Extron XTP T FB 202 4K Manual

Extron XTP T FB 202 4K Manual
:
ANT omplete
ORoTm for thuecctions, aned
IMP
.c
tr
n
s
o
in
ng th
xtr
.e
on
ecti .
www stallati
e
conn
Go to uide, in s before er sourc
g
w
n
r
o
o
e
p
ti
s
e
u
ica
th
if
c
to
e
sp
uct
prod
XTP T FB 202 4K • Setup Guide
PWR
VGA
HDCP
HDMI IN
AUDIO IN
Tx
Rx
IR
OVER XTP
REMOTE
G
E
Rx Tx
LINK
SIG
Top Panel
Side Panel
F
XTP T FB 202 4K
XTP OUT
VGA IN
G
LAN
+
AUTO
Tx Rx
−
CLIP
RESET
G
POWER
12V
REMOTE
1.0 A MAX
1.0A
MAX RS-232
A
H
K
CONFIG
J
D
C
I
HDMI
This guide provides instructions for an experienced installer to install
and connect the Extron XTP T FB 202 4K into an Ackermann GB3
(OBO-Betterman), MK Electric CableLink Plus Modular, MK Electric
CableLink Plus Single Pan, ElectraPlan, or PUK floor box.
B
Figure 1. XTP T FB 202 4K Side and Top Panels
Input and Power Connections
Throughput and Control Connections
Control Connections and LEDs
A
B
C
D
E
F
G
H
I
J
K
DC power connector
Analog audio input connector
HDMI input connector
Analog 15-pin HD VGA connector
XTP output connector and LED indicators
RS-232/IR Over XTP connector
LAN connector
Remote RS-232 connector
USB configuration connector
Reset button
LED indicators
Installation
Planning
CAUTION:
ATTENTION:
Risk of personal injury. Failure to check these items may result in personal injury.
Failure to check the items listed below may result in property damage.
Check that the installation meets the building, electrical, and safety codes.
Mounting and Cabling
Step 1 — Preparing the floor box
a.
Install the floor box as directed by the manufacturer.
NOTE:
b.
Run all required cables and secure them with cable clamps.
Turn off or disconnect all equipment power sources.
Step 2 — Installing adapters
a.
Determine a position in the floor box to mount the XTP T FB 202 4K (see the image to the
right).
b.
Identify the applicable adapter plates for the floor box (see the table below).
c.
Install adapter plates to the same pair of mounting slots (see the table below for slot
recommendations) for the same position in the floor box. Slide the top flange into the
mounting slot and rotate the adapter plate down so the bottom flange rests against the
wall of the floor box.
Positions
1
2
3
Floor Box
Adapter Plates
Highest
Mounting Slot
Ackermann GB3
(OBO Betterman)
995241 (2)
1 and 3
995241 (2) and 995242 (1) 2
MK Electric CableLink Plus
Single Pan
995243 (2)
1 and 3
MK Electric CableLink Plus Modular
995244 (2)
1, 2, and 3
3rd from top
ElectraPlan
995300 (2)
1, 2, and 3
3rd from top
PUK
995300 (2)
1, 2, and 3
3rd from top
3rd from top
N/A
OBO Bettermann
GESR7 Floorbox Assembly
Additional Notes
For position 2, use the provided screws to attach
the 995242 adapter plate to either 995241 adapter
plate.
Do not use position 2. Use mounting screws to
secure the adapter plates to the floor box (see
figure 4).
1
XTP T FB 202 4K • Setup Guide (Continued)
Step 3 — Connecting side panel connectors under the adapters
a.
Connect a twisted pair cable between the XTP connector (see E above) of the XTP T FB 202 4K to an XTP receiver or XTP matrix switcher
(see Twisted Pair Recommendations for XTP Communication on page 4).
ATTENTION:
Do not connect this connector to a computer data or telecommunications network.
Signal LED indicator — Lights when the device is transmitting a video signal or a test pattern.
Link LED indicator — Lights when a valid link between an XTP input and output is established.
b.
For serial RS-232 control, connect a host device or control system to the 3.5 mm, 3-pole captive screw connector (see H on page 1). Wire
the connector as show in figure 2.
REMOTE
RS-232
G Rx Tx
Do not tin the wires!
Controlling
Device
Transmit (Tx)
Receive (Rx)
Ground (G)
Bidirectional
Transmit (Tx)
Receive (Rx)
Ground (G)
Figure 2. Remote RS-232 Wiring
c.
Power the XTP T FB 202 4K in one of the following methods:
•
Connect the provided external power supply to the 2-pole captive screw connector for local 12 V power (see A on page 1).
•
Connect an XTP Power Injector to the XTP connection between the XTP T FB 202 4K and a locally powered XTP receiver or XTP matrix
switcher.
•
Connect the XTP T FB 202 4K to an XTP matrix switcher and enable the remote power feature on the XTP matrix switcher.
Step 4 — Mounting
a.
Place the XTP T FB 202 4K in the desired position in the floor box so that the side panel connectors face towards the opening of the floor
box.
ATTENTION:
b.
Ensure there is enough space between the top panel connectors and the lid of the floor box so the lid fully closes.
Using the provided self-threading screws, secure the XTP T FB 202 4K to the adapter plates (see figures 3 through 6).
Ackermann GB3 (OBO Betterman) floor box
995241
HD
MI
IN
HD
MI
XT
PT
IN
VG
XT
PT
VG
A IN
FB
A IN
20
2 4K
HD
MI
VG
HD
VG
A
HD
AU
TO
CL
NF
IG
SE
T
DIO
PO
WE
1.012V R
A MA
X
- +
Rx
LA
N
IR
G
Tx
IN
Rx
Tx
AU
TO
NF
IG
Tx
Rx
RE
SE
T
LA
N
DIO
IN
RS OVER
-232
XT
P
IR
CO
P
Rx
G
Tx
Rx
PO
12 WER
V
A MA RE
X RSMO
-23TE
2
RE
MO
RS TE
-23
2
G
CP
AU
CL
IP
AU
RS OVER
-232
XT
Tx
RE
MI
CP
IP
CO
A
HD
- +
G
Rx
Tx
XT
P OU
T
XT
P OU
T
995242
Extron
XTP T FB 202 4K
(shown in OBO Bettermann
GESR7 floorbox assembly)
Figure 3. XTP T FB 202 4K in an Ackermann GB3 (OBO Betterman) Floor Box
ATTENTION:
2
For position 2, install adapter plate 995242 to one of the other adapter plates.
FB
20
2 4K
MK Electric CableLink Plus Single Pan floor box
HD
MI
IN
XT
PT
FB
VG
A IN
A
AU
TO
CL
IP
G
Tx
Rx
RES
ET
LA
DIO
IN
RS OVER
-23
XT
2
P
IR
CO
NFI
4K
MI
VG
HD
CP
AU
202
PW
R
HD
G
N
Tx
Rx
PO
WE
1.012V R
A MA RE
X RSMO
-23TE
2
- +
G
Rx
995243
XT
Tx
P OU
T
995243
H
D
I IN
M
X
TP
T
FB
2
20
A
4K
VG
IN
W
P
R
I
M
D
H
A
VG
H
D
U
IO
D
A
U
A
P
C
C
IN
TO
P
LI
R
R
32
NF
Tx
IG
T
N
Rx
LA
Tx
SE
G
RE
Rx
TP
X IR
-2
S
VE
O
CO
H
I IN
M
D
2
A
20
IN
Tx
VG
Rx
FB
G
T
- +
TP
X
PO
12VWER
A MA RE
X RSMO
-23TE
2
XT
W
P
R
H
M
D
I
A
VG
H
U
IO
D
A
U
P
A
C
D
C
IN
TO
P
LI
32
TP
X IR
-2
R
S
R
VE
O
IG
NF
CO
Tx
Rx
T
Tx
SE
G
RE
N
Rx
LA
PO
12VWER
A MA RE
X RSMO
-23TE
2
Extron
XTP T FB 202 4K
Do not use
this position
(shown in Cablelink Single
Pan floorbox assembly)
Figure 4. XTP T FB 202 4K in an MK Electric CableLink Plus Single Pan Floor Box
MK Electric CableLink Plus Modular floor box
D
H
M
I IN
TP
X
T
FB
A
4K
VG
2
20
IN
R
W
P
D
H
I
M
A
VG
U
P
A
C
D
H
P
LI
C
IN
TO
IO
D
U
A
TP
X IR
R
VE 2
O 23
SR
NF
CO
Tx
IG
Rx
G
T
SE
RE
Tx
N
Rx
LA
PO
WE
1.012V R
A MA
- +
RE
X RSMO
-23TE
2
G
Rx
XT
P OU
Tx
T
I IN
M
D
H
TP
X
T
FB
4K
A
VG
2
20
IN
R
W
P
M
D
H
I
A
VG
IO
TO
U
A
D
U
P
A
C
D
H
995244
IN
P
LI
C
R
TP
X IR
32
-2
S
R
VE
O
Tx
IG
NF
CO
N
Rx
LA
Tx
T
SE
G
RE
Rx
995244
PO
12VWER
A MA RE
X RSMO
-23TE
2
- +
G
Rx
Tx
Extron
XTP T FB 202 4K
XT
P OU
T
(shown in Cablelink Plus
modular floorbox assembly)
Figure 5. XTP T FB 202 4K in an MK Electric CableLink Plus Modular Floor Box
ElectraPlan or PUK floor box
HD
MI
IN
XT
PT
VG
A IN
PW
HD
MI
VG
CP
AU
20
2 4K
A
HD
CL
IP
FB
R
AU
DIO
TO
IN
NF
CO
RS OVER
-23
XT
2
P
IR
Tx
IG
G
T
Tx
SE
RE
Rx
Rx
LA
N
PO
WE
1.012V R
A MA
- +
RE
X RSMO
-23TE
2
G
Rx
Tx
XT
P OU
T
HD
MI
IN
XT
PT
VG
A IN
FB
20
2 4K
PW
HD
995300
MI
CP
AU
AU
TO
CL
IP
DIO
IN
RS OVER
-23
XT
2
P
IR
NF
CO
Tx
IG
T
Rx
N
Tx
SE
LA
G
RE
Rx
995300
VG
A
HD
R
PO
12VWER
A MA RE
X RSMO
-23TE
2
- +
G
Rx
Extron
XTP T FB 202 4K
Tx
XT
P OU
T
(shown in Electraplan
floorbox assembly)
Figure 6. XTP T FB 202 4K in an ElectraPlan (or PUK) Floor Box
3
Step 5 — Connecting Inputs
a.
Connect an unbalanced analog audio input source to the 3.5 mm TRS jack. Both video inputs can share this audio input. HDMI embedded
audio is normally given priority (see B on page 1).
b.
Connect an analog RGB video source to the female 15-pin HD VGA connector (see D on page 1).
c.
Connect a digital video source to the female HDMI connector (see C on page 1). It can accept HDMI, DVI (with an appropriate adapter), or
DisplayPort video signals.
Video input from a DisplayPort source must be a dual-mode DisplayPort source.
NOTE:
b.
Rx Tx G
Rx
Tx
To pass bidirectional serial command signals between XTP-compatible devices, connect a control
device to the three leftmost poles (Tx, Rx, and G) of the 5-pole captive screw connector (see F on
page 1). To transmit and receive IR signals, connect a control device to the three right most poles
(G, Tx, and Rx).
Tx Rx G
a.
IR Device
Tx/Rx
Pins
IR
Step 6 — Connecting Throughput Devices
RS-232
NOTE:
Tx Rx G
RS-232 and IR data can be transmitted simultaneously and share the ground pole (G).
RS-232 Device
Connect a host device or control LAN or WAN to the LAN RJ-45 connector for pass-through 10/100Base-T Ethernet communication
(see G on page 1). This is an Ethernet pass-through port with LEDs to indicate link and activity status.
Step 7 — Connecting a Control Device
Connect a host device, such as a computer, to the female mini-USB B port to configure the device or update firmware (see I on page 1).
Twisted Pair Recommendations for XTP Communication
The XTP T FB 202 4K is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP, SF/UTP, and S/FTP) and unshielded twisted pair
(U/UTP) cable. Extron recommends using the following practices to achieve full transmission distances up to 330 feet (100m) and reduce
transmission errors.
•
•
•
Use Extron XTP DTP 24 SF/UTP cable for the best performance. If not using XTP DTP 24 cable, at a minimum, Extron recommends
24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.
Pins:
TIA/EIA-T568B
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
12345678
Pin Wire T568A
Color
Pin
Wire color
Limit the use of more than two pass-through points, which may include patch points, punch down
1 1 White-orange
connectors, couplers, and power injectors. If these pass-through points are required, use CAT 6 or
White-green
6a shielded couplers and punch down connectors.
2 Orange
2 Green
33
44
NOTE: When using CAT 5e or CAT 6 cable in bundles or conduits, consider the following:
• Do not exceed 40% fill capacity in conduits.
• Do not comb the cable for the first 20 m, where cables are straightened, aligned, and
secured in tight bundles.
•
•
Separate twisted pair cables from AC power cables.
Insert Twisted
Pair Wires
White-g
Blue
Blue
Blue
White-blue
5 5 White-blue
White-b
Orange
6 6 Green
Green
8
8 Brown
Brown
RJ-45
Connector
Operation
After all connected devices are connected and powered on, the system is fully operational. The XTP T FB 202 4K can be configured and
controlled through the Extron XTP System Configuration Software or SIS™ commands (see the XTP T FB 202 4K User Guide available on the
Extron website, www.extron.com).
Indicators
Power LED indicator — Lights when power is applied.
HDMI LED indicator — Lights when the HDMI input signal is detected.
VGA LED indicator — Lights when the VGA input signal is detected.
HDCP LED indicator — Lights when the HDMI input signal is encrypted.
Auto switch LED indicator — Lights when device is in auto switch mode.
Audio Clipping LED indicator — Lights when the analog audio input signal remains above -3 dBFS. It remains lit for 200 ms after the signal falls
below -3 dBFS.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
4
© 2019 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
White-o
Orange
White-green
White-orange
White-brown
7 7 White-brown
Loosely place cables and limit the use of tie wraps or hook and loop fasteners.
T5
Wir
68-2832-50 Rev. A
04 19
White-b
Brown
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement