or oil. • A vacuum cleaner may be used to pick up loose dirt and debris. • Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and opening on generator. These openings must be kept clean and unobstructed. MAINTENANCE RECOMMENDATIONS STORAGE The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a damaged or defective generator. The unit should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Engine Maintenance Generator Storage See engine owner’s manual for instructions. • Clean the generator as outlined in “To Clean the Generator” on this page. CAUTION! Avoid prolonged or repeated skin • Check that cooling air slots and openings on generator are open and unobstructed. contact with used motor oil. Used motor oil has been shown to cause skin cancer in certain laboratory animals. Thoroughly wash exposed areas with soap and water. KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS. CAUTION! Storage covers can be flammable. Do Not place a storage cover over a hot generator. Let the unit cool for a sufficient time before placing the cover on the unit. Generator Maintenance Engine Storage Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material. See engine owner’s manual for instructions. Other Storage Tips • Do Not store gasoline from one season to another. • Replace your gasoline can if it starts to rust. Rust and/or dirt in a gasoline can cause problems when you use that fuel with this unit. NOTE: Do Not use a garden hose to clean the generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will • Store in clean and dry area. 9 Generac Portable Products 3,100 Watt Generator NOTES 10 Generac Portable Products 3,100 Watt Generator TROUBLESHOOTING Problem Engine is running, but no AC output is available. Engine runs good but bogs down when loads are connected. Cause Solution 1. 2. 3. Circuit breaker is open. Poor connection or defective cord set. Connected device is bad. 1. 2. 3. 4. Fault in generator. 4. 1. 2. Short circuit in a connected load. Generator is overloaded. 1. 2. 3. Engine speed is too slow. 3. 4. 1. 2. 3. 4. 5. Engine will not start; or starts and runs rough. Shorted generator circuit. Rocker switch set to “Off”. Dirty air cleaner. Out of gasoline. Stale gasoline. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in gasoline. 8. Overchoking. 9. Low oil level. 10. Excessively rich fuel mixture. 11. Intake valve stuck open or closed. 12. Engine has lost compression. Engine shuts down during operation. Engine lacks power. Engine “hunts” or falters. 1. 2. 3. Out of gasoline. Low oil level. Fault in engine. 1. Load is too high. 2. 3. Dirty air filter. Engine needs to be serviced. 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. 11 4. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Reset circuit breaker. Check and repair. Connect another device that is in good condition. Contact Generac service facility. Disconnect shorted electrical load. See “Don’t Overload the Generator” on page 8. Contact Briggs and Stratton service facility. Contact Generac service facility. Set switch to “On”. Clean or replace air cleaner. Fill fuel tank. Drain gas tank and fill with fresh fuel. Connect wire to spark plug. Replace spark plug. Drain gas tank; fill with fresh fuel. Set choke to “Run” position. Fill crankcase to proper level. Contact Briggs and Stratton service facility. 11. Contact Briggs and Stratton service facility. 12. Contact Briggs and Stratton service facility. 1. Fill fuel tank. 2. Fill crankcase to proper level. 3. Contact Briggs and Stratton service facility. 1. See “Don’t Overload the Generator” on page 8. 2. Replace air filter. 3. Contact Briggs and Stratton service facility. 1. Move choke to halfway position till engine runs smoothly. 2. Contact Briggs and Stratton service facility. Generac Portable Products 3,100 Watt Generator SCHEMATIC AND WIRING DIAGRAM 12 Generac Portable Products 3,100 Watt Generator EXPLODED VIEW AND PARTS LIST– CONTROL PANEL Item 1 2 3 4 5 Part # B95600 75475 94396B 94396A 23365 Qty 1 4 1 1 4 Description COVER, Control Panel PPHMS, M4 0.7 x 10 CIRCUIT BREAKER CIRCUIT BREAKER WASHER, #8 Shakeproof Item 6 7 8 9 10 13 Part # 68759 38150 22264 51715 68867 Qty 1 4 4 4 1 Description OUTLET, 120V, 20A Duplex WASHER, Flat, #8 WASHER, Lock #8 NUT, M4 - 0.7 Hex TWISTLOCK, 120/240V, 20 Amp Generac Portable Products 3,100 Watt Generator EXPLODED VIEW AND PARTS LIST– MAIN UNIT 14 Generac Portable Products 3,100 Watt Generator Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 31 32 33 34 35 36 Part # Qty Description NSP 1 ENGINE A188299 1 ASSEMBLY, Cradle 67989 6 NUT, M8 Flanged Serrated 77816 1 DECAL, Caution Hot Muffler 85651 2 MOUNT, Vibration Engine 66365 1 HOUSING, Engine Adapter 86307 4 CAPSCREW, Hx Hd 5/16"-24 x 3/4" 188075 1 ASSEMBLY, Rotor 65791 1 BEARING, Ball 96796 1 WASHER, Flat (special) 24823 1 BOLT, Rotor 5/16" - 24 x 7.00" 91838J 1 ASSEMBLY, Stator 66825B 1 CARRIER, Rear Bearing 67022 1 GROMMET, Rubber 86308 4 BOLT, Stator M6-1.0 x 115mm 95003A 1 ASSY., Control Panel 74908 4 SCREW, M5 0.80 x 10mm Taptite 188554 1 DECAL, Control Panel 91825 1 RECTIFIER, Brush & Bridge 66849 2 SCREW, M5 - .80 x 16mm Taptite 86494 1 SCREW, M6 - 1.0 x 16 Wing 26850 2 WASHER, M6 1/4 Shakeproof 14353621 1 WIRE, Ground B4986 1 DECAL, Ground 23762 1 WASHER, #10 Shakeproof 85652 2 MOUNT, Vibration Alt. B2153 1 CAPSCREW, Self Driller #10 84242 2 GROMMET, Plastic RBC 81917 1 PIN, Roll, M4 x 10 93639 1 DECAL, Danger (English) 188555 2 DECAL, Unit 99541 1 DECAL, Start Instructions 43483 1 PLUG, 250V, 20Amp 188385 1 MANUAL, Owners 188637 1 MANUAL, Engine 15 LIMITED WARRANTY FOR PORTABLE GENERATORS (EXCEPT GN ENGINE SERIES) Generac Portable Products (hereafter referred to as the COMPANY) warrants to the original purchaser that its generator will be free from defects in materials or workmanship for a period of one year* from the date of original purchase. This warranty does not apply to units used for prime power in place of utility. This warranty does not include the gasoline engine when furnished or attached because such engine is covered solely by the warranty of the manufacturer of the engine. Starting batteries are not warranted by the COMPANY. *NOTE: Rental units, demonstrators, commercial applications, such as construction or income producing, are warranted for 90 days. Rental units, demonstrators, or commercial applications such as construction or utility which are resold are not covered under warranty by the COMPANY. Any warranty, whether expressed or implied, rests solely with the seller. During said warranty period, the COMPANY will, at its option, repair or replace any part which, upon examination by the COMPANY is found to be defective under normal use and service. All transportation costs under warranty, including return to the factory if necessary, are to be borne by the purchaser and prepaid by the purchaser. This warranty does not include nominal maintenance and service and does not apply to a generator set, or parts, which have been subjected to improper or unauthorized installation, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in the COMPANY's judgment, to adversely affect its performance and reliability. THERE IS NO OTHER EXPRESS WARRANTY. THE COMPANY HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW. THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS SPECIFIED IN THE EXPRESS WARRANTY. LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW. THE COMPANY ALSO DISCLAIMS ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SUCH AS THE LOSS OF TIME OR THE USE OF THE POWER EQUIPMENT, OR ANY COMMERCIAL LOSS DUE TO THE FAILURE OF THE EQUIPMENT; AND ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, or the exclusions or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. This warranty is effective for all products manufactured after June, 1998, and supersedes all prior warranties of the COMPANY. For service, contact your nearest COMPANY authorized warranty service facility or call 1-877-544-0982. Warranty service can only be performed by a COMPANY authorized service facility. At the time of requesting warranty service, evidence of original purchase date must be presented. GENERAC PORTABLE PRODUCTS Jefferson, Wisconsin U.S.A.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project